• Title/Summary/Keyword: Cage System

Search Result 264, Processing Time 0.047 seconds

Impact of Fish Farming on Macrobenthic Polychaete Communities (해상 가두리 양식이 저서 다모류군집에 미치는 영향)

  • Jung, Rae-Hong;Yoon, Sang-Pil;Kwon, Jung-No;Lee, Jae-Seong;Lee, Won-Chan;Koo, Jun-Ho;Kim, Youn-Jung;Oh, Hyun-Taik;Hong, Sok-Jin;Park, Sung-Eun
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.3
    • /
    • pp.159-169
    • /
    • 2007
  • Excessive input of organic matters from fish cage farms to the coastal waters has been considered as one of the major factors disturbing their benthic ecosystem. Sediment samples were taken from around the two fish cage zones (A and B) in Tongyeong coast in June and August 2003, to evaluate the ecological impacts of fish cage farming activity on the macrobenthic polychaete communities. Polychaete accounted for $81{\sim}87%$ of the total macrofauna individuals from each of the sampling stations. The number of species, abundance, diversity and dominant species of polychaete were rapidly changed with the distance from the fish cages. Within 10 m from the fish cages, Capitella capitata, which is a bio-indicator for the highly enriched sediments, was a dominant species and the lowest diversity was recorded. In particular, the maximum density (${\sim}18,410\;ind.m^2$) of C. capitata was found at Farm A where fish cages were more densely established within a semi-enclosed bay system. The sampling zone between 10 m and 15 m showed a rapid decrease of C. capitata with a rapid increase of the numbers of species, implying that this zone may be an ecotone point from a highly to a slightly enriched area. In the sampling zone between 15 m and 60 m, a transitional zone, which represents slightly enriched condition before normal one, was observed with additional increase and maintenance of the number of species and density of polychaete. In addition, the potential bio-indicators of organic enrichment, such as Lumbrineris longifolia and Aphelochaeta monilaris were the predominant species in the sampling zone. Multidimensional scaling (MDS) ordination plots and k-dominance curves confirmed the above results on the gradual changes in the macrobenthic polychaete communities. Our findings suggest that the magnitude of impact of fish cage farming activity on polychaete communities is probably governed by a distance from fish cage, density of fish cage and geomorphological characteristics around fish cage farm.

PCB Instrumentation with Lubboe Bone in Anterior Cervical Interbody Fusion (PCB 기구와 이종골을 이용한 경추체간 전방 유합술)

  • Park, Jeong Hyun;Oh, Seong Hoon;Yi, Hyeong Joong;Kim, Ju Heon;Kim, Young Soo;Ko, Yong;Kim, Kwang Myung;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1284-1290
    • /
    • 2001
  • Objective : PCB cervical instrument is a newly introduced fusion device which comprises cervical plate, cage (spacer) and screw system. It is developed to enhance fusion rate and stability, as well as to reduce complications related to hardware failure. We investigated the efficacy of clinical and radiological results of PCB instrument and Lubboc bone. Methods : From August, 1998 to October, 1999, authors performed 54 cases of anterior cervical interbody fusion with PCB instrument and Lubboc bone. Retrospective analysis was undertaken based on clinical and radiological findings. Clinical improvement was evaluated according to Odom's criteria. Cervical plain films and tomography were taken every 2 months to evaluate the degree of interbody fusion and disc height changes. Results : Bone fusion was observed in 36 cases(90%) over 6 months after operation, and during which time there was no significant interval change. There were 3 cases of hardware dislodgement. Disc height was increased significantly and preserved in all cases. Clinical outcome over good degree was seen more than 94% of patients. Conclusion : Longer follow-up period and comparative studies to similar instrument appear to be necessary, but this instrumentation system has shown high fusion rate and fewer adverse effects in our series. We believe this system might be indicated for the treatment of cervical trauma and degenerative disease in selective cases.

  • PDF

Selection of Motor Starting Method by Numeric Simulation (기동시뮬레이션 방법에 의한 유도전동기 기동방식 선정)

  • Chang, Chung-Koo;Suh, Sang-Jin;Lee, Min-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.817-820
    • /
    • 2002
  • Since a squirrel cage induction motor by NEMA Design types is designed to withstand full-voltage starting, direct starting method can be the most economical one. Starting a squirrel cage motor from standstill by connecting it directly across the line may allow inush currents of approximately 500-600% of rated current at lagging power factor of 35-50%. For many of the large motors, the starting inrush current may be great enough to cause voltage dips, which may adversely affect the building's lighting system. Electric utilities also have restrictions on starting currents, so that voltage fluctuations can be held to prescribed limits. Therefore the need for choosing the most appropriate method of motor starting is quite essential. In this paper, we proposed a plan for the selection of the most appropriate motor starting method, first by way of numeric simulation using manufacturer's data and second by way of actual experience. So far, more often than not, the selection of motor starting method has been accomplished only as regards to the capacity of the motor and the frequency of starting and stopping. But nowadays such high-tech apparatus as soft starters are being developed, and we are on the position to give more attention to clarify the way of selection of the motor starting method.

  • PDF

Evaluation of Occupant Protection of Van and Light Truck Vehicle (승합 및 경트럭의 탑승자 보호성능 평가)

  • Kim, Guan-Hee;Park, In-Song
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.13-19
    • /
    • 2012
  • The fatalities rate for passenger vehicles, vans, and commercial vehicles is 1.23, 1.90 and 2.46 deaths per 10,000 registered vehicles, respectively. This shows that vans and commercial vehicles are vulnerable compare to passenger vehicles. To evaluate the crashworthiness of van and Light Truck Vehicle(LTV), we carried out frontal offset crash test at 64km/h, 40% overlap as per IIHS(Insurance Institute for Highway Safety). The test result show that LTV is very poor to protect occupant at frontal crash cause there is no safety system such as airbag and pretensioner and front end length(distance from front bumper to steering wheel) is short. One of the van rated as the lowest rating even it is equipped with airbag, cause its safety cage was collapsed during the test. This result shows that the structural integrity is very important in terms of occupant protection.

A Study on the Control Method of Hand & Automatic Operation of On-Off Wiring of an Easy Elevator (간이 엘리베이터 수.자동 개폐배선 제어방식에 관한연구)

  • Wee, Sung-Dong;Gu, Hal-Bon;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1107-1112
    • /
    • 2002
  • An easy elevator originated is an opened system to compare an existing equipment, and learning efficient is high as a wiring that the sequence control circuit is on and off. The structure of an equipment to be controled from the first floor to the fifth floor is constructed by a lamp to express the function of the open-close of the door according to the cage moving, to express the mechanical actuation of the forward-reverse break and motor of load and of hand-worked control component of Push-Button S/W, L/S and Relay. In order to act of the elevator function that these components connected, designed the auto program and the sequence control circuit. Consequently the process that these(1~5steps) operated the cage with an auto program of the elevator and the sequence control circuit is controled by the step of forward and reverse that the L/S1~L/S5 of sensor adjust function let posit, by the adjustable S/W1~S/W5 of PLC testing panel and the S/W1~S/W5 which installed on the transparent acryl plate of a frame. In here, improved apparatus is the learning equipment of combined use to study the principle and the technique of the originated sequence control circuit and the auto program of PLC.

  • PDF

Shape Design of Induction Motors for Efficiency Improvement (유도기 효율향상을 위한 회전자슬롯 형상최적화)

  • Kwak, In-Gu;Lee, Hyang-Beom;Park, Il-Han;Hahn, Song-Yop
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.929-931
    • /
    • 1993
  • The design sensitivity analysis based on the finite element method is presented for the eddy current problem with a voltage source. Since, in this problem, the complex variable is used as the state variable, new approach to the sensitivity calculation for the complex variable system is required. Its result is applied to the design of the rotor slot shape of squirrel cage induction motor. As a analysis model, only one slot pitch of rotor is analyzed by using a Periodic boundary condition. The use of this minimal modelling method leads to much saving of calculation time. The design objective is to obtain the desired slip-torque characteristic. Because the shape of rotor slot has much influence on the slip torque characteristic, the design variables are taken on the interface shape between rotor core and rotor bar. The initial shape of rotor slot is the trapezoidal type with rounding corners. The obtained final shape is quite similar to the double squirrel cage type.

  • PDF

Analysis of IGBT Inverter controlled Squirrel Cage Induction Motor during Eccentricity Rotor Motion (IGBT 인버터구동 유도전동기의 회전자 편심 특성 해석)

  • Kim, Mi-Jung;Kim, Byong-Kuk;Moon, Ji-Woo;Cho, Yun-Hyun;Hwang, Don-Ha;Kang, Dong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1055-1056
    • /
    • 2007
  • Asymmetric electro-magnetic force caused by the frictional worn bearing, rotor misalignment and unbalanced rotor etc. generates an asymmetrical operation, vibration and electro-magnetic noise. The need for detection of these rotor eccentricities has pushed the development of monitoring methods with increasing sensitivity and noise immunity. This paper is proposed the analysis method of the squirrel-cage induction motor driven by IGBT inverter using finite element method (FEM) and subroutine. The effect of the unbalanced magnetic pull in the inverter-fed induction motor which is in asymmetrical whirling motion is presented. The analysis results of rotor eccentricity could compare with motors which have been made normal air-gap motor and irregular air-gap motor and verify reliability. The simulation and experiment results can be useful for on-line faults detection monitoring system of induction motors.

  • PDF

Anxiolytic Action of Taurine via Intranasal Administration in Mice

  • Jung, Jung Hwa;Kim, Sung-Jin
    • Biomolecules & Therapeutics
    • /
    • v.27 no.5
    • /
    • pp.450-456
    • /
    • 2019
  • Taurine has a number of beneficial pharmacological actions in the brain such as anxiolytic and neuroprotective actions. We explored to test whether taurine could be transported to the central nervous system through the intranasal route. Following intranasal administration of taurine in mice, elevated plus maze test, activity cage test and rota rod test were carried out to verify taurine's effect on anxiety. For the characterization of potential mechanism of taurine's anti-anxiety action, mouse convulsion tests with strychnine, picrotoxin, yohimbine, and isoniazid were employed. A significant increase in the time spent in the open arms was observed when taurine was administered through the nasal route in the elevated plus maze test. In addition, vertical and horizontal activities of mice treated with taurine via intranasal route were considerably diminished. These results support the hypothesis that taurine can be transported to the brain through intranasal route, thereby inducing anti-anxiety activity. Taurine's anti-anxiety action may be mediated by the strychnine-sensitive glycine receptor as evidenced by the inhibition of strychnine-induced convulsion.

Egg Quality in Battery Cage and Free-Range Systems : with Reference to Comparison of Eggs Based on Price and Hens' Age (방사 사육과 배터리 사육 산란계에서 난질 : 난가와 산란계 주령에 따른 난질의 비교)

  • Kim, Dae-Woo;Kang, Seok-Min;Yang, Young-Rok;Kim, Ji-Min;Yoon, Hyung-Sook;Jeon, Jung-Hwan;Choi, Yang-Ho
    • Korean Journal of Organic Agriculture
    • /
    • v.24 no.1
    • /
    • pp.115-122
    • /
    • 2016
  • The main purpose of the current study was to compare quality of eggs 1) produced from hens housed in battery cages vs. free range, 2) from young vs. old hens, and 3) tagged with the lowest vs. the highest price in a local franchised mart. The ages of hens, at which their eggs were used for the analysis of quality, were 70 weeks old in the experiment 1, 22 and 47 weeks old in the experiment 2, and were unknown in the experiment 3. Eggs were analyzed for weight, albumen height, Haugh unit, shell color, shell strength, shell thickness, shell weight, yolk color, yolk weight, and egg white weight. In the experiment 1, significant differences were detected between two housing systems in shell color, shell weight, yolk color, and yolk weight (P<0.05), but not in egg weight, albumen height, Haugh unit, shell strength, shell thickness, and egg white weight (P>0.05). Although egg weight was slightly but not significantly higher in battery cages by 2.2 g than in free range, yolk weight was significantly higher in battery cage (P<0.05). On the contrary, shell color was greatly increased in free range system by 68.5% compared with battery cage. In the experiment 2, there were significant differences between young and old hens in egg weight, albumen height, Haugh unit, shell strength, shell weight, yolk color and yolk weight (P<0.05). Egg weight, shell weight, yolk color and yolk weight were increased in old hens than young hens while albumen height, Haugh unit, and shell strength were decreased. In the experiment 3, egg weight, albumen height, Haugh unit, shell weight, and egg white weight were significantly higher in the highest priced eggs than the lowest ones (P<0.05), whereas shell strength and yolk color were lower (P<0.05) but shell color, shell thickness and yolk weight were not different (P>0.05). So, egg freshness was clearly higher in the highest priced ones than in the lowest (P<0.05). Due to the limited information on raising and husbandry of laying hens whose eggs were tested for egg quality in the current study, the present results should be cautiously interpreted while contributing to the future study as a basis in this field.

Development of continuous indoor rearing technique of mole cricket, Gryllotalpa orientalis Burmeister (Orthoptera: Gryllotalpidae) (땅강아지(Gryllotalpa orientalis Burmeister)의 실내 누대사육 기술개발)

  • Park, Young-Kyu;Lee, Young-Bo
    • Journal of Sericultural and Entomological Science
    • /
    • v.52 no.2
    • /
    • pp.96-101
    • /
    • 2014
  • The present study was conducted for two years to develop the indoor breeding system of mole cricket, Gryllotalpa orientalis Burmeister. In 2013, the total mean number of progenies was $430.{\pm}20.0$ ($mean{\pm}SE$); $15.3{\pm}25.8$ of 2nd-3rd instars, $28.8{\pm}24.0$ 3rd-5th and $2.4{\pm}2.7$ 6th-8th. In 2014, the rearing yielded similar result to that of 2013; $43.5{\pm}31.0$ in total with $25.8{\pm}25.6$ of 2nd-3rd instars, $23.6{\pm}21.3$ 3rd-5th and $2.9{\pm}2.3$ 6th-8th. The successful breeding rate using indoor cages was 46.9% in 2013 and 50.0% in 2014. In total 147 individuals were successfully reared in an outdoor rearing cage with 25 females released and 78 individuals in an indoor rearing cage with 100 females and 50 males released. 86.4% and 89.7% of the nymphs reared were collected within 25cm depth of the soil in the outdoor and indoor cage, respectively.