• Title/Summary/Keyword: Cathode water

Search Result 286, Processing Time 0.031 seconds

The Operating Condition and Flow Field Design Effect on the Anode Water Management of a Proton Exchange Membrane Fuel Cell (PEMFC) (운전조건 및 유로형상에 따른 고체고분자형 연료전지의 수소극에서의 수분관리)

  • Hong, In Kwon;Kim, Sunhoe
    • Applied Chemistry for Engineering
    • /
    • v.22 no.5
    • /
    • pp.518-521
    • /
    • 2011
  • A PEMFC single cell with the active area of $25cm^2$ was used to verify the effect of water management in the anode. Water management is one of the most critical operating variables. In this paper the effect of operating condition change, such as anode humidification and temperature, was investigated under constant current density of $200mA/cm^2$ where possible anode flooding operating area. Also experiments to observe the effect of the anode and cathode stoichiometry change and flow field design on the water management were performed. The water management was effected by the stoichimetry change. The temperature and humidification change also affected the fuel cell performance.

Experimental Study of Performance of PEMFC Operated in Dead-End Mode (수소극 Dead-End 모드 고분자 전해질 연료전지의 실험적 연구)

  • Ji, Sang-Hoon;Hwang, Yong-Sheen;Choi, Jong-Won;Lee, Dae-Young;Park, Joon-Ho;Jang, Jae-Hyuk;Kim, Min-Soo;Cha, Suk-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.643-648
    • /
    • 2010
  • Portable fuel cells are commonly operated in the dead-end mode because of such as high fuel utilization. However, the performance of such systems deteriorates continuously with an increase in the amount of by-products such as water vapor and nitrogen. In this study, to verify the effect of water vapor on Proton Exchange Membrane Fuel Cells (PEMFCs), constant-load experiments were carried out for a current density of 600 mA/cm2 and a voltage of 0.4 V, respectively. The performance of the cell was more stable under constant voltage conditions than under constant current density conditions. Condensed water accumulated in the anode channel near the cell outlet. The experimental results show how the relative humidity (RH = 0.15, 0.4 and 0.75) of air at the cathode side affect the performance of PEMFCs with dead-end anode. At RH values higher than 0.15, the mean power density increased by up to 51% and the mean purge duration decreased by up to 25% compared to the corresponding initial values.

Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water (알칼리 환원수 필터의 산화환원전위 안정화 평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.129-135
    • /
    • 2016
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. Evaluation of the stability of oxidation-reduced potential (ORP) using the filter of the alkaline water. This study utilizes the three filter of activated carbon, UF, carbon block in alkaline reduced water equipment. Passing the water to the filter is evaluated that the OPR values are stability in accordance with the change of the volume in the bucket. Alkaline reduced water equipment is a system that has the function of making the water reduction. This system is the values of the human body beneficial minerals and ORP are made in the functional water has a very low value than general water. Which has passed through the filter the water in the water negative ions and positive ions through the electrolytic. After electrolysis, the cathode side by water, including $Ca^+$, $K^+$, $Mg^+$, $Na^+$ water gets Alkaline Reduced Water containing the minerals beneficial to the human body. A positive electrode side is made of the organic materials that have an anion such as chlorine (Cl), phosphorus (P), sulfur(S). This experiment uses the Alkaline Reduced Water to adjust the magnitude of the voltage of the electrolysis in the Alkaline Reduced Water. That is 1st step(pH8) 2nd step (pH8.5) 3th step (pH9), 4th step (pH9.5) in the Alkaline Reduced Water and -1st step (pH6.0), -2nd step (pH5.0) used as the acidic oxidation water. When the water passes through the three filter in this system was evaluated whether the ORP values are changed and stabilized. When about 100 liters of water passing through the filter was confirmed that the ORP values are stability and evaluation.

Effect of Temperature on Electrochemical Degradation of Membrane in PEMFC (PEMFC 고분자 막의 전기화학적 열화에 미치는 온도의 영향)

  • Lee, Ho;Kim, Taehee;Son, Ik Jae;Lee, Jong Hyun;Lim, Tae Won;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.47 no.4
    • /
    • pp.441-445
    • /
    • 2009
  • Effect of temperature on membrane degradation in PEMFCs was studied. After cell operation at different temperatures($60{\sim}90^{\circ}C$) under accelerating degradation conditions(OCV, anode dry, cathode RH 65%) for 144 h, cell performance decreased from 12 to 35%. The results of FER in effluent water showed that this decrease in cell performance was caused by membrane degradation by the attack of $H_2O_2$ or oxygen radicals(${\cdot}OH$, $HO_2{\cdot}$) and that resulted in increase in gas crossover for radical formation. Radical formation on the electrode was confirmed by ESR. Activation energy of 66.2 kJ/mol was obtained by Arrhenius plot used to analyze the effect of temperature on membrane degradation. Increase of cell temperature enhanced gas crossover rate, radical formation rate and membrane degradation rate.

Study on the Development of Hybrid NMP Recovery System for Recovering the Used NMP in Lithium Ion Battery Cathode Manufacturing Process (리튬이온전지 양극제조 공정에서 사용된 NMP를 회수하기 위한 하이브리드형 NMP 회수시스템 개발에 관한 연구)

  • Hwang, Soon Ho;Nam, Seung Beak;Kim, Dong-Kwon;Kim, Yang Jun;Kang, Sung Eun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.5
    • /
    • pp.289-296
    • /
    • 2016
  • The availability of NMP, a solvent used in the manufacturing process of cathode material for lithium ion battery, depends on importation, and the price remains high because of the monopoly of BASF and ISP. For these reasons, most Lithium ion battery manufacturers reuse NMP after recovering it from the exhaust air in the drying process. In Korea, absorption method is mainly used for recovering NMP from the absorption tower using the hydrophilicity of NMP. However, this system has a few disadvantages, such as low purity (80%) of the recovered NMP and 100% emission due to high water content of the treated gas. In this study, we develop a hybrid NMP recovery system by combining cooling condensation method with concentration method, by which it is possible to obtain an NMP recovery rate of 99.6%, and a high purity (96.1%) of the recovered NMP.

A study on temperature characteristic of the gases supplied to SOFC system by utilizing the ship exhaust gas (선박 배기가스 활용에 따른 SOFC 시스템 공급가스의 온도특성에 관한 연구)

  • Park, Sang-Kyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.822-828
    • /
    • 2013
  • Since the operating temperature of Solid Oxide Fuel Cell (SOFC) is high, the heat management of the gases supplied to fuel cell system is important. In this paper, the temperature characteristic of the gases supplied to the anode and the cathode of the fuel cell is studied in case of utilizing the waste heat contained in the ship exhaust gas as a heat source to heat up the fuel, gas and water supplied to a 500kW SOFC system for a ship power. For the fuel cell system proposed in this paper, the temperature of gases supplied to the anode and the cathode was the highest temperature at 963K when the exhaust gas of the fuel cell was utilized as the heat source for gases supplied to fuel cell system instead of utilizing the ship exhaust gas. In addition, the engine power did not effect on the temperature of gases supplied to the fuel cell stack.

Electrochemical Control of Metabolic Flux of Weissella kimchii sk10: Neutral Red Immobilized in Cytoplasmic Membrane as Electron Channel

  • PARK, SUN-MI;KANG, HYE-SUN;PARK, DAE-WON;PARK, DOO-HYUN
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.80-85
    • /
    • 2005
  • Electrochemical control of the metabolic flux of W. kimchii sk10 on glucose and pyruvate was studied. The growing cell of W. kimchii sk10 produced 87.4 mM lactate, 69.3 mM ethanol, and 4.9mM lactate from 83.1mM glucose under oxidation condition of the anode compartment, but 98.9 mM lactate, 84.3mM ethanol, and 0.2 mM acetate were produced from 90.8 mM glucose under reduction condition of the cathode compartment for 24 h, respectively. The resting cell of W. kimchii sk10 produced 15.9 mM lactate and 15.2 mM acetate from 32.1 mM pyruvate under oxidation condition of the anode compartment, and 71.3 mM lactate and 3.8 mM acetate from 79.8mM pyruvate under reduction condition of the cathode compartment. The redox balance (NADH/$NAD^+$) of metabolites electrochemically produced from pyruvate was 1.05 and 18.76 under oxidation and reduction conditions, respectively. On the basis of these results, we suggest that the neutral red (NR) immobilized in bacterial membrane can function as an electron channel for the electron transfer between electrode and cytoplasm without dissipation of membrane potential, and that the bacterial fermentation of W. kimchii sk10 can be shifted to oxidized or reduced pathways by the electrochemical oxidation or reduction, respectively.

Rechargeable Zn-air Energy Storage Cells Providing High Power Density (고출력.고에너지 밀도의 아연금속-공기전지)

  • Park, Dong-Won;Kim, Jin Won;Lee, Jae Kwang;Lee, Jaeyoung
    • Applied Chemistry for Engineering
    • /
    • v.23 no.4
    • /
    • pp.359-366
    • /
    • 2012
  • Zn-Air energy storage cell is an attractive type of batteries due to its theoretical gravimetric energy density, cost-effective structure and environmental-friendly characteristics. The chargeability is the most critical in various industrial applications such as smart portable device, electric vehicle, and power storage system. Thus, it is necessary to reduce large overpotential of oxygen reduction/evolution reaction, the irreversibility of Zn anode, and carbonation in alkaline electrolyte. In this review, we try to introduce recent studies and developments of bi-functional air cathode, enhanced charge efficiency via modification of Zn anode structure, and blocking side reactions applying hybrid organic-aqueous electrolyte for high power density rechargeable Zn-Air energy storage cells.

Characterization of Nickel Composite Plating with TiO2 Particles for Photolysis of Organic Compound (유기물 광분해용 니켈-TiO2 복합도금 전극 특성에 관한 연구)

  • Choi, Chul-Young;Cho, Seung-Chan;Ryu, Young-Bok;Kim, Young-Seok;Kim, Hyoung-Chan;Kim, Yang-Do
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.3
    • /
    • pp.125-130
    • /
    • 2007
  • Many fundamental studies have been carried out regarding waste water and hazardous gas treatment technology using the photolysis effect of $TiO_2$. However, photolysis of both organic and organic-inorganic binders immobilizing $TiO_2$ makes permanent use impossible. In this study we manufactured a catalytic electrode by nickel-$TiO_2$ composite plating in order to immobilize $TiO_2$. The surface properties according to the current density changes of cathode and concentration changes of $TiO_2$ powder in nickel plating bath has been analysed with EDX, XRF, SEM, Raman spectrometer etc. The characterization of the catalytic electrode in decomposition of organic compound has been obtained by using UV-Visible spectrophotometer through analysing concentration changes of methyl orange solution containing the catalytic electrode vs. time with projecting UV-light in the solution. The study shows that a catalytic electrode of nickel-$TiO_2$ composite plating with high-efficiency in decompostion of organic compound has been formed under high concentration of $TiO_2$ powder and low current density of cathode.

Performance Degradation of Dead-end Type PEMFC by Startup and Shutdown Cycles (시동/정지 반복에 의한 데드엔드형 고분자전해질 연료전지의 성능 감소)

  • Jeong, Jaehyeun;Jeong, Jaejin;Song, Myunghyun;Chung, Hoibum;Na, Ilchai;Lee, Ho;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.540-544
    • /
    • 2013
  • During start up and shut down of a proton exchange membrane fuel cells (PEMFC), the performance and lifetime of PEMFC were reduced. In this study, effect of startup and shutdown were investigated in dead-end type PEMFC using oxygen as a cathode gas with polarization curve, impedance spectroscopy (EIS), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Dummy load which eliminates residual hydrogen and oxygen during startup and shutdown operation should be applied to mitigated the degradation of PEMFC performance. At 50% relative humidity (RH) under the repetitive on/off cycling, the cell performance decayed faster than at 100% RH because of corrosion of the cathode carbon support. Water suppling into cell reduced the degradation rate of dead-end type PEMFC during start up and shut down cycling at 50% RH.