DOI QR코드

DOI QR Code

Multi-camera Calibration Method for Optical Motion Capture System

광학식 모션캡처를 위한 다중 카메라 보정 방법

  • Published : 2009.06.30

Abstract

In this paper, the multi-camera calibration algorithm for optical motion capture system is proposed. This algorithm performs 1st camera calibration using DLT(Direct linear transformation} method and 3-axis calibration frame with 7 optical markers. And 2nd calibration is performed by waving with a wand of known length(so called wand dance} throughout desired calibration volume. In the 1st camera calibration, it is obtained not only camera parameter but also radial lens distortion parameters. These parameters are used initial solution for optimization in the 2nd camera calibration. In the 2nd camera calibration, the optimization is performed. The objective function is to minimize the difference of distance between real markers and reconstructed markers. For verification of the proposed algorithm, re-projection errors are calculated and the distance among markers in the 3-axis frame and in the wand calculated. And then it compares the proposed algorithm with commercial motion capture system. In the 3D reconstruction error of 3-axis frame, average error presents 1.7042mm(commercial system) and 0.8765mm(proposed algorithm). Average error reduces to 51.4 percent in commercial system. In the distance between markers in the wand, the average error shows 1.8897mm in the commercial system and 2.0183mm in the proposed algorithm.

본 논문에서는 광학식 모션캡처 장비를 위한 다중 카메라 보정 방법을 제안한다. 이 방법은 DLT(Direct linear transformation) 알고리즘을 이용하여 7개의 마커가 있는 3축 보정틀의 영상을 획득하여 1차 카메라 보정을 한다. 그리고 2개의 마커가 있는 보정봉을 측정하고자 하는 영역에서 움직여서 2차 카메라 보정을 실시한다. 1차 카메라 보정에서는 카메라 보정뿐만 아니라 렌즈 왜곡 계수를 계산하여 2차 카메라 보정에서의 최적화를 위한 초기해로 사용한다. 2차 카메라 보정에서는 보정봉에 있는 마커사이의 거리가 일정하기 때문에 계산된 마커 거리와 실제 마커 거리의 차가 최소화 되도록 최적화를 수행한다. 제안한 방법에 의한 다중 카메라 보정 방법을 검증하기 위하여 재투영에러를 계산하였고 3축 보정틀에 있는 마커사이의 거리와 보정봉에 있는 마커사이의 거리를 계산하여 다른 상용장비의 값과 비교하였다. 3축 보정틀에 있는 마커를 복원하여 에러를 비교한 결과 평균오차가 상용장비의 1.7042mm에 비해 0.8765mm로 51.4% 수준으로 나타났고, 보정봉에 있는 마커를 복원하여 에러를 비교한 결과 상용장비의 평균에러 1.8897mm에 비해 2.0183mm로 0.1286mm 크게 나타났다.

Keywords

References

  1. J. L. Garrido Castro, R. Medina-Carnicer, Alfonso Martinez Galisteo, "Design and evaluation of a new three-dimensional motion capture system based on video," Gait & Posture, Vol. 24, No. 1, pp. 126-129, August 2006. https://doi.org/10.1016/j.gaitpost.2005.08.001
  2. 임윤빈, 조육, 허복희, "자기적 방법을 이용한 3차원 좌표측정," 한국자기학회지, 제 12권, 제6호, 206-211쪽, 2002년 12월.
  3. S. Hashi, M. Toyoda, S. Yabukami, K. Ishiyama, Y. Okazaki, and K.I. Arai, "Wireless magnetic motion capture system for multi-marker detection," IEEE transactions on magnetics, Vol. 42, No. 10, pp. 3279-3281, October 2006. https://doi.org/10.1109/TMAG.2006.880737
  4. T. Jan-Phillip and L. Jorn, "A mobile low-cost motion capture system based on accelerometers," Lecture notes in computer science, Vol. 4292, pp. 437-446, October 2006. https://doi.org/10.1007/11919629_45
  5. Inition, http://www.inition.co.uk
  6. 최태준, 유석호, 이동열, 이완복, "광학식 모션 캡쳐방식을 이용한 디지털 캐릭터 움직임," 한국콘텐츠학회논문지, 제 7권, 제 8호, 109-116쪽, 2007년 8월.
  7. Vicon, http://www.vicon.com
  8. Qualisys, http://www.eualisys.com
  9. Optitrack, http://www.naturalpoint.com/optitrack
  10. 안정현, 설창환, 박은광, 원광연, "LAN기반 광학식 모션 캡처 시스템 개발," HCI2000 학술대회, 429-432쪽, 2000.
  11. 차정희, 이근수, "불변 특징모델을 이용한 카메라 동작인수 측정," 한국컴퓨터정보학회논문지, 제 10권, 제 4호, 191-201쪽, 2005년 9월.
  12. 강동중, "여러 장의 영상을 사용하는 3차원 계측용 카메라 교정방법," 제어.자동화.시스템공학논문지, 제 13권, 제 3호, 224-229쪽, 2007년 3월.
  13. D. J. Kang, J. E. Ha, and M. H. Jeong, "Detection of calibration patterns for camera calibration with irregular lighting and complicated backgrounds," International journal of control, automation, and systems, Vol. 6, No. 5, pp.746-754, October 2008.
  14. A. Kalahi, Mo. Hoviattalab, T. Rezaeian, M. Alizadeh, M. Bostan, H. Mokhtarzadeh, "Design of a marker-based human motion tracking system," Biomedical signal processing and control, Vol. 2, No. 1, pp.59-67, January 2007. https://doi.org/10.1016/j.bspc.2007.02.001
  15. T. Pribanic, P. Strum and M. Cifrek, "Calibration of 3D kinematic systems using orthogonality constraints," Machine vision and applications, Vol. 18, No. 6, pp.367-381, November 2007. https://doi.org/10.1007/s00138-007-0068-0
  16. Y. I. Abdel-Aziz & H. M. Karara, "Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry," Proceedings of the Symposium on close-range photogrammetry, Falls church, VA: American society of photogrammetry, pp.1-18, 1971.
  17. O. D. Faugeras and G. Toscani, "Camera calibration for 3D computer vision," Proc. international workship on industrial applications of machine vision and machine intelligence, Silken, Japan, pp.240-247, 1987.
  18. R. I. Hartley, "Estimation of relative camera positions for uncalibrated cameras," Lecture notes in computer science, vol. 588, pp. 579-587, May 1992.
  19. J.S. Walton, "Close-range cine-photogrammetry: a generalized technique for quantifying gross human motion". Ph.D. Dissertation, Pennsylvania State University, University Park, 1981.
  20. H. Hatze, "High-precision three-dimensional photogrammetric calibration and object space reconstruction using a modified DLT-approach," J. Biomech., Vol. 21, Issue 7, pp.533-538. 1988. https://doi.org/10.1016/0021-9290(88)90216-3
  21. L. Quan and S. Hang, "Correction of the asymmetrical circular projection in DLT camera calibration," Congress on image and signal processing, Vol. 2, pp.344-348, May 2008.
  22. T. Svoboda, D. Martinec and T. Paidla, "A convenient multicamera self-calibration for virtual environments," Presence: teleoperators and virtual environments, Vol. 14, No. 4, pp. 407-422, August 2005. https://doi.org/10.1162/105474605774785325
  23. Z. Chuan, T. Dalong and G. Hogwei, "A high-precision calibration and optimization method for stereo vision system," 9th International conference on control, automation, robotics and vision, pp. 1-5, December 2006.