• Title/Summary/Keyword: Buried Type

Search Result 208, Processing Time 0.025 seconds

Magnetic Sensitivity Improvement of Silicon Vertical Hall Device (Si 종형 Hall 소자의 자기감도 개선)

  • Ryu, Ji-Goo;Kim, Nam-Ho;Chung, Su-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.260-265
    • /
    • 2011
  • The silicon vertical hall devices are fabricated using a modified bipolar process. It consists of the thin p-layer at Si-$SiO_2$, interface and n-epi layer without $n^+$buried layer to improve the sensitivity and influence of interface effects. Experimental samples are a sensor type I with and type H without p+isolation dam adjacent to the center current electrode. The experimental results for both type show a more high current-related sensitivity than the former's vertical hall devices. The sensitivity of type H and type I are about 150 V/AT and 340 V/AT, respectively. This sensor's behavior can be explained by the similar J-FET model.

The Buried Type Reference Electrode for Real time Wireless Remote Monitoring System for Stray Current of Subway System (지하철 누설전류의 실시간 무선 원격 감시 시스템용 매설형 기준전극)

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Lee, Jae-Duck;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2732-2734
    • /
    • 2005
  • In present, most of metallic structures(gas pipeline, oil pipeline, water pipeline, etc) are running parallel with subway and power line in seoul. Moreover subway system and power line make a stray current due to electrical corrosion on metallic structures. The owner of metallic structures has a burden of responsibility for the protection of corrosion and the prevention against big accident such as gas explosion or soil pollution and so on. So, they have to measure and analyze the data about P/S(Pipe to Soil) potential due to stray current of subway system. So, we have developed the Real-time Wireless Remote Monitoring System for Stray Current of Subway System. In this system, the permanent buried type reference electrode is necessary. In this paper, results of development about the permanent buried type reference electrode($Cu/CuSO_4$) are presented.

  • PDF

The interface effects on polarization dependence of waveguide and the design of polarization independent 2 dimensional waveguide on InP for arrayed waveguide grating (도파로의 편광 의존성에 경계면이 미치는 효과와 편광 독립적인 InP형 배열 도파로 회절 격자 소자를 위한 2차원 광 도파로의 설계)

  • 김동철;최정훈;유건호;김형문;주흥로;김홍만
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 1998
  • We have studied the effects of interface on polarization dependence of waveguide and designed the polarization independent 2-dimensional waveguides on InP for arrayed waveguide grating. To figure out the effects of interface on polarization dependence, we have solved the 1-dimensional wave equation using a transfer matrix method. It is shown that the birefringence becomes stronger as the number of interfaces increases. In order to design polarization independent 2-dimensional waveguides, we have used effective index method. The structures considered are ridge type, raised strip type, and buried type waveguide. In the cases of ridge and raised strip type, conventional effective index method was used. In the case of buried type corrected effective index method was used. We have determined the height and width of waveguides such that the waveguides become polarization independent.

  • PDF

A Study on the Status of Use and Value of 'Saemi' in Sacheon Alluvial Fan (사천 선상지 '새미'의 이용 실태 및 가치 고찰)

  • Kim, Dohyun;Jeong, Myeong Cheol;Seo, Ki Chun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.24 no.4
    • /
    • pp.85-95
    • /
    • 2022
  • This study is about the story of 'Saemi', existing in the Sacheon Alluvial fan area. Saemi is a local word for Dumbeong, which is the traditional water irrigation facilities in this area that could be formed according to the geographical characteristics of a Alluvial fan site. In the meantime, although Saemi has been an important source of water, related research has been mainly done from an ecological point of view. Accordingly, the researcher paid attention to the functional aspects of Saemi itself, grasped its location, distribution status, and usage including the construction method, and considered its intrinsic value through classification and characteristic analysis of Saemi. As a result of five field surveys from September 2021 to October 2022, 129 Saemies remained in the Sacheon alluvial fan area. According to the structure and shape, Saemi could be divided into basic type, complex type, and buried type. The basic type was subdivided into bucket-type and stairs-type along with the complex type, and the buried type was subdivided into all buried-type and some buried-type. Saemies were mainly distributed at the distal end of the Sacheon alluvial fan site, individual Saemies were built on farmland, and common Saemies were usually built along roadsides adjacent to villages. The reason why the Saemies are concentrated at the distal end is the geographical characteristics of the alluvial fan where the water underflows. Saemi was an important multifunctional water supply source equivalent to the main water source for people at the distal end of the pond who did not receive a stable supply of water from the reservoir. Saemi was at the center of the underground water irrigation network agricultural system in the Sacheon alluvial fan area according to the principles of 'bbaeim(drop out)' and 'gaepim(pooling)' It has provided a foundation for establishing itself as an appropriate technology in this area. Such Saemi contributed to the rural landscape and agricultural biodiversity through its own system and served as a public interest function. It is necessary to know, conserve, manage, and continuously utilize the value of this Saemi as an agricultural heritage.

Fabrication and Characteristics of Oxygen Gas Sensor using Fluoride Compaunds (불화물을 이용한 산소센서의 제조및 특성)

  • 이재현;홍영호;장동근;이병택;김태훈;이덕동
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1993.11a
    • /
    • pp.69-71
    • /
    • 1993
  • Fluoride compound potentiometric cell oxygen sensors were fabricated for the measurement of oxygen pressure in the low temperature range (300。K-500。K). The disk type sensors consist of a reference Air(0$_2$):Ag, a solid electrolyte SrF$_2$, and a sensing metel Ag electrode. And the buried reference electrode type sensor have a NiO/Ni reference electrode. The open circuit emf of the cell showed high sensivity to oxygen gas (60mv) at the measuring temperature 20$0^{\circ}C$. Also, The buried reference electrode type sensor showed 30mv from 1% to 10% oxygen pressure range.

  • PDF

Settlement Characteristics of Three Type of Artificial Reefs on Sandy Bottom in the Eastern Coast of Korea (동해안 사질지반에 시설된 인공어초 3종의 매몰 특성)

  • Kim, Dae-Kweon;Kim, Wan-Ki;Son, Yong-Soo;Yoon, Jang-Tack;Gong, Yong-Gun;Kim, Young-Dae;Lee, Ji-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.359-364
    • /
    • 2008
  • Using multi beam echo sounder, side scan sonar and scuba diving equipment, ceramic type, uneven type and semicircle-ramus type reefs into sandy bottom were ascertained, the depth of submersion in 7.2-10.3m on the coast of Gangneung, East of Korea, forty uneven type artificial reefs(AR) were totally buried into the sandy bottom. Two of five semicircle-ramus type ARs had only of their top area exposed. For most of the 45 ceramic reefs, only the upper 25-150cm of ARs were visible. The burial pattern is different in west and east side of the reefs, where the east side is deeply buried compared to the west side. From these results. it is recommended that sufficient analysis of bottom structure and materials especially in the sandy sea area should be undertaken in order to determine the best type of artificial reefs to be deployed and the best location for depoloyment.

Design problem of Line (선형 집적회로(IC) 설계의 문제점)

  • 김만진
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.3
    • /
    • pp.22-27
    • /
    • 1976
  • For linear IC design, one has to know the epi thickness, resistivity, and structure of buried island inserted between epi and substrate because the mask structure can only be changed for linear IC consisted of various type of transistors to be made for desired specific function. The interrelation of IC operational and saturation voltages with epi resistivity, theckness and divice structure are studied and presented in graphic forms so that IC design engineers can utilize them.

  • PDF

Reliability on Accelerated Soft Error Rate in Static RAM of Thin Film Transistor Type (소프트 에러율에 대한 박막 트랜지스터형 정적 RAM의 신뢰성)

  • Kim Do-Woo;Wang Jin-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.507-511
    • /
    • 2006
  • We investigated accelerated soft error rate (ASER) in static random access memory (SRAM) cells of thin film transistor (TFT) type. The effects on ASER by cell density, buried nwell structure, operational voltage, and polysilicon-2 layer thickness were examined. The increase in the operational voltage, and the decrease in the density of SRAM cells, respectively, resulted in the decrease of ASER values. The SRAM chips with buried nwell showed lower ASER than those with normal well structure did. The ASER decreased as the test distance from alpha source to the sample increased from $7{\mu}m\;to\;15{\mu}m$. As the polysilicon-2 thickness increased up to $1000\;{\AA}$, the ASER decreased exponentially. In conclusion, the best condition for low soft error rate, which is essential to obtain highly reliable SRAM device, is to apply the buried nwell structure scheme and to fabricate thin film transistors with the thick polysilicon-2 layer

Potential Ruse as a function of the Buried Depth for Structure (구조체의 매설깊이에 따른 전위상승)

  • Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.27-28
    • /
    • 2006
  • This paper deals with an approach to the reduction of potential rise according to the buried depth of structure. In order to analyze the surface potential rise of structure, an electrolytic tank which simulates the semi-infinite earth has been used. The potential rise has been measured and analyzed for types of structure using an electrolytic tank experimental apparatus in real time. The structure models were designed through reducing real buildings and fabricated with two types on a scale of one-one hundred sixty When a test current flowed through structure models, the potential rise of outline frame type(structure model A) was more high than that of electric cage type(structure model B). The distributions of surface potential rise are dependent on the buried depth of structure model.

  • PDF

Bonding between high strength rebar and reactive powder concrete

  • Deng, Zong-Cai;Jumbe, R. Daud;Yuan, Chang-Xing
    • Computers and Concrete
    • /
    • v.13 no.3
    • /
    • pp.411-421
    • /
    • 2014
  • A central pullout test was conducted to investigate the bonding properties between high strength rebar and reactive powder concrete (RPC), which covered ultimate pullout load, ultimate bonding stress, free end initial slip, free end slip at peak load, and load-slip curve characteristics. The effects of varying rebar buried length, thickness of protective layer and diameter of rebars on the bonding properties were studied, and how to determine the minimum thickness of protective layer and critical anchorage length was suggested according the test results. The results prove that: 1) Ultimate pull out load and free end initial slip load increases with increase in buried length, while ultimate bonding stress and slip corresponding to the peak load reduces. When buried length is increased from 3d to 4d(d is the diameter of rebar), after peak load, the load-slip curve descending segment declines faster, but later the load rises again exceeding the first peak load. When buried length reaches 5d, rebar pull fracture occurs. 2) As thickness of protective layer increases, the ultimate pull out load, ultimate bond stress, free end initial slip load and the slip corresponding to the peak load increase, and the descending section of the curve becomes gentle. The recommended minimum thickness of protective layer for plate type members should be the greater value between d and 10 mm, and for beams or columns the greater value between d and 15 mm. 3) Increasing the diameter of HRB500 rebars leads to a gentle slope in the descending segment of the pullout curve. 4) The bonding properties between high strength steel HRB500 and RPC is very good. The suggested buried length for test determining bonding strength between high strength rebars and RPC is 4d and a formula to calculate the critical anchorage length is established. The relationships between ultimate bonding stress and thickness of protective layer or the buried length was obtained.