• 제목/요약/키워드: CNR

검색결과 526건 처리시간 0.027초

Flexible electronics based on polysilicon thin film transistor

  • Fortunato, G.;Cuscuna, M.;Maiolo, L.;Maita, F.;Mariucci, L.;Minotti, A.;Pecora, A.;Simeone, D.;Valletta, A.;Bearzotti, A.;Macagnano, A.;Pantalei, S.;Zampetti, E.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.258-261
    • /
    • 2009
  • In this work we present a process to fabricate lowtemperature polysilicon (LTPS) TFTs on polyimide (PI) layers, spin-coated on Si-wafer used as rigid carrier. This process has been then used to fabricate elementary circuits as well as circuits for sensor applications.

  • PDF

Drain induced barrier lowering and impact ionization effects in short channel polysilicon TFTs

  • Fortunato, G.;Valletta, A.;Gaucci, P.;Mariucci, L.;Cuscuna, M.;Maiolo, L.;Pecora, A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.907-910
    • /
    • 2008
  • The effect of channel length reduction on the electrical characteristics of self-aligned polysilicon TFTs has been investigated by combining experimental characteristics and 2-D numerical simulations. The role of drain induced barrier lowering and floating body effects has been carefully analized using numerical simulations.

  • PDF

관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로 (Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current)

  • 서영현;송종남
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.371-379
    • /
    • 2019
  • 관상동맥 조영술(CAG)의 씨네(Cine) 촬영에서 엑스선 촬영 조건의 변화가 입사 표면 선량(ESD)과 흡수선량(DAP)에 미치는 관계를 알아보고자 하였고 image J 프로그램을 통해 촬영된 혈관 조영 영상의 SNR과 CNR을 측정 분석하여 조건 변화가 선량관계 및 영상의 질에 미치는 유용성을 분석하고자 하였다. 2017년 11월부터 2018년 3월까지 본원에서 CAG를 시행한 33명(남24, 여9)의 데이터를 대상으로 하였고, 연령대는 37-76세(평균 $59{\pm}10$세), 몸무게53-104kg (평균 $72{\pm}10kg$), 키150-185cm (평균 $166.82{\pm}9.5kg$), BMI 18.3-33.2(평균 $25.8{\pm}3.2$)이었다. 촬영조건 및 데이터 획득은 관전류(mA)를 높게 한 A그룹(397.2mA)과 mA를 낮게 한 B그룹(370.7mA)의 ESD와 DAP를 후향적으로 획득하여 비교 분석 하였고 Image J를 통한 SNR과 CNR 측정 분석은 획득한 데이터를 공식에 대입하여 결과 값을 도출하였다. 통계프로그램은 SPSS (PASW)를 사용하여 촬영조건 변화에 따른 ESD와 DAP 및 SNR CNR의 상관관계 등을 분석하였다. 촬영조건의 mA에 변화를 주어 촬영한 A그룹과 B그룹의 ESD($A:483.5{\pm}60.1$, $B: 464.4{\pm}39.9$)와 DAP($A:84.3{\pm}10.7$, $B:81.5{\pm}7$)간의 관계는 통계적으로 유의하지 않았다(p>0,05). Image J를 통한 SNR과 CNR의 관계에선 B그룹의 좌심장동맥(LCA)을 촬영해 얻은 영상의 SNR($5.451{\pm}0.529$), CNR($0.411{\pm}0.0432$)이 A그룹 좌심장동맥(LCA)의 SNR($4.976{\pm}0.433$), CNR($0.459{\pm}0.0431$)보다 SNR $0.475{\pm}0.096$, CNR $-0.048{\pm}0.0$로 차이가 있었으나 통계적으로 유의하지는 않았다(p<0.05). 우심장동맥(RCA)을 촬영해 획득한 SNR과 CNR에선 A그룹의 SNR($4.731{\pm}0.773$)과 CNR($0.354{\pm}0.083$)이 B그룹의 SNR($3.24{\pm}0.368$), CNR($0.166{\pm}0.033$)보다 SNR $1.491{\pm}0.405$, CNR $0.188{\pm}0.005$로 증가된 수치를 나타냈으며 그 중 CNR이 통계적으로 유의했다(p<0.05). 상관관계 분석 결과에서는 SNR (LCA) & CNR (LCA), SNR (RCA) & CNR (RCA), ESD & DAP, ESD & sec, DAP & CNR (RCA), DAP & sec간에 통계적으로 유의한 차이를 나타냈다(p<0.05). SNR과 CNR이 높을수록 선명하고 좋은 화질을 나타냄을 의미하는데 화질평가 및 선량변화 유용성에 관한 분석 연구를 진행한 결과 mA를 증가시켜 촬영 한 CAG의 RCA영상에서 SNR과 CNR이 증가된 수치를 보였다. 특히, CNR이 통계적으로 유의한 차이를 나타낸 것을 보았을 때 RCA촬영 시 mA를 향상시켜 촬영 할 경우 영상의 질 중 대조도가 한층 더 향상 될 수 있을 것으로 사료된다.

Expression, Purification, Crystallization and Preliminary X-Ray Crystallographic Analysis of CnrX from Cupriavidus metallidurans CH34

  • Kim, Kook-Han;Jung, Eun-Jung;Im, Ha-Na;Lelie, Daniel Van Der;Kim, Eunice Eun-Kyeong
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권1호
    • /
    • pp.43-47
    • /
    • 2008
  • The nickel and cobalt resistance of Cupriavidus metallidurans CH34 is mediated by the CnrCBA efflux pump encoded by the cnrYHXCBAT metal resistance determinant. The products of the three genes cnrYXH transcriptionally regulate expression of cnr. CnrY and CnrX are membrane-bound proteins, probably functioning as anti-sigma factors, whereas CnrH is a cnr-specific extracytoplasmic functions (ECF) sigma factor. The periplasmic domain of CnrX (residues 29-148) was cloned as a N-terminal His-tagged protein, expressed in Escherichia coli, and purified using affinity chromatography and gel filtration. The molecular mass was estimated to be about 13.6kDa by size exclusion chromatography, corresponding to a monomer. The tetragonal bipyramid crystals were obtained by mixing an equal volume of protein in 50mM Tris-HCl, pH 7.5, 1% glycerol, 100mM NaCl, 1mM DTT, and the reservoir solution of 15% w/v PEG 2000, 100mM lithium chloride at 277K in 2-4 days using hanging drop vapor diffusion. The protein concentration was 24mg/ml. The crystal that diffracted to $2.42{\AA}$ resolution belongs to space group $P4_1\;or\;P4_3$ with unit cell parameters of $a=b=32.14{\AA},\;c=195.31{\AA},\;{\alpha}={\beta}={\gamma}=90^{\circ}$, with one molecule of CnrX in the asymmetric unit.

가열장치를 구비한 부착형 X선 촬영대의 사용에 따른 화질 평가 (Evaluation of Image Quality according to the Use of Attachable X-ray Table Equipped with Heating Device)

  • 송종남;김응곤
    • 한국방사선학회논문지
    • /
    • 제9권4호
    • /
    • pp.219-225
    • /
    • 2015
  • 본 연구의 목적은 CR과 DR에서 가열장치를 구비한 부착형 탄소발열체 X선 촬영대의 사용에 따른 SNR과 CNR을 측정하여 부착 전과 부착 후의 화질을 평가하고자 한다. 알루미늄 계단 실험에서 CR은 부착 후에 SNR과 CNR이 증가하였지만 DR에서는 SNR과 CNR이 감소하였다. 인체모형팬텀 실험에서는 CR의 경우에 저에너지 저선량과 고에너지 고선량에서만 SNR과 CNR이 증가하였지만 다른 모든 조건에서는 SNR과 CNR이 감소하였다. 결론적으로 환자에게 온화한 느낌과 안전감을 제공하고 심적인 불안감을 해소하여 검사에 도움을 줄 수 있지만 임상적용에 있어서는 탄소발열체를 포함한 바닥필름과 보호필름의 두께와 재질을 고려하지 않으면 화질에 영향이 주기 때문에 향후 지속적인 연구가 필요하다고 사료된다.

Electrical instabilities in p-channel polysilicon TFTs: role of hot carrier and self-heating effects

  • Fortunato, G.;Gaucci, P.;Mariucci, L.;Pecora, A.;Valletta, A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권2호
    • /
    • pp.1065-1070
    • /
    • 2007
  • The effects of hot carriers and self-heating on the electrical stability of p-channel TFTs have been analysed combining experimental data and numerical simulations. While hot carrier effects were shown not to induce appreciable degradation, self-heating related instability was found to more seriously affect the device characteristics. New models have been developed to explain the reported results.

  • PDF

Analysis of transport properties of SLS polysilicon TFTs

  • Fortunato, G.;Bonfiglietti, A.;Valletta, A.;Mariucci, L.;Rapisarda, M.;Brotherton, S.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.513-518
    • /
    • 2006
  • An investigation of the transport properties of polysilicon TFTs, using sequential laterally solidified, SLS, material, is presented. This material has a location controlled distribution of grain boundaries, GBs, which makes it particularly useful for the analysis of their influence on the performance of polysilicon TFTs, and to address the issue of the role of spatially localised trapping states. The experimental results were analyzed by using numerical simulations, and the effective medium approximation was compared with a discrete grain model.

  • PDF

혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가 (Evaluation of Roadmap Image Quality by Parameter Change in Angiography)

  • 공창기;송종남;한재복
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.53-60
    • /
    • 2020
  • 이 연구의 목적은 Roadmap 영상에서 화질에 영향을 미치는 인자들을 알아보기 위한 것으로, 조영제의 희석률, Collimation Field, Flow Rate를 변화하여 연구를 하였다. 화질의 정량적인 평가를 위해, 아크릴를 이용하여 3mm 혈관모형의 Water Phantom을 자체 제작하였고, 자체 제작한 혈관모형의 Water Phantom으로 Roadmap 영상을 획득하고, SNR(Signal to Noise Ratio)과 CNR(Contrast to Noise Ratio)을 분석하였다. CM : N/S 희석률 변화에 대한 연구에서 CM : N/S 희석률을 (100%~10% : 100%)로 변화를 주었으며, 혈관모형 Water Phantom을 이용하여 촬영한 Roadmap 영상의 SNR과 CNR의 측정 결과 CM에 N/S 희석률이 높아질수록 SNR의 측정값이 점차적으로 낮아짐을 나타났고, CNR의 측정값도 점차적으로 낮아짐을 나타났다. 결론적으로 CM : N/S의 희석률이 높아질수록 SNR과 CNR 낮아짐을 확인하였고, CM : N/S의 희석률(100%~70 : 30%)에서 유의한 이미지를 얻을 수 있음을 확인하였다. Collimation Field 변화에 대한 연구에서 혈관모형 Water Phantom을 이용하여 Colimation Field를 혈관모형 중심으로 좌, 우 2 cm 간격으로 좁히면서 0 cm, 2 cm, 4 cm, 6 cm, 8 cm 10 cm, 12 cm으로 각각 변화를 주었으며, Roadmap을 촬영한 영상의 SNR과 CNR의 측정 결과는 Collimation Field를 혈관모형 중심으로 좁힐수록 SNR과 CNR의 측정값이 증가하는 것을 확인할 수 있었다. Flow rate 변화에 대한 연구에서 Autoinjector의 Volume을 15로 일정하게 하고, Flow Rate를 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 으로 각각 변화를 주었다. 혈관모형 Water Phantom을 이용하여 Roadmap 영상을 촬영한 이미지의 SNR과 CNR의 측정 결과 Flow Rate를 증가했을 때, SNR의 측정값이 점차적으로 감소하다가 Flow Rate 9~10에서 SNR의 측정값이 점차적 증가를 보였고, CNR의 측정값도 점차적으로 감소하다가 Flow Rate 9~10에서 CNR의 측정값이 점차적으로 증가를 보였다. 그러나 ROI Mean 값과 Background Mean 값으로 SNR과 CNR의 상관관계를 확인할 수 없었다. 상관관계를 확인하기 위해 Flow Rate 변화에 따른 Roadmap 연구는 향후 더 많은 연구로 확인해야 할 것으로 사료된다. 결론적으로 Roadmap 영상의 화질에 영향을 미치는 인자들을 알아보기 위해 조영제의 희석률, Collimation Field, Flow Rate 변화에 대한 연구에서 조영제에 N/S의 희석률이 증가할수록 SNR과 CNR이 낮아져 화질과 대조도가 낮아지는 것을 확인하였으며, Collimation Field를 좁힐수록 SNR과 CNR이 증가하여 화질과 대조도가 높아지는 것을 확인하였다. 그러나 Flow Rate 변화에 대한 연구에서는 상관관계를 확인할 수 없었다. 검사 및 시술을 할 때 신장의 영향을 최소화하기 위해 적절한 조영제 농도 선택과 대조도 향상 및 피폭 감소를 위한 적절한 Collimation Field를 사용하는 것이 유용할 것으로 판단된다.

Breast PET CT 영상 재구성 변화에 따른 대조도 대 잡음비와 신호 대 잡음비의 비교평가 (Evaluation and Comparison of Contrast to Noise Ratio and Signal to Noise Ratio According to Change of Reconstruction on Breast PET/CT)

  • 이재영;이을규;김기원;정회원;유광열;박훈희;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.79-85
    • /
    • 2017
  • 본 연구는 양전자 컴퓨터단층촬영(Positron Emission Computed Tomography; PET-CT) 유방암 영상에서 질환관심영역(Region of Interest; ROI)의 대조도 대 잡음비(Contrast to Noise Ratio; CNR)와 신호 대 잡음비(Signal to Noise Ratio; SNR)를 재구성 기법별로 측정 평가하여 통계적 분석을 하고자 하였다. 연구대상은 서울소재 대학병원에서 유방 양전자 컴퓨터단층촬영(Breast PET-CT)을 검사한 환자 100명이다. 측정방법은 ImageJ 프로그램을 사용하여 표본의 인구사회학적 특성, 영상 재구성 기법별 유방암의 SNR과 CNR의 평균값, 95% 신뢰구간 값, SNR과 CNR의 평균차이 값 등을 분석하였다. SPSS Statistics21 통계프로그램으로 ANOVA 분석을 하였으며 p<0.05에서 유의한 것으로 판단하였다. 영상 재구성 기법별 분석결과는 CNR과 SNR 모두 TrueX_TOF, Iterative, Iterative-TOF, FBP-TOF 순으로 높은 값을 나타냈다(p<0.05). CNR과 SNR수치로 영상 재구성 기법의 특징을 조합하여 PET/CT 검사의 정확성과 편의성을 제공할 것이라 사료된다.

Tagline 간격의 조절을 통한 SPAMM 영상에서의 Tagging 대조도 대 잡음비의 변화 (The Variation of Tagging Contrast-to-Noise Radio (CNR) of SPAMM Image by Modulation of Tagline Spacing)

  • 강원석;최병욱;최규옥;이상호;홍순일;정해조;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제13권4호
    • /
    • pp.224-228
    • /
    • 2002
  • MR영상에 Spatial Modulation of Magnetization (SPAMM)과 같은 lagging 기법을 이용하여 심근의 움직임을 분석하여 임상에 적용하려는 많은 노력들이 이루어지고 있다. Tagging 대조도는 자동 tagline 검출 알고리즘을 사용하는 경우, 그 정확도에 영향을 미칠 수 있으며, 이는 tagline들 간의 간격에 의해 영향을 받을 수 있다. 본 연구의 목적은 SPAMM 영상에서 tagline 간격과 tagging 대조도와의 관계를 생체내 연구를 통해 알아보고자 하였다. 두 명의 건강한 지원자를 대상으로 1.5T MR 시스템에서 SPAMM 기반의 ECG triggered MR 영상을 획득하였다. 영상을 획득할 때, 먼저 3.6 mm에서 9.6 mm 사이의 간격을 가지는 수평 tagging stripe pattern의 tagline을 가하였다. 심실의 영상은 심장주기가 진행되는 동안 field echo EPI (FE-EPI) 기법을 이용하여 심실 중간 부분에서 얻었다 각 영상에 대한 tagging contrast-to-noise ratio (CNR)는 IDL을 이용한 프로그램을 사용하여 측정하였다. 분석 결과는, 심근의 수축이 진행되는 동안, tagline 간격이 좁은 경우 CNR은 급격한 감소를 나타내었으나, 간격이 넓은 경우에서는 CNR 감소 현상이 보이지 않았다. 같은 심장 위상에서, CNR은 tagline 간격이 넓어짐에 따라 증가하는 경향을 보였다. 특히, 완전히 수축한 심장 위상에서는, CNR의 변화가 다른 위상일 때와 비교해서 그 증가율이 높음을 알 수 있었다. 이러한 양상은 움직임이 없는 다른 주변 조직에서는 관찰되지 않았다. 결론적으로, 본 연구에서는 lagging 대조도가 tagline 간격 및 심근의 수축에 영향을 받을 수 있음을 알 수 있었으며, 앞으로 정확한 심근 움직임 연구를 위한 기초 자료로 쓰여질 수 있을 것이라 생각된다.

  • PDF