Immunoscintigraphy of Colorectal and Other Gastrointestinal Cancers with Radioactive Monoclonal Antibodies to CEA and CA 19-9

대장직장암 및 기타 소화기암에서의 단세포군항체를 이용한 방사면역신티그라피의 진단

  • Jang, Dae-Hwan (Department of Internal Medicine, National Medical Center) ;
  • Choi, Duck-Joo (Department of Internal Medicine, National Medical Center) ;
  • Lee, Bum-Woo (Department of Internal Medicine, National Medical Center) ;
  • Park, Won (Department of Internal Medicine, National Medical Center) ;
  • Han, Chang-Soon (Department of Internal Medicine, National Medical Center) ;
  • Kim, Hak-San (Department of Internal Medicine, National Medical Center) ;
  • Kim, Chong-Soon (Department of Nuclear Medicine, National Medical Center)
  • Published : 1988.05.25

Abstract

The cocktails of two $^{131}I$ labeled Monoclonal antibody (MCAB) (Anti CA 19-9 F$(ab')_2$ + Anti CEA $F(ab')_2$ fragment), which react specially, with human gastrointestinal cancers, were administered to 10 patients with colorectal (7), stomach(2) and pancreas(1) cancer for scintigraphic detection. All patients were known or postoperatively recurrent cases, and serum tumor markers, CA 19-9 and CEA, were measured with immunoradiometric assay, just before immunoscintigraphy (ISG). The tumor marker's level in serum is not correlated with positive tumor uptake in ISG. The sensitivity and specificity of ISG in detection of 21 tumor sites, based on surgery, CT, ultrasonography and pathology, were 90.5% and 100% One case of colon cancer showed gall bladder metastasis, which was neglected on CT study. Tumor/non tumor uptake ratio of radiolabelled antibody were progressively increased from day 3 to day 7 during study. We summerized as follows 1) The use of cocktails of CEA and CA 19-9 MCAB $F(at')_2$ increased sensitivity and specificity in ISG. 2) Delayed imaging (later than 5 days) increases sensitivitv and specificity due to exclusion of nonspecific iodine accumulation in stomach and lung. 3) Second tracer technique is essential for anatomical landmark by use of a double isotope scan, but subtraction technique, a possible source of artifacts, is no longer necessory when delayed imaging is performed. 4) It may be possible to use two MCAB cocktails of CA 19-9 and CEA in Radioimmunodetection of stomach and pancreas cancer. In conclusion, ISG using MCAB cocktails, $F(ab')_2$ fragment of anti CA 19-9 and Anti CEA, provide additional opportunity for tumor localization and detection of colorectal and other G-I cancer, such as stomach and pancreas.

Keywords