• Title/Summary/Keyword: CT Scans

Search Result 576, Processing Time 0.024 seconds

Omental Torsion and Infarction Secondary to Omental Hernia in the Right Inguinal Canal (오른쪽 서혜부 탈장에 의해 이차적으로 발생한 대망의 염전 및 경색)

  • Yu Hyun Lee;Jae Hoon Lim;Heon-Kyun Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.1003-1007
    • /
    • 2020
  • Omental torsion secondary to inguinal hernia has rarely been reported as a cause of acute abdominal pain. However, in our case, omental infarction due to prolonged inguinal hernia-associated omental torsion led to the formation of a large omental mass with marginal fibrosis, and the patient presented with chronic abdominal pain. A 74-year-old man presented with complaints of lower abdominal pain for 1 month; subsequently, bilateral inguinal hernias were identified through inguinal ultrasonography. CT scans revealed that the greater omentum was trapped within the right inguinal canal, leading to omental torsion. The greater omentum, distal to the pedicle, appeared as a 30 cm-sized oblong fibrofatty mass in the right lower abdomen and pelvic cavity. Laparoscopic omentectomy with hernia repair was successfully performed.

Distribution of the intraosseous branch of the posterior superior alveolar artery relative to the posterior maxillary teeth

  • Carsen R. McDaniel;Thomas M. Johnson;Brian W. Stancoven;Adam R. Lincicum
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.121-127
    • /
    • 2024
  • Purpose: Preoperative identification of the intraosseous posterior superior alveolar artery (PSAA) is critical when planning sinus surgery. This study was conducted to determine the distance between the cementoenamel junction and the PSAA, as well as to identify factors influencing the detection of the PSAA on cone-beam computed tomography (CBCT). Materials and Methods: In total, 254 CBCT scans of maxillary sinuses, acquired with 2 different scanners, were examined to identify the PSAA. The distance from the cementoenamel junction (CEJ) to the PSAA was recorded at each maxillary posterior tooth position. Binomial logistic regression and multiple linear regression were employed to evaluate the effects of scanner type, CBCT parameters, sex, and age on PSAA detection and CEJ-PSAA distance, respectively. P-values less than 0.05 were considered to indicate statistical significance. Results: The mean CEJ-PSAA distances at the second molar, first molar, second premolar, and first premolar positions were 17.0±4.0 mm, 21.8±4.1 mm, 19.5±4.7 mm, and 19.9±4.9 mm for scanner 1, respectively, and 17.3±3.5 mm, 16.9±4.3 mm, 18.5±4.1 mm, and 18.4±4.3 mm for scanner 2. No independent variable significantly influenced PSAA detection. However, tooth position (b=-0.67, P<0.05) and scanner type (b=-1.3, P<0.05) were significant predictors of CEJ-PSAA distance. Conclusion: CBCT-based estimates of CEJ-PSAA distance were comparable to those obtained in previous studies involving cadavers, CT, and CBCT. The type of CBCT scanner may slightly influence this measurement. No independent variable significantly impacted PSAA detection.

Segmental Liver Stiffness Evaluated with Magnetic Resonance Elastography Is Responsive to Endovascular Intervention in Patients with Budd-Chiari Syndrome

  • Peng Xu;Lulu Lyu;HaitaoGe;Muhammad Umair Sami;Panpan Liu;Chunfeng Hu;Kai Xu
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.773-780
    • /
    • 2019
  • Objective: To assess segmental liver stiffness (LS) with MRI before and after endovascular intervention in patients with Budd-Chiari syndrome (BCS). Materials and Methods: Twenty-three patients (13 males and 10 females; mean age, 42.6 ± 12.6 years; age range, 31-56 years) with BCS as a primary liver disease were recruited for this study. Two consecutive magnetic resonance elastography (MRE) examinations were performed before the endovascular treatment. Fifteen patients who underwent endovascular intervention treatment also had follow-up MRE scans within three days after the procedure. LS was measured in three liver segments: the right posterior, right anterior, and left medial segments. Inter-reader and inter-exam repeatability were analyzed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Segmental LS and clinical characteristics before and after the intervention were also compared. Results: Within three days of the endovascular intervention, all three segmental LS values decreased: LS of the right posterior segment = 7.23 ± 0.88 kPa (before) vs. 4.94 ± 0.84 kPa (after), LS of the right anterior segment = 7.30 ± 1.06 kPa (before) vs. 4.77 ± 0.85 kPa (after), and LS of the left medial segment = 7.22 ± 0.87 kPa (before) vs. 4.87 ± 0.72 kPa (after) (all p = 0.001). There was a significant correlation between LS changes and venous pressure gradient changes before and after treatments (r = 0.651, p = 0.009). The clinical manifestations of all 15 patients significantly improved after therapy. The MRE repeatability was excellent, with insignificant variations (inter-reader, ICC = 0.839-0.943: inter-examination, ICC = 0.765-0.869). Bland-Altman analysis confirmed excellent agreement (limits of agreement, 13.4-19.4%). Conclusion: Segmental LS measured by MRE is a promising repeatable quantitative biomarker for monitoring the treatment response to minimally invasive endovascular intervention in patients with BCS.

High-Resolution CT Findings of Active Pulmonary Tuberculosis : Different Features Between AFB Stain Positive and Negative Group (활동성 폐결핵의 HRCT 소견 : 객담 도말 양성군과 음성군간의 비교)

  • An, Jeon-Ok;Yoon, Bo-Ra;Jung, Jin-Young;Kim, Yoo-Kyung;Baek, Man-Sun;Kim, Ki-Up;Na, Moon-Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.709-719
    • /
    • 2000
  • Background : The different features of high-resolution CT(HRCT) findings of active pulmonary tuberculosis(TB) were studied between acid fast bacilli(AFB) smear or culture positive and negative group. Methods : We prospectively evaluated 36 patients who had been confirmed for active pulmonary tuberculosis by the smear or culture of AFB in sputum(n=25), and changes on serial chest radiographs(n=11). The patients were divided into 3 groups by the results of sputum AFB stain and culture. Group 1(n= 11) is negative in both AFB stain and culture; group 2(n=13) is negative in AFB stain but positive in culture ; and group 3(n=12) is positive in both AFB stain and culture. We evaluated the findings of HRCT in each group randomly. Result : On the HRCT scans, acinar nodule(100%), macronodule(75%), and cavity(75%) in group 3 were more frequently found than group 1(63%. 18%, 9%) and group 2(46%, 15%, 23%)(p<0.05). The centrilobular nodule and branching structure were more frequently observed in group 3(92%) than in group 1(54%)(p<0.05), but were similarly observed in group 2(77%)(p>0.05). AFB positive group was statistically different than the negative group in the HRCT findings with to acinar nodule(100% vs 54%), macronodule(75% vs 17%), and cavity(75% vs 17%)(p<0.05). TB culture positive group was statistically different than the negative group in the HRCT findings with respect to acinar nodule(72% vs 45%) and cavity(48% vs 9%)(p<0.05). Conclusions : HRCT scans are helpful in determining disease acitivity in sputum AFB stain-negative pulmonary tuberculosis. When HRCT shows centrilobular nodule and branching structure, acinar nodule, macronodule, cavity, further studies as sputum induction and bronchoscopy can be performed to determine the presence of bacilli in patients of AFB stain-negative tuberculosis.

  • PDF

Omental Infarction Following Laparoscopy-assisted Gastrectomy (LAG) for Gastric Cancer (위암 환자의 복강경 위절제술 후 발생한 그물막 경색의 임상적 의의)

  • Kim, Min-Chan;Jung, Ghap-Joon;Oh, Jong-Young
    • Journal of Gastric Cancer
    • /
    • v.10 no.1
    • /
    • pp.13-18
    • /
    • 2010
  • Purpose: Omental infarction (OI) following laparoscopy-assisted gastrectomy (LAG) for gastric cancer could become more common in the future because the indications for LAG are expected to expand. The aim of this study was to determine the clinical characteristics of OI following LAG. Materials and Methods: Three hundred ninety patients who underwent LAG for T1 or T2 gastric cancer from April 2003 to November 2007 were enrolled. OI was diagnosed by two radiologists using the patients' abdominal 16 row-detector CT scans. The clinicopathologic characteristics were retrospectively evaluated in the omental infarction (OI) group and the non-omental infarction (non-OI) group using the gastric cancer database of Dong-A University Medical Center and the medical record. Results: Nine omental infarctions (2.3%) of 390 LAGs were diagnosed. All the OIs could be discriminated from omental metastasis on the initial or follow up CT images. The location of the omental infarctions was on the epigastrium in 3 patients and in the left upper quadrant in 3 patients. The mean size of the OIs was 4.1 cm. Most patients with OI had no signs or symptoms. The body mass index of the OI group was higher than that of the non-OI group (P=0230), and OI was more common in patients who underwent total gastrectomy than in the patients who underwent subtotal gastrectomy (P=0.0011). Conclusion: Laparoscopy-assisted gastrectomy (LAG) with partial omentectomy for gastric cancer can be a cause of secondary OI. Omental infarction after LAG has different clinical characteristics and CT findings that those of other omental infarctions or postoperative omental metastases. Further multicenter study will be needed to evaluate in detail the clinical features of omental infarction after LAG.

The Usefulness of Q.Clear Technique in PET / CT (PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰)

  • Choi, Yong Hoon;Kim, Jung Yul;Choi, Young Sook;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.31-36
    • /
    • 2017
  • Purpose Recently, the performance of PET/CT scanner has been improved and various techniques have been developed to increase the image quality such as Sensitivity and Resolution. The purpose of this study is to evaluate the usefulness of Q.Clear (a fully convergent iterative reconstruction) technique of GE Discovery IQ equipment to enhance the image quality. Materials and Methods All scans were acquired by Discovery IQ (GE Healthcare, MI, USA). In NEMA IEC Body Phantom test, Background to Hot-sphere (10 mm, 13 mm, 17 mm, 22 mm) ratio was 1:4 and scan time was 3 minutes. The images were reconstructed by VPHDs (VUE Point High-Definition + SharpIR) and Q.Clear to evaluate each Contrast. We injected 18F-FDG 187 M㏃ to PET/SPECT Performance Phantom. And then it was scanned for 4 minutes to evaluate Resolution and Uniformity. T-test statistical analysis was performed on SUVmax of small lesions less than 2 cm in 100 clinical patients regardless of disease type. Results In the NEMA IEC Body Phantom, the Contrast was $63.6{\pm}5.7%$ (VPHDs) and $75{\pm}4.8%$ (Q.Clear). In the PET/SPECT Performance Phantom, the Resolution was 9.2 mm (VPHDs) and 7.3 mm (Q.Clear). Uniformity of Q.Clear was 10.8% better than VPHDs. T-test statistic of the clinical patients showed a significant difference of p value of 0.021. Conclusion Both the phantom test and the clinical results showed that the quality of the image was improved in Q.Clear was applied. The SUVmax was highly measured in Q.Clear and the lesions were clearly distinguished visually. Therefore Q.Clear can be useful in various aspects such as dose-reduction, patients evaluation and image analysis.

  • PDF

Diagnostic Value of Transbronchial Lung Biopsy -Including Diagnostic Yield According to Tumor-bronchus Relationship- (경기관지폐생검의 진단적 가치 -병변과 기관지의 관계에 따른 진단율을 포함한 연구-)

  • Kang, Tae-Kyong;Cha, Seung-Ick;Park, Jae-Yong;Chae, Sang-Chul;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.438-447
    • /
    • 2000
  • Background : Transbronchial lung biopsy (TBLB) is a relatively simple and convenient procedure to obtain lung tissue from a patient with diffuse or localized lesion on chest radiographs, whose disease cannot be diagnosed through routine tests. The authors tried to evaluate the diagnostic value of TBLB, especially, the concordance between CT scan and TBLB with respect to the location of the lesion and diagnostic yield according to tumor-bronchus relationship. Method : We reviewed the medical records, plain chest films, and chest CT scans of 278 patients who underwent TBLB at Kyungpook National University Hospital between January 1996 and June 1998. Results : One hundred and sixteen (41.7 %) patients were diagnosed by TBLB. Diagnostic yield of TBLB of malignant tumors tended to be higher than that of benign diseases (64.7% versus 53.9%, p=0.09). Of primary lung cancers, TBLB was more diagnostic in adenocarcinoma and small-cell carcinoma than other cell types (p<0.01) and, of benign diseases, more diagnostic in tuberculosis than in non-tuberculous diseases (p<0.05). There was no significant difference in the diagnostic rate according to the location of the tumor. The diagnostic rate tended to increase with the size of tumor (p=0.06). The diagnootic rate of TBLB did not differ according to the pattern of lesion in benign diseases. However, in malignant diseases TBLB was more diagnostic in diffuse/multiple nodular lesions than in localized lesions(p<0.05). According to the tumor-bronchus relationship, TBLB was more diagnootic in type I/II groups than in other types. CT scan and TBLB showed a strong correlation with respect to the localization of the lesion (r=0.994, p<0.01). Conclusion : The above results show that TBLB is useful in the diagnosis of lung disease. CT scan and TBLB showed a strong correlation in determining the location of the lesion. Diagnostic yield of TBLB is higher in lesions with 'bronchus sign' (type I and II). TBLB and other diagnootic methods such as transthoracic needle aspiration are expected to complement one another in the diagnosis of lung diseases.

  • PDF

The Characteristics of Eosinophilc Lung Diseases Cause by Toxocara Canis Larval Infestation (개회충 유충 감염에서 발생되는 호산구성 폐질환의 특성)

  • Kim, Yu Jin;Kyung, Sun Young;An, Chang Hyeok;Lim, Young Hee;Park, Jung Woong;Jeong, Seong Hwan;Lee, Sang Pyo;Choi, Dong Chull;Jeong, Young Bae;Kang, Shin Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Background: Toxocariasis is a common cause of eosinophilia and eosinophilic lung disease in Korea. We analyzed the characteristics of eosinophilic lung disease in toxocariasis. Method: One hundred and forty one patients with eosinophilia caused by a toxocara larval infection were evaluated from September 1, 2001 through March 30, 2006. The plain chest x-ray, chest CT(computed tomography), and bronchoalveolar larvage(BAL) were examined. A diagnosis of toxocariasis was made by ELISA using that secretory-excretory antigen from the T. canis larvae. Results: Toxocarial eosinophilic lung diseases was diagnosed in 32 out of 141 patients. Ground glass attenuation was the main feature on the CT scans in 23 out of 141 patients (71.9%). Thirteen patients (40.6%) had a random in zonal distribution on CT. Pleural effusion was observed in 9 patients (28.1%). Twenty eight patients (87.5%) complained of respiratory symptoms. Eleven patients (34.4%) had gastrointestinal symptoms and 12 patients (37.5%) had liver infiltration. Conclusions: The most common findings of the chest CT in patients with toxocariasis was a randomly distributed ground grass attenuation. A toxocara infection should be considered in a differential diagnosis of patients who exhibit pulmonary infiltration with eosinophilia in Korea.

Analysis of masseter muscle in facial asymmetry before and after orthognathic surgery using 3-dimensional computed tomography (3차원 전산화 단층 사진을 이용한 안면비대칭 환자의 악교정 수술 전, 후 교근 분석)

  • Seo, Seung-Ah;Baik, Hyoung-Seon;Hwang, Chung-Ju;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.18-27
    • /
    • 2009
  • Objective: The purpose of this study was to understand the differences in masseter muscle(MM) between the shifted and non-shifted sides in facial asymmetry patients, and the changes shown by MM after mandibular surgery. Methods: Pre- and post-operative CT scans were performed on 12 Class III patients with facial asymmetry who were treated by intraoral vertical ramus osteotomy and 10 subjects with normal occlusion. Using the V-works 4.0 program(Cybermed, Seoul, Korea), 3-dimensional images of the mandible, and MM were reconstructed, and evaluated. Results: In the asymmetry group, the MM angle between the shifted and non-shifted sides was only significantly different(p<0.05). Compared with normal occlusion, the asymmetry group showed a significantly smaller volume and maximum cross-sectional area in both sides of MM(p<0.05). After mandibular surgery, the angle of MM(p<0.01) and differences in angle between the shifted and non-shifted sides of MM(p<0.05) were significantly decreased. The thickness in the maximum cross-sectional area was significantly increased(p<0.01). After surgery, MM in facial asymmetry patients was similarly changed to those in the normal occlusion group except for widths. Conclusions: MM in facial asymmetry was definitely different from those in normal occlusion. However, this study suggests that MM changed symmetrically in conjunction with the mandible after proper mandibular surgery.

The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation (골반강 방사선치료 중 소장의 이동을 위한 벨리보드의 효과에 대한 3차원적 분석)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.271-279
    • /
    • 2008
  • Purpose: To evaluate the efficacy of a belly-board device (BBD) in reducing the volume of small bowel during four-field pelvic irradiation. Materials and Methods: Twenty-two cancer patients (14 uterine cervical cancer, 6 rectal cancer, and 2 endometrial cancer) scheduled to receive pelvic irradiation were selected for this study. Two sets of CT images were taken with and without the belly-board device using the Siemens 16 channel CT scanner. All patients were set in the prone position. The CT images were transferred to a treatment planning system for dose calculation and volume measurements. The external surfaces of small bowel and the bladder were contoured on all CT scans and the 4-pelvic fields were added. The dose-volume-histogram of the bladder and small bowel, with and without the BBD, were plotted and analyzed. Results: In all patients, the total small bowel volume included in the irradiated fields was reduced when the BBD was used. The mean volume reduction was 35% (range, $1{\sim}79%$) and was statistically significant (p<0.001). The reduction in small bowel volume receiving $10{\sim}100%$ of the prescribed dose was statistically significant when the BBD was used in all cases. Almost no change in the total bladder volume involved was observed in the field (<8 cc, p=0.762). However, the bladder volume receiving 90% of the prescribed dose was 100% in 15/22 patients (68%) and $90{\sim}99%$ in 7/22 patients (32%) with the BBD. In comparison, the bladder volume receiving 90% of the prescribed dose was 100% in 10/22 patients (45%), $90{\sim}99%$ in 7/22 patients (32%), and $80{\sim}89%$ in 5/22 patients (23%) without the BBD. When the BBD was used, an increase in the bladder volume receiving a high dose range was observed Conclusion: This study shows that the use of a BBD for the treatment of cancer in the pelvic area significantly improves small bowel sparing. However, since the BBD pushed the bladder into the treatment field, the bladder volume receiving the high dose could increase. Therefore it is recommended to be considerate in using the BBD when bladder damage is of concern.