• Title/Summary/Keyword: C2 architecture

Search Result 1,121, Processing Time 0.037 seconds

Physico-chemical effects of cerium oxide on catalytic activity of CeO2-TiO2 prepared by sol-gel method for NH3-SCR (CeO2가 졸겔법으로 합성한 CeO2-TiO2계 SCR용 촉매의 활성에 미치는 물리화학적 영향)

  • Kim, Buyoung;Shin, Byeongkil;Lee, Heesoo;Chun, Ho Hwan
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.6
    • /
    • pp.320-324
    • /
    • 2013
  • The effects of $CeO_2$ on catalytic activity of $CeO_2-TiO_2$ for the selective catalytic reduction (SCR) of $NO_x$ were investigated in terms of structural, morphological, and physico-chemical analyseis. $CeO_2-TiO_2$ catalysts were synthesized with three different additions, 10, 20, and 30 wt% of $CeO_2$, by the sol-gel method. The XRD peaks of all specimens were assigned to a $TiO_2$ phase (anatase) and the peaks became broader with the addition of $CeO_2$ because it was dispersed as an amorphous phase on the surface of $TiO_2$ particles. The specific surface area of $TiO_2$ increased with the addition of $CeO_2$ from $60.6306m^2/g$ to $116.2791m^2/g$ due to suppression of $TiO_2$ grain growth by $CeO_2$. The 30 wt% $CeO_2-TiO_2$ catalyst, having the strongest catalytic acid sites ($Br{\Phi}nsted$ and Lewis), showed the highest $NO_x$ conversion efficiency of 98 % at $300^{\circ}C$ among the specimens. It was considered that $CeO_2$ contributes to the improvement of the $NO_x$ conversion of $CeO_2-TiO_2$ catalyst by increasing specific surface area and catalytic acid sites.

Characteristics of Soil Parameter for Lade's Single Work-Hardening Constitutive Model with Relative Density of Bottom ash (석탄회의 상대밀도에 따른 Lade 단일항복면 구성모델의 토질매개변수 특성)

  • Kim, Chan-Kee;Lee, Jong-Cheon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.4
    • /
    • pp.87-98
    • /
    • 2013
  • This study was performed a series of the isotropic compression-expansion tests and the drained triaxial tests with various the relative densities 40%, 60%, 80% and 95% for bottom ash. Using the tests results the characteristic of the parameters of Lade's single hardening constitutive model were investigated. The soil parameters Kur and n representing elastic behavior are not much affected by the change of the relative density. The other parameters such as failure criterion(m, ${\eta}_1$), hardening function(c, p) and plastic potential(${\psi}_2$, ${\mu}$) are in a positive linear relationship with the relative density. Since the soil parameters h and ${\alpha}$ representing yield function do not change much to the change of relative density and also closely related to failure criterion, they can be replaced by failure criterion ${\eta}_1$. We also observed that predicted values from the Lade's single hardening constitutive model were well consistent with the observed data.

Design of Green Community Rediscovery Center with Community Gardens and Social Integration Functions (공동체정원과 사회통합기능이 있는 Green Community Rediscovery Center의 설계)

  • Lee, Eung-Jik;Lee, Hyung-Sook;Yoon, Eun-Ju;Ekpeghere, Kalu I.;Koh, Sung-Cheol
    • KIEAE Journal
    • /
    • v.11 no.4
    • /
    • pp.29-36
    • /
    • 2011
  • The aim of this study was to study the functions and roles of Green Community Rediscovery Center (GCRC) in terms of community integration, to design GCRC with various types of green roofs, and to investigate the possibility of applying a renewable energy system (e.g., PV) to the building greenery systems. The four major functional modules for GCRC were suggested: implementation of ecopark and community gardens with environmental education programs, implementation of green housing model with education programs, Discover Science Center, and implementation of green business model with education programs. Three major functions of the center are also presented in terms of design: 1) functions of community gardens; 2) establishment of a green business model, community composting system and an urban farming system; and 3) roles of community gardens in social interactions within GCRC. GCRC provides residents with the opportunities of community gardens, urban farming based on a successful recycling system, as well as a green business model and environmental education programs near their homes. The air temperature of the green roof (utilizing Sedum sarmentosum as a cover plant) was approximately $3^{\circ}C$ lower than that of the non-green roof, indicating a potential efficiency increase in PV systems for GCRC. It was concluded that the GCRC suggested would enhance the neighborhood satisfaction, improve the quality of life and contribute to social integration and community regeneration.

A Methodology for the Development of NCO Effectiveness Analysis Model based on the Reference Model (참조모델기반 NCO 효과분석모델 개발방법)

  • Lim, Nam-Kyu;Lee, Tae-Gong;Son, Hyun-Sik;Park, Ji-Hyeon;Kim, Jae-Won
    • Journal of the military operations research society of Korea
    • /
    • v.36 no.3
    • /
    • pp.95-111
    • /
    • 2010
  • The NCO effectiveness analysis related elements and their relationship are more complicated than the PCW. However, Effectiveness analysis models provide single effectiveness element centric effective analysis method so far. Therefore, A model to provide unified view and common language about NCO effectiveness is required. EA use reference model as a common language to control complexity and change. The objective of this study is presenting a methodology to develop NCO effectiveness analysis model based on reference model and implementation model concept. To do this, First, the concept of EA based reference and implementation model is studied, Second, we study related effectiveness analysis method and model component and their relationship identification methodology, third, we propose methodology to develop NCO effectiveness analysis model. Finally, we prove the effectiveness of the methodology using case study.

Development of an Ex Vivo Model for the Study of Cerebrovascular Function Utilizing Isolated Mouse Olfactory Artery

  • Lee, Hyung-Jin;Dietrich, Hans H.;Han, Byung Hee;Zipfel, Gregory J.
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • Objective : Cerebral vessels, such as intracerebral perforating arterioles isolated from rat brain, have been widely used as an ex vivo model to study the cerebrovascular function associated with cerebrovascular disorders and the therapeutic effects of various pharmacological agents. These perforating arterioles, however, have demonstrated differences in the vascular architecture and reactivity compared with a larger leptomeningeal artery which has been commonly implicated in cerebrovascular disease. In this study, therefore, we developed the method for studying cerebrovascular function utilizing the olfactory artery isolated from the mouse brain. Methods : The olfactory artery (OA) was isolated from the C57/BL6 wild-type mouse brain. After removing connective tissues, one side of the isolated vessel segment (approximately $-500{\mu}m$ in length) was cannulated and the opposite end of the vessel was completely sealed while being viewed with an inverted microscope. After verifying the absence of pressure leakage, we examined the vascular reactivity to various vasoactive agents under the fixed intravascular pressure (60 mm Hg). Results : We found that the isolated mouse OAs were able to constrict in response to vasoconstrictors, including KCl, phenylephrine, endothelin-1, and prostaglandin $PGH_2$. Moreover, this isolated vessel demonstrated vasodilation in a dose-dependent manner when vasodilatory agents, acetylcholine and bradykinin, were applied. Conclusion : Our findings suggest that the isolated olfactory artery would provide as a useful ex vivo model to study the molecular and cellular mechanisms of vascular function underlying cerebrovascular disorders and the direct effects of such disease-modifying pathways on cerebrovascular function utilizing pharmacological agents and genetically modified mouse models.

Evaluation of Cooling Energy Saving through Applying Aisle Partition System on a Data Center Server Room (파티션 시스템 적용을 통한 기존 데이터센터 서버실의 냉방 에너지 절감 성능평가)

  • Park, Jong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.726-733
    • /
    • 2016
  • In this study, a computer simulation of the three types of air distribution systems, open type system, aisle partition system and aisle containment system, to evaluate the applicability of the aisle partition system on a data center server room. The variables of the simulation were the height and location of the partition fixed on the top server rack. The energy efficiency of the air distribution systems were confirmed to be excellent in the order of the aisle containment system, aisle partition system, and open type system. In the cold aisle partition system, the height of the partition that can be effective in saving cooling energy by obstructing sufficient air recirculation was found to be more than 0.9m. In the hot aisle partition system, the height of the partition was found to be more than 0.8m.

A Complex Bandpass Sampling Method for Downconversion of Multiple Bandpass Signals (다중 대역통과 신호의 하향변환을 위한 Complex Bandpass Sampling 기법)

  • Bae, Jung-Hwa;Ha, Won;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.9C
    • /
    • pp.913-921
    • /
    • 2005
  • A complex bandpass sampling technique can provide a more flexible architecture for designing a software- defined radio(SDR) system, because it has several advantageous features of larger sampling range and lower minimum sampling frequency than a real bandpass sampling method. In spite of the potential advantages of the complex bandpass sampling, solid investigation for the direct downconversion of multiple signals by the complex sampling theory has not been reported yet. Thus, we propose in this paper a novel scheme for the downconversion of multiple signals using the complex bandpass sampling, and develop the formulae related to the complex bandpass sampling for practical usage, such as the valid sampling range, the intermediate frequency (If), and the minimum sampling frequency of the downconversion of multiple RE signals. Such derived formulae are verified from simulations.

Analysis of Soil Thermal Conductivities, Borehole Thermal Resistances and Initial Soil Temperature with In-Situ Testing in South Korea (현지 측정에 의한 남한지역의 지중유효열전도도, 보어홀 전열저항 및 초기온도 분석)

  • Ro, Jeong-Geun;Yon, Kwangseok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.68-74
    • /
    • 2012
  • Investigation of the effective soil thermal conductivity($k$) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. The first step is measured for initial soil temperature. This is done by supplying a only pump power into a borehole heat exchanger. They need to supply into water unload heat power more than 30 minutes. In this study, the initial soil temperature was found to analysis $14.1{\sim}16.0^{\circ}C$,the ratio was 68.7% represented. In this case of $k$, was 2.1~3.0 $W/m{\cdot}k$, $R_b$ was 0.11~0.20 $m{\cdot}K/W$. In this work, it is also shown that the distribution of a soil thermal conductivity and borehole thermal resistance were on the influence of initial soil temperature. And soil thermal conductivity was related with factors of equation by linear least square method, borehole thermal resistance was on the influence of composite factors.

AE32000B: a Fully Synthesizable 32-Bit Embedded Microprocessor Core

  • Kim, Hyun-Gyu;Jung, Dae-Young;Jung, Hyun-Sup;Choi, Young-Min;Han, Jung-Su;Min, Byung-Gueon;Oh, Hyeong-Cheol
    • ETRI Journal
    • /
    • v.25 no.5
    • /
    • pp.337-344
    • /
    • 2003
  • In this paper, we introduce a fully synthesizable 32-bit embedded microprocessor core called the AE32000B. The AE32000B core is based on the extendable instruction set computer architecture, so it has high code density and a low memory access rate. In order to improve the performance of the core, we developed and adopted various design options, including the load extension register instruction (LERI) folding unit, a high performance multiply and accumulate (MAC) unit, various DSP units, and an efficient coprocessor interface. The instructions per cycle count of the Dhrystone 2.1 benchmark for the designed core is about 0.86. We verified the synthesizability and the area and time performances of our design using two CMOS standard cell libraries: a 0.35-${\mu}m$ library and a 0.18-${\mu}m$ library. With the 0.35-${\mu}m$ library, the core can be synthesized with about 47,000 gates and operate at 70 MHz or higher, while it can be synthesized with about 53,000 gates and operate at 120 MHz or higher with the 0.18-${\mu}m$ library.

  • PDF

The Sensitivity Analysis of Thermal Expansion Breakage of Multi-layer Glazing in Building Envelope (건물 외피에 적용된 복층창의 열팽창 파손에 대한 민감도 분석 연구)

  • Yoon, Jong-Ho;Kim, Seung-Chul;Im, Kyung-Up;Oh, Myeong-Hwan
    • KIEAE Journal
    • /
    • v.14 no.6
    • /
    • pp.93-97
    • /
    • 2014
  • Curtain wall system of office buildings has recently become very common in Korea. As the multi-layer curtain glazing is exposed to outdoor environment, it is very subjected to direct environmental impact. Consequently, breakage and cracks of glazing due to heat expansion is frequently observed. This study explores various causes and aspects for destruction of multi-layer glazing. A sensitivity analysis was performed on the basis that thermal changes causes damage to the multi-layer glazing. Air temperature in air cavity within the multi-layer glazing was examined to find its effect on multi-layer glazing breakage. Analysis showed high deflection to depth ratio of 1:1.8 and that higher the aspect ratio, smaller is the deflection. Allowable pressure showed that the weakest value is for aspect ratio of 1:2.9. Sensitivity analysis by the area of the glazing showed that as area of glazing becomes higher, allowable pressure and deflection-depth ratio becomes smaller. For allowable pressure and allowable deflection-depth within air cavity, the glazing breakage occurred at least $107^{\circ}C$. The results from glazing breakage by thermal factor shows that it is hard to break the glazing with only an increase in air cavity temperature in multi-layer glazing applied in buildings.