• Title/Summary/Keyword: CSA

Search Result 514, Processing Time 0.03 seconds

An Application of Shrinkage Compensation Mortar in Construction Field (수축 보상 모르타르의 현장 적용 연구)

  • 김기동;정성철;송명신;이경희
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.3-10
    • /
    • 2000
  • In this study, we compared a plain mortar with the CAS-system shrinkage compensation mortar for Ondol that is Korean traditional heating system. The Ondol mortar is necessary to have properties as non-crack, fine flatness and stability for thermal changes. especially, mortar'crack prevention is to be most important property in Ondol mortar. To develope the stable material on the crack-prevention, we used to calcium-sulfo-aluminate(CSA)system in shrinkage compensation mortar. And so, we confirmed the effects of calcium-sulfo-aluminate(CSA) system for mortar's physical properties such as setting time, compressive strength and expansion ratio for crack prevention. The initial and final setting time of the CSA mortar is faster than plain mortar about 2hours. And, Compressive strength increased about 20% that plain mortar. The crack length per unit area, plain mortar is 0.426∼0.481m/m2. The Results of apartment construction field test, the shrinkage compensation mortar is excellent about the crack-reduce effect.

Red emission organic light-emitting diode with electrochemically deposited PANI-CSA layer

  • Kim, Ju-Seung;Kim, Dae-Jung;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.81-84
    • /
    • 2003
  • Conductive polyaniline(PANI)-camphosulfonic acid (CSA) film applied as a hole injection layer in ITO/PANI/P3HT/LiF/Al device. In the AFM images, electrochemically polymerized PANI-CSA films have the small particles and smooth sufficient for application as hole injection layer. By insertion of PANI-CSA buffer layer, the turn on voltage of ITO/PANI/P3HT/LiF/Al device lowed by 3V, whereas that of ITO/P3HT/LiF/Al device shows 5V.

  • PDF

Value of Ultrasonography in the Diagnosis of Carpal Tunnel Syndrome : Correlation with Electrophysiological Abnormalities and Clinical Severity

  • Kim, Min-Kyu;Jeon, Hong-Jun;Park, Se-Hyuck;Park, Dong-Sik;Nam, Hee-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.2
    • /
    • pp.78-82
    • /
    • 2014
  • Objective : To investigate a diagnostic value of ultrasonography in carpal tunnel syndrome (CTS) patients and to evaluate a correlation of sonographic measurements with the degree of electrodiagnostic abnormalities and clinical severity. Methods : Two-hundred-forty-six symptomatic hands in 135 patients and 30 asymptomatic hands in 19 healthy individuals as control group were included. In ultrasonographic study, we measured the cross-sectional area (CSA) and flattening ratio (FR) of the median nerve at the pisiform as well as palmar bowing (PB) of the flexor retinaculum. Sensitivity and specificity of ultrasonographic measurements were evaluated and ultrasonographic data from the symptomatic and control hands were compared to the grade of electrodiagnostic and clinical severity. Results : The mean CSA was $13.7{\pm}4.2mm^2$ in symptomatic hands and $7.9{\pm}1.3mm^2$ in asymptomatic hands. The mean FR was $4.2{\pm}1.0$ in symptomatic hands and $3.4{\pm}0.4$ in asymptomatic hands. The mean PB was $3.5{\pm}0.5$ mm in symptomatic hands and $2.6{\pm}0.3$ mm in asymptomatic hands. Statistical analysis showed differences of the mean CSA, FR and PB between groups were significant. A cut-off value of $10mm^2$ for the mean CSA was found to be the upper limit for normal value. Both the mean CSA and PB are correlated with the grade of electrophysiological abnormalities and clinical severity, respectively. Conclusion : Ultrasographic measurement of the CSA and PB is helpful to diagnose CTS as a non-invasive and an alternative modality for the evaluation of CTS. In addition, ultrasonography also provides a reliable correlation with the grade of electrodiagnostic abnormalities and clinical severity.

A Study on the Impact of CSA on Internal Control (CSA가 내부통제에 미치는 영향)

  • Park, Seong-Kyu;Heo, Young-Kyun;Jeong, Jeong-Seob
    • Korean Business Review
    • /
    • v.18 no.2
    • /
    • pp.45-60
    • /
    • 2005
  • CSA(Control Self Assessment) is a new internal control technique whose objective is to control the human resource performance, the manager's philosophy, the business ethics, the effective communication and decision making etc. The purpose of this study is to find out if the CSA improve the quality of internal control. With the questionnaire method the following conclusions are reached. 1) Level of the management supports influence the level of the workshop participation. 2) Anonymity during the workshop session influences the level of workshop participation. 3) Level of the organizational committment influences the level of the participation 4) The level of workshop performance significantly influences the level of internal contro improvement.

  • PDF

The Effect of Camphorsulfonic Acid in TEMPO-Mediated Bulk and Dispersion Polymerization of Styrene

  • Oh Sejin;Kim Gijung;Ko Narae;Shim Sang Eun;Choe Soonja
    • Macromolecular Research
    • /
    • v.13 no.3
    • /
    • pp.187-193
    • /
    • 2005
  • The TEMPO-mediated living free-radical bulk and dispersion polymerization of styrene in the presence of camphorsulfonic acid (CSA) are investigated. In the absence of TEMPO and CSA in the bulk polymerization, a conversion of $93\%$ is achieved within 6 hr of polymerization. When only TEMPO is involved in this polymerization, the pseudo-living free-radical polymerization is well achieved, however, the polymerization rate becomes quite slow. This retardation of the polymerization rate is solved by the addition of a low concentration of CSA. In the TEMPO-mediated dispersion polymerization in the presence of CSA, similar trends in the conversion, kinetics, and PDI are observed as those observed in the case of bulk polymerization. When only TEMPO is used in the dispersion polymerization, the resulting particle size becomes quite broad, due to the prolonged polymerization time. However, when a 1.0 molar ratio of CSA to TEMPO is added to the TEMPO-mediated dispersion polymerization, fairly mono-disperse PS microspheres having an average size of 5.83 $\mu$m and a CV of 3.4$\%$ are successfully obtained, due to the narrow molecular weight distribution of the intermediate oligomers and shortening of the polymerization time. This result indicates that the addition of CSA to the TEMPO-mediated bulk and the use of dispersion polymerization not only shortens the polymerization time, but also greatly improves the uniformity of the microspheres.

Synthesis of Sulfonated Polyethersulfone Membrane Material for Ultrafiltration by Heterogeneous Sulfonation and Fouling Reduction Effect (불균일계 술폰화에 의한 한외여과용 폴리에테르 술폰 막소재 합성과 fouling 감소효과)

  • 김인철;최중구;최남석;김종호;탁태문
    • Membrane Journal
    • /
    • v.8 no.4
    • /
    • pp.210-219
    • /
    • 1998
  • Sulfonated poly(ether sulfone)(SPES) of various ion exchange capacity (IEC) was prepared by heterogeneous sulfonation with chlorosulfonic acid (CSA) to make hydrophilic ultrafiltration membrane for reducing fouling. The effects of CSA concentration, reaction temperature and reaction time has been investigated. The reaction was effective when the temperature is above 10$\circ$C and the CSA concentration is over 0.05 mol, although polymer chain has been significantly degraded. The substitution of sulfonic acid groups was characterized by FTIR and $^1$H-NMR. Transport properties and fouling test have been conducted to the modified SPES ultrafiltration rnembranrs by heterogeneors method. Membranes were obtained using DCM and PVP as a non-solvent and pore forming agent, respectively. Flux reduced and rejection increased with ion exchange capacity. Finger-like structure was disappeared and the thickness of top layer was increased. Dense membrane by non-solvent DCM and porous membrane by pore forming agent PVP was prepared. Fouling was reduced with increasing ion exchange capacity because of hydrophilicity.

  • PDF

Scalable Dual-Field Montgomery Multiplier Using Multi-Precision Carry Save Adder (다정도 CSA를 이용한 Dual-Field상의 확장성 있는 Montgomery 곱셈기)

  • Kim, Tae-Ho;Hong, Chun-Pyo;Kim, Chang-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1C
    • /
    • pp.131-139
    • /
    • 2008
  • This paper presents a scalable dual-field Montgomery multiplier based on a new multi-precision carry save adder(MP-CSA), which operates in both types of finite fields GF(p) and GF($2^m$). The new MP-CSA consists of two carry save adders(CSA). Each CSA is composed of n = [w/b] carry propagation adders(CPA) for a modular multiplication with w-bit words, where b is the number of dual field adders(DFA) in a CPA. The proposed Montgomery multiplier has roughly the same timing complexity compared with the previous result, however, it has the advantage of reduced chip area requirements. In addition, the proposed circuit produces the exact modular multiplication result at the end of operation unlike the previous architecture. Furthermore, the proposed Montgomery multiplier has a high scalability in terms of w and m. Therefore, it can be used to multiplier over GF(p) and GF($2^m$) for cryptographic applications.

Influence of Cement Matrix's Compressive Strength and Replacement of Expansive Admixture on the Mechanical Properties of Synthetic Polyethylene (PE) Fiber-Reinforced Strain-Hardening Cement-Based Composites (SHCCs) (압축강도와 팽창재 대체에 따른 폴리에틸렌 합성섬유로 보강된 변형 경화형 시멘트 복합체의 역학적 특성)

  • Song, Young Jae;Yun, Hyun Do;Min, Byung Sung;Rokugo, Keitetsu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • In order to improve the dimensional stability and mechanical performance of cement-based composites, the effect of an expansive admixture based on calcium sulphoaluminate (CSA) on the shrinkage and mechanical properties of strain-hardening cement-based composite (SHCC), which exhibits multiple cracks and pseudo strain-hardening behavior in the direct tension, is investigated. Polyethylene fibers reinforced SHCC mixtures with three levels (30, 70, and 100MPa) of compressive strength were compared through free shrinkage, compressive strength, flexural strength, and direct tensile strength measurements. The SHCC mixtures were cast with and without replacing 10% of Portland cement content with CSA admixture. According to test results, CSA admixture is effective in reducing shrinkage of SHCC material. SHCC mixture with CSA admixture exhibited a little higher strength than companion mixture without CSA admixture.

Development of Gated Myocardial SPECT Analysis Software and Evaluation of Left Ventricular Contraction Function (게이트 심근 SPECT 분석 소프트웨어의 개발과 좌심실 수축 기능 평가)

  • Lee, Byeong-Il;Lee, Dong-Soo;Lee, Jae-Sung;Chung, June-Key;Lee, Myung-Chul;Choi, Heung-Kook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • Objectives: A new software (Cardiac SPECT Analyzer: CSA) was developed for quantification of volumes and election fraction on gated myocardial SPECT. Volumes and ejection fraction by CSA were validated by comparing with those quantified by Quantitative Gated SPECT (QGS) software. Materials and Methods: Gated myocardial SPECT was peformed in 40 patients with ejection fraction from 15% to 85%. In 26 patients, gated myocardial SPECT was acquired again with the patients in situ. A cylinder model was used to eliminate noise semi-automatically and profile data was extracted using Gaussian fitting after smoothing. The boundary points of endo- and epicardium were found using an iterative learning algorithm. Enddiastolic (EDV) and endsystolic volumes (ESV) and election fraction (EF) were calculated. These values were compared with those calculated by QGS and the same gated SPECT data was repeatedly quantified by CSA and variation of the values on sequential measurements of the same patients on the repeated acquisition. Results: From the 40 patient data, EF, EDV and ESV by CSA were correlated with those by QGS with the correlation coefficients of 0.97, 0.92, 0.96. Two standard deviation (SD) of EF on Bland Altman plot was 10.1%. Repeated measurements of EF, EDV, and ESV by CSA were correlated with each other with the coefficients of 0.96, 0.99, and 0.99 for EF, EDV and ESV respectively. On repeated acquisition, reproducibility was also excellent with correlation coefficients of 0.89, 0.97, 0.98, and coefficient of variation of 8.2%, 5.4mL, 8.5mL and 2SD of 10.6%, 21.2mL, and 16.4mL on Bland Altman plot for EF, EDV and ESV. Conclusion: We developed the software of CSA for quantification of volumes and ejection fraction on gated myocardial SPECT. Volumes and ejection fraction quantified using this software was found valid for its correctness and precision.