• 제목/요약/키워드: Calibration uncertainty

검색결과 347건 처리시간 0.027초

Uncertainty Evaluation of a multi-axis Force/Moment Sensor

  • Kim, Gab-Soon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제3권3호
    • /
    • pp.5-11
    • /
    • 2002
  • This paper describes the methods for calibration and evaluation of the relative expanded uncertainty of a multi-axis force/moment sensor. In order to use the sensor in the industry, it should be calibrated and its relative expanded uncertainty should be also evaluated. At present, the confidence of the sensor is shown with only interference error. However, it is not accurate, because the calibrated multi-axis force/moment sensor has an interference error as well as a reproducibility error of the sensor, etc. In this paper, the methods fur calibration and for evaluation of the relative expanded uncertainty of a multi-axis force/moment sensor are newly proposed. Also, a six-axis force/moment sensor is calibrated with the proposed calibration method and the relative expanded uncertainty is evaluated using the proposed uncertainty evaluation method and the calibration results. It is thought that the methods fur calibration and evaluation of the uncertainty can be usually used for calibration and evaluation of the uncertainty of the multi-axis force/moment sensor.

고정밀 전기식 힘측정기의 불확도평가 절차 및 응용 (Procedure for Uncertainty Evaluation of a Precision Electric Force Measuring Device and Its Application)

  • 김갑순;강대임
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.161-167
    • /
    • 1999
  • This paper describes the calibration method and the calculation equations of expanded uncertainty for a precision electric force measuring device. The calibration of the electric force measuring device is performed three times (0 ${\circ}$(first time), $120{\circ}$(second time), $240{\circ}$(third time)) at each calibration point. It is usually selected ten points from zero load to rated load of the electric force measuring device. The expanded uncertainty is calculated by combining A type standard uncertainty and B type standard uncertainty. The calibration method and the calculation equations of expanded uncertainty can be widely used in the calibration of the precision electric force measuring device.

  • PDF

6분력 힘/모멘트 교정기의 설계 및 불확도 평가 (Design and Evaluation of Uncertainty for 6-component Force/Moment Calibration Machine)

  • 김갑순;강대임;송후근
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.68-72
    • /
    • 1997
  • This paper presents the design and the evaluation of the 6-component force/moment calibration machine which h a s t h e maximum capacities of 500 N in forces and 50 Nm in moments. This calibration machine consists of body. fixture. force generating system, moment generating system. The expanded uncertainty of the calibration machine is evaluated by calculating the A type uncertainty. $U_A$ and B type uncertainty, $U_B$. The evaluation results. this system has the expanded uncertainty of less than $2{\times}10^[-2]$ in respective force and moment components.

  • PDF

30 MHz에서 1 GHz 대역 EMI 측정용 다이폴안테나 교정의 측정 불확도 (Measurement Uncertainty for Calibration of EMI Dipole Antenna from 30 MHz to 1 GHz)

  • 박정규;정동찬;조진영
    • 한국전자파학회논문지
    • /
    • 제18권2호
    • /
    • pp.166-176
    • /
    • 2007
  • 측정 분야나 교정 분야에서 측정 불확도를 보고하는 것은 매우 중요하다. 정보통신부 전파연구소에서는 EMI 측정 시험소를 위하여 안테나 교정 서비스를 제공하고 있는데, 안테나 교정의 정확성은 측정 불확도 평가로 집약되어, EMI 시험의 신뢰성을 판가름하는 시금석이 된다. EMI에 관한 국제기구인 CISPR에서는 2005년 말에 안테나 교정에 대한 최초의 표준 초안인 CISPR/A/644/C를 내놓았다. 이 초안은 안테나교정 및 관련된 측정 불확도를 포함하고 있다. 본 논문에서는 이 문서를 근간으로 전파연구소 이천의 안테나 교정시험장에서 EMI용 다이폴안테나를 교정할 때의 측정 불확도를 산출하였다. 전파연구소의 안테나 교정 방법은 자유 공간 안테나 인자를 측정하는 3-안테나의 height scanning averaging 법으로서, 본 방법에 의하여 안테나가 교정될 때 측정 결과에 영향을 미칠 수 있는 모든 불확도 요인을 고려하였다.

다축 힘/모멘트센서의 불확도평가 및 응용에 관한 연구 (Uncertainty Evaluation of a Multi-axis Force/Moment Sensor and Its Application)

  • 김갑순
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.177-180
    • /
    • 2001
  • This paper describes the calibration method and the evaluation method of relative expanded uncertainty for a multi-axis force/moment sensor. This sensor should be calibrated to be use in the industry. Now, the confidence of the calibration result is expressed with interference error. But it is no inaccurate, because an interference error, besides, a reproducibility error of the sensor, a error of this six-axis force/moment sensor calibrator, and so on. Thus, in order to accurately evaluate the relative expanded uncertainty of it, the concept of the uncertainty should be induced, and these errors must be contained in the relative expanded uncertainty. In this paper, the calibration method is exhibited and the evaluation method of the relative expanded uncertainty is also exhibited. And, a six-axis force/moment sensor was calibrated and the relative expanded uncertainty was evaluated.

  • PDF

CTD 교정 시스템 구축 및 불확도 평가 (Establishment of CTD Calibration System and Uncertainty Estimation)

  • 이정한;황근춘;김은수;이승훈
    • Ocean and Polar Research
    • /
    • 제36권1호
    • /
    • pp.77-85
    • /
    • 2014
  • The quality control of ocean observations data is becoming a major issue as real-time observational data and information services have increased recently. Therefore, it is necessary for oceanographic instruments to calibrate. In this paper, we first introduce the CTD calibration system and traceability. Next, CTD calibration procedures and estimation of uncertainty of measurement are described. The expanded uncertainty (k = 2) of the temperature, pressure and conductivity are 0.$0.003^{\circ}C$, $6.0{\times}10^{-5}$ and 0.006 mS/cm respectively. Finally, the excellence of CTD calibration and its measurement capability has been proven by comparing the inter-calibration result of KIOST and Sea-Bird Electronics (SBE). CTD calibration residuals are less than ${\pm}0.0001^{\circ}C$, ${\pm}0.001$ MPa, ${\pm}0.0001$ S/m for SBE 3plus temperature sensor, SBE 19plus pressure sensor and SBE 4C conductivity sensor respectively.

다축 힘/모멘트 센서 교정기의 개발 및 그의 불확도 평가 (Development of Calibration System for Multi-Axis Force/Moment Sensor and Its Uncertainty Evaluation)

  • 김갑순;윤정원
    • 한국정밀공학회지
    • /
    • 제24권10호
    • /
    • pp.91-98
    • /
    • 2007
  • This paper describes the development of the calibration system for a multi-axis force/moment sensor and its uncertainty evaluation. This calibration system can generate the continuous forces (${\pm}Fx,\;{\pm}Fy$ and ${\pm}Fz$) and moments (${\pm}Mx,\;{\pm}My$ and ${\pm}Mz$). Many kinds of multi-axis force/moment sensors in industries should be carried out the characteristic test or the calibration with the calibration system that can generate the forces and the moments. The calibration systems have been already developed are the disadvantages of the low capacity, the generation of step forces(10N, 20N ...) and step moments(1Nm, 2Nm ...) with weights, the high coasts in manufacture and so on. In this paper, the calibration system for a multi-axis force/moment sensor that can generate the continuous three forces and three moments was developed. Their ranges are $0{\sim}2000N$ in all force-directions and $0{\sim}400Nm$ in all moment-directions. And the system was evaluated in the expanded relative uncertainty. They were ${\pm}0.0004$ in all forces ${\pm}Fx,\;{\pm}Fy$ and ${\pm}Fz$, and ${\pm}0.0004$ in all moments ${\pm}Mx,\;{\pm}My$ and ${\pm}Mz$.

동력식 조립공구의 측정불확도 산출방법 개발 (Calibration Methods for Measurement Uncertainty of Power Assembly Tools)

  • 오세헌;강기영;홍민성
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.496-501
    • /
    • 2015
  • In this study, calibration procedure of power assembly tools is suggested and methods are developed for calculating measurement uncertainty. Fist of all, the calibration of joint simulator bench (JSB) was carried out for maintaining traceability and the uncertainty components of JSB were analyzed. The influences of tool speed, tolerance, temperature and length of the adapter were examined by the torque measurement values through experiments. From this research, credibility for calibration results could be enhanced. This experimental results, being used as an effective tool for calibration of power assembly tools, will provide and improve the accuracy of the use of the power assembly tools.

Site calibration이 풍력발전시스템 성능시험 불확도에 미치는 영향 연구 (A Study for the Effect on the Uncertainty of Power Performance Testing of Windturbine by a Site Calibration)

  • 김건훈;현승건
    • 한국태양에너지학회 논문집
    • /
    • 제31권2호
    • /
    • pp.107-112
    • /
    • 2011
  • A comparison study between two performance testing results, one is on the site calibration not needed and the other is needed, was proceeded for the understanding on the effect of site calibration on the complex terrain. As a result, it is revealed that all of uncertainty components is effected by the topographical features dramatically. And the maximum difference of uncertainty reached at around 8% of rated capacity of wind turbine. So, the site calibration is an effective method to remove the variable wind effect by the ground complexity and must be proceeded before the power performance testing of a wind turbine.