• 제목/요약/키워드: Calibration Configuration

검색결과 89건 처리시간 0.026초

Multi-camera System Calibration with Built-in Relative Orientation Constraints (Part 2) Automation, Implementation, and Experimental Results

  • Lari, Zahra;Habib, Ayman;Mazaheri, Mehdi;Al-Durgham, Kaleel
    • 한국측량학회지
    • /
    • 제32권3호
    • /
    • pp.205-216
    • /
    • 2014
  • Multi-camera systems have been widely used as cost-effective tools for the collection of geospatial data for various applications. In order to fully achieve the potential accuracy of these systems for object space reconstruction, careful system calibration should be carried out prior to data collection. Since the structural integrity of the involved cameras' components and system mounting parameters cannot be guaranteed over time, multi-camera system should be frequently calibrated to confirm the stability of the estimated parameters. Therefore, automated techniques are needed to facilitate and speed up the system calibration procedure. The automation of the multi-camera system calibration approach, which was proposed in the first part of this paper, is contingent on the automated detection, localization, and identification of the object space signalized targets in the images. In this paper, the automation of the proposed camera calibration procedure through automatic target extraction and labelling approaches will be presented. The introduced automated system calibration procedure is then implemented for a newly-developed multi-camera system while considering the optimum configuration for the data collection. Experimental results from the implemented system calibration procedure are finally presented to verify the feasibility the proposed automated procedure. Qualitative and quantitative evaluation of the estimated system calibration parameters from two-calibration sessions is also presented to confirm the stability of the cameras' interior orientation and system mounting parameters.

A Calibration Technique for a Redundant IMU Containing Low-Grade Inertial Sensors

  • Cho, Seong-Yun;Park, Chan-Gook
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.418-426
    • /
    • 2005
  • A calibration technique for a redundant inertial measurement unit (IMU) containing low-grade inertial sensors is proposed. In order to calibrate a redundant IMU that can detect and isolate faulty sensors, the fundamental coordinate frames in the IMU are defined and the IMU error is modeled based on the frames. Equations to estimate the error coefficients of the redundant IMU are formulated, and a test sequence using a 2-axis turntable is also presented. Finally, a redundant IMU with cone configuration is implemented using low-grade inertial sensors, and the performance of the proposed technique is verified experimentally.

  • PDF

측정연산자에 의한 병렬기구 틸팅 테이블의 관측성에 관한 연구 (Study on the Observability of a Calibration System for a Parallel Tilting Table with Measuerment Operator)

  • 박근우;이민기;김태성
    • 대한기계학회논문집A
    • /
    • 제29권6호
    • /
    • pp.795-803
    • /
    • 2005
  • This paper studies the observability of calibration system with a measurement operator. The calibration system needs a simple digital indicator to measure the mobile table movements with respect to the MC coordinate. However, it yields the concern about the poor parameter observability due to measuring only a part of the movements. We uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of an observation matrix. The number of identifiable parameter is examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a 6-axis MC with parallel tilting table and the calibration results are presented. These results verify that all necessary kinematic parameters are observable and the calibration system has robustness to the noise using optimal calibration configurations.

레이저-비전 센서를 이용한 Autonomous Robot Kinematic Calibration (Autonomous Robot Kinematic Calibration using a Laser-Vision Sensor)

  • 정정우;강희준
    • 한국정밀공학회지
    • /
    • 제16권2호통권95호
    • /
    • pp.176-182
    • /
    • 1999
  • This paper presents a new autonomous kinematic calibration technique by using a laser-vision sensor called "Perceptron TriCam Contour". Because the sensor measures by capturing the image of a projected laser line on the surface of the object, we set up a long, straight line of a very fine string inside the robot workspace, and then allow the sensor mounted on a robot to measure the point intersection of the line of string and the projected laser line. The point data collected by changing robot configuration and sensor measuring are constrained to on a single straght line such that the closed-loop calibration method can be applied. The obtained calibration method is simple and accurate and also suitable for on-site calibration in an industrial environment. The method is implemented using Hyundai VORG-35 for its effectiveness.

  • PDF

Study on Optimal Calibration Configurations of a Parallel Type Machining Center Under a Single Planar Constraint

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.1886-1893
    • /
    • 2003
  • This paper examines the parameter observability of a calibration system that consrains a mobile platform to a planar table to take the calibration data. To improve the parameter observability, we find the optimal configurations providing the calibration with maximum contribution. The QR-decomposition is used to compute the optimal configurations that maximize the linear independence of rows of an observation matrix. The calibration system is applied to the parallel type manipulator constructed for a machining center. The calibration results show that all the necessary kinematic parameters assigned in a Stewart-Gough platform are identifiable and convergent to desirable accuracy.

구속연산자에 의한 보정 시스템의 관측성에 관한 연구 (Study on the Observability of Calibration System with a Constraint Oprerator)

  • 이민기;김태성;박근우
    • 대한기계학회논문집A
    • /
    • 제27권4호
    • /
    • pp.647-655
    • /
    • 2003
  • This paper studies the observability of calibration system with a constraint movement by a constraint operator. The calibration system with the constraint movement need only simple sensing device to check whether the constraint movements are completed within an established range. However, it yields the concern about the poor parameter observability due to the constraint movements. This paper uses the QR-decomposition to find the optimal calibration configurations maximizing the linear independence of rows of a observation matrix. The number of identifiable parameters are examined by the rank of the observation matrix, which represents the parameter observability. The method is applied to a parallel typed machining center and the calibration results are presented. These results verify that the calibration system with low-cost indicators and simple planar table is accurate as well as reliable.

한국원자력연구소 중성자교정실에 대한 중성자산란보정인자 결정연구 (Comparison Study of Experimental Neutron Room Scattering Corrections with Theoretical Corrections in RCL's Calibration Facility at KAERI)

  • 윤석철;장시영;김종수;김장렬;김봉환
    • Journal of Radiation Protection and Research
    • /
    • 제22권1호
    • /
    • pp.29-33
    • /
    • 1997
  • 중성자교정실내에서 $D_2O$ 감속 $^{252}Cf$중성자선원을 사용하여 계측기를 교정할 때는 그 계측기에 대한 교정실산란보정 인자를 미리 결정하여야 한다. 이러한 교정실산란보정인자는 계측기의 종류, 교정거리, 교정실형태에 따라 다르게 결정된다. 본 연구에서는 한국원자력연구소에서 운영하는 2차 표준중성자교정실에서 한가지의 열형광선량계와 2가지의 구형검출기에 대한 교정실산란보정인자를 실험적으로 결정하였고 본소의 2차 표준중성자교정실조건에 의하여 이론적으로 예측한 값과 비교하였다. 비교한 결과 실험하여 얻어진 상기의 3가지 계측기에 대한 교정실산란보정인자가 이론적으로 예측한 결과와 최대 약 10% 이내에서 일치하였다.

  • PDF

3차원 시각 센서를 탑재한로봇의 Hand/Eye 캘리브레이션 (Hand/Eye calibration of Robot arms with a 3D visual sensing system)

  • 김민영;노영준;조형석;김재훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.76-76
    • /
    • 2000
  • The calibration of the robot system with a visual sensor consists of robot, hand-to-eye, and sensor calibration. This paper describe a new technique for computing 3D position and orientation of a 3D sensor system relative to the end effect of a robot manipulator in an eye-on-hand robot configuration. When the 3D coordinates of the feature points at each robot movement and the relative robot motion between two robot movements are known, a homogeneous equation of the form AX : XB is derived. To solve for X uniquely, it is necessary to make two robot arm movements and form a system of two equation of the form: A$_1$X : XB$_1$ and A$_2$X = XB$_2$. A closed-form solution to this system of equations is developed and the constraints for solution existence are described in detail. Test results through a series of simulation show that this technique is simple, efficient, and accurate fur hand/eye calibration.

  • PDF

길이 측정 센서를 이용한 병렬기구의 기하학적 오차 보정 (Calibration of Geometric Errors of a Parallel Manipulator Using a Sensor of Length Measurement)

  • 최우천;임현규
    • 한국정밀공학회지
    • /
    • 제17권11호
    • /
    • pp.94-100
    • /
    • 2000
  • This paper proposes a method of geometric error calibration for a parallel using only sensor of length measurement without additional sensors. The concept is generalized which creates measurement residuals by exploring conflicting information provided with external length sensing. Although this calibration method requires many configurations, it has an advantage of using relatively simple length measurements. This method is shown to provide good calibration results, especially when there exist smaller measurement noises and more configurations are measured.

  • PDF