• 제목/요약/키워드: CTA

검색결과 222건 처리시간 0.032초

Use of a semitendinosus myocutaneous flap for the coverage of hindlimb full-thickness skin defects in cats

  • Eleftheria Dermisiadou;Ioannis Panopoulos;Dimitra Psalla;Stefanos Georgiou;Aikaterini Sideri;Apostolos Galatos;Vassiliki Tsioli
    • Journal of Veterinary Science
    • /
    • 제24권1호
    • /
    • pp.14.1-14.15
    • /
    • 2023
  • Background: The management of feline hindlimb full-thickness skin defects is challenging. On the other hand, the use of a semitendinosus (ST) myocutaneous flap for their coverage has not been reported. Objectives: To describe the ST flap and compare it with second intention healing for managing hindlimb full-thickness skin defects. Methods: In 12 purpose-bred laboratory domestic short-haired cats, two wounds were made on each tibia. The wounds in group A (n = 12) were covered with ST flaps, and those in group B (n = 12) were left to heal by second intention. In both groups, clinical assessment scoring and planimetry were performed between one-30 d postoperatively. Computed tomography-angiography (CTA) was performed on days zero, 10, and 30, and histological examinations were performed on days zero and 14 and at 6 and 12 mon postoperatively. Results: Statistically significant differences in the clinical assessment scores were observed between groups A and B on days 14 (p = 0.046) and 21 (p = 0.016). On the other hand, the time for complete healing was similar in the two groups. CTA revealed significant differences in the muscle width (day 0 compared to days 10 and 30 [p = 0.001, p = 0.026, respectively], and days 10 to 30 [p = 0.022]), ST muscle density, and the caliber of the distal caudal femoral artery and vein (day 0 compared to day 10 [p < 0.001], and days 10 to 30 [p < 0.001]). Histologically significant differences in inflammation, degeneration, edema, neovascularization, and fibrosis were observed on day 14 compared to zero and 6 mon, but no differences were found between the time interval of 6 and 12 mon. Conclusions: An ST flap can be used effectively to manage hindlimb full-thickness skin defects.

Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs

  • Soyon An;Gunha Hwang;Rakhoon Kim;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Science
    • /
    • 제24권5호
    • /
    • pp.65.1-65.9
    • /
    • 2023
  • Background: Bone subtraction computed tomography angiography (BSCTA) is a useful alternative technique for improving visualization of vessels surrounded by skull bone. However, no studies have compared computed tomography angiography (CTA) and BSCTA for improving the visibility of canine cerebral blood vessels. Objectives: To evaluate the potential benefit of BSCTA for better delineation of brain arteries of the circle of Willis (CoW) in dogs by comparing BSCTA with non-subtraction computed tomography angiography (NSCTA). Methods: Brain CTA was performed for nine healthy beagle dogs using a bolus tracking method with saline flushing. A total dose of 600 mgI/kg of contrast agent with an iodine content of 370 mgI/mL was injected at a rate of 4 ml/s. Bone removal was achieved automatically by subtracting non-enhanced computed tomography (CT) data from contrast CT data. Five main intracranial arteries of the CoW were analyzed and graded on a scale of five for qualitative evaluation. Results: Scores of basilar artery, middle cerebral artery, and rostral cerebral artery in the BSCTA group were significantly higher than those in the NSCTA group (p = 0.001, p = 0.020, and p < 0.0001, respectively). Scores of rostral cerebellar artery (RcA) and caudal cerebral artery (CCA) did not differ significantly between the two groups. However, scores of RcA and CCA in the BSCTA group were higher than those in the NSCTA group. Conclusions: BSCTA improved visualization of intracranial arteries of the CoW with close contact to bone. Thus, it should be recommended as a routine scan method in dogs suspected of having brain vessel disease.

Utility of Noncontrast Magnetic Resonance Angiography for Aneurysm Follow-Up and Detection of Endoleaks after Endovascular Aortic Repair

  • Hiroshi Kawada;Satoshi Goshima;Kota Sakurai;Yoshifumi Noda;Kimihiro Kajita;Yukichi Tanahashi;Nobuyuki Kawai;Narihiro Ishida;Katsuya Shimabukuro;Kiyoshi Doi;Masayuki Matsuo
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.513-524
    • /
    • 2021
  • Objective: To assess the noncontrast two-dimensional single-shot balanced turbo-field-echo magnetic resonance angiography (b-TFE MRA) features of the abdominal aortic aneurysm (AAA) status following endovascular aneurysm repair (EVAR) and evaluate to detect endoleaks (ELs). Materials and Methods: We examined four aortic stent-grafts in a phantom study to assess the degree of metallic artifacts. We enrolled 46 EVAR-treated patients with AAA and/or common iliac artery aneurysm who underwent both computed tomography angiography (CTA) and b-TFE MRA after EVAR. Vascular measurements on CTA and b-TFE MRA were compared, and signal intensity ratios (SIRs) of the aneurysmal sac were correlated with the size changes in the AAA after EVAR (AAA prognoses). Furthermore, we examined six feasible b-TFE MRA features for the assessment of ELs. Results: There were robust intermodality (r = 0.92-0.99) correlations and interobserver (intraclass correlation coefficient = 0.97-0.99) agreement. No significant differences were noted between SIRs and aneurysm prognoses. Moreover, "mottled high-intensity" and "creeping high-intensity with the low-band rim" were recognized as significant imaging findings suspicious for the presence of ELs (p < 0.001), whereas "no signal black spot" and "layered high-intensity area" were determined as significant for the absence of ELs (p < 0.03). Based on the two positive features, sensitivity, specificity, and accuracy for the detection of ELs were 77.3%, 91.7%, and 84.8%, respectively. Furthermore, the k values (0.40-0.88) displayed moderate-to-almost perfect agreement. Conclusion: Noncontrast MRA could be a promising imaging modality for ascertaining patient follow-up after EVAR.

Evaluation of Zone 2 Thoracic Endovascular Aortic Repair Performed with and without Prophylactic Embolization of the Left Subclavian Artery in Patients with Traumatic Aortic Injury

  • Miju Bae;Chang Ho Jeon;Hoon Kwon;Jin Hyeok Kim;Seon Uoo Choi;Seunghwan Song
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.577-583
    • /
    • 2021
  • Objective: To report the authors' experience in performing thoracic endovascular aortic repair (TEVAR) for zone 2 lesions after traumatic aortic injury (TAI). Materials and Methods: This retrospective review included 10 patients who underwent zone 2 TEVAR after identification of aortic isthmus injury by CT angiography (CTA) upon arrival at the emergency room of a regional trauma center from 2016 to 2019. Patients were classified into two groups: those who underwent left subclavian artery (LSA) embolization concurrently with the main TEVAR procedure, and those in whom LSA embolization was not performed during the main procedure, but was planned as a bailout treatment if type II endoleak was noted on follow-up CTA images. Pre-procedural and procedure-related factors and post-procedure prognosis were compared between the groups. Results: There were no differences in pre-procedural factors, occurrence of endoleaks, and post-procedure prognosis (including mortality) between patients in the two groups. The duration of the procedure was shorter in the non-LSA embolization group (61 minutes vs. 27 minutes, p = 0.012). During follow-up, type II endoleak did not occur in either group. Conclusion: Delaying preventative LSA embolization until stabilization of the patient would be desirable when performing zone 2 TEVAR for TAI, in the absence of endoleak on the completion aortography image taken after complete deployment of the stent graft.

Preoperative CT Navigation of Perigastric Vessel Anatomy for Gastrectomy

  • Baek, Song-Ee;Hyung, Woo Jin;Lim, Joon Seok
    • Journal of International Society for Simulation Surgery
    • /
    • 제1권1호
    • /
    • pp.41-44
    • /
    • 2014
  • The aim of this report is showing the case that we could give exact navigation of perigastric vessels for gastrectomy with 3D CTA. A 74-year-old male patient visited hospital with gastric cancer. Early gastric cancer, type IIb was found at stomach antrum great curvature side. Before surgery, he underwent 3D CT angiography. 3D volume rendering images and MIP images were made by post processing. He had replaced Lt. hepatic artery arising from Lt. gastric artery. Surgeon could get patient's specific vascular anatomy before surgery including surgically relevant anatomical distance and direction and could finish gastrectomy within 4 hours and just 53ml blood loss.

HR-WPAN에서의 Weighted Fairness를 이용한 Channel Time스케줄링 기법 연구 (Channel time scheduling scheme using Weighted Fairness for HR-WPAN)

  • 이용석;한진우;최웅철;이승형;정광수
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2004년도 가을 학술발표논문집 Vol.31 No.2 (3)
    • /
    • pp.67-69
    • /
    • 2004
  • HR-WPAN(802.15.3)의 CTAP에는 Time Slot(CTA) 할당 스케줄링 기법이 적용되어 있지 않다. 이에 본 논문에서는 CTAP의 채널 할당 방식에 유선망의 패킷 스케줄링방법인 WFQ(Weighted Fair Queuing)를 적용하고자 한다. 현재 표준에서 TDMA를 적용하기 위한 명확한 스케줄링 기법이 없으며, 대량의 트래픽으로 인해 소량의 트래픽이 기아현상을 겪을 수 있는 공정성(Fairness)의 문제가 있다. 따라서 본 논문에서는 각각의 DEV들에 가중치를 적용하여 공정한 방법으로 채널을 할당 받고자 한다. 이를 통해 HR-WPAN의 채널 할당방식에 있어서의 공정성 문제를 해결하고 delay bound를 제공하는 time slot 스케줄링 기법을 제안한다. 본 논문에서는 Weighted Fairness를 적용한 분산적 스케줄링 방법에 대한 연구를 통해 HR-WPAN에서의 성능 향상을 이루고자 한다.

  • PDF

Characterization of polymer inclusion membrane containing Aliquat 336 as a carrier

  • Manzak, Aynur;Yildiz, Yasemin;Tutkun, Osman
    • Membrane and Water Treatment
    • /
    • 제6권2호
    • /
    • pp.95-102
    • /
    • 2015
  • The presented research is about characterization of Cellulose Triacetate (CTA) based Polymer Inclusion Membranes (PIMs) which incorporated the commercial extractant Aliquat 336, Tributylphosphate (TBP) as modifier and 2-Nitro Phenyl Pentyl Ether (NPPE) as plasticizer, for the preparation of the membranes. Chemical and physical characteristics of the synthesized membranes especially membrane thickness and side difference effects were investigated. Different surface structures and membrane thickness affect the extraction efficiency of membranes. Membrane extraction experiments were studied where the glass-facing surface of the membranes placed next to feed phase and the air-facing surface to stripping phase. The membrane was characterized by means of AFM, FT-IR and SEM.

Thermal Stimulated Conductivity in Cellulose Triacetate-Multiwalled Carbon Nanotube Polymer Films

  • Basavaraja, C.;Jo, Eun-Ae;Kim, Bong-Sung;Huh, Do-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권8호
    • /
    • pp.2207-2210
    • /
    • 2010
  • This paper describes the preparation and study of thermally stimulated discharge conductivity (TSDC) study of cellulose triacetate (CTA) - multiwalled carbon nanotubes (MWNTs) film thermoelectrets. TSDC has been carried out in the temperature range 308 - 503 K and at four different polarizing fields. The conductivity of the polymer blends increased with increase in temperature showing a semi-conducting behavior. The apparent activation energy also showed a pronounced effect with the increase in the content of MWNTs.

Characterizations of Interface-state Density between Top Silicon and Buried Oxide on Nano-SOI Substrate by using Pseudo-MOSFETs

  • Cho, Won-Ju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권2호
    • /
    • pp.83-88
    • /
    • 2005
  • The interface-states between the top silicon layer and buried oxide layer of nano-SOI substrate were developed. Also, the effects of thermal treatment processes on the interface-state distributions were investigated for the first time by using pseudo-MOSFETs. We found that the interface-state distributions were strongly influenced by the thermal treatment processes. The interface-states were generated by the rapid thermal annealing (RTA) process. Increasing the RTA temperature over $800^{\circ}C$, the interface-state density considerably increased. Especially, a peak of interface-states distribution that contributes a hump phenomenon of subthreshold curve in the inversion mode operation of pseudo-MOSFETs was observed at the conduction band side of the energy gap, hut it was not observed in the accumulation mode operation. On the other hand, the increased interface-state density by the RTA process was effectively reduced by the relatively low temperature annealing process in a conventional thermal annealing (CTA) process.

동축 이중제한분류의 상사성에 대한 실험적 연구 (An Experimental Study on the Similarity of Confined Coaxial Jets)

  • 사용철;이태환;이준식
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1291-1299
    • /
    • 1995
  • In confined coaxial jets, the flow-mixing characteristics depend on the initial conditions at the nozzle outlet such as velocity ratio and nozzle radius ratio. In this study, nozzle ratio(inner/outer) was 0.3. Longitudinal axial velocity, turbulent intensity and Reynolds shear stress were measured by CTA. Measurements were made from the duct inlet to the region where similarity solution could exist. This study investigated flow charicteristics according to the variation of similitude parameter which was derived from the theory of Craya-Cutet. The range of similarity region depends on the variation of the similitude patameter. The form factor obtained from the axial velocity profile in the similarity region was constant. The higher the similitude parameter, the wider the spread rate of the jets. Due to this fact, the similarity conditions developed more quickly and the region where the similarity holds became narrow. Present experimental data confirmed the validity of Craya-Curtet theory.