• Title/Summary/Keyword: C-scan

검색결과 781건 처리시간 0.032초

MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가 (Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber)

  • 이창래;김희중;전성수;조효민;남소라;정지영;이영진;이승재;동경래
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.49-55
    • /
    • 2008
  • 본 연구는 MDCT에서 선량을 측정하는데 사용되는 ionization chamber의 calibration 전과 후의 calibration factor에 따른 선량과 촬영실의 온도, 기압의 보정(correction factor) 적용 유무에 따른 $CTDI_w$를 비교 분석하는데 있다. 2007년 3월 21일에 교정된 Model 2026C electormeter (RADICAL 2026C, USA)를 이용한 MDCT (GE light speed plus 4 slice, USA)와 head and body CT dosimetry phantom을 사용하여 측정된 값을 비교 분석하였다. 결과는 calibration factor와 주변 온도, 압력의 correction factor를 보정 해 준 $CTDI_w$ 값이 보정을 하지 않고 계산된 값보다 $0.479{\sim}3.162mGy$의 범위만큼 더 많은 선량 값이 계산되었고 실제 병원에서 사용하는 복부 일반 CT (abdomen routine CT) 조건에서의 환자선량을 측정한 결과 factor적용 전과 후의 유효선량 차는 최고 0.7 mSv의 차이가 남을 확인 할 수 있었다. 이러한 결과는 ionization chamber의 calibration과 촬영실 주변 온도와 압력이 환자선량의 측정과 계산에 중요한 요소임을 알 수 있다. 따라서 정확한 환자 선량 측정을 위해서는 촬영실 주변 온도와 압력뿐만 아니라 습도 및 recombination factor, x-ray beam quality 특성, 촬영조건(exposure conditions), 측정부위(scan region) 등에 대한 보정 factor들의 정확한 정보를 알아야 한다.

  • PDF

Keyhole Imaging기법을 적용한 위상대조도 자기공명 혈관조영기법 (Keyhole Imaging Combined Phase Contrast MR Angiography Technique)

  • 이동훈;홍철표;한봉수;이만우
    • 대한의용생체공학회:의공학회지
    • /
    • 제33권2호
    • /
    • pp.72-77
    • /
    • 2012
  • Phase Contrast MR Angiography(PC MRA) is excellent MRA technique for measuring the velocity of vessels in the human body. PC MRA need to at least four images for angiogram reconstruction and it caused longer scan time. Therefore, we used keyhole imaging combined PC MRA to reduce the scan time. However, keyhole imaging can lead the erroneous effects as loss of phase information or frequency discontinuous. In this study, we applied the keyhole imaging combined 2D PC MRA for improving the temporal resolution and also measured the velocity to evaluate the accuracy of phase information. We used 0.32T MRI scanner(Magfinder II, Scimedix, Korea). Using the 2D PC MRA pulse sequence, the vascular images for a human brain targeted on the Superior Sagittal Sinus(SSS) were obtained. We applied tukey window function for keyhole images to minimize the ringing artifact and erroneous factors that are induced frequency discontinuous and phase information loss. We also applied zero-padded algorithm to peripheral missing k-space lines to compare keyhole imaging results and the artifact power(AP) value was measured on the complex difference images to validate the image quality. Consider as based on our results, heavy image distortions and artifacts were shown until using at least 50% keyhole factor. Using above the 50% keyhole factors are shown well reconstructed and matched for magnitude images and velocity information measurements. In conclusion, we confirmed the image quality and velocity information of keyhole technique combined 2D PC MRA. Especially, measured velocity information through the keyhole imaging combination was similar to the velocity information of full sampled k-space image despite of frequency discontinuous and phase information loss in the keyhole imaging reconstruction process. Consequently, the keyhole imaging combined 2D PC MRA will give some clinical usefulness and advantages as improving the temporal resolution and measuring the velocity information via selecting the appropriate keyhole factor at low tesla MRI system.

3차원 입체정위 유방생검술의 정확도 및 정밀도 평가 (Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy)

  • 이미화
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.213-220
    • /
    • 2015
  • 본 연구는 3차원 입체정위 유방생검술의 정확도를 알아보고, 심부침생검을 이용하여 Stereotactic biopsy과 Sonoguided biopsy의 정확도와 정밀도를 평가하고자 한다. Stereotactic QC phantom을 이용하여 실제 5개의 target 위치로 3D sterotactic machine의 정확도를 측정하고, CT장비로 Scan하여 실측을 구해 X, Y, Z의 길이의 정밀도를 비교한다. 유방조직과 유사하게 제작한 Agar power phantom을 이용하여 5개의 각기 다른 needle tip Target을 통해 3D sterotactic machine과 2D ultrasound machine의 정확도를 비교하고, Z축을 장비별로 실측하여 정밀도와 신뢰도를 비교하며, 6개의 모조병소 Target을 심어놓은 Medical application phantom으로 표적하여 육안검사와 Specimen검사를 통해 정확도를 확인하였다. Stereotactic QC phantom으로 측정한 3D sterotactic machine의 정확도는 100%였으며, CT와 비교한 정밀도는 X, Y, Z축이 모두 p>0.05로 나타났다. Agar powder phantom으로 측정한 두 장비의 정확도는 100%의 정확도를 보였으며, CT와 두 장비 사이에는 p > 0.05로 차이가 없었다. 그러나 2명의 방사선사가 측정한 신뢰도분석에서 3D sterotactic machine은 ICC가 0.954였고, 2D ultrasound machine은 0.785로 2D ultrasound machine이 술자에 따라 차이가 있었다. Medical application phantom의 실험에서 3D sterotactic machine은 Sliced boneless ham을, 2D ultrasound machine은 small chalk powder group를 찾을 수 없었다. Phantom을 이용한 3차원 입체정위 유방생검술의 정확성은 우수하게 나타났고, 인체조직과 비슷한 Agar powder phantom과 유방 조직과 비슷한 Medical application phantom을 이용하여 Stereotactic biopsy과 Sonoguided biopsy의 정확도와 정밀도 모두 우수하게 나타났다. 또한 Medical application phantom의 심부침생검의 정확성 평가에서 각 검사에 따라 생검 표본이 병소의 형태에 따라 상이하게 채취되었고, 3차원 입체정위 유방생검술의 재현성이 유방 초음파검사보다 술자의 영향없이 우수하였다.

INVESTIGATION OF BAIKDU-SAN VOLCANO WITH SPACE-BORNE SAR SYSTEM

  • Kim, Duk-Jin;Feng, Lanying;Moon, Wooil-M.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.148-153
    • /
    • 1999
  • Baikdu-san was a very active volcano during the Cenozoic era and is believed to be formed in late Cenozoic era. Recently it was also reported that there was a major eruption in or around 1002 A.D. and there are evidences which indicate that it is still an active volcano and a potential volcanic hazard. Remote sensing techniques have been widely used to monitor various natural hazards, including volcanic hazards. However, during an active volcanic eruption, volcanic ash can basically cover the sky and often blocks the solar radiation preventing any use of optical sensors. Synthetic aperture radar(SAR) is an ideal tool to monitor the volcanic activities and lava flows, because the wavelength of the microwave signal is considerably longer that the average volcanic ash particle size. In this study we have utilized several sets of SAR data to evaluate the utility of the space-borne SAR system. The data sets include JERS-1(L-band) SAR, and RADARSAT(C-band) data which included both standard mode and the ScanSAR mode data sets. We also utilized several sets of auxiliary data such as local geological maps and JERS-1 OPS data. The routine preprocessing and image processing steps were applied to these data sets before any attempts of classifying and mapping surface geological features. Although we computed sigma nought ($\sigma$$^{0}$) values far the standard mode RADARSAT data, the utility of sigma nought image was minimal in this study. Application of various types of classification algorithms to identify and map several stages of volcanic flows was not very successful. Although this research is still in progress, the following preliminary conclusions could be made: (1) sigma nought (RADARSAT standard mode data) and DN (JERS-1 SAR and RADARSAT ScanSAR data) have limited usefulness for distinguishing early basalt lava flows from late trachyte flows or later trachyte flows from the old basement granitic rocks around Baikdu-san volcano, (2) surface geological structure features such as several faults and volcanic lava flow channels can easily be identified and mapped, and (3) routine application of unsupervised classification methods cannot be used for mapping any types of surface lava flow patterns.

  • PDF

돼지에 있어서 양적 형질 유전자좌(QTL) 발현 특성 분석을 위한 통계적 검정 모형 설정 (Designing of the Statistical Models for Imprinting Patterns of Quantitative Traits Loci (QTL) in Swine)

  • 윤두학;공홍식;조용민;이지웅;최익서;이학교;전광주;오성종;정일정
    • 한국수정란이식학회지
    • /
    • 제19권3호
    • /
    • pp.291-299
    • /
    • 2004
  • 요크셔종과 버크셔종 교배 실험 집단을 활용하여 양적형질 유전자좌 (QTL)의 발현 특성 관련 유전 양식을 조사하였다. 총 512두의 F$_2$ 자손이 F$_1$간의 65교배 조합으로부터 생산되었으며 표현형 조사 기록은 일당증제량(ADG), 평균 등지방 두께(ABF), 10번째 등뼈 부위 등지방 두께(TRF) 및 등심단면적(LEA), 최후 척추부위 등지방 두께 (LRF)였다. 125종의 유전자 표지 (microsatellite)에 대한 3세대 개체별 유전자형이 분석되었으며 이들 정보를 통하여 최소자승 회귀 모형을 이용한 interval mapping 방법을 적용하였다. QTL의 유전양식 여부 검정에 대한 절차를 도식화하기 위해 귀무가설인 통상의 벤델리안 모형에 근거를 두고 수행하였다. 경험적 다중 검정 통계량에 대한 임계치는 단일 개개의 염색체 수준과 게놈 전반에 걸친 실험수준으로 유도하였으며, permutation에 의해 유도된 임계치의 유효성을 검증하기 위해 본 연구에 활용된 실험축 집단 구조와 유사한 simulation 집단 구조에 의해 산출된 결과들과 비교하여 유효성이 인정되었다. 본 연구에 활용된 실험축 집단구조와 Genome 전반에 걸친 QTL imprinting 여부를 조사한 결과 13종의 QTL 에 대한 imprinting이 확인되었으며 이들 중 9종의 QTL 유전 양식은 부계로부터 전달된 자손에게만 발현되는 것으로 추론되었다.

정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구 (A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD)

  • 신동훈;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제12권1호
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF

인공타액에서 아말감의 부식거동에 관한 전기화학적 연구 (ELECTROCHEMICAL STUDY ON THE CORROSION BEHAVIOUR OF DENTAL AMALGAM IN ARTIFICIAL SALIVA)

  • 김영남;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제13권2호
    • /
    • pp.221-235
    • /
    • 1988
  • The purpose of this study was to observe characteristic properties through the polarization curves and EMPA images from 4 different types of amalgam obtained by using the potentiostats (EG & G PARC) & EPMA (Jeol JSM-35), to investigate the degree of corrosion of each phase of amalgam on the oxidation peak, and to identify corrosion products from the corroded amalgam by use of X-ray diffractometer(Rigaku). After each amlgam alloy and Hg were triturated as the direction of the manufacturer by means of the mechanical amalgamator(Shofu), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10mm in height and was condensed by means of routine manner. The specimen was removed from the mold and stored at room temperature for about 7 days. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to compare the corrosion behaviours of the amalgams in 0.9% saline solution(pH6.8~7.0) and artificial saliva (pH6.8~7.0) at $37^{\circ}C$. The open circuit potential was determined after 30 minutes' immersion of specimen in electrolyte and the potential scan was begun at the potential of 100mV cathodic from the corrosion potential. The scan rate was 1mV/sec and the surface area of amalgam exposed to the solution was 0.64$cm^2$ for each specimen. All the potentials reported are with respect to a saturated calomel electrode (SCE). EPMA images on the determined oxidation peaks of each amalgam in artificial saliva were observed. X-ray diffraction patterns of each sample were recorded before and after polarization in artificial saliva (Aristaloy, Caulk Spherical, Dispersalloy and Tytin: at +770mV, +585mV, +8.10m V and +680m V respectively) by use of a recording diffractometer. Nickel filtered Cu $K_{{\alpha}_1}$ radiation was used and sample was scanned at $4^{\circ}(2{\theta})/min.$ from $25^{\circ}$ to $80^{\circ}$. The following results were obtained. 1. Oxidation peak potential in artificial saliva shifted to more anodic direction than that in saline solution. 2. The corrosion potential of high copper amalgam was more anodic than the potential of low copper amalgam. 3. The current density was lower in artificial saliva than in saline solution. 4. One of the corrosion products, AgCl was identified by X-ray diffraction analysis. 5. ${\gamma}_2$ phase was the most susceptible to corrosion and e phase was stable in low copper amalgam and ${\eta}$' phase and Ag-Cu eutectic were susceptible to corrosion in high copper amalgam.

  • PDF

볼밀링법으로 제조된 흑연-실리콘 복합체의 리튬전지 음전극 특성 (Lithium Battery Anode Properties of Ball-Milled Graphite-Silicon Composites)

  • 강근영;신동옥;이영기;김광만
    • Korean Chemical Engineering Research
    • /
    • 제51권4호
    • /
    • pp.411-417
    • /
    • 2013
  • 리튬 2차전지 음전극 활물질로 사용하기 위해, 실리콘(Si) 나노입자(평균입경 100 nm, 0~50 wt%)와 흑연 분말(평균입경 $15{\mu}m$)을 사용하여 볼밀링법으로 흑연-실리콘 복합체 분말을 제조하고 그 전기화학적 특성을 조사하였다. 실리콘 함량이 증가할수록 흑연은 볼밀링에 의해 입경이 작아지고 무정형 특성을 보이는 반면, 실리콘 입자는 나노결정성의 변화 없이 무정형 흑연 내에 싸여진 형태로 유지되었다. 저속 사이클릭 볼타메트리 특성상 0.2~0.35 V와 0.55~0.6 V에서 각각 흑연과 실리콘의 전형적 산화피크가 검출되었고 가역성도 우수(첫 사이클 제외)한 반면, 고속 거동에서는 사이클 반복에 따른 비가역성이 현저하게 나타났다. 또한 충방전 초기에는 큰 비가역 용량이 나타나지만 사이클 경과에 따라 감소하였으며, 특히 실리콘을 20 wt% 정도 포함하는 복합체가 50 사이클에서 약 485 mAh $g^{-1}$의 포화된 방전용량을 나타내었다. 이것은 실리콘을 싸고 있는 흑연의 무정형 상이 실리콘-리튬의 합금/탈합금에 따른 체적 변화를 안정적으로 완충할 수 있는 모폴로지가 재료의 적정 조성(흑연:실리콘=8:2 w/w)에 의해 형성되었기 때문이다.

MRI와 동시에 측정한 뇌전도 신호로 전류원 국지화를 할 때 경사자계 유발 잡음의 영향 분석 (Effects of Gradient Switching Noise on ECD Source Localization with the EEG Data Simultaneously Recorded with MRI)

  • 이항로;한재용;조민형;임창환;정현교;이수열
    • Investigative Magnetic Resonance Imaging
    • /
    • 제7권2호
    • /
    • pp.108-115
    • /
    • 2003
  • 목적 : MRI를 촬영하면서 동시에 측정한 뇌전도 신호에 가장 크게 영향을 미치는 것은 경사자계 유발 잡음이다. MRI와 동시에 측정한 뇌전도 신호에서 전류원 국지화를 수행할 때, 경사자계 유발 잡음이 미치는 영향을 분석하고자 한다. 대상 및 방법 : 사람의 머리와 유사하게 만든 뇌전도 팬텀과 MR compatible 뇌전도 측정시스템, 그리고 3.0 Tesla MRI 시스템을 실험에 사용하였다. 3.0 Tesla MRI 시스템 안에 전류원이 설치되어 있는 뇌전도 팬텀을 놓고, EPI 촬영을 하는 동안 뇌전도 신호를 측정하였다. 경사자계의 세기와 전류원의 위치를 조절하면서 뇌전도 신호 측정을 하였고, 측정된 뇌전도 신호에 대하여 전류원 국지화를 수행할 때 나타나는 국지화 오차를 평가하였다. 결과 : 경사자계 유발잡음에 의한 국지화 오차는 경사자계의 세기와 전류원의 위치에 따라 변화하는 것을 관찰하였다. 또한 경사자계 유발잡음이 Gaussian 잡음보다 전류원 국지화에 미치는 영향이 큰 것을 관찰하였으며, 경사자계 유발 잡음의 전력이 뇌전도 신호 전력의 $10\%$ 이하일 때는 전류원 국지화에 미치는 영향이 미미함을 관찰하였다. 결론 : 경사자계 유발 잡음 전력을 뇌전도 신호 전력의 $10\%$ 이하로 줄인다면 MRI를 하면서 동시에 측정한 뇌전도 신호로도 전류원 국지화를 할 수 있음을 알 수 있었다.

  • PDF

Investigation of light stimulated mouse brain activation in high magnetic field fMRI using image segmentation methods

  • Kim, Wook;Woo, Sang-Keun;Kang, Joo Hyun;Lim, Sang Moo
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권12호
    • /
    • pp.11-18
    • /
    • 2016
  • Magnetic resonance image (MRI) is widely used in brain research field and medical image. Especially, non-invasive brain activation acquired image technique, which is functional magnetic resonance image (fMRI) is used in brain study. In this study, we investigate brain activation occurred by LED light stimulation. For investigate of brain activation in experimental small animal, we used high magnetic field 9.4T MRI. Experimental small animal is Balb/c mouse, method of fMRI is using echo planar image (EPI). EPI method spend more less time than any other MRI method. For this reason, however, EPI data has low contrast. Due to the low contrast, image pre-processing is very hard and inaccuracy. In this study, we planned the study protocol, which is called block design in fMRI research field. The block designed has 8 LED light stimulation session and 8 rest session. All block is consist of 6 EPI images and acquired 1 slice of EPI image is 16 second. During the light session, we occurred LED light stimulation for 1 minutes 36 seconds. During the rest session, we do not occurred light stimulation and remain the light off state for 1 minutes 36 seconds. This session repeat the all over the EPI scan time, so the total spend time of EPI scan has almost 26 minutes. After acquired EPI data, we performed the analysis of this image data. In this study, we analysis of EPI data using statistical parametric map (SPM) software and performed image pre-processing such as realignment, co-registration, normalization, smoothing of EPI data. The pre-processing of fMRI data have to segmented using this software. However this method has 3 different method which is Gaussian nonparametric, warped modulate, and tissue probability map. In this study we performed the this 3 different method and compared how they can change the result of fMRI analysis results. The result of this study show that LED light stimulation was activate superior colliculus region in mouse brain. And the most higher activated value of segmentation method was using tissue probability map. this study may help to improve brain activation study using EPI and SPM analysis.