• Title/Summary/Keyword: C-flux

Search Result 1,783, Processing Time 0.029 seconds

Separation Performance of Disc Plate and Frame Type Reverse Osmosis System (원판틀형 역삼투 시스템의 투과성능)

  • 노상호;이종일;김영채;배성렬;정건용
    • Membrane Journal
    • /
    • v.10 no.3
    • /
    • pp.155-162
    • /
    • 2000
  • The reverse osmosis membrane housing(HY) was developed for excellent distribution of a feed solution, and the separation performance was compared with the commercialized Rochem(RC) system. The permeation flux of HY system was a little lower than that of RC system. On the other hand, the NaCl rejection ra4io was generally higher. Also, the permeation flux and rejection ratio for type A, B and C modules(disc plate and frame type) were measured using NaCl, sucrose and butanol solutions. The separation performance of type C module for NaCL and sucrose solutions was the most effective, and then those of type A and B were followed, respectively. However, the separation performance for butanol solution was type B, C and A order. The flux improvement ratio of type B to A increased as butanol concentration decreased or operating pressure increased up to 28 bar.

  • PDF

Evaporation heat transfer characteristics inside the U-bend of the smooth and the microfin tube using alternative refrigerant (대체냉매를 사용한 평활관 및 마이크로핀관 곡관부내 증발 열전달 특성)

  • Jo, Geum-Nam;Kim, Byeong-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1207-1217
    • /
    • 1997
  • The present work experimentally investigated the effects of mass flux, heat flux, inlet quality on the heat transfer performance inside the U-bend of smooth and microfin tube using R-22 and R-407C refrigerants. The parameters were 200 and 400 kg/m$^{2}$ s for mass flux, 6 and 12 kw/m$^{2}$ for heat flux, 0.1 and 0.2 for inlet quality under the pressure of 0.65 MPa. The apparatus consisted of the test section of four straight sections and three U-bends, preheater, condenser, refrigerant pump, mass flow meter etc. The average heat transfer coefficient at the downstream straight section after U-bend was affected by U-bend due to the centrifugal force and mixing of two-phase flow in the U-bend. The average heat transfer coefficient at the U-bend was 4 ~ 33 % higher than that at the straight section. The average heat transfer coefficients were affected in the order of mass flux, heat flux and inlet quality. The average heat transfer coefficients in the microfin tube were lager by 19 ~ 49% and 33 ~ 69% than that in the smooth tube at the straight section and at the U-bend separately. The average heat transfer coefficients for R-407C were larger by 33 ~ 41% and 17 ~ 29% than that for R-22 in the smooth tube and the microfin tube separately.

Investigation of the Central Carbon Metabolism of Sorangium cellulosum: Metabolic Network Reconstruction and Quantification of Pathway Fluxes

  • Bolten, Christoph J.;Heinzle, Elmar;Muller, Rolf;Wittmann, Christoph
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.1
    • /
    • pp.23-36
    • /
    • 2009
  • In the present work, the metabolic network of primary metabolism of the slow-growing myxobacterium Sorangium cellulosum was reconstructed from the annotated genome sequence of the type strain So ce56. During growth on glucose as the carbon source and asparagine as the nitrogen source, So ce56 showed a very low growth rate of $0.23\;d^{-1}$, equivalent to a doubling time of 3 days. Based on a complete stoichiometric and isotopomer model of the central metabolism, $^{13}C$ metabolic flux analysis was carried out for growth with glucose as carbon and asparagine as nitrogen sources. Normalized to the uptake flux for glucose (100%), cells recruited glycolysis (51%) and the pentose phosphate pathway (48%) as major catabolic pathways. The Entner-Doudoroff pathway and glyoxylate shunt were not active. A high flux through the TCA cycle (118%) enabled a strong formation of ATP, but cells revealed a rather low yield for biomass. Inspection of fluxes linked to energy metabolism revealed that S. cellulosum utilized only 10% of the ATP formed for growth, whereas 90% is required for maintenance. This explains the apparent discrepancy between the relatively low biomass yield and the high flux through the energy-delivering TCA cycle. The total flux of NADPH supply (216%) was higher than the demand for anabolism (156%), indicating additional reactions for balancing of NADPH. The cells further exhibited a highly active metabolic cycle, interconverting $C_3$ and $C_4$ metabolites of glycolysis and the TCA cycle. The present work provides the first insight into fluxes of the primary metabolism of myxobacteria, especially for future investigation on the supply of cofactors, building blocks, and energy in myxobacteria, producing natural compounds of biotechnological interest.

Improvement of Convection by Pulsatile Blood Pump in High Flux Hemodialysis System (고 유량 혈액 투석 시스템에서 박동류 펌프에 대한 대류 향상에 관한 연구)

  • Choi, D.S.;Um, K.M.;Lee, J.C.;Lee, S.R.;Mun, C.H.;Choi, H.;Min, B.G.;Kim, H.C.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.5
    • /
    • pp.376-383
    • /
    • 2008
  • High-flux dialysis treatment removes various toxins via diffusion as well as convection, which is induced by ultrafiltration and backfiltration. In this study, in vitro (Using the distilled water and the bovine's blood) comparison test was performed to determine whether utilization of a high flux dialyzer paired with different pumps would increase the efficiency of convection. At the same blood flow rates, a pulsatile pump and a roller pump were employed to propel the distilled water and bovine whole blood to a high flux dialyzer. Pressures at the dialyzer inlet and outlet in the blood circuit and in the dialysate circuit were measured, respectively. From these data, we calculated the transmembrane pressure and predicted the ultrafiltration and backfiltration rates developed by both pumps. Using the bovine's blood experiment, ultrafiltration and backfiltration rates were 1.6 times higher with the pulsatile pump than with the roller pump. We conclude that utilization of a pulsatile pump in high flux hemodialysis treatments increases ultrafiltration volume, compared with a roller pump under conditions of the same blood flow rate.

Welding Characteristics of A-TIG Using Various Compositions of Active Fluxes (활성플럭스 조성에 따른 A-TIG용접 특성)

  • Kim, Bong-Hun;Gong, Yong-Soo
    • Journal of Welding and Joining
    • /
    • v.32 no.5
    • /
    • pp.26-31
    • /
    • 2014
  • Conventional TIG(C-TIG) welding process guarantees higher quality weldment when compared with other processes. However, C-TIG with inherent low penetration shows disadvantages in productivity, especially for thick-walled structure. To overcome these handicaps, active-flux TIG(A-TIG) welding has been introduced and studied widely in a motivation to improve both quality and productivity. Present study made a focus on optimum combination of oxide components to enhance arc contraction and penetration. Results indicated that arc contraction inducing enhancement of penetration could be possible when composition of active fluxes was well matched with base metal.

On the Study of the Natural Convection in the Fluid near a Vertical Cylinder Heated with Uniform Heat Flux (일정 열유속으로 가열되는 수직원통 주위의 유체에서의 자연대류에 관한 연구)

  • Lee, C.J.;Kim, S.P.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.426-434
    • /
    • 1988
  • Series expansion is applied to solve the laminar boundary layer equations for the problem of natural convection from vertical cylinder with uniform surface heat flux. The series in terms of transverse curvature parameter ${\xi}$ is extended to five terms and is well converged by applying the Shanks transform twice. In case of natural convection from a vertical cylinder heated with uniform surface heat flux, it is possible to consider the vertical cylinder as vertical plate under the condition of D/L${\geq}$A/$(Gr_L^*)^{1/5}$, where A is in the range of 5.7~55.2. Also, mean Nusselt number ${\overline{Nu_L}}$ can be represented as $C_1(Ra_L^*)^{1/5}$, where $C_1$ is a constant which depends on Pr and is in the range of 0.5~0.8.

  • PDF

Flux Variation and Structural Change in 3C 84 with Long-Term Monitoring by KVN and KaVA at Millimeter Wavelengths

  • Wajima, Kiyoaki;Kino, Motoki;Kawakatu, Nozomu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.45.2-46
    • /
    • 2017
  • 3C 84 (NGC 1275) is one of the most famous radio galaxies and a lot of VLBI observations have been conducted to date because of its brightness and proximity (z = 0.0176; 1 mas = 0.36 pc). The source is entering a significantly active phase with long-term increase in radio flux at cm wavelengths since 2005, and the increased activity at very-high-energy (VHE) gamma rays. In order to study properties of sub-pc-scale structure and the circumnuclear environment in 3C 84, we have conducted multi-epoch VLBI observations with the Korean VLBI Network (KVN) at 86 and 129 GHz, and monthly monitoring by the KVN and VERA Array (KaVA) at 43 GHz from 2015 August. Following the report in the previous KAS meeting (cf. 2016 KAS Autumn Annual Meeting, [구 GC-10]), we present further results mainly on the basis of twelve-epoch observations with KaVA at 43 GHz. Through the monthly monitoring with KaVA, we found that peak intensity of the pc-scale southern lobe (C3) was increased from $2.60\;Jy\;beam^{-1}$ in 2015 October to $9.80\;Jy\;beam^{-1}$ in 2016 June, corresponding to a flux increase of 3.7 times in eight months. We also detected change in direction of motion of C3 from transversal to outward with respect to C1, concurrently with the beginning of its flux increase in 2015 October. We consider that these phenomena are due to interaction of C3 with the ambient medium, and are related to the gamma-ray flare which has been detected with VHE gamma-ray telescopes such as MAGIC and VERITAS.

  • PDF

Subcooled Burnout Heat Flux on a Heated Surface with Impinging Water Jet (충돌수분류(衝突水噴流)에 의한 서브쿨 Burnout열류속(熱流束)에 관한 연구)

  • Ohm, K.C.;Lee, J.S.;Park, S.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.527-536
    • /
    • 1996
  • Convective nucleate boiling and burnout heat flux have been studied on a flat, downward facing, constant heat flux surface cooled by an impinging water jet. The tests are progressed from low, nonboiling power to high, burnout heat flux power. The jet velocity and the subcooling do not affect the nucleate boiling curve of $q{\sim}{\Delta}T_{sat}$ diagram, but the supplementary water height affects the curve. For the case of dimensionless height of supplementary water S/D=1, the boiling curve shift to the heigher heat flux than that of S/D=0 or S/D=2. Burnout heat flux is enhanced with increasing jet velocity and subcooling. Also. by using the supplementary water(S/D=1 or S/D=2), burnout heat flux is larger than that of the simple water jet(S/D=0). A generalized correlation for the burnout heat flux data in the present boiling system with an impinging water jet is successfully evolved.

  • PDF

접착형 박막 측온게이지식 열류센서의 개발에 관한 연구

  • 한응교;박두원;최규철;노병옥;이명호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.11a
    • /
    • pp.80-86
    • /
    • 1991
  • In this study an the development of the heat flux sensor with thermocouple, the heat-treated adhesive type film nickel gauge(Ni-Gauge) for measuring temperature was used. and this Ni-Gauge is not only comparable for platinum gauge(Pt-Gauge) in linearity, but also economically cheap. And from this viewpoint. numerical analysis is essential to investigate charateristics of sensor, since this analysis is capable of simulating precise boudary condition and practical conditions and so on. By the way. there are many types of heat flux sensor. of which adhesive type flux sensor is common, in the study this type of heat flux sensor was chogen. and analysis of the sensor is considered as a kind of open cavity figure. performed by SIMPLER algorithm. As a result. through temperature distributial of the sensor by numerical analysis in steady and unsteady state, the dracteristics of the acdhesive type heat flux sensor(lst heat flux sensor) acooodinge to heat flux, that is, outvoltage, sensitivity. and responsibilty could be evaluated. in addition, time of improved heat flux sensor(2nd heat flux sensor) could be predicted fran the reflectian of proper operating temperature(l50 $^{\circ}C$)of theNi-Gauge.

  • PDF

Current Limiting and Voltage Sag Suppressing Characteristics of Flux-lock Type SFCL According to Variations of Turn Number's Ratio (자속구속형 초전도전류제한기의 권선비 변화에 따른 전류제한 및 전압강하 보상 특성)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.410-415
    • /
    • 2011
  • In this paper, we investigated the fault current limiting and the load voltage sag suppressing characteristics of the flux-lock type SFCL, designed with the additive polarity winding, according to the variations of turn number's ratio and the comparative analysis between the resistive type and the flux-lock type SFCLs were performed as well. From the analysis for the short-circuit tests, the flux-lock type SFCL designed with the larger turn number's ratio was shown to perform more effective fault current limiting and load voltage sag suppressing operations compared to the flux-lock type SFCL designed with the lower turn number's ratio through the fast quench occurrence of the high-$T_C$ superconducting (HTSC) element comprising the flux-lock type SFCL. In addition, the recovery time of the flux-lock type SFCL after the fault removed could be confirmed to be shorter in case of the flux-lock type SFCL designed with the lower turn number ratio.