• Title/Summary/Keyword: Camera Performance

Search Result 1,814, Processing Time 0.027 seconds

EVALUATION OF CAMERA PERFORMANCE USING ISO-BASED CRITERIA

  • Ko, Kyung-Woo;Park, Kee-Hyon;Ha, Yeong-Ho
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.76-79
    • /
    • 2009
  • This paper investigates the performance of a vehicular rear-view camera through quantifying the image quality based on several objective criteria from the ISO (International Organization for Standardization). In addition, various experimental environments are defined considering the conditions under which a rear-view camera may need to operate. The process for evaluating the performance of a rear-view camera is composed of five objective criteria: noise test, resolution test, OECF (opto-electronic conversion function) test, color characterization test, and pincushion and barrel distortion tests. The proposed image quality quantification method then expresses the results of each test as a single value, allowing easy evaluation. In experiments, the performance evaluation results are analyzed and compared with those for a regular digital camera.

  • PDF

Effect of Die Bonding Epoxy on the Warpage and Optical Performance of Mobile Phone Camera Packages (모바일 폰 카메라 패키지의 다이 본딩 에폭시가 Warpage와 광학성능에 미치는 영향 분석)

  • Son, Sukwoo;Kihm, Hagyong;Yang, Ho Soon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • The warpage on mobile phone camera packages occurs due to the CTE(Coefficient of Thermal Expansion) mismatch between a thin silicon die and a substrate. The warpage in the optical instruments such as camera module has an effect on the field curvature, which is one of the factors degrading the optical performance and the product yield. In this paper, we studied the effect of die bonding epoxy on the package and optical performance of mobile phone camera packages. We calculated the warpages of camera module packages by using a finite element analysis, and their shapes were in good agreement showing parabolic curvature. We also measured the warpages and through-focus MTF of camera module specimens with experiments. The warpage was improved on an epoxy with low elastic modulus at both finite element analysis and experiment results, and the MTF performance increased accordingly. The results show that die bonding epoxy affects the warpage generated on the image sensor during the packaging process, and this warpage eventually affects the optical performance associated with the field curvature.

Insulation Performance Evaluation of Apartment Housing Using Infra-red Camera (적외선 열화상을 이용한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 -)

  • Choi, Bo-Hye;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.718-723
    • /
    • 2009
  • The purpose of this study is to present an in-site evaluation method for building insulation performance using Infra-red camera. The research contents of this study are to evaluate validity and suitability of building insulation defect survey using Infra-red camera for apartment housing with temperature & heat flow pattern analyze method. By establishing the in-site evaluation method building insulation performance using infra-red camera, it is expected that 1) building envelope repair market will be activated by using developed method in ESCO and remodeling companies, 2) the method developed in this research will contribute to reduce national energy consumption by promoting old building insulation remodeling.

  • PDF

HTF Algorithm for Evaluation of Lenses (렌즈 평가를 위한 MTF 알고리즘)

  • Song, Pil-Jae;Lee, Jong-Kue
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.403-406
    • /
    • 2006
  • Various cameras that is included digitial camera and portable individual terminal are supplied rapidly. Therefore, is trying for quality sophistication of camera that buy each camera manufacture. However, is selecting sample test way because there is no correct lens measurement method in mass production. This paper presents method to measure performance of lens to improve performance of camera. This paper presents method to measure performance of lens to improve performance of camera. As automation public prosecutor lens quality is correct and did quantification so that done measuring is possible. And processing designed possible MTF with high steed.

  • PDF

Investigation of a blind-deconvolution framework after noise reduction using a gamma camera in nuclear medicine imaging

  • Kim, Kyuseok;Lee, Min-Hee;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2594-2600
    • /
    • 2020
  • A gamma camera system using radionuclide has a functional imaging technique and is frequently used in the field of nuclear medicine. In the gamma camera, it is extremely important to improve the image quality to ensure accurate detection of diseases. In this study, we designed a blind-deconvolution framework after a noise-reduction algorithm based on a non-local mean, which has been shown to outperform conventional methodologies with regard to the gamma camera system. For this purpose, we performed a simulation using the Monte Carlo method and conducted an experiment. The image performance was evaluated by visual assessment and according to the intensity profile, and a quantitative evaluation using a normalized noise-power spectrum was performed on the acquired image and the blind-deconvolution image after noise reduction. The result indicates an improvement in image performance for gamma camera images when our proposed algorithm is used.

Performance Improvement Technique of Long-range Target Information Acquisition for Airborne IR Camera

  • Yang, Hyun-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.39-45
    • /
    • 2017
  • In this paper, we propose three compensation methods to solve problems in high-resolution airborne infrared camera and to improve long-range target information acquisition performance. First, image motion and temporal noise reduction technique which is caused by atmospheric turbulence. Second, thermal blurring image correction technique by imperfect performance of NUC(Non Uniformity Correction) or raising the internal temperature of the camera. Finally, DRC(Dynamic Range Compression) and flicker removing technique of 14bits HDR(High Dynamic Range) infrared image. Through this study, we designed techniques to improve the acquisition performance of long-range target information of high-resolution airborne infrared camera, and compared and analyzed the performance improvement result with implemented images.

Camera Acting Method (카메라 연기 훈련 방법 연구)

  • Park, Hoyoung
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.7
    • /
    • pp.70-79
    • /
    • 2013
  • The film language is distinguished roughly according to shot angles and size and camera movement. The film language is what the performer should be well-acquainted with in camera acting. Since the most important characteristics of acting in front of the camera lies in being with the camera, the relationship between the camera and the performers is basically mutual communication and is the inseparable relationship in which they should be well acquainted with each other. Understanding of diverse film languages for acting in front of the camera enables the performer to adapt to the media quickly and to concentrate on acting. Performance changes according to the media or environment in which acting is performed. For a good performance, the performers should be able to appropriately express their own acting according to the characteristics of the space or the media in which they do performance. Acting in front of the camera is clearly distinguished from acting on the stage in the aspects of either media characteristics or acting. With the manifestation of extemporaneousness and the discovery of the performers' personality to the extent possible, performers themselves proceed with creative works in collaboration with the director in acting in front of the camera and can attain the development of acting in front of the camera.

SNR Analysis for Practical Electro-Optical Camera System

  • Kim Youngsun;Kong Jong-Pil;Heo Haeng-Pal;Park Jong-Euk;Chang Young-Jun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.633-636
    • /
    • 2005
  • An electro-optical camera system consists of many subsystems such as the optics, the detector, and the electronics and so on. They may create variations in the processed image that were not present original scene. The performance analysis of the electro-optical camera system is a mathematical construct that provides an optimum design through appropriate trade off analysis. The SNR(Signal to Noise Ratio) is one of the most important performance for the electro-optical camera system. The SNR analysis shown in this paper is performed based on the practical high resolution satellite camera design. For the purpose of the practical camera design, the analysis assumes that the defined radiance, which is calculated for the Korean peninsula, reached directly to the telescope entrance. In addition, the actual operation concept such as integration time and the normal operation altitude is assumed. This paper compares the SNR analysis results according to the various camera characteristics such as the optics, the detector, and the camera electronics. In detail, the optical characteristics can be split into the focal length, F#, transmittance, and so on. And the system responsivity, the quantum efficiency, the TDI stages, the quantization noise and the analogue noise can be used for the detector and the camera electronics characteristics. Finally this paper suggests the optimum design to apply the practical electro-optical system.

  • PDF

Performance evaluation method of homogeneous stereo camera system for full-field structural deformation estimation

  • Yun, Jong-Min;Kim, Ho-Young;Han, Jae-Hung;Kim, Hong-Il;Kwon, Hyuk-Jun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.380-393
    • /
    • 2015
  • This study presents how we can evaluate stereo camera systems for the structural deformation monitoring. A stereo camera system, consisting of a set of stereo cameras and reflective markers attached on the structure, is introduced for the measurement and the stereo pattern recognition (SPR) method is utilized for the full-field structural deformation estimation. Performance of this measurement system depends on many parameters including types and specifications of the cameras, locations and orientations of them, and sizes and positions of markers; it is difficult to experimentally identify the effects of each parameter on the measurement performance. In this study, a simulation framework for evaluating performance of the stereo camera systems with various parameters has been developed. The maximum normalized root-mean-square (RMS) error is defined as a representative index of stereo camera system performance. A plate structure is chosen for an introductory example. Its several modal harmonic vibrations are generated and estimated in the simulation framework. Two cases of simulations are conducted to see the effects of camera locations and the resolutions of the cameras. An experimental validation is carried out for a few selected cases from the simulations. Using the simultaneous laser displacement sensor (LDS) measurements as the reference, the measurement errors are obtained and compared with the simulations.

Performance of CQUEAN camera

  • Choi, Chang-Su;Park, Won-Kee;Jeon, Yi-Seul;Pak, Soo-Jong;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.63.1-63.1
    • /
    • 2010
  • CQUEAN (Camera for QUasars in EArly uNiverse) is a newly developed camera system by CEOU optimized at 0.8 - $1.1{\mu}m$ wavelength region. From Aug. 10 to Aug. 17, 2010, the camera was installed at 2.1m Otto Struve telescope at McDonald Observatory, USA, and engineering test observation was performed. We obtained the data for the characteristics of camera and scientific purpose using 7 filters (g, r, i, z, Is, Iz, Y). For the purpose of discovery of z - 5~6 quasar, we specially used new filters (Is,Iz). During the test observation, we obtained the data of Gamma-Ray Burst, high redshift quasars, high redshift quasar candidates and other calibration data. We present general characteristics of the reduced data taken with CQUEAN and show the performance of the camera.

  • PDF