• Title/Summary/Keyword: CT 시편

Search Result 95, Processing Time 0.076 seconds

Percolation Analysis On Porous Concrete Using Microstructural CT Image Processing and Probability Distribution Functions (투수 콘크리트의 미세구조 CT 이미지와 확률 분포 함수를 사용한 투수성 분석)

  • Chung, Sang-Yeop;Han, Tong-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.31-37
    • /
    • 2012
  • The phase distribution in concrete materials strongly affects its material properties. It is important to identify the spatial distribution of void in concrete because the void in concrete materials affects mechanical behavior and permeability significantly. Therefore, a proper method to describe the void distribution of a material is needed. In this research, CT(computed tomography) is used to examine and to quantify the void distribution of porous concrete specimens. 3D concrete digital specimens are created by subsequent stacking of 2D cross-sectional images from CT. Then, probability distribution functions such as two-point correlation, lineal-path and two-point cluster functions are used for void distribution characterization. It is confirmed that probability distribution functions obtained from CT images are effective in characterizing void distributions including the anisotropy and percolation.

Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns (전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교)

  • Ko, In-Seok;Kim, Jeong-Mi;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.226-233
    • /
    • 2016
  • Purpose: The purpose of this study was to evaluate the adaptation of lithium disilicate crowns fabricated by CAD-CAM (computer aided design-computer aided manufacturing) and heat-press technique to compare two different measurement methods in assessing fit of the ceramic crowns: micro CT and cross-section technique. Materials and methods: A prepared typodont mandibular molar for ceramic crown was duplicated and ten dies were produced by milling the PMMA (polymethylmethacrylate) resin. Ten vinyl polysiloxane impressions were made and stone casts were produced. Five dies were used for IPS e.max Press crowns with heat-press technique. The other five dies were used for IPS e.max CAD crowns with CAD-CAM technique. Ten lithium disilicate crowns were cemented on the resin dies using zinc phosphate cement with finger pressure. The marginal and internal fits in central buccolingual plane were evaluated using a micro CT. Then the specimens were embedded and cross-sectioned and the marginal and internal fits were measured using scanning electronic microscope. The two measurement methods and two manufacturing methods were compared using Mann-Whitney U test (SPSS 22.0). Results: The marginal and internal fit values using micro CT and cross-section technique were similar, showing no significant differences. There were no significant differences in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique. Conclusion: Both micro CT and cross-section technique were acceptable methods in the evaluation of marginal and internal fit of lithium disilicate crown. There was no difference in adaptation between lithium disilicate crowns fabricated with CAD-CAM and heat-press technique except occlusal fit.

Studies on effects of calibration methods and current lead position on the direct current potential drop method for crack length measurement (직류전압강하법에 의한 균열길이 측정에 미치는 도선의 위치 및 보정방법의 영향에 관한 연구)

  • Cho, C.C.;Kim, I.S.;Kim, S.S.;Choe, S.J.;Hur, B.Y.
    • Analytical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.300-306
    • /
    • 1997
  • The effective resolution of the direct current potential drop (DCPD) method for crack length determination is strongly affected by a number of factors including wire locations and calibration method. In the present study, the effects of wire locations, thermal EMF and reference probe locations on the accuracy of calibration methods, including Hicks-Pickard equation and Johnson's equation, were examined with the CT specimens which were nine times larger than the standard specimen. In light of experimental results, it was found that Hicks-Pickard equation can accurately represent the a/W-V/Vo relationship when current input wire is located at the load line. It was also found that the accuracy of DCPD method can be greatly improved with the thermal EMF calibration and the use of Vo value at a/W = 0.241. The use of reference potential was found to be impractical when current input wire is located at the load line.

  • PDF

A Study on Tensile Properties of CFRP Composites under Cryogenic Environment (극저온 환경에서 탄소섬유강화 복합재의 인장 물성에 관한 연구)

  • Kim Myung-Gon;Kang Sang-Guk;Kim Chun-Gon;Kong Cheol-Won
    • Composites Research
    • /
    • v.17 no.6
    • /
    • pp.52-57
    • /
    • 2004
  • In this study, mechanical tensile properties of carbon fiber reinforced polymeric (CFRP) composite cycled with thermo-mechanical loading under cryogenic temperature (CT) were measured using cryogenic environmental chamber. Thermo-mechanical tensile cyclic loading (up to 10 times) was applied to graphite/epoxy unidirectional laminate composites far room temperature (RT) to $-50^{\circ}C$, RT to $-100^{\circ}C$ and RT to $-150^{\circ}C$. Results showed that tensile stiffness obviously increased as temperature decreased while the thermo-mechanical cycling has little influence on it. Tensile strength, however, decreased as temperature down to CT while the reduction of strength showed little after CT-cycling. For the analysis of the test results, coefficient of thermal expansion (CTE) of laminate composite specimen at both RT and CT were measured and the interface between fiber and matrix was observed using SEM images.

Evaluation of Color Change according to Process Step of Fused Porcelain to SLM Method (치과용 레이저 선택가공 금속체의 도재 소성단계에 따른 색조변화 관찰)

  • Kim, Chi-Young;Chung, In-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.12
    • /
    • pp.236-242
    • /
    • 2010
  • The porcelain fused metal was made through the progressive fused process of porcelain on substructure of metal material. The substructure was made using novel SLM method. The objective of this study was to observe the color change of porcelain using spectrophotometer equipment according to porcelain fused step and production methods after conducting the process of casting and SLM method of the substructure. The color change by step was indicated that fused opaque porcelain groups(CN1, CC1, CT1, SC1, ST1) had color difference(${\Delta}E$=30) by comparison with fused body porcelain groups(CN2, CC2, CT2, SC2, ST2) and fused glazing porcelain groups(CN3, CC3, CT3, SC3, ST3) (p<0.05). and there was no color difference between the substrates(CN, CC, CT) made by the casting method and the substrates(SC, ST) made by the SLM method. so, the color change was expressed by fused change of porcelain, and this study showed that the color of porcelain fused metal made by the SLM method can be applied clinical trials.

Fiber Orientation and Warpage of Film Insert Molded Parts with Glass Fiber Reinforced Substrate (유리섬유가 강화된 필름 삽입 사출품의 섬유배향 및 휨)

  • Kim, Seong-Yun;Kim, Hyung-Min;Lee, Doo-Jin;Youn, Jae-Ryoun;Lee, Sung-Hee
    • Composites Research
    • /
    • v.25 no.4
    • /
    • pp.117-125
    • /
    • 2012
  • Warpage of the film insert molded (FIM) part is caused by an asymmetric residual stress distribution. Asymmetric residual stress and temperature distribution is generated by the retarded heat transfer in the perpendicular direction to the attached film surface. Since warpage was not prevented by controlling injection molding conditions, glass fiber (GF) filled composites were employed as substrates for film insert molding to minimize the warpage. Distribution of short GFs was evaluated by using micro-CT equipment. Proper models for micro mechanics, anisotropic thermal expansion coefficients, and closure approximation should be selected in order to calculate fiber orientation tensor and warpage of the FIM part with the composite substrate. After six kinds of micro mechanics models, three models of the thermal expansion coefficient and five models of the closure approximation had been considered, the Mori-Tanaka model, the Rosen and Hashin model, and the third orthotropic closure approximation were selected in this study. The numerically predicted results on fiber orientation tensor and warpage were in good agreement with experimental results and effects of GF reinforcement on warpage of the FIM composite specimen were identified by the numerical results.

Measurement of Deformation field in CT specimen using Laser speckle (레이저 스페클을 이용한 CT 시험편의 변형장 측정)

  • Jean, Moon-Chang;Kang, Ki-Ju
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.192-197
    • /
    • 2001
  • To obtain $A_2$ experimentally in the $J-A_2$ theory, deformation field on the lateral surface of a CT specimen was to be determined using Laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure $A_2$ continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and $A_2$ were explored.

  • PDF

Morphological Analysis of Hydraulically Stimulated Fractures by Deep-Learning Segmentation Method (딥러닝 기반 균열 추출 기법을 통한 수압 파쇄 균열 형상 분석)

  • Park, Jimin;Kim, Kwang Yeom ;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.8
    • /
    • pp.17-28
    • /
    • 2023
  • Laboratory-scale hydraulic fracturing experiments were conducted on granite specimens at various viscosities and injection rates of the fracturing fluid. A series of cross-sectional computed tomography (CT) images of fractured specimens was obtained via a three-dimensional X-ray CT imaging method. Pixel-level fracture segmentation of the CT images was conducted using a convolutional neural network (CNN)-based Nested U-Net model structure. Compared with traditional image processing methods, the CNN-based model showed a better performance in the extraction of thin and complex fractures. These extracted fractures extracted were reconstructed in three dimensions and morphologically analyzed based on their fracture volume, aperture, tortuosity, and surface roughness. The fracture volume and aperture increased with the increase in viscosity of the fracturing fluid, while the tortuosity and roughness of the fracture surface decreased. The findings also confirmed the anisotropic tortuosity and roughness of the fracture surface. In this study, a CNN-based model was used to perform accurate fracture segmentation, and quantitative analysis of hydraulic stimulated fractures was conducted successfully.

고온 염기성 수용액에서 $TiO_2$가 Alloy 600과 Alloy 690의 응력부식파괴에 미치는 영향

  • 김경모;김홍표;이창규;국일현;김우철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.78-83
    • /
    • 1998
  • Alloy 600과 Alloy 690의 응력부식파괴(Stress corrosion cracking, SCC)에 미치는 TiO$_2$의 영향을 315$^{\circ}C$의 10%NaOH 수용액에서 RUB(reverse U-bend) 시편, C-Ring 시편과 CT(compact tension)시편을 사용하여 평가하였다. 시편은 alloy 600 MA(mill anneal), alloy 600 TT(thermal treatment) 그리고 alloy 690 TT로 제작하였다. SCC 시험은 탈산된 10%NaOH 수용액에 2 g/1 TiO$_2$를 첨가한 용액과 첨가하지 않은 용액에서 수행하였으며, 이 조건에서 분극곡선도 얻었다. SCC 시험시 시편을 부식전위로부터 +150 ㎷ 양극분극을 가하였다. 기준전극으로 external Ag/AgCl electrode를 사용하였다. Alloy 600 MA로 제작한 RUB 시편은 TiO$_2$가 없는 용액에서 5일 안에 벽 관통 균열을 보였으나 TiO$_2$가 첨가된 용액에서는 균열을 관찰할 수 없었다. TiO$_2$가 첨가됨에 따라 alloy 600과 alloy 690의 임계전류밀도는 크게 감소하였고 또한 부동태 전류밀도도 감소하였다. 부동테 영역에서 TiO$_2$가 있는 용액의 경우 여러 peak가 있는 반면에 TiO$_2$가 없는 용액은 peak가 뚜렷하지 않았다. 이런 결과는 TiO$_2$가 첨가점에 따라 active region에서도 안정한 부동태 피막이 존재한다는 것을 시사한다. 또한 TiO$_2$가 없는 경우 SCC가 잘 일어나는 영역에 존재하는 부동태 피막이 TiO$_2$ 첨가에 따라 repassivation kinetics 등의 성질이 변화한 것으로 판단된다.

  • PDF

EVALUATION OF THE EFFECTIVENESS OF THERAPEUTIC SEALING ACCORDING TO THE LESION DEPTHS OF PROXIMAL EARLY CARIES (인접면 초기 우식 병소의 깊이에 따른 therapeutic sealing의 유효성 평가)

  • Lee, Geum-Lang;Ahn, Myung-Ki;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.394-403
    • /
    • 2009
  • As the minimally invasive approach against white spot like early caries lesions in proximal surfaces of the teeth, therapeutic sealing has been introduced and studied for effective materials and methods to arrest the early caries lesion effectively, which is still going on. This study was performed for the purpose of evaluating its validity for the non-cavitated lesions according to the depth from surface using therapeutic sealing followed by artificial caries induction and evaluation with micro-CT, and we obtained the results as follows. 1. It was revealed that the deeper the caries lesions are, the lower radiation intensity at lesion body areas in pre-treatment specimen. 2. In the sealed groups, there were no differences in radiation intensity between pre- and post-treatment, whereas there were significant decreases in unsealed groups(p<0.05). 3. Even in the specimens with the lesions reaching deeply into DEJ, the effect of sealing was significant(p<0.05). Conclusively, it was thought therapeutic sealing can be an effective tool against the early caries lesions, regardless of their depth into tooth, unless cavitated.

  • PDF