• 제목/요약/키워드: CAD/CAM dental

Search Result 419, Processing Time 0.038 seconds

A study on Common Errors in Digital Impressions: (An Example of CEREC$^{(R)}$ AC) (디지털 인상 채득 시 흔히 발생하는 오류에 관한 연구 - CEREC$^{(R)}$ AC의 사례 중심으로 -)

  • Kim, Jae-Hong;Kim, Ji-Hwan;Kim, Hae-Young
    • Journal of Technologic Dentistry
    • /
    • v.33 no.3
    • /
    • pp.211-218
    • /
    • 2011
  • Purpose: The purpose of the study was a quantitative evaluation of common errors in digital impression procedure using CEREC$^{(R)}$ AC system. Methods: Two-hundreds digital impression data comprising 174 inlays, 26 onlays by CEREC$^{(R)}$ AC in-office CAD/CAM system were obtained from a dental clinic. One evaluator assessed errors of the digital impression data and divided into five categories of errors: inappropriate scanner positioning (ISP), improper handling with a scanner (IHS), irregular powder arrangement (IPA), improper cavity preparation (ICP), and insufficient scanned data (ISD). Results: The most common errors were IPA(21%), and ISP and ISD were followed by 17% respectively. IHS was found in 14.5% of all digital impression data. ICP comprising only 6.5% was the rarest. Conclusion: Most errors were due to inaccurate manipulation with an intraoral scanner or improper cavity preparation for scanning. A deliberate manipulation to prevent common errors mentioned may deliver an optimal result in the digital impression procedure.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

Full-mouth rehabilitation with CAD/CAM monolithic zirconia in dentinogenesis imperfecta: a case report (상아질 형성 부전증 환자에서 CAD/CAM 단일 구조 지르코니아를 이용한 완전구강회복 증례)

  • Kim, Min-Kyoo;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung;Ha, Seung-Ryong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Dentinogenesis Imperfecta, with a high incidence rate of 1 : 6 - 8000, is inherited by autosomal dominant genetic transmission. This dental disorder causes discoloration of the teeth and the enamel and dentin show hypoplastic or hypocalcified defects which lead to frequent fractures and rapid attrition. Therefore, timely treatment is necessary for the preservation of the remaining teeth. In this particular case, a 19-year-old patient suffering from Type 1 dentinogenesis imperfecta showed signs of brownish hued teeth with multiple fractures, a loss of vertical dimension, excessive interdental space in the maxillary anterior teeth, and a lack of 5 posterior teeth. To improve the esthetic appearance of the anterior teeth, the vertical dimension was increased. Resin caps were used to alleviate the difficulty of taking an impression of multiple teeth at once. Monolithic zirconia materials used in this case showed high fracture strength and the ability to mask the discoloration of the teeth and therefore, functionally and esthetically favorable results were achieved.

Digital intraoral impression for immediate provisional restoration of maxillary single implant: A case report (구강 내 디지털 인상채득을 통한 상악 전치부 임플란트 즉시 임시 보철 수복 증례)

  • Chang, Yun-Jeong;Kim, Hong-Jun;Song, Mi-Kyoung;Moon, Ji-Eun;Lee, Hal-La;Park, Chan-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.234-243
    • /
    • 2015
  • Developing of digital technique, it is possible to fabricate implant prostheses for edentulous area using intraoral 3-dimentional information throughout implant diagnosis and treatment process. It is being changed that from the method using CAD/CAM, producing prostheses by model scanning after conventional impression and model processing, to the method of fabricating implant provisional restorations and customized abutments by digital impression after connecting digital impression copings (scanbody) and implant fixtures without models. But, this digital method has not been actively used for implant prostheses not yet. Specially, it is short of intraoral digital impression cases for immediate provisional restorations of the maxillary anterior implants. The gingival contour impression of maxillary anterior area is very important for esthetic restorations. Accordingly, in this case report, the using a digital impression coping (scanbody) and digital impression by CEREC Omnicam (Sirona, Bensheim, Germany) or Trios (3shape, Copenhagen, Denmark) were introduced for immediate provisional restorations in 3 cases needed a single implant restoration in maxillary anterior area. The clinical results were satisfactory on the convenience and accuracy of digital impression technique and the good esthetics of final restorations.

The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients ($Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구)

  • Song, Young-Gyun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.470-478
    • /
    • 2008
  • Statement of problem: Use of all-ceramic prostheses fabricated with CAD/CAM systems is increasing in the dentistry. Marginal fidelity in production of all-ceramic restoration has important clinical implications and is a key consideration issue in CAD/CAM production as well. Purpose: The objective of this study was to analyse marginal fidelities of $Procera^{(R)}$ Allceram Crown. Material and methods: On 56 patients treated with $Procera^{(R)}$ system Allceram Crown at Dankook Dental Hospital, marginal discrepancies of 101 abutments were measured by stereomicroscope at coping and final restoration stages. Paired t-test and one-way analysis of variance on marginal discrepancy data were conducted to determine the presence of significant differences between measurement and measuring point stages. Results: Marginal discrepancies of final restoration ($45.82{\pm}30.84\;{\mu}m$) were lower than alumina coping ($53.84{\pm}38.83\;{\mu}m$). Furthermore, the differences were found to be statistically significant at 95% confidence level. Anterior marginal discrepancies were lower than posterior marginal discrepancies, but they were not statistically significant. Lingual marginal discrepancies were higher than other measurement sites, and the differences were found to be statistically significant at 95% confidence level. Conclusion: Within the conditions of this study, marginal fidelities of $Procera^{(R)}$ Allceram Crown were acceptable, and after porcelain build-up, marginal fitness improved over alumina coping. More careful scanning is needed for better results.

Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay (CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구)

  • Baek, Chul-Woo;Park, Cheol-Woo;Park, Jun-Sub;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.20-26
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. Materials and methods: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem$^{(R)}$, Biscem$^{(R)}$, and Variolink II$^{(R)}$) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the $5-55^{\circ}C$, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline $37^{\circ}C$, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. Results: Unicem$^{(R)}$ group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem$^{(R)}$ group and ValiolinkII$^{(R)}$ group were significantly influenced by thermocycling, whereas Biscem$^{(R)}$ group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem$^{(R)}$ group and Valiolink II$^{(R)}$ group with thermocycling(P<.05). Conclusion: It has been shown to be clinically effective when the self-adhesive resin cements Unicem$^{(R)}$ and Biscem$^{(R)}$ were used instead of the etch-and-rinse resin cement Valiolink II$^{(R)}$ during the bonding of CAD/CAM ceramic inlay restorations with teeth.

Planning and Evaluation of Orthognathic surgery using CBCT imaging (임상가를 위한 특집 3 - CBCT를 이용한 악교정수술 계획 수립 및 평가)

  • Choi, Jeong-Ho
    • The Journal of the Korean dental association
    • /
    • v.52 no.1
    • /
    • pp.27-36
    • /
    • 2014
  • The introduction of cone-beam computed tomography(CBCT) and computer software in dentistry has allowed orthodontists and maxillofacial surgeons to provide more accurate diagnosis and treatment. In this article, a facial asymmetry patient who had orthodontic treatment combined with orthognathic surgery using CBCT imaging is introduced and the way how CBCT imaging could be applied in clinical orthodontics and orthognathic surgery is explained. Also, evaluation of treatment outcomes using CBCT is suggested. More accurate, predictable and efficient surgical orthodontic planning and treatment are expected in the near future through cutting edge medical imaging including CBCT and CAD/CAM technologies.

White & Pink Esthetic for Clinical Restoration (심미보철 제작에 필요한 White & Pink Esthetic)

  • Yoo, Ha-Seong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.95-115
    • /
    • 2019
  • To be successful in aesthetic prosthetic treatment, the crown part aesthetic (White Esthetic) and the tissue part aesthetic (Pink Esthetic) must be well controlled. Clinically, white esthetics are the area of dental technicians and pink esthetics are the area of dentists, but a deeper understanding of counterparts can produce more successful results. In this paper, I will briefly describe this process.

A Preliminary Study on the Fitness of Adjustable Dental Impression Trays (가변형 치과 인상용 트레이의 적합도에 관한 예비연구)

  • Kim, Min-Jeong;Oh, Sang-Chun;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.83-93
    • /
    • 2005
  • This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

Effect of zirconia ceramic sintering condition on the precision of fit in dental restorations (지르코니아 세라믹 소결조건이 치과보철물의 적합도에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.121-128
    • /
    • 2020
  • Purpose: This study aimed to investigate the effects of the sintering conditions of zirconia core on the adaptability. Methods: Ten specimens of each of commercial brand of zirconia(Razor 1100, U&C international, Seoul, Korea) were made and sintered under three different conditions. Specimens were divided into three subgroup(n=10) and sintered with various total time(1hr, 3hr, 9hr) at the maximum temperature(1500℃). The digitized data was superimposed with 3D inspection software to quantitatively obtain the adaptation of a zirconia core, and visual differences were confirmed with a color map. The root mean square(RMS) values of group were statistically analyzed with one-way ANOVA(α=0.05). Results: The overall adaptation of the zirconia cores were as follows; ss-1hr: 36.18±5.2㎛, ss-3hr: 39.55±3.9㎛, cs-9hr: 46.62±4.3㎛. They were statistically significant differences between groups for adaptation(p<0.05). Conclusion: Based on the results of this study, it could be considered that sintering condition of 1500℃ and 1~3 hour is recommended for the better marginal and internal fit. Speed sintering can be widely utilized to fabricate zirconia prothesis as the properties of those almost are to dentistry uses.