Evaluation and Comparison of Contrast to Noise Ratio and Signal to Noise Ratio According to Change of Reconstruction on Breast PET/CT |
Lee, Jea-Young
(Department of Nuclear Medicine, Seoul National University Hospital)
Lee, Eul-Kyu (Department of Radiology, Inje Paik University Hospital Jeo-dong) Kim, Ki-Won (Department of Radiology, Kyung Hee University Hospital at Gang-dong) Jeong, Hoi-Woun (Department of Radiological Technology, The Baekseok Culture University) Lyu, Kwang-Yeul (Department of Radiological Technology, The Shingu University) Park, Hoon-Hee (Department of Radiological Technology, The Shingu University) Son, Jin-Hyun (Department of Radiological Technology, The Shingu University) Min, Jung-Whan (Department of Radiological Technology, The Shingu University) |
1 | Ortu no JE, Kontaxakis G, Rubio JL et al: Efficient Methodologies for System Matrix Modeling in Iterative Image Reconstruction for Rotating High-resolution PET. Physics in Medicine and Biology, 55(7), 1833-1861, 2010 DOI |
2 | Eu n-Joo Lee: Comparison between Mammography, Ultrasonography and -MIBI Scintimammography in the Diagnosis of Breast Cancer, Journal of the Korean Society of Radiology, 42(1), 191-197, 2000 DOI |
3 | Alessio A, Kinahan P: PET Image Reconstruction. Nuclear Medicine 2nd Edition, 1-22 |
4 | Il-Sang Moon, Hong Jae Lee, Jin Eui Kim et al: Quantitative Evaluation on Optimal Scan Time of PET/CT Studies Using TOF PET. The Korean Journal of Nuclear Medicine Technology, 16(1), 34-37, 2012 |
5 | Karp JS, Surti S, Daube witherspoon ME et al: Benefit of Time of Flight in PET: Experimental and Clinical Results. Journal of Nuclear Medicine, 49(3), 462-532, 2008 DOI |
6 | Se-Moon Oh, Kye-Hwan Kim, Seung-Jeong Kim et al: The Evaluation of True X Reconstruction Method In Low Dose. The Korean Journal of Nuclear Medicine Technology, 15(2), 83-87, 2011 |
7 | Dong-Seok Kim, Hee-Jae Yoo, Dong-Oh Sim et al: The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number. Journal of Nuclear Medicine, 15(1), 17-24, 2011 |
8 | Ha-Gyun Kim, Soo-Mee Kim, Jae-Ryong Woo et al: The Evaluation of Images with Various Filters in I-131 SPECT/CT. Journal of Nuclear Medicine, 18(1), 62-68, 2014 |
9 | Jung-Whan Min, Ki-Won Kim, Kwang-Yuel Ryu et al: Comparison Study on CNR and SNR of Thoracic Spine Lateral Radiography. Journal of Radiological Science and Technology, 36(4), 280-273, 2013 |
10 | Sun-Myung Park, Hyuk Lee, Gun-Chul Hong et al: Evalaution of the Image Quality According to the Pre-set Method in PET/CT Image. Journal of Nuclear Medicine, 15(2), 41-46, 2011 |
11 | Jung-Whan Min, Hoi-Woun Jeong, Ki-Won Kim et al: Evaluation of quantitative on T- spine exhalation technique and T-spine breathing technique of natural breathing. Journal of the Korea Academia-Industrial Cooperation Society, 14(9), 4429-4436, 2013 DOI |
12 | Eu l-Kyu Lee, Kwan-Woo Choi, Jung-Whan Min: et al: Statistical Approch of Measurement of Signal to Noise R atio i n According to C hange Pu lse Sequence on Brain MRI Meningioma and Cyst Images. Journal of Radiological Science and Technology, 39(3), 345-352, 2016 DOI |