Realization of 3D Image on Metal Plate by Optimizing Machining Conditions of Ultra-Precision End-Milling (초정밀 엔드밀링 가공조건 최적화를 통한 금속상의 3차원 이미지 구현)

  • Lee, Je-Ryung;Moon, Seung Hwan;Je, Tae-Jin;Jeong, Jun-Ho;Kim, Hwi;Jeon, Eun-chae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.885-891
    • /
    • 2016
  • 3D images are generally manufactured by complex production processes. We suggested a simple method to make 3D images based on a mechanical machining technology in this study. We designed a tetrahedron consisted of many arcs having the depth of $100{\mu}m$ and the pitch of $500{\mu}m$, and machined them on an aluminum plate using end-milling under several conditions of feed-rate and depth of cut. The area of undeformed chip including depth of cut and feed-rate can predict quality of the machined arcs more precisely than the undeformed chip thickness including only feed rate. Moreover, a diamond tool can improve the quality than a CBN tool when many arcs are machined. Based on the analysis, the designed tetrahedron having many arcs was machined with no burr, and it showed different images when observed from the left and right directions. Therefore, it is verified that a 3D image can be designed and manufactured on a metal plate by end-milling under optimized machining conditions.

Multiple Regression Analysis for Piercing Punch Profile Optimization to Prevent Tearing During Tee Pipe Burring (다중 회귀 분석을 활용한 Tee-Pipe 버링 공정에서 찢어짐 방지를 위한 피어싱 펀치 형상 최적 설계)

  • Lee, Y.S.;Kim, J.Y.;Kang, J.S.;Hong, S.
    • Transactions of Materials Processing
    • /
    • v.26 no.5
    • /
    • pp.271-276
    • /
    • 2017
  • A tee is the most common pipefitting used to combine or divide fluid flow. Tees can connect pipes of different diameters or change the direction of a pipe run. To manufacture tee type of stainless steel pipe, combinations of punch piercing and burr forming have been widely used in the industry. However, such method is considerably time consuming with regard to performing empirical work necessary to attain process conditions to prevent upper end tearing of the tee product and meet target tee height. Numerous experiments have shown that the piercing profile is the main cause of defects mentioned above. Furthermore, the mold design is formed through trial and error according to pipe diameters and changes in requirements. Thus, the objective of this study was to perform piercing and burring process analysis via finite element analysis using DYNAFORM to resolve problems mentioned above. An optimization design method was used to determine the piercing punch profile. Three radii of the piercing punch (i.e., large, small, and joined radii) were selected as design variables to minimize thinning of a tee pipe. Based on results of correlation and multiple regression analyses, we developed a predictive approximation model to satisfy requirements for both thickness reduction and target height. The new piercing punch profile was then applied to actual tee forming using the developed prediction equation. Model results were found to be in good agreement with experimental results.

Brain Abscess Uptake at TI-201 Brain SPECT (탈륨-201 SPECT에서 뇌농양 집적)

  • Lee, Won-Hyoung;Han, Eun-Ji;Yoo, le-Ryung;Chung, Yong-An;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Choi, Yeong-Jin
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.339-341
    • /
    • 2007
  • A 22-year-old woman with a history of acute lymphoblastic leukemia was hospitalized for headache and vomiting. CT scan showed a well-defined, ring like enhancing mass in the left frontal lobe with surrounding edema and midline shift. Magnetic resonance imaging demonstrated a round homogeneous mass with a ring of enhancement in the left frontal lobe. Tl-201 brain SPECT showed increased focal uptake coinciding with the CT and MRI abnormality. Aspiration of the lesion performed through a burr hole yielded many neutrophils, a few lymphocytes and histiocytes with some strands of filamentous microorganism-like material. Modified AFB stained negative for norcardia. Gram stain showed a few white blood cells and no microorganism. Antibiotics were started and produced a good clinical response. After one month, CT scan showed markedly reduction in size and extent was observed.

FPCB Cutting Process using ns and ps Laser (나노초 및 피코초 레이저를 이용한 FPCB의 절단특성 분석)

  • Shin, Dong-Sig;Lee, Jae-Hoon;Sohn, Hyon-Kee;Paik, Byoung-Man
    • Laser Solutions
    • /
    • v.11 no.4
    • /
    • pp.29-34
    • /
    • 2008
  • Ultraviolet laser micromachining has increasingly been applied to the electronics industry where precision machining of high-density, multi-layer, and multi material components is in a strong demand. Due to the ever-decreasing size of electronic products such as cellular phones, MP3 players, digital cameras, etc., flexible printed circuit board (FPCB), multi-layered with polymers and metals, tends to be thicker. In present, multi-layered FPCBs are being mechanically cut with a punching die. The mechanical cutting of FPCBs causes such defects as burr on layer edges, cracks in terminals, delamination and chipping of layers. In this study, the laser cutting mechanism of FPCB was examined to solve problems related to surface debris and short-circuiting that can be caused by the photo-thermal effect. The laser cutting of PI and FCCL, which are base materials of FPCB, was carried out using a pico-second laser(355nm, 532nm) and nano-second UV laser with adjusting variables such as the average/peak power, scanning speed, cycles, gas and materials. Points which special attention should be paid are that a fast scanning speed, low repetition rate and high peak power are required for precision machining.

  • PDF

A Study of Automobile Product Design using Hole Expansion Testing of High Strength Steels (고장력강의 구멍 확장 실험을 이용한 자동차부품 설계연구)

  • Park, B.C.;Bae, K.U.;Gu, S.M.;Jang, S.H.;Hong, S.H.;Kim, Y.S.
    • Transactions of Materials Processing
    • /
    • v.19 no.6
    • /
    • pp.337-343
    • /
    • 2010
  • Current need of weight reduction in automotive part increases the application for high strength steel (HSS). The various types of high strength steels have been used to produce chassis part, control arms and trailing arms for weight reduction and increasing of fatigue durability such as dual phase steel (DP) and ferrite bainite steel (FB). But, DP and FB steels have proven to show inferiority in durability as well as press formability. Edge cracking occurred often in flange forming and hole expansion processes is the major failure encountered. This paper discussed the behavior of edge stretchability of high strength steel of DP and FB steels. Experimental works have been conducted to study the effect of punch clearance and burr direction on hole expansion ratio (HER). Also finite element simulation (FEM) has been preformed to clarify the mechanism of flange crack and support the experimental results on HER of DP and FB steels. It was simulated the whole process of blanking process following by hole expansion process and ductile fracture criterion named the modified Cockcroft-Latham model which was used to capture the fracture initiation. From the hole expansion tests and FEM simulation studies it was concluded that ferrite bainite steel showed better stretch-flangeability than dual phase steel. It was attributed to the lower work hardening rate of ferrite bainite steel than dual phase steel at the sheared edge.

Research on ultra-precision fine-pattern machining through single crystal diamond tool fabrication technology (단결정 다이아몬드공구 제작 기술을 통한 초정밀 미세패턴 가공 연구)

  • Jung, Sung-Taek;Song, Ki-Hyeong;Choi, Young-Jae;Baek, Seung-Yub
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.63-70
    • /
    • 2020
  • As the consumer market in the VR(virtual reality) and the head-up display industry grows, the demand for 5-axis machines and grooving machines using on a ultra-precision machining increasing. In this paper, ultra-precision diamond tools satisfying the cutting edge width of 500 nm were developed through the process research of a focused ion beam. The material used in the experiment was a single-crystal diamond tool (SCD), and the equipment for machining the SCD used a focused ion beam. In order to reduce the influence of the Gaussian beam emitted from the focused ion beam, the lift-off process technology used in the semiconductor process was used. 2.9 ㎛ of Pt was coated on the surface of the diamond tool. The sub-micron tool with a cutting edge of 492.19 nm was manufactured through focused ion beam machining technology. Toshiba ULG-100C(H3) equipment was used to process fine-pattern using the manufactured ultra-precision diamond tool. The ultra-precision machining experiment was conducted according to the machining direction, and fine burrs were generated in the pattern in the forward direction. However, no burr occurred during reverse machining. The width of the processed pattern was 480 nm and the price of the pitch was confirmed to be 1 ㎛ As a result of machining.

A Case Report of Symptomatic Torus Palatinus (구개 융기의 치험례)

  • Kwon, Jun-Seong;Choi, Hwan-Jun;Yang, Hyung-Eun;Tark, Min-Seong
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.473-476
    • /
    • 2010
  • Purpose: Torus palatinus is a bony prominence at the middle of the hard palate. The size varies from barely discernible to very large, from flat to lobular. This oral exostosis is not a disease or a sign of disease, but if large, may be a problem. So, we present the clinical and histopathologic features and applied therapy and provide a comprehensive review of the rare case of the symptomatic exostoses. Methods: A 37-year-old woman had slowly growing exophytic nodular mass of the bone that arises the midline suture of the hard palate. The patient was concerned about discomfort associated with movement of her tongue and about frequent irritation of the palatal mucosa during mastification of the hard food. The patient had a large, unilobulated torus palatinus. It extended from the area adjacent to the canine to a point beyond the junction with the soft palate. The mass was oblong in shape, measuring about 3 cm long, 2 cm wide, and 0.8 cm in height. Results: Before surgical intervention a CT was obtained for the sake of estimating the thickness of the bone between the exostoses and the maxillary antrum and floor of the nose. The surgical procedure was performed with the patient under general anesthesia. Removal of the exostosis was performed after midline mucoperiosteal incision with osteotome and diamond burr. Histologic finding revealed decalcified dense bony tissue, the presence of lacunae, and normal osteocytes. Conclusion: Surgical removal is recommended when one or more of the following condition exist: interference with the construction of prosthesis, interference with oral function, irritation or pathology of the overlying tissue, inability of the patient to maintain proper oral hygiene, and fear of malignancy or other psychologic trauma. We report a rare case of the torus arising in hard palate with symptoms.

A Study on Performance Improvement of Light and Low-Noisy Standing Grinder with Vacuum Dust Collection Using a Cyclone Separator (사이클론을 활용한 경량.저소음 진공집진 스탠딩 그라인더의 성능개선에 관한 연구)

  • Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4732-4737
    • /
    • 2011
  • A standing grinder with a vacuum dust collection, which works grinding a surface and collecting dust occurred simultaneously, is needed to clean the surface before painting, or to remove a weld bead burr in the industrial field. In recent it trends to be compact and potable with high grinding and dust collection power, and low noise. As increasing these grinding and dust collection power, the noise and weight of standing grinder occurs an important problem. To solve these problem, an efficient cyclone separator was designed and developed by Ansys-CFX analysis and experiments. A weight of the developed grinder part was 5.9kg, which can be easily handled on standing by workers. and a noise level of the developed prototype was measured 69.9 dB(A).

Hyperacute Radiation Effect on Cerebral Cortex after Local Gamma-irradiation in the Rat Brain (단일 국소방사선 조사 후 백서 대뇌 피질의 초급성기 변화에 대한 연구)

  • Kang, Shin-Hyuk;Chung, Yong-Gu;Kim, Han-Kyum;Kim, Chul-Yong;Lee, Hoon-Kap
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.5
    • /
    • pp.370-374
    • /
    • 2005
  • Objective: We investigated the morphologic changes within 24 hours after a single ${\gamma}$-irradiation in the rat brain. Methods: Forty Sprague-Dawley rats were used. After a burr hole trephination on right parietal area, cerebral hemisphere was irradiated with 2Gy and 5Gy using iridium-192($^{192}Ir$), respectively. The effect was assessed at 4, 8, 12 and 24 hours after irradiation. The histological changes were scored following the detection of edema or disarray severity. TUNEL-positive cells exhibiting apoptotic morphology were counted in irradiated region. Results: Cortical edema and disarray were initially showed at 4 or 8 hour and almost all defined at 24 hour after irradiation. And the injury was wedge shape. TUNEL-positive cells were minimal at 8 hour after irradiation as the number of positive cells were $2.6{\pm}5.27$(n=5) after 2Gy, and $0.8{\pm}0.84$(n=5) after 5Gy. But, the number of apoptotic cells were increased markedly to $60{\pm}6.24$ at 12 hour after 2Gy and to $104{\pm}19.7$ at 24 hour after 5Gy. Conclusion: There were prominent morphologic changes immediately after ${\gamma}$-irradiation. And, apoptosis was increased according to the time period. These findings implicate that brain irradiation induces rapid apoptotic change, which may play an important role in the pathogenesis of radiation-induced pathologic conditions.

Endoscopic Spine Surgery

  • Choi, Gun;Pophale, Chetan S;Patel, Bhupesh;Uniyal, Priyank
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.5
    • /
    • pp.485-497
    • /
    • 2017
  • Surgical treatment of the degenerative disc disease has evolved from traditional open spine surgery to minimally invasive spine surgery including endoscopic spine surgery. Constant improvement in the imaging modality especially with introduction of the magnetic resonance imaging, it is possible to identify culprit degenerated disc segment and again with the discography it is possible to diagnose the pain generator and pathological degenerated disc very precisely and its treatment with minimally invasive approach. With improvements in the optics, high resolution camera, light source, high speed burr, irrigation pump etc, minimally invasive spine surgeries can be performed with various endoscopic techniques for lumbar, cervical and thoracic regions. Advantages of endoscopic spine surgeries are less tissue dissection and muscle trauma, reduced blood loss, less damage to the epidural blood supply and consequent epidural fibrosis and scarring, reduced hospital stay, early functional recovery and improvement in the quality of life & better cosmesis. With precise indication, proper diagnosis and good training, the endoscopic spine surgery can give equally good result as open spine surgery. Initially, endoscopic technique was restricted to the lumbar region but now it also can be used for cervical and thoracic disc herniations. Previously endoscopy was used for disc herniations which were contained without migration but now days it is used for highly up and down migrated disc herniations as well. Use of endoscopic technique in lumbar region was restricted to disc herniations but gradually it is also used for spinal canal stenosis and endoscopic assisted fusion surgeries. Endoscopic spine surgery can play important role in the treatment of adolescent disc herniations especially for the persons who engage in the competitive sports and the athletes where less tissue trauma, cosmesis and early functional recovery is desirable. From simple chemonucleolysis to current day endoscopic procedures the history of minimally invasive spine surgery is interesting. Appropriate indications, clear imaging prior to surgery and preplanning are keys to successful outcome. In this article basic procedures of percutaneous endoscopic lumbar discectomy through transforaminal and interlaminar routes, percutaneous endoscopic cervical discectomy, percutaneous endoscopic posterior cervical foraminotomy and percutaneous endoscopic thoracic discectomy are discussed.