Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains (연직드레인 공법에 의한 연약지반의 압밀거동)

  • 이달원;강예묵
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.376-381
    • /
    • 1998
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system 1. The relation of measurement settlement( $S_{m}$) versus design settlement( $S_{t}$) and measurement consolidation ratio( $U_{m}$) versus design consolidation ratio( $U_{t}$) were shown $S_{m}$=(1.0~l.1) $S_{t}$, $U_{m}$=(1.13~l.17) $U_{t}$, at 1.0m drain spacing and $S_{m}$=(0.7~0.8) $S_{t}$, $U_{m}$=(0.92~0.99) $U_{t}$ at 1.5m drain spacing, respectively. 2. The relation of field compression index( $C_{cfield}$) and virgin compression index( $V_{cclab}$) was shown $C_{cfield}$=(1.0~1.2) $V_{cclab}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio( $C_{h}$/ $C_{v}$) were $C_{h}$=(2.4 ~ 3.0) $C_{v}$. $C_{h}$=(3.5 ~ 4.3) $C_{v}$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacingngasing of drain spacingng spacingng

  • PDF

Fracture Behavior of Aged 15Cr-5Ni Stainless Steel (15Cr-5Ni 스테인리스강의 파괴 거동)

  • Chu, M.C.;Saito, K.;Tubota, M.;Ando, K.
    • Journal of Power System Engineering
    • /
    • v.6 no.1
    • /
    • pp.61-67
    • /
    • 2002
  • 15Cr-5Ni 석출강화 스테인리스강 3종류의 피로균열 발생과 성장 특성 및 파괴인성에 대하여 노치함수로서 연구하였다. 3종류강의 열처리 조건은 $482\;^{\circ}C,\;579\;^{\circ}C$$621\;^{\circ}C$이다. $621\;^{\circ}C$에서 4시간동안 열처리한 시험편 C는 약 $280\;MPa\;\sqrt{m}$의 가장 높은 파괴인성을 보였으며, 3종류에서 피로균열 성장이 가장 늦었다. $482\;^{\circ}C$에서 1시간 열처리한 시험편 A에서, 피로균열발생한계, ${\Delta}k{\rho}$, 는 노치반경0.3 mm에서 약 $280\;MPa\;\sqrt{m}$의 가장 높은 값을 보였다. 시험편 A는 시험편 B와 C보다 피로균열 성장이 빨랐지만, 피로균열 발생이 늦었다. 예 하중에 의한 노치선단의 압축잔류응력은 노치 시험편의 피로강도 향상에 유용한 방법이었다.

  • PDF

Dyeing Fastness of Colouring Matter Extracted in Butterbur Leaf (더위 잎 색소의 염색견뢰도)

  • Park, Young-Deuk
    • Fashion & Textile Research Journal
    • /
    • v.4 no.4
    • /
    • pp.394-398
    • /
    • 2002
  • The purse of this study was to invesigate the dyeing fastness on extract of bufferbur leaf princeps. The experimental items were divided into the mordant treatment, component of fabric and kind of mordants. The experimental study was done by laundering, abrasion (dry/wet), perspiration (acid/alkali), light, iron fastness test and color difference by C.C.M system. The summerized finding resulted from experiments and investigation are suggested as follows : In the C.C.M test on mordanting method and kind of fabric, color difference of silk was three times higher than cotton. The silk fabric was the highest in simultaneous mordant treatment but cotton fabric was the highest in none mordant. In color difference analysis on 6 mordants, that of silk and cotton was significantly improved when mordants was treatmented. Especially color difference of Fe and Cu mordanting treatment was higher than Cr, Sn, Al and none. In dyeing fastness on mordants laundering, perspiration, abrasion and iron fastness showed 4-5 grade but light-fastness showed 1-3 grade.

A Study on VV&A Application Method for Credibility Improvement of The DM&S for C4I Test and Evaluation (C4I체계 시험평가 국방M&S 신뢰도 향상을 위한 VV&A 적용방안 연구)

  • Kim, Kyung-Hee;Kang, Seok-Joong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1080-1090
    • /
    • 2010
  • A study for improvement of credibility on test & evaluation result of interoperability in battle management information system which focused in C4I systems is very essential in rapid change of battle field environment. Realization of effective operation process with integration of developed IT also core factor for reducing of operational response time such as information gathering from sensor to shooter, time for commander's decision making. Therefore, by required to meet of high technical T&E, meet of complex software's user requirement, long-term system development period, system integration ability's request by various linkage of systems, it is high a M&S dependency to optimal performance, interpoerability's guarantee. Especially credibility on test & evaluation using M&S is very important. This paper will propse a VV&A applied methods using other VV&A case to improve credibility of M&S on test & evaluation.

INDUCTIVE LIMIT IN THE CATEGORY OF C* -TERNARY RINGS

  • Arpit, Kansal;Ajay, Kumar;Vandana, Rajpal
    • Bulletin of the Korean Mathematical Society
    • /
    • v.60 no.1
    • /
    • pp.137-148
    • /
    • 2023
  • We show the existence of inductive limit in the category of C*-ternary rings. It is proved that the inductive limit of C*-ternary rings commutes with the functor 𝓐 in the sense that if (Mn, ϕn) is an inductive system of C*-ternary rings, then $\lim_{\rightarrow}$ 𝓐(Mn) = 𝓐$(\lim_{\rightarrow}\;M_{n})$. Some local properties (such as nuclearity, exactness and simplicity) of inductive limit of C*-ternary rings have been investigated. Finally we obtain $\lim_{\rightarrow}\;M_{n}^{**}$ = $(\lim_{\rightarrow}\;M_{n})^{**}$.

Rapid and Efficient Molecular Cloning of Rat Liver Full-length LDH A-cDNA (효율높은 cloning system을 통한 Rat Liver 전장 낙산탈수소효소 A-cDNA의 제조 및 분리동정)

  • 노옥경;배석철;이승기
    • YAKHAK HOEJI
    • /
    • v.31 no.2
    • /
    • pp.116-125
    • /
    • 1987
  • It is still difficult and time consuming to obtain cDNA sequences that contain the entire nucleotide sequence of the corresponding mRNA. A rapid and high efficient cloning method to obtain full-length cDNA segments is thus developed. The cloning procedure described here consists of the construction of oligo(dT)-tailed vector primer using pWR34 plasmid, polyadenylation of mRNA-cDNA heteroduplex using terminal deoxytransferase, and replacement of MRNA strand with DNA by RNase H and DNA polymerase I. The restriction endonuclease analysis shows that the size of inserted-cDNA is in the range of 1.5~4.0 kb long suggesting that most of cloned cDNA are full-length or nearly full-length cDNA. The plasmid-DNA recombinants obtained were 4$\times$$10^5$~$10^{6}$ per $\mu\textrm{g}$ of rat liver poly (A$^+$)mRNA, which is 4 to 10 fold higher cloning efficiency in comparison to the presently used methods for full-length cDNA cloning. The results indicate that the described cloning system is much simpler, less time consuming, and very efficient cloning method to construct a cDNA library.

  • PDF

A study on the Method of Evaluating Analysis for Computer Integrated Manufacturing System (ERP시스템과의 통합을 위한 CIM시스템의 평가 분석방법에 관한 연구)

  • 김제홍
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.1
    • /
    • pp.147-153
    • /
    • 2002
  • A major problem in the adoption of advanced manufacturing systems such as C.I.M. (Computer Integrated Manufacturing) is the prerequisite economic justification Process because of high investment needed for the acquisition and installation of C.I.M. While some of the benefits expected are readily qualifiable, others are very difficult or even impossible, using conventional method. Thus the investment in C.I.M. should be considered as a strategic decision rather than a tactical decision which concerns with only financial implications. In this Paper we review papers on major justification techniques developed during the last decade and identify the benefits of C.I.M. and describe the considerations in the justification of C.I.M. Also we deal with the current and future research directions in justifying C.I.M.

  • PDF

A study on polycrystalline 3C-SiC etching with magnetron applied reactive ion etching for M/NEMS applications (마그네트론 RIE을 이용한 M/NEMS용 다결정 3C-SiC 식각 연구)

  • Chung, Gwiy-Sang;Ohn, Chang-Min;Nam, Chang-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.197-201
    • /
    • 2007
  • The magnetron reactive ion etching (RIE) characteristics of polycrystalline (poly) 3C-SiC grown on $SiO_{2}$/Si substrate by APCVD were investigated. Poly 3C-SiC was etched by $CHF_{3}$ gas, which can form a polymer as a function of side wall protective layers, with additive $O_{2}$ and Ar gases. Especially, it was performed in magnetron RIE, which can etch SiC at a lower ion energy than a commercial RIE system. Stable etching was achieved at 70 W and the poly 3C-SiC was undamaged. The etch rate could be controlled from $20\;{\AA}/min$ to $400\;{\AA}/min$ by the manipulation of gas flow rates, chamber pressure, RF power, and electrode gap. The best vertical structure was improved by the addition of 40 % $O_{2}$ and 16 % Ar with the $CHF_{3}$ reactive gas. Therefore, poly 3C-SiC etched by magnetron RIE can expect to be applied to M/NEMS applications.

Fog Nozzle-Greenhouse Cooling System Analysis (포그노즐을 이용한 온실냉방시스템 분석)

  • 김영중;유영선;윤진하;오권영;김승희
    • Journal of Bio-Environment Control
    • /
    • v.6 no.1
    • /
    • pp.48-54
    • /
    • 1997
  • Among the various vegetables eggplant and gourd family can stand against high temperature environmental condition, about 35$^{\circ}C$. However, most of greenhouse farmers are giving up crop cultivation during hot summer season due to extreme temperature, 4$0^{\circ}C$ or above, condition of greenhouse interior. To improve this inferior crop growth condition, for nozzle system was installed in the pet greenhouse and the effect of fog system was investigated in order to determine fog water amount and the required fog nozzle numbers according to house volumes. MEE fog nozzle was selected for this Investigation which can produce water particle size of 27${\mu}{\textrm}{m}$ with water amount of 100$m\ell$ at pumping pressure of 70kg/$\textrm{cm}^2$. House cooling test was conducted in the pet greenhouse with one minute fogging and one minute air ventilation without stopping. It maintained 32$^{\circ}C$ at the house interior when the atmosphere and the house temperature were 35 and 4$0^{\circ}C$, respectively. And, an experimental equation was developed through calculating the changes of relative humidity and temperature with psychrometric equation which revealed the moisture transfer pattern between the house air and fog system. It showed that the required water fogging amounts to reduce 1$0^{\circ}C$, 40 to 3$0^{\circ}C$, needs 80.7$\ell$ for 1-2W(8,350㎥) and 99.9$\ell$ for 3-2G-3S(10,330㎥) type greenhouse with particle size of 27${\mu}{\textrm}{m}$.

  • PDF