• 제목/요약/키워드: Calibration source

검색결과 383건 처리시간 0.04초

고성능 D/A 변환기를 위한 보정 기법 연구 (The research of calibration methods for High-performance D/A Converters)

  • 김수재;황정진;윤광섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.553-554
    • /
    • 2008
  • In a general way, Current scaling DACs are used in wireless communication systems. But there are degradations of important factors because of mismatch of current source corresponding to high resolution. To solve the problem, Calibration methods are researched lately. Mismatch of current source is corrected by Calibration method and then corrected current values are delivered to Core DAC. As a results, Degradations of important factors that produced by increment of non-linearity are suppressed by calibration method.

  • PDF

소음계 교정 자동화 시스템 개발 및 성능평가 (Development and Performance of Automated Calibration System of Sound Level Meters)

  • 김용태;조문재;이용봉;서재갑
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

모노펄스 레이다용 다채널 집적 수신기의 수신 채널 보정 (Receiving Channel Calibration of Multi-Channel Integrated Receiver for Monopulse Radar)

  • 박진성
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권3호
    • /
    • pp.109-114
    • /
    • 2024
  • 모노펄스 레이다용 다채널 집적 수신기 내에 존재하는 채널 간 간섭은 최근 수신기의 소형화 추세에 따라 그 영향성이 늘어날 것으로 예상된다. 따라서, 본 논문에서는 모노펄스 레이다에 적용되는 다채널 집적 수신기의 수신 채널간 간섭을 보정하여, 표적 각도 검출 성능 왜곡을 배제할 수 있는 방법을 제안한다. 이를 위하여 스위치, 방향성 결합기, 정합 부하, ADC(Analog to Digital Converter), 채널 보정 신호원 등을 이용하여 보정 하드웨어 구성을 제안하였다. 또한, 스위치와 보정 신호원을 제어하여 총 9개의 산란 파라미터를 획득하고, 안테나로부터 출력되는 모노펄스 신호와 채널 간 간섭이 존재하는 상태에서의 다채널 수신기를 통과한 모노펄스 신호 간의 수학적 관계를 이용하여 왜곡되지 않는 모노펄스 신호를 복원하는 방법을 제안하였다.

고선량률 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교연구 (Comparison of Calibration Methods of $^{192}\textrm{Ir}$ Sources for High Dose Rate Brachytherapy)

  • 허현도;박성용;이레나;신동오;권수일;노준규;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.192-196
    • /
    • 2004
  • 본 연구는 국내에서 이용되고 있는 고선량률 근접치료기에 사용되는 Ir-192 선원에 대하여 Farmer type전리함과 우물형 전리함을 이용하여 선원의 세기를 측정하여 제조사에서 제공된 값과의 오차를 확인하고 두 증기간의 오차를 비교하였다. 동일한 Ir-192가 장착되어 가동 중인 6개의 병원의 고선량률 근접치료기(microSelctron, Nucletron, Netherlands)를 대상으로 선원의 모델별로 구분하여 상품화된 교정 Jig와 우물형 전리함 시스템을 이용, 선원의 세기를 측정하고 제조사에서 제공된 값과 비교하여 오차를 구하였다. 교정용 Jig를 이용한 선원 세기의 오차범위는 -2.40~+3.12%이고 우물형 전리함의 경우 오차범위는 -3.31~0.00%를 나타내었다. 측정 결과 두 장비 모두 제조사에서 제공된 값과 비교하였을 때 ${\pm}5%$의 오차를 넘지 않았으므로 임상 적용에는 문제가 없다. 외국의 사고 사례 보고에 따르면 계산 값에 의존하지 말고 새로운 선원이 교체될때 반드시 치료에 사용되기 전에 측정 도구를 이용하여 방사능의 세기를 측정하고 계산된 값과 비교하여 오차범위 내에서 일치하는지에 대한 확인 절차과정을 거치는 것이 필요하다.

  • PDF

AnnAGNPS 모형을 이용한 관목림지의 비점오염 모의 (Non-point Source Pollution Modeling Using AnnAGNPS Model for a Bushland Catchment)

  • 최경숙
    • 한국농공학회논문집
    • /
    • 제47권4호
    • /
    • pp.65-74
    • /
    • 2005
  • AnnAGNPS model was applied to a catchment mainly occupied with bushland for modeling non-point source pollution. Since the single event model cannot handle events longer than 24 hours duration, the event-based calibration was carried out using the continuous mode. As event flows affect sediment and nutrient generation and transport, the calibration of the model was performed in three steps: Hydrologic, Sediment and Nutrient calibrations. The results from hydrologic calibration for the catchment indicate a good prediction of the model with average ARE(Absolute Relative Error) of $24.6\%$ fur the runoff volume and $12\%$ for the peak flow. For the sediment calibration, the average ARE was $198.8\%$ indicating acceptable model performance for the sediment prediction. The predicted TN(Total Nitrogen) and TP(Total Phosphorus) were also found to be acceptable as the average ARE for TN and TP were $175.5\%\;and\;126.5\%$, respectively. The AnnAGNPS model was therefore approved to be appropriate to model non-point source pollution in bushland catchments. In general, the model was likely to result in underestimation for the larger events and overestimation fur the smaller events for the water quality predictions. It was also observed that the large errors in the hydrologic prediction also produced high errors in sediment and nutrient prediction. This was probably due to error propagation in which the error in the hydrologic prediction influenced the generation of error in the water quality prediction. Accurate hydrologic calibration should be hence obtained for a reliable water quality prediction.

Design of the IGRINS Calibration System

  • 오희영;김강민;이성호;장비호;이상은;박수종;육인수;천무영
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.155.2-155.2
    • /
    • 2011
  • We present development of the calibration system for IGRINS (the Immersion GRating Infrared Spectrograph). We mainly use Th-Ar and U hollow cathode lamp as the spectral calibration source and telluric features can be used additionally. For the flat source, we selected a 3000K tungsten halogen lamp with 2 inch integrating sphere. From Light Tools simulation, the result flat image through calibration optics satisfied <1% flatness error requirement. We also present mechanical design of calibration box that will be attached on the IGRINS dewar. Three moving stages are designed to perform switching mechanism between all of the observing modes - target observation, flat, precision RV measurement, and spectro-polarimetric observation.

  • PDF

K-SRI 에서의 방사성 중성자 선원교정 (Radioactive Neutron Source Calibration at the Korea Standards Research Institute)

  • 황선태;최길웅
    • Journal of Radiation Protection and Research
    • /
    • 제10권1호
    • /
    • pp.67-73
    • /
    • 1985
  • 임의 중성자 선원의 중성자 방출율 측정과 경합핵종에 의한 중성자 포획, 열중성자 누출 및 선원자체의 중성자 흡수에 적용되는 보정을 포함하여 한국표준연구소에서의 중성자 선원교정을 위한 $MnSO_4$ 용액 방법을 기술한다. 본 보고서에서는 에너지가MeV 영역에서 사용되는 중성자 방사선 기기의 교정검사를 위하여 상용화되어 있는 중성자 선원 (Am-Be, $^{252}Cf$)을 고려하였다.

  • PDF

Joint Estimation of Near-Field Source Parameters and Array Response

  • Cui, Han;Peng, Wenjuan
    • Journal of Information Processing Systems
    • /
    • 제13권1호
    • /
    • pp.83-94
    • /
    • 2017
  • Near-field source localization algorithms are very sensitive to sensor gain/phase response errors, and so it is important to calibrate the errors. We took into consideration the uniform linear array and are proposing a blind calibration algorithm that can estimate the directions-of-arrival and range parameters of incident signals and sensor gain/phase responses jointly, without the need for any reference source. They are estimated separately by using an iterative approach, but without the need for good initial guesses. The ambiguities in the estimations of 2-D electric angles and sensor gain/phase responses are also analyzed in this paper. We show that the ambiguities can be remedied by assuming that two sensor phase responses of the array have been previously calibrated. The behavior of the proposed method is illustrated through simulation experiments. The simulation results show that the convergent rate is fast and that the convergent precision is high.

기준음원의 교정 절차 개발 및 불확도 평가 사례 (Development of the calibration procedure of the reference sound source and case study on the uncertainty evaluation)

  • 서재갑;조완호
    • 한국음향학회지
    • /
    • 제43권3호
    • /
    • pp.344-350
    • /
    • 2024
  • 기준음원은 음향파워 측정에 활용되는 중요한 기준기로, 국제 표준으로 그 사양이 규정되어 있으며, 측정 표준 분야에서 주요 교정 품목으로 분류되고 있다. 이러한 기준음원은 공급 전압에 의하여 그 출력이 영향을 받기 때문에 각국에서 자체적으로 교정 서비스 체계를 확보할 필요가 있다. 본 연구에서는 잔향실 조건에서 기준음원을 교정하는 절차를 수립하고 불확도를 평가하였다. 교정 절차는 기본적으로 음향 파워의 정밀급 측정과정을 적용할 수 있으며, 여기서는 ISO 3741의 잔향실을 활용한 측정 방법을 검토하였다. 이를 위한 측정 시스템을 구성하고 실제 2종의 기준 음원에 대하여 측정을 수행하고 측정 불확도를 산출하였다. 측정 예를 통하여 잔향실 내 음압 분포의 불균일성과 체적 측정 불확도가 전체 불확도에 기여가 큰 것을 확인하였다. 추가적으로 입력 전압에 대한 영향을 실험적으로 검토하여 음향 파워 측정에서 반영할 수 있는 불확도 기여량을 검토하였다.

소음계 교정 자동화 시스템 개발 및 성능평가 (Development and Performance of Automated Calibration System of Sound Level Meters)

  • 김용태;조문재;이용봉;서재갑;서상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.704-709
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440 * 390 * 490 mm$^{3}$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC input. We use the Hybrid-Bisect, /Newton-Raphson method modified by the linearity as searching algorithm. Personal computer and program do the control, measurements, and calculations and finally do the accumulation of useful data and results. Several trials of automatic calibration using this developed system give reliable results.

  • PDF