• 제목/요약/키워드: Calibration verification

검색결과 277건 처리시간 0.033초

척추 방사선수술 시 다엽콜리메이터 위치 오차의 임상적 위험성 평가 (Evaluation of Clinical Risk according to Multi-Leaf Collimator Positioning Error in Spinal Radiosurgery)

  • 강동진;오건;신영주;강진규;정재용;이보람
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.527-533
    • /
    • 2023
  • The purpose of this study is to evaluate the clinical risk of spinal radiosurgery by calculating the dose difference due to dose calculation algorithm and multi-leaf collimator positioning error. The images acquired by the CT simulator were recalculated by correcting the multi-leaf collimator position in the dose verification program created using MATLAB and applying stoichiometric calibration and Monte Carlo algorithm. With multi-leaf collimator positioning error, the clinical target volume (CTV) showed a dose difference of up to 13% in the dose delivered to the 95% volume, while the gross tumor volume (GTV) showed a dose difference of 9%. The average dose delivered to the total volume showed dose variation from -8.9% to 9% and -10.1% to 10.2% for GTV and CTV, respectively. The maximum dose delivered to the total volume of the spinal cord showed a dose difference from -14.2% to 19.6%, and the dose delivered to the 0.35 ㎤ volume showed a dose difference from -15.5% to 19.4%. In future research, automating the linkage between treatment planning systems and dose verification programs would be useful for spinal radiosurgery.

ICT 기반 환경모니터링 센서 데이터 검증을 위한 원스탑 플랫폼 (One-stop Platform for Verification of ICT-based environmental monitoring sensor data)

  • 채민아;조재혁
    • Journal of Platform Technology
    • /
    • 제9권1호
    • /
    • pp.32-39
    • /
    • 2021
  • 기존 환경측정기기는 전자파 및 친환경 제품 인증, 내구성 시험 위주이며, 센서 신뢰성 검증 및 측정 데이터에 대한 검증은 형식 승인 및 등록, 인수시험, 초기교정, 주기시험 등을 통해 센서 성능평가 위주로 수행된다. 본 플랫폼은 각 타겟 센서별 성능평가 뿐만 아니라 센서의 데이터 신뢰성에 대한 검증체계 지원 ICT 기반 환경 모니터링 센서 신뢰성 검증 체계를 구축하였다. 환경 정보에 대한 센서 데이터를 수집할 센서보드를 제작하였고 센서 및 데이터 신뢰성 평가 및 검증 서비스 체계를 규격화 하였다. 또한, ICT 기반 센서 데이터 신뢰성 평가 및 검증을 위해 LoRa 통신을 이용한 센서 데이터 플랫폼 모니터링 프로토타입을 제작하였고 이를 스마트 시티 등에 실증 테스트하였다. 해당 시스템을 통해 받은 데이터 분석을 위해 머신러닝을 이용하여 최적화 알고리즘 개발하였다. 이를 통해 신뢰성 검증을 위한 센서 빅데이터 분석시스템을 구축하였고 통합 평가 및 검증 시스템의 기반을 마련하였다.

분석툴을 이용한 천리안2A 기상탑재체 복사 보정 파라미터 검증 (Verification of GEO-KOMPSAT-2A AMI Radiometric Calibration Parameters Using an Evaluation Tool)

  • 진경욱;박진형
    • 대한원격탐사학회지
    • /
    • 제36권6_1호
    • /
    • pp.1323-1337
    • /
    • 2020
  • 천리안2A호 AMI(Advanced Meteorological Imager) 복사 보정에 대한 검증은 탑재체의 기능 및 성능 점검뿐만 아니라, 탑재체 자료의 품질을 결정 짓는 중요한 요소이다. AMI 탑재체는 여섯 개의 가시 및 근적외 채널과 10개의 열적외 채널로 구성되어 있다. 가시/근적외 채널의 복사 성능을 대표하는 핵심적인 파라미터로는 SNR(Signal-to-Noise Ratio), 열적외채널의 경우는 NEdT(Noise Equivalent delta Temperature)를 들 수 있다. 다이나믹 레인지와 검출기의 반응도와 관련된 Gain 값 또한 복사 보정 성능과 관련된 중요한 파라미터이다. AMI 탑재체의 주요 복사 보정 성능 검증을 위해, 실시간 AMI자료 처리 시스템과는 별도의 오프라인 복사 성능 분석 툴을 개발하였다. 개발된 분석 툴을 이용하여 천리안2A호 발사 후 궤도상 시험 기간 동안 검증 작업을 수행하였다. 분석 툴을 통한 계산 결과는 탑재체 개발업체인 HARRIS사의 분석 값과 비교 검증하였다. AMI 복사 성능 검증 작업은 총 세차례로 나누어 AMI탑재체 양쪽 면인 Side1과 Side2에 대해 이루어졌다. 복사 성능 검증 결과 주요 복사 보정 파라미터들의 성능은 요구조건 값들을 크게 상회하는 우수한 성능을 보여 주었으며, AMI 복사 성능 분석 툴의 유효성이 입증되었다.

광학식 모션캡처를 위한 다중 카메라 보정 방법 (Multi-camera Calibration Method for Optical Motion Capture System)

  • 신기영;문정환
    • 한국컴퓨터정보학회논문지
    • /
    • 제14권6호
    • /
    • pp.41-49
    • /
    • 2009
  • 본 논문에서는 광학식 모션캡처 장비를 위한 다중 카메라 보정 방법을 제안한다. 이 방법은 DLT(Direct linear transformation) 알고리즘을 이용하여 7개의 마커가 있는 3축 보정틀의 영상을 획득하여 1차 카메라 보정을 한다. 그리고 2개의 마커가 있는 보정봉을 측정하고자 하는 영역에서 움직여서 2차 카메라 보정을 실시한다. 1차 카메라 보정에서는 카메라 보정뿐만 아니라 렌즈 왜곡 계수를 계산하여 2차 카메라 보정에서의 최적화를 위한 초기해로 사용한다. 2차 카메라 보정에서는 보정봉에 있는 마커사이의 거리가 일정하기 때문에 계산된 마커 거리와 실제 마커 거리의 차가 최소화 되도록 최적화를 수행한다. 제안한 방법에 의한 다중 카메라 보정 방법을 검증하기 위하여 재투영에러를 계산하였고 3축 보정틀에 있는 마커사이의 거리와 보정봉에 있는 마커사이의 거리를 계산하여 다른 상용장비의 값과 비교하였다. 3축 보정틀에 있는 마커를 복원하여 에러를 비교한 결과 평균오차가 상용장비의 1.7042mm에 비해 0.8765mm로 51.4% 수준으로 나타났고, 보정봉에 있는 마커를 복원하여 에러를 비교한 결과 상용장비의 평균에러 1.8897mm에 비해 2.0183mm로 0.1286mm 크게 나타났다.

항공 카메라 검정을 위한 테스트 필드 구축방안 (Establishment of Test Field for Aerial Camera Calibration)

  • 이재원;윤종성;신진수;윤부열
    • 대한공간정보학회지
    • /
    • 제16권2호
    • /
    • pp.67-76
    • /
    • 2008
  • 최근 항공측량분야의 가장 큰 기술적 특징은 Camera 혹은 Lidar와 같은 주 센싱 장비에 GPS, IMU 등 다양한 위치결정 센서를 연계한 Direct Georeferencing 기술의 활용이다. 아울러 항측용 디지털 카메라의 기술적 우월성과 이의 활용성이 입증됨에 따라 다양한 종류의 항측용 디지털 카메라가 개발 및 보급되고 있다. 이에 부응하여 국내에서도 일반적인 항공촬영으로는 취득이 불가능한 건물측면과 비고가 큰 지형에서 발생하는 사각지역에 대하여도 3차원 정보취득과 Texture Mapping이 가능한 다각(Multi-looking)항공촬영시스템의 개발이 시도되고 있다. 하지만 다양한 센서 결합과 다중 카메라의 배열에 따른 센서들간의 시각동기화와 함께 정확한 기하 및 복사보정을 실시해야 하는 문제점이 따른다. 이를 해결하기 위해서는 항공측량 시스템의 센서검정(Sensor Calibration)에 필요한 테스트 필드가 절실히 요구되고 있다. 따라서 본 연구에서는 항공측량용 테스트 필드 구축과 관련한 국외 사례를 고찰하고 국내 테스트 필드 구축방안을 제시하고자 한다.

  • PDF

장단기유출 양용저유 탱크 모델의 개발에 관한 연구 (II) (Studies on the Development of Storage Tank Model for both Long and Short Terms Runoff (II))

  • 이순혁;박명근
    • 한국농공학회지
    • /
    • 제33권2호
    • /
    • pp.51-60
    • /
    • 1991
  • The main objective of this study is to examine the adaptability for the large watershed of the storage tank model which can be applied for the analysis of both long and short terms runoff developed on the basis of hydrologic data for a smaH mountaineous watershed. The results obtained in this study are summarized as follows ; 1. Areal rainfalls of the Dae Chong watershed were calculated by Thiessen method composed of 9 Thiessen networks. 2. Optimal parameters for two types, Model A and Model B of tank models were derived through calibration procedure by standardized Powell method. 3. Monthly simulated flows of Model B are seemed to be closer to the monthly observed than those of Model A during calibration period in the long terms runoff. 4. Relative errors for the simulated flood flows of Model B were apperaed as lower percentage to the observed than those of Model A during calibration period in the short terms runoff. 5. Daily simulated hydrographs of Model B are seemed to be closer to the daily observed than those of Model A during verification period in the long terms runoff. Significance of Model B was highly acknowledged in comparison with Model A in the correlation analysis between annual observed and annual simulated runoff. 6. Reproducibility of simulated flows for Model B is generally seemed to be better than that of Model A during calibration period in the short terms runoff. 7. It can be concluded that reproducibility of Model B is superior to that of Model A in the long and short terms runoff even a large watershed like the result of the small one. 8. It was verified that adaptability for the large watershed of Model B is superior to that of Model A between the two models which were developed by a small watershed characteristics for both long and short terms runoff. 9. Further study for getting a suitable tank model is desirable to be established by the decision, calibration method of initial parameters of tank model and by additional application of another watershed with different watersheds and meterological characteristics.

  • PDF

Development of a Vision-based Position Estimation System for the Inspection and Maintenance Manipulator of Steam Generator Tubes a in Nuclear Power Plant

  • Jeong, Kyung-Min;Cho, Jae-Wan;Kim, Seung-Ho;Kim, Seung-Ho;Jung, Seung-Ho;Shin, Ho-Chul;Choi, Chang-Whan;Seo, Yong-Chil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.772-777
    • /
    • 2003
  • A vision-based tool position estimation system for the inspection and maintenance manipulator working inside the steam generator bowl of nuclear power plants can help human operators ensure that the inspection probe or plug are inserted to the targeted tube. Some previous research proposed a simplified tube position verification system that counts the tubes passed through during the motion and displays only the position of the tool. In this paper, by using a general camera calibration approach, tool orientation is also estimated. In order to reduce the computation time and avoid the parameter bias problem in an ellipse fitting, a small number of edge points are collected around the large section of the ellipse boundary. Experiment results show that the camera calibration parameters, detected ellipses, and estimated tool position are appropriate.

  • PDF

샘플링 오실로스코프의 주파수 응답특성 교정 (Calibration of Frequency Response for a Sampling Oscilloscope)

  • 조치현;이동준;이주광
    • 한국전자파학회논문지
    • /
    • 제29권5호
    • /
    • pp.344-352
    • /
    • 2018
  • 본 논문에서는 샘플링 오실로스코프의 주파수 응답특성을 측정하는 방법을 제안하였다. 제안된 방법은 샘플링 오실로스코프의 계통오차인 시간축 왜곡 현상과 임피던스 부정합에 의한 영향을 교정할 수 있다. 또한 시간축 에러를 교정한 후에 발생하는 잔여 지터와 기준 펄스 발생 조건에 따라 변하는 scale factor의 정확한 추정이 가능하다. 제안 방법의 불확도 분석을 수행하였고, 전력계와의 비교 검증을 통해 제안 방법의 타당성을 보였다.

1차원 수질 예측 모형의 검보정 자동화 시스템 개발 및 낙동강에서의 적용 (Development of 1-Dimensional Water Quality Model Automatizing Calibration-Correction and Application in Nakdong River)

  • 손아롱;한건연;박경옥;김병현
    • 환경영향평가
    • /
    • 제20권5호
    • /
    • pp.765-777
    • /
    • 2011
  • According to the total pollution load management system, exact prediction and analysis of water quality and discharge has been required in order to allocate the amount of pollution load to each local government. In this study, QUAL2E model was used for comparison with other water quality models and improve the inadequate to forecast future water quality. And Various calibration and verification methods were applied to deal with existing uncertainties of parameter during modeling water quality. For user convenience, A GUI(Graphical User Interface) system named "QL2-XP" model is developed by object-oriented language for the user convenience and practical usage. Suggested GUI system consist of hydraulic analysis, water quality analysis, optimized model calibration processes, and postprocessing the simulation results. Therefore this model will be effectively utilized to manage practical and efficient water quality.

원격지에서 모노펄스 레이더의 주파수 위상 교정을 위한 독립된 펄스반복주파수 생성 및 제어 (Independent PRF Generation and Control for Frequency Phase Calibration on Mono-pulse Radar at a Remote Location)

  • 양재원;유승오;윤재혁;이동주
    • 한국군사과학기술학회지
    • /
    • 제24권4호
    • /
    • pp.368-373
    • /
    • 2021
  • This paper presents a method of independent pulse repetition frequency(PRF) generation and control for frequency phase calibration on mono-pulse radar at a remote location. In order to generate an independent PRF signal of 320[Hz], pulse width modulation(PWM) of 16-bit timer/counter was applied. For a precision control of PRF signal, 16-bit timer/counter interrupt was changed for each period. Therefore, average frequency of PRF could be controlled by 0.0001[Hz]. To calibrate a frequency phase of mono-pulse radar at a remote location, the proposed PRF generator with a precision control of frequency was used regardless of receiving PRF signal from a radar. For the verification of the proposed PRF generator, theoretical analysis and experimental results are included.