• Title/Summary/Keyword: C-flux

Search Result 1,783, Processing Time 0.026 seconds

Manufacture and Experiment of Compensated Ionization Chamber for the Nuclear Power Reactor (동력로용 보상형 전리함의 제작 및 실험)

  • 육종철;고병준;박용집
    • 전기의세계
    • /
    • v.19 no.4
    • /
    • pp.18-23
    • /
    • 1970
  • A neutron detector, in general, can not be utilized as the thermal neutron detecting chamber in the nuclear power reactor, especially P.W.R. due to the characteristics of high temperature, high pressure and high neutron flux in a reactor vessel. We have performed an experiment to detect the thermal neutrons at 400.deg. C and high flux of thermal neutron in a power reactor. Coating boron-10 on the aluminium plates by means of surface diffusion method at 600.deg. C for 5 hours in an electric furace, also we made a typical chamber which was compensated ionization chamber filled with free air as an ionization gas. It was checked the chamber characteristics in the TRIGA MARK-II Reactor at the power level from zero to 250KW. The chamber current showed a perfect linear increase to power increase. However, many variation of the measured current were observed within the power of 50KW.

  • PDF

Experimental Study of Collision Angle Effects on Heat Transfer During Droplet-wall Collision in Film Boiling Regime (막비등 영역에서 액적-벽면 충돌 시 충돌각도가 열전달에 미치는 영향에 관한 실험적 연구)

  • Park, Junseok;Kim, Hyungdae
    • Journal of ILASS-Korea
    • /
    • v.22 no.3
    • /
    • pp.129-136
    • /
    • 2017
  • Effects of collision angle on heat transfer characteristics of a liquid droplet impinging on a heated wall above the Leidenfrost point temperature were experimentally investigated. The heated wall and droplet temperatures were $506^{\circ}C$ and $100^{\circ}C$, respectively, and the impact angle varied from $20^{\circ}$ to $90^{\circ}$ while the normal collision velocity was constant at 0.27 m/s. The droplet collision behaviors and the surface temperature distribution were measured using synchronized high-speed video and infrared cameras. The major physical parameters influencing upon droplet-wall collision heat transfer, such as residence time, wall heat flux, effective heat transfer area, heat transfer amount, were analyzed. It was found at the constant normal collision velocity that the residence time, wall heat flux and effective heat transfer area were hardly not changed, resulting in the almost constant heat transfer amount.

Magnetic relaxation measurement of infinite layer superconductor Sr$_{0.9}$La$_{0.1}$CuO$_2$

  • Kim, Heon-Jung;Kim, Mun-Seog;Cung, C.U.;Kim, Ji-Yeon;Lee, Sung-Ik
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.121-124
    • /
    • 2000
  • The time dependence of irreversible magnetization of grain aligned infinite layer superconductor Sr$_{0.9}$La$_{0.1}$CuO$_2$ was measured in temperature range of 2 K < T < 30 K for H= 0.5 T, 1.0 T and 1.5 T parallel to c-axis. From this, we calculated normalized flux creep rate S(T) ${\equiv}$ dlnM/dlnt and found that the temperature independent region in S(T) is significantly wide in comparision with other cuprate superconductors. Using the method of Maley et al., we also deduce the current density dependence of pinning potential and glassy exponent ${\mu}$.

  • PDF

The Evaporation Shape of Deposited Droplet on the Hot Surface (고온표면에 부착된 액적의 증발형상 변화)

  • Bang Chang-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.68-74
    • /
    • 2005
  • The objective of the present work is to examine the evaporation shape of deposited droplet on the hot surface. this paper performed the experiments as following conditions: (a) the surface temperature is within the range between $80^{\circ}C$ and $95^{\circ}C$ in the conduction and radiation, (b) droplet diameter is 3.0mm. The results are as follows; while droplet evaporates, droplet's radius is kept changelessly to $70\%$ evaporation time and droplet's shape is kept changelessly after. In case use Constant radius model, about $10\%$ is appearing high than value that time-averaged heat flux applies Inverse heat conduction.

Recent Development of Bulk High-Tc Superconductors

  • Yoo, Sang-Im
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.88-95
    • /
    • 2002
  • Recent development in the field of RE-Ba-Cu-O (REBCO, RE: Y or rare earth elements) bulk high-Tc superconductors (HTS) is reviewed in the present paper. After the fatal weak link problem of sintered REBCO superconductors has been overcome by melt processing, this field has been greatly advanced during last ten years. The critical current density $J_c$ at 77 K has been enhanced by introducing effective flux pinning sites into the $REBa_2Cu_3O_y$ (RE123) superconducting matrix. Large melt-textured REBCO bulk crystals have been fabricated with the TSMG(top-seeded melt growth) technique. Mechanical properties of REBCO bulks have been improved by using the Ag additive or epoxy resin. Real bulk applications such as current lead, fault current limiter, flywheel energy storage system, magnetic field source, magnetic separation system, and etc., surely come true near future.

  • PDF

Characterization of Surface Modified Polysulfone Membranes with Various Fluorine Chemicals

  • Lee, Choong-Sub;Rhim, Ji-Won
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.20-24
    • /
    • 2002
  • The surface of polysulfone membranes has been modified using the fluorine chemicals, ITFE (2-iodo-1,1,1-trifluoro-ethane F.W.=209.94) and PFPI (1H,1H-pentafluoro-n-propyl iodide F.W.=259.95), and PFI (1H,1H,2H,2H-perfluorohexyl iodide, F.W.=373.99) based on Friedel-Crafts reaction mechanism with varying reaction temperatures, reaction time, and catalysis types. The resulting membranes were characterized through mainly the contact angle measurement and pure water permeability. The smaller reactant shows the larger contact angles. FeBr$_3$ catalyst is more effective than AlCl$_3$. Typically, the PS film treated with ITFE at $25^{\circ}C$ under FeBr$_3$ catalyst showed the contact angle 78.5$^{\circ}C$ which indicated 10% over the value of unreacted PS films. More than 50% of pure water flux 8.0 g/$m^2$hr, reduced at reaction time 10 min relative to the original flux, 3.49 g/$m^2$hr.

Characteristics Analysis and Test of a Voice-Coil-Type LOA Considering the Push/pull Effects (Push/Pull Effect를 고려한 보이스코일형 LOA의 특성해석 및 시험)

  • Jang, S.M.;Jeong, S.S.;Park, H.C.;Moon, S.J.;Park, C.I.;Chung, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.275-277
    • /
    • 1998
  • The effect of the coil flux, so called "push/pull effect", is to shift the airgap flux density variation due to the magnet alone by a certain amount. Thrust therefore is shift downward or upward. The push/pull effect was presented through the FEM analysis and static tests. We compared with the thrust obtained through the FEM analysis and static tests.

  • PDF

Flux Pinning Properties of REBCO coated conductors for High Field Magnets

  • Awaji, Satoshi;Watanabe, Kazuo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.4
    • /
    • pp.1-4
    • /
    • 2011
  • From the viewpoint of high field application, the mechanical and critical current properties of recently developed $REBa_2Cu_3O_y$ (RE123, RE: rare-earth) coated conductors are summarized. In addition, effective flux pinning mechanisms in RE123 are also introduced. As one of the examples for high field application, the upgrading of the 18 T cryogen-free superconducting magnet is shown. The large anisotropy of $J_c$ is a problem at low temperature and high magnetic field. The nanorod is considered as the useful methods to improve the anisotropy of $J_c$, although its efficiency becomes small at low temperature.

Measurement of Single Phase and Condensation Heat Transfer Coefficients of Ammonia in a Horizontal Tube (암모니아의 수평관내 단상 및 응축 열전달계수의 측정)

  • 백영진;장영수;김영일
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.561-569
    • /
    • 2000
  • Single phase and condensation heat transfer characteristics of ammonia in a horizontal tube have been investigated experimentally The horizontal test section is composed of smooth SUS316 tube for refrigerant flow, surrounding annulus for water flow, and temperature and Pressure measuring sensors. For single phase test, subcooled ammonia mass flux was varied from 320 to 501 kg/mrs and temperature was varied from 18 to $47^{\circ}C$. For condensation test, mass flux and saturation temperature were varied from 86 to 128 kg/$m^2$s and 34 to $47^{\circ}C$, respectively. The equations of Gnielinski Soliman et al., Traviss et at., Cavallini and Zecchin, Shah, Chen et al., Tandon et al., and Chilli and Anand were compared with the experimental data. New correlations are proposed based on the experimental results and the absolute mean deviation of the experimental data becomes 1.0% for single phase test and 4.9% for condensation test.

  • PDF

Forced convective boiling heat transfer for a ternary refrigerant mixture inside a horizontal tube (수평관내 3성분 혼합냉매의 강제대류비등 열전달)

  • 오종택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.912-920
    • /
    • 1999
  • The forced convective boiling heat transfer coefficients of R-407C were measured inside a horizontal tube 6.0mm I.D. and 4.0m long. The heat transfer coefficients increased according to an increase in heat flux at constant mass flux. Because nucleation was completely suppressed in the two-phase flow region with high quality, heat transfer coefficients in forced convective evaporation were higher than those in nucleate boiling region. Average heat transfer coefficients of R-407C were about 30 percent lower than the pure refrigerant correlation, due to mass transfer resistance at the gas-liquid interface. However, the total experimental data shows an agreement with the predicted data for ternary refrigerant mixtures with a mean deviation of 30%.

  • PDF