• Title/Summary/Keyword: Cancer imaging

Search Result 1,166, Processing Time 0.028 seconds

A Case Report on Papillary Thyroid Cancer for the Recurrence of Regional Cervical Lymph Nodes improved by Korean medicine (갑상선 유두암으로 수술 후 좌우 림프절 전이 환자의 장기간 복합 한의약 치료 증례보고)

  • Hae-won, Lee;Soo-bin, Lee;Hye-won, Kim;Jin-Gu, No;Hye In, Jeong;Jun-Hyoung, Kim;Kyeong Han, Kim
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.26 no.3
    • /
    • pp.29-40
    • /
    • 2022
  • Objective : This study assessed the effect of a combination of Korean medicine on a thyroid papillary cancer patient who was diagnosed with local lymph node metastasis after thyroidectomy and lymph node dissection but did not want surgery. Methods : Gami-Palmultang administration and moxibustion(large Bmoxa cautery) were performed for six years. Treatment outcomes were evaluated with Brief Fatigue Inventory (BFI), Numerical Rating Scale (NRS), Insomnia Severity Index (ISI), Functional Assessment of Cancer Therapy-General (FACT-G), blood test/ CT imaging results, and patient's statements. Results : After the treatment, all symptoms have been alleviated, the quality of life has increased, and it has been maintained without further metastasis of tumors for six years. Conclusion : Korean medicine treatment along with active observation can be an alternative to patients who do not want surgical treatment after recurrence of local lymph nodes in thyroid papillary cancer, and can have positive results in improving the quality of life.

The Application of Radiolabeled Targeted Molecular Probes for the Diagnosis and Treatment of Prostate Cancer

  • Luyi Cheng;TianshuoYang;Jun Zhang;Feng Gao;Lingyun Yang;Weijing Tao
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.574-589
    • /
    • 2023
  • Radiopharmaceuticals targeting prostate-specific membrane antigens (PSMA) are essential for the diagnosis, evaluation, and treatment of prostate cancer (PCa), particularly metastatic castration-resistant PCa, for which conventional treatment is ineffective. These molecular probes include [68Ga]PSMA, [18F]PSMA, [Al18F]PSMA, [99mTc]PSMA, and [89Zr]PSMA, which are widely used for diagnosis, and [177Lu]PSMA and [225Ac]PSMA, which are used for treatment. There are also new types of radiopharmaceuticals. Due to the differentiation and heterogeneity of tumor cells, a subtype of PCa with an extremely poor prognosis, referred to as neuroendocrine prostate cancer (NEPC), has emerged, and its diagnosis and treatment present great challenges. To improve the detection rate of NEPC and prolong patient survival, many researchers have investigated the use of relevant radiopharmaceuticals as targeted molecular probes for the detection and treatment of NEPC lesions, including DOTA-TOC and DOTA-TATE for somatostatin receptors, 4A06 for CUB domain-containing protein 1, and FDG. This review focused on the specific molecular targets and various radionuclides that have been developed for PCa in recent years, including those mentioned above and several others, and aimed to provide valuable up-to-date information and research ideas for future studies.

Ultrasonographic Indeterminate Lymph Nodes in Preoperative Thyroid Cancer Patients: Malignancy Risk and Ultrasonographic Findings Predictive of Malignancy

  • Roh-Eul Yoo;Ji-hoon Kim;Jeong Mo Bae;Inpyeong Hwang;Koung Mi Kang;Tae Jin Yun;Seung Hong Choi;Chul-Ho Sohn;Jung Hyo Rhim;Sun-Won Park
    • Korean Journal of Radiology
    • /
    • v.21 no.5
    • /
    • pp.598-604
    • /
    • 2020
  • Objective: Proper management of lymph nodes (LNs) with ultrasonographic (US) indeterminate features in thyroid cancer patients remains elusive. We aimed to evaluate the malignancy risk and US findings predictive of malignancy for US indeterminate LNs in preoperative thyroid cancer patients through node-by-node correlation. Materials and Methods: A total of 348 LNs in 284 thyroid cancer patients, who underwent fine-needle aspiration or core-needle biopsy between December 2006 and June 2015, were included. We determined the malignancy risks for US probably benign, indeterminate, and suspicious categories. For US indeterminate LNs, which had neither echogenic hilum nor hilar vascularity in the absence of any suspicious finding, US findings were compared between benign and metastatic LNs using Mann-Whitney U test and Fisher's exact test. Results: US imaging diagnoses were probably benign in 20.7% (n = 72) cases, indeterminate in 23.6% (n = 82), and suspicious in 55.7% (n = 194). Malignancy risk of US indeterminate LNs (19.5% [16/82]) differed from those of the US probably benign (2.8% [2/72]) (p = 0.002) and US suspicious LNs (78.4% [152/194]) (p < 0.001). Among US indeterminate LNs, there were no significant differences in short, long, and long-to-short diameter (L/S) ratios between benign and metastatic LNs (3.9 vs. 3.8 mm, p = 0.619; 7.3 vs. 7.3 mm, p = 0.590; 1.9 vs. 1.9, p = 0.652). Conclusion: US indeterminate LNs were frequently encountered during preoperative evaluation and had intermediate malignancy risk. Given the lack of discriminative power of size criteria and L/S ratio, clinical factors such as surgical strategy and node size should be considered for proper triage of US indeterminate LNs in thyroid cancer.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Anthracofibrosis Mimicking Lung Cancer on CT: MR Imaging Findings (CT상 폐암과 유사하게 보이는 기관지 탄분 섬유화증의 자기공명영상 소견)

  • 류대식;이덕희;정승문;최수정;박성빈;박만수;강길현
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.18-23
    • /
    • 2001
  • Purpose : To describe the MRI findings in the bronchial anthracofibrosis mimicking lung cancer on CT examination. Materials and methods : Ten patients, who showed CT findings mimicking lung cancer, were selected among fifty patients of bronchial anthracofibrosis proven by bronchoscopic biopsy, consisting of two men and eight women, ranging in age from 58 to 79 years old faverage age, 68 years old). CT scan and MRI were performed in all patients (n=10). Percutaneous lung biopsy on mass was performed in one patient. MRI findings were analyzed with the emphasis on the signal intensity of the mass (n=4), collapsed lung (n=4) and Iymph node (n=10) on axial T1 and T2-weighted images by two radiologists in consensus. No contrast enhancement was used in all cases. Results : CT scan revealed mass (n=4), atelectasis with obstructive pneumonia(n=4) and bronchial wall thickening(n=2). All patients showed enlarged medistinal Iymph nodes(n=10). The mass showed low signal intensity on T1WI and T2WI (n =4). The collapsed lung in patients with atelectasis indicated intermediate signal intensity on T1WI and low signal intensity on T2WI (n= 4). Nine patients showed low sisnal intensity of Iymph node on T1WI and T2WI, except one patient who showed central high signal intensity with peripheral rim of low signal intensity in right lower paratracheal llmph node on T2WI. Conclusion : Low signal intensity of a mass, collapsed lung, and lymph nodes on T2WI in anthracofibrosis patients may be helpful in differentiation of the lesion from lung cancer.

  • PDF

Immunoscintigraphy of Colorectal and Other Gastrointestinal Cancers with Radioactive Monoclonal Antibodies to CEA and CA 19-9 (대장직장암 및 기타 소화기암에서의 단세포군항체를 이용한 방사면역신티그라피의 진단)

  • Jang, Dae-Hwan;Choi, Duck-Joo;Lee, Bum-Woo;Park, Won;Han, Chang-Soon;Kim, Hak-San;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.22 no.1
    • /
    • pp.83-92
    • /
    • 1988
  • The cocktails of two $^{131}I$ labeled Monoclonal antibody (MCAB) (Anti CA 19-9 F$(ab')_2$ + Anti CEA $F(ab')_2$ fragment), which react specially, with human gastrointestinal cancers, were administered to 10 patients with colorectal (7), stomach(2) and pancreas(1) cancer for scintigraphic detection. All patients were known or postoperatively recurrent cases, and serum tumor markers, CA 19-9 and CEA, were measured with immunoradiometric assay, just before immunoscintigraphy (ISG). The tumor marker's level in serum is not correlated with positive tumor uptake in ISG. The sensitivity and specificity of ISG in detection of 21 tumor sites, based on surgery, CT, ultrasonography and pathology, were 90.5% and 100% One case of colon cancer showed gall bladder metastasis, which was neglected on CT study. Tumor/non tumor uptake ratio of radiolabelled antibody were progressively increased from day 3 to day 7 during study. We summerized as follows 1) The use of cocktails of CEA and CA 19-9 MCAB $F(at')_2$ increased sensitivity and specificity in ISG. 2) Delayed imaging (later than 5 days) increases sensitivitv and specificity due to exclusion of nonspecific iodine accumulation in stomach and lung. 3) Second tracer technique is essential for anatomical landmark by use of a double isotope scan, but subtraction technique, a possible source of artifacts, is no longer necessory when delayed imaging is performed. 4) It may be possible to use two MCAB cocktails of CA 19-9 and CEA in Radioimmunodetection of stomach and pancreas cancer. In conclusion, ISG using MCAB cocktails, $F(ab')_2$ fragment of anti CA 19-9 and Anti CEA, provide additional opportunity for tumor localization and detection of colorectal and other G-I cancer, such as stomach and pancreas.

  • PDF

The useage of the EPID as a QA tools (EPID의 적정관리 도구로서의 유용성에 관한 연구)

  • Cho Jung Hee;Bang Dong Wan;Yoon Seong Ik;Park Jae Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.16-21
    • /
    • 1999
  • Purpose : The aim of this study is to conform the possibility of the liquid type EPID as a QC tools to clinical indication and of replacement of the film dosimetry. Aditional aim is to describe a procedure for the use of a EPID as a physics calibration tool in the measurements of radiation beam parameters which are typically carried out with film. Method & Materials : In this study we used the Clinac 2100c/d with EPID. This system contains 65536 liquid-filled ion chambers arranged in a $256{\times}256$ matrix and the imaging area is $32.5{\times}32.5cm$ with liquid layer thickness of 1mm. The EPID was tested for different field sizes under typical clinical conditions and pixel values were calibrated against dose by producing images using various thickness of lead attenuators(lead step wedge) using 6 & 10MV x-ray. We placed various thickness of lead on the table of linear accelerator and set the portal vision an SDD of 100cm. To acquire portal image we change the field size and energy, and we recorded the average pixel value in a $3{\times}3$ pixel region of interest(ROI) at field center was recorded. The pixel values were also measured for different field sizes in order to evaluate the dependence of pixel value on x-ray energy spectrum and various scatter components. Result : The EPID, as a whole, was useful as a QA tool and dosimetry device. In mechanical check, cross-hair centering was well matched and the error was less than ?2mm and light/radiation field coincidence was less than 1mm also. In portal dosimetry the wider the field size the the higher the pixel value and as the lead thickness increase, the pixel value was exponentially decreased. Conclusions : The EPID was very suitable for QA tools and it can be used to measure exit dose during patients treatment with reasonable accuracy. But when indicate the EPID to clincal study deep consideration required

  • PDF

Clinical, Laboratory Biomarkers and Imaging Findings of Pancreatic Adenocarcinoma in Iran

  • Hadizadeh, Mohammad;Padashi, Maryam;Alizadeh, Amir Houshang Mohammad;Zali, Mohammad Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.10
    • /
    • pp.4349-4352
    • /
    • 2014
  • Background: Pancreatic cancer has a high mortality rate because it is usually diagnosed late. Since little is known about this cancer in Iran, with the aim of improving this knowledge deficiency, we evaluated clinical, laboratory biomarkers, imaging findings and treatment modalities in Iranian patients with pancreatic adenocarcinoma. Materials and Methods: 131 cases of pancreatic adenocarcinoma in 2010-2013 were obtained from the Taleghani Hospital Record Department. Cases confirmed by histopathology from CT-guided biopsy, EUS-FNA and surgery examination were included. We excluded those with incomplete medical records. Results: The study included 131 subjects between 24 and 97 years of age and a mean age of $63{\pm}13.4$ years. Eighty (61.1%) were male and 51 (38.9%) female. Previous history included diabetes mellitus in 36 (27.5%), alcohol drinking in 5 (3.9%), smoker in 28 (21.4%) and opium addiction in 13 (10%). The common presenting history included weight loss in 79 (60.3%), abdominal pain in 77 (58.8%), fever in 11 (8.4%), nausea in 30 (22.9%), jaundice in 72 (55%), pruritus in 52 (39.7) and anemia in 33 (25.2%). CA19-9 levels with cut offs of 50, 100 and 200 U/ml were increased in 81%, 72% and 66% of patients, respectively. Tumor staging was: stage I, 3 (2.3%); stage II, 10 (7.6%); stage III, 58 (44.3%); and stage IV, 60 (45.8%). From 45 patients, 17 received ERCP inserted metallic stents and 22 plastic stents, the remaining 6 failed that PTC was done. Whipple surgery and chemotherapy were conducted for 10 and 29 patients, respectively. Conclusions: This disease affected older people and there was a male preponderance. The commonest risk factors were diabetes mellitus, smoking and cholelithiasis. The majority of patients presented with loss of appetite, loss of weight, jaundice, abdominal pain and discomfort. Almost all presented at late stages of the disease so that curative surgery was impossible. Also chemotherapy was only performed in a few patients as a neoadjuant treatment.

Suggestion for a New Grading Scale for Radiation Induced Pneumonitis Based on Radiological Findings of Computerized Tomography: Correlation with Clinical and Radiotherapeutic Parameters in Lung Cancer Patients

  • Kouloulias, Vassilios;Zygogianni, Anna;Efstathopoulos, Efstathios;Victoria, Oikonomopoulou;Christos, Antypas;Pantelis, Karaiskos;Koutoulidis, Vassilios;Kouvaris, John;Sandilos, Panagiotis;Varela, Maria;Aytas, Ilknur;Gouliamos, Athanasios;Kelekis, Nikolaos
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.2717-2722
    • /
    • 2013
  • Background: The objective of this research is the computed axial tomography (CT) imaging grading of radiation induced pneumonitis (RP) and its correlation with clinical and radiotherapeutic parameters. Materials and Methods: The chest CT films of 20 patients with non-small cell lung cancer who have undergone threedimensional conformal radiation therapy were reviewed. The proposed CT grading of RP is supported on solely radiological diagnosis criteria and distinguishes five grades. The manifestation of RP was also correlated with any positive pre-existing chronic obstructive pulmonary disease (COPD) history, smoking history, the FEV1 value, and the dosimetric variable V20. Results: The CT grading of RP was as follows: 3 patients (15%) presented with ground glass opacity (grade 1), 9 patients (45%) were classified as grade 2, 7 patients (35%) presented with focal consolidation, with or without elements of fibrosis (grade 3), and only one patient (5%) presented with opacity with accompanying atelectasis and loss of pulmonary volume (grade 4). Both univariate and multivariate analysis revealed as prognostic factors for the radiological grading of RP the reduction of FEV1 and the V20 (P=0.026 and P=0.003, respectively). There was also a significant (P<0.001) correlation of radiological grading of RP with FEV1 and V20 (spearman rho 0.92 and 0.93, respectively). Conclusions: The high correlation of the proposed radiological grading with the FEV1 and the V20 is giving a satisfactory clinical validity. Although the proposed grading scale seems relevant to clinical practice, further studies are needed for the confirmation of its validity and reliability.

Comparison Analysis of Patient Specific Quality Assurance Results using portal dose image prediction and Anisotropic analytical algorithm (Portal dose image prediction과 anisotropic analytical algorithm을 사용한 환자 특이적 정도관리 결과 비교 분석)

  • BEOMSEOK AHN;BOGYOUM KIM;JEHEE LEE
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.15-21
    • /
    • 2023
  • Purpose: The purpose of this study is to compare the performance of the anisotropic analytical algorithm (AAA) and portal dose image prediction (PDIP) for patient-specific quality assurance based on electronic portal imaging device, and to evaluate the clinical feasibility of portal dosimetry using AAA. Subjects and methods: We retrospectively selected a total of 32 patients, including 15 lung cancer patients and 17 liver cancer patients. Verification plans were generated using PDIP and AAA. We obtained gamma passing rates by comparing the calculated distribution with the measured distribution and obtained MLC positional difference values. Results: The mean gamma passing rate for lung cancer patients was 99.5% ± 1.1% for 3%/3 mm using PDIP and 90.6% ± 5.8% for 1%/1 mm. Using AAA, the mean gamma passing rate was 98.9% ± 1.7% for 3%/3 mm and 87.8% ± 5.2% for 1%/1 mm. The mean gamma passing rate for liver cancer patients was 99.9% ± 0.3% for 3%/3 mm using PDIP and 96.6% ± 4.6% for 1%/1 mm. Using AAA, the mean gamma passing rate was 99.6% ± 0.5% for 3%/3 mm and 89.5% ± 6.4% for 1%/1 mm. The MLC positional difference was small at 0.013 mm ± 0.002 mm and showed no correlation with the gamma passing rate. Conclusion: The AAA algorithm can be clinically used as a portal dosimetry calculation algorithm for patientspecific quality assurance based on electronic portal imaging device.

  • PDF