• 제목/요약/키워드: Cam Analysis

검색결과 596건 처리시간 0.03초

반응표면분석법을 이용한 VTR Deck 캠의 최적형상 설계 (Optimum Cam Profile Design of VTR Deck Using the Response Stuface Analysis)

  • 한형석;안형진;박태원
    • 대한기계학회논문집A
    • /
    • 제20권3호
    • /
    • pp.788-795
    • /
    • 1996
  • In this paper, and optimum profile of a cam being used in a VTR Deck mechanism is designed by the response surface analysis. The objective function of the design is to reduce driving torque of the pinch roller system that is used to compress video tape to the capstan motor axia. The pinch roller system that will be designed is modeled using the general purpopse mechanism analysis program DADS. The computer model is compared with the physical system for reliability. A model function to represent relationship between design variables and the objective function is estimated by the response surface analysis. Once the model function is reliably estimated the optimal design is carried out using the model function and each design variable's boundaries. To verify improvement of the pinch roller system, a prototype for the pinch rooler system is made and tested. From the test result, an optimum cam profile to resuce driving torque of the pinch roller system is verified.

치과용 캐드캠 시스템으로 제작된 고정성 보철물의 품질 분석 (Analysis of quality for fixed prostheses fabricated by dental CAD-CAM system)

  • 김원수;한만소;정재관;김기백
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.159-164
    • /
    • 2014
  • Purpose: The purpose of this study was analysis of quality of fixed prostheses fabricated by dental CAD/CAM system. Methods: The ten same cases of stone models were manufactured by dental scannable model, and stone models were scanned using the dental scanner for changing digital model. Ten digital models were completed. The design of zirconia core for zirconia based all-ceramic crown was conducted by the dental CAD program. The samples were fabricated using the pre-sintered zirconia block by dental milling machine. Marginal gaps were analyzed using by silicone replica technique at the eight parts for quality analysis of samples. One-way ANOVA was used for statistical analysis(${\alpha}=0.05$). Results: The mean for marginal gaps were $93.2{\sim}99.1{\mu}m$ at the eight parts. One-was ANOVA didn't show significant differences(p=0.089). Conclusion: The fixed dental prostheses fabricated by dental CAD/CAM were within clinically acceptable range.

토질공학적 해석방법에 의한 석탄회 폐기물지반의 안정처리에 관한 연구 -지반변형해석을 위한 Cam-clay model을 중심으로 (A Study on the Stabilization of Coal Ash Ground by Geotechnical Engineering Analysis Cam-clay model for Deformation Analysis of Coal Ash Ground)

  • 천병식
    • 한국지반공학회지:지반
    • /
    • 제14권1호
    • /
    • pp.81-92
    • /
    • 1998
  • 화력발전소에서 대량으로 부산 되어 폐기 처리되고 있는 석탄회 폐기물로 조성된 지반을 안정 처리하여 사용하거나 또는 이러한 석탄회를 건설공사의 직접적인 재료로 활용하게 되면 결국 폐자원을 산업자원화 함으로서 건설자재 난을 해소할 수 있게 된다. 본 연구에서는 석탄회를 성토재 및 매립재로서 대량 활용할 경우와 지반변형해석에 필요한 적용 모델과 그 적용성을 중심으로 검토하였다. 그 중 Cam-clay model은 흙의 다양한 응력경로에 대해 배수와 비배수 조건에서 재하하는 동 안 변위와 공극수압을 나타낼 수 있는 완전한 구성식을 제공하고, 필요로 하는 토질정수가 극소수이고 모든 것을 실내실험을 통해 측정할 수 있는 장점이 있다. 토질기본시험, 등방압밀 및 비배수 삼축압축시험 등을 통하여 Camflay mode숙 제반 parameter를 구하였고, 수치해석을 수행하여 시험 결과와 비교하였다. 시험 결과와 수치 해석결과에서 각각 구한 parameter의 오차는 매우 근소 한 것으로 나타났다. 시험을 통해 결정한 비회와 저회 5 : 5 적정혼합회의 Parameter들은 인공으로 조성된 석탄회 매립지반의 변형해석에서 Cam-clay model을 이용하는 데에 기초자료로서 활용이 가능할 것으로 판단된다.

  • PDF

An Optimization-based Computational Method for Surface Fitting to Update the Geometric Information of An Existing B-Rep CAD Model

  • Louhichi, Borhen;Aifaoui, Nizar;Hamdi, Mounir;BenAmara, Abdelmajid;Francois, Vincent
    • International Journal of CAD/CAM
    • /
    • 제9권1호
    • /
    • pp.17-24
    • /
    • 2010
  • For several years, researchers have focused on improving the integration of the CAD, CAM and Analysis through a better communication between the various analysis tools. This tendency to integrate the CAD/Analysis and automation of the corresponding processes requires data sharing between the various tasks using an integrated product model. We are interested in this research orientation to CAD/CAM/Analysis integration by rebuilding the CAD model (BREP), starting from the Analysis results (deformed mesh). Because this problem is complex, it requires to be split into several complementary parts. This paper presents an original interoperability process between the CAD and CAE. This approach is based on a new technique of rebuilding the CAD surface model (Nurbs, Bezier, etc.) starting from triangulation (meshed surface) as a main step of the BREP solid model. In our work, the advantages of this approach are identified using a centrifugal pump example.

충격분리 및 탄성변형을 포함한 캠-종동절 기구의 동역학적 해석을 위한 수치해석적 방법 (A numerical method for dynamic analysis of cam-follower mechanism including impact, separation and elastic deformation)

  • 이기수
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.519-528
    • /
    • 1998
  • A numerical method is presented for the dynamic analysis of cam and follower. Contact and separation between the cam and the follower are analyzed by imposing dynamic contact condition. The correct solution is obtained without spurious oscillation by imposing the velocity and acceleration constraints as well as the displacement constraint on the possible contact point. The constraints are satisfied by iteratively reducing the constraint errors toward zero, and a simple time integration of ordinary differential equation is employed for the solution of the equation of motion. The solution procedure associated with the iterative scheme is presented, and numerical simulations are conducted to demonstrate the accuracy of the solution.

Bi-arc법을 이용한 평면 캠의 정밀 가공 기술에 관한 연구 (A Study on Precision Machining Technology for Disk Cams using Bi-arc Method)

  • 신중호;권순만;조인영;김종찬;강한성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.235-236
    • /
    • 2006
  • The disk cam mechanism can produce a positive motion with relatively few components. This paper introduce a shape design of cam using the relative velocity method and a precision machining technology for using Bi-arc method. The paper gives a machining information at each point using the Bi-arc method and the analysis method of the cutting error due to the moving path of the cutter, so that we can lead to the optimum design in a disk cam mechanism.

  • PDF

단일 캠 구동기구의 동 안정성 해석 (Dynamic Stability Analysis of a Single Cam Drive Mechanism)

  • 김홍보;전혁수;이종원;박윤식
    • 대한기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.526-533
    • /
    • 1990
  • 본 연구에서는 단일 캠 구동기구의 안정성 해석을 위한 효율적인 방법이 제시 되고, 수치실험을 통하여 검증되었다. 우선 단일 캠 구동기구를 묘사하는 비선형 방 정식이 유도되고, 동안정성에 관여하는 변수들이 무차원화되어 도입된다. 유도된 방 정식은 캠 축의 입력각에 대하여 선형화되고, 선형화된 방정식에 조화균형법(harmonic balance method)을 적용하여 동안정성 해석을 수행하였다.

밸브 기구의 동특성을 고려한 캠 형상 설계에 관한 연구 (A Study on Optimum Cam Profile Extraction Considering Dynamic Characteristics of a Cam-Valve System)

  • 박경조;전혁수;박윤식
    • 대한기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.29-39
    • /
    • 1989
  • 본 논문에서는 우선 밸브 기구의 동적 특성을 보다 정교하게 묘사하기 위해서 4 자유도 집중 질량 모델을 세우고 시뮬레이션 결과와 실험 결과를 비교하여 실험을 더 잘 묘사할 수 있도록 모델을 개선하였다. 그리고 수립된 모델을 사용하여 밸브 변위, 속도, 가속도 특성 및 밸브 기구의 작동 오차를 정의하였다. 이 평균 자승 오차를 최소함으로써 중어진 캠 변위는 크게 변화시키지 않으면서 가속도 및 속도를 최소화한 캠을 설계하였다.

CAD/CAM을 이용하여 제작한 All-ceramic core의 변연 적합도 (ON THE MARGINAL FIDELITY OF ALL-CERAMIC CORE USING CAD/CAM SYSTEM)

  • 김동근;조인호;임주환;임헌승
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.20-34
    • /
    • 2003
  • Novel methods producing supplementary and prosthetic material by cutting or discharge processing via computer design have been proposed as alternatives for traditional casting methods and are being utilized for commercial purposes. The CAD/CAM system used in dentistry can be classified into three-dimensional input of target values, restoration design, and material processing. The marginal fidelity in production of In-Ceram core has important clinical implications and is a key consideration issue in CAD/CAM production as well. Through this research, the author arrived at the following conclusion aaer conducting comparison analysis of marginal fidelities between the In-Ceram core produced via CAD/CAM and that produced through the traditional method ; 1. In the cases of mesial, distal, and lingual margins, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 2. In the case of labial flange, the core margins via CAD/CAM produced lower values than those via the traditional method and the differences were found to be statistically significant. (p<0.05) 3. In comparision with overall marginal fidelity, the core margins via CAD/CAM produced lower values than those via the traditional method, but the differences were found to be statistically insignificant. 4. Among the core margins produced via the traditional method did not have statistically significant differences but fir those produced via CAD/CAM had statistically significant differences between labial and lingual sides and between labial and mesial sides. (p <0.05).