• Title/Summary/Keyword: Cable Diagnosis

Search Result 153, Processing Time 0.031 seconds

Elimination of Screen-Flickering Phenomenon in Multi-Function Display During Flight of Fixed-Wing Aircraft

  • Kwon, Jung-Hyuk;Kwon, Ik-Hyun;Beak, Jun-Ho;Jang, Geun-Hyung;Lee, Wang-Sang
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.2
    • /
    • pp.45-51
    • /
    • 2021
  • In this study, we aim to eliminate the flickering phenomenon in multi-function display (MFD) units during the flight of fixed-wing aircraft. To execute flight missions effectively, the video signals transmitted to MFDs must provide information accurately and seamlessly. Therefore, a method for addressing the flickering phenomenon-including cause analysis and failure diagnosis-is adopted; specifically, a wiring configuration with a direct connection between the video signal cables and with a short cable length is adopted. The proposed method is experimentally verified using a flight test.

Intelligent Diagnosis System Based on Fuzzy Classifier (퍼지 분류기 기반 지능형 차단 시스템)

  • Sung, Hwa-Chang;Park, Jin-Bae;So, Jea-Yun;Joo, Young-Hoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.4
    • /
    • pp.534-539
    • /
    • 2007
  • In this paper, we present the development of an intelligent diagnosis system for detecting faults of the low voltage wires. The wire detecting system based on the Time-Frequency Domain Reflectometry (TFDR) algorithm shows the condition of the wires. We analyze the reflected signal which is sent from the wire detecting system and classify the fault type of the wires by using the intelligent diagnosis system. Through the TFDR, generally, the conditions of the wires are classified into the three types - damage, open and short. In order to classify the fault type efficiently, we use the fuzzy classifier which is represented as IF-THEN rules. Finally, we show the utility of the proposed algorithm by performing the simulation which is based on the data of the coaxial cable.

Present Status and Accuracy Improvement Plan on Partial Discharge Diagnosis Technology for Underground Transmission Cable (지중 송전케이블 PD진단 기술 현황 및 정확도 향상방안 검토)

  • Jang, Tae-In;Kang, Yeon-Woog;Kang, Ji-Won;Kim, Jong-Chae
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.537-538
    • /
    • 2011
  • 본 논문은 지중송전 XLPE 케이블에 대한 국내외 부분방전(Partial Discharge) 진단기술 현황과 정확도 향상방안을 다룬다. 먼저, 최근의 국내 XLPE 케이블 설치 및 고장 현황을 살펴보고, 국내외 PD진단 동향, PD 진단장비의 특징, 접속부 계면 PD의 주파수 특성을 차례로 알아본다. 마지막으로 이를 종합하여 진단 정확도 향상 방안 및 케이블 고장예방을 위한 향후 연구방향을 제시한다.

  • PDF

Detecting Method of Internal Degradation for Cable using Finite Element Method (와전류 센서를 이용한 케이블용 내부 열화 검출 방법)

  • Park, Geon-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.01a
    • /
    • pp.291-292
    • /
    • 2015
  • 와전류 탐상 기법을 이용하여 배전선로의 내부 열화를 검출하는 시스템을 개발할 수 있는데, 본 연구에서는 이를 위하여 유한요소법을 통한 시뮬레이션으로 와전류 센서의 기초 모델링을 구상한 후 실제 와전류 센서를 제작하여 가속 열화에 의한 센서 특성을 조사하였다.

  • PDF

Application of Object-oriented Language to Power Systems (객체지향기법의 전력계통시스템에의 적용)

  • Park, J.H.;Kim, J.N.;Shin, J.H.;Lee, J.Y.;Baek, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1218-1220
    • /
    • 1999
  • In this paper, we developed object-oriented analysis method for electric power system. It was applied to fault diagnosis, power system stability analysis and service restoration system in emergency state. Objectoriented programming(OOP)is a more flexible method than procedural programming. We proposed flexible modeling method for power system analysis.

  • PDF

Development of a DNC system for NC machine tools (NC 공작기계용 DNC system 개발)

  • 신동수;정성종
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.887-891
    • /
    • 1992
  • In this study, it is developed the interactive DNC(Direct Numerical Control) system, in using RS-232C cable and auxiliary computer, through the diagnosis of planning process and information evaluation. this DNC system recognize the Manufacturing planning and control it. This DNC system has a different notation. It can be done by an operator who hasn't knowledge about personnel computer. It is operated with automatic planning and measurement tec. by operator, using part program on the NC(Numerical Control).

  • PDF

Development of Wireless Sensor Node and Field Application of Long-span Bridge using Ubiquitous Technology (유비쿼터스 기술을 이용한 무선센서노드 개발 및 장대교량 현장적용 검증 실험)

  • Jo, Byung-Wan;Park, Jung-Hoon;Shin, Byung-Chul;Kim, Heoun;Yoon, Kwang-Won;Yang, Yo-Sub
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2008.04a
    • /
    • pp.127-132
    • /
    • 2008
  • As economic rapid growth, large structures are damaged by defects from design and construction process of the formation and environments. Therefore, safety diagnosis and monitoring skills are bringing importance into relief and legislate for safety diagnosis of large structures. However, the existing monitoring systems are difficult by using wire cable because of cost, error of date, location, revise. In this paper, wireless sensor network which are accelerator, temperature sensor system using ubiquitous had been field test on Sea-Hea Grand bridge. We compare accelerator, temperature sensor system with wire and wireless sensor network.

  • PDF

Power Tunnel Monitoring and Diagnosis Based On Multiple Attribute Making Decision with Uncertainty (불확실성을 고려한 다중요소 의사 결정기반의 지중전력구 감시 및 진단)

  • Lee, Gi-Hea;Kim, Sang-Tae;Lee, Ji-Hoon;Kim, Jong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.349-350
    • /
    • 2015
  • Traditional power tunnel monitoring and diagnosis system provides simple alert in accordance with limits which set by operator using various field installed various sensor measurements. System's algorithm is too simple and it has uncertainty of sensor with error. In this paper, proposed algorithm give operator verification using installed sensor measurements such as environmental sensors for fire prevention because of cable overheat in the power tunnel.

  • PDF

Aging Diagnosis of Underground Distribution Power Cables Using Breakdown Lifetime Prediction (파괴수명예측을 통한 지중배전용 전력케이블의 열화 진단)

  • Kim, Chung-Bae;Lee, Jung-Bin;Lim, Chang-Sub;Jang, Young-Hak;Lee, Jin;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.222-225
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method. which was to be analyzed non-electrical experiments and synthesized by degradation points. To supplement this method, it was also carried out using several electrical analyses. Breakdown voltages were measured and breakdown lifetimes were Predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorted up to 1/3 times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

The diagnosis and analysis for the correct design of electrical system in water treatment plan(Dissolved Air FIotation Process) (고도정수처리(DAF) 정수장 전력설비 적정 설계를 위한 고조파 현장 측정 및 분석)

  • Kim, Dong-Ryong;Kim, Gi-Tae;Han, Byong-Ok;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.61-63
    • /
    • 2007
  • In these days there are many troubles - system data error, control malfunctions, cable overheating - in water treatment plant. Specially DAF(Dissolved Air Floation Process) plant has high frequency than previous water treatment process. DAF plant has diverse equipment, nonlinear loads for the precise control. But there is no sufficient overall study about harmonics condition of water treatment plant just taking a following partial action without a fundamental solution. On designing of power system, designer should have regard to harmonics condition, but there is no guide reflected harmonics condition on DAF plant This study says what is the result of guideless design about harmonics. With the result of diagnosis and analysis in DAF plant, economical efficiency and safety of plant will be upgraded in the next design.

  • PDF