• Title/Summary/Keyword: Built-in current sensor

Search Result 74, Processing Time 0.025 seconds

Magnetic Field Properties About Core Change (코어 변화에 대한 자계 특성)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.

A design of BIST/BICS circuits for detection of fault and defect and their locations in VLSI memories (고집적 메모리의 고장 및 결함 위치검출 가능한 BIST/BICS 회로의 설계)

  • 김대익;배성환;전병실
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.10
    • /
    • pp.2123-2135
    • /
    • 1997
  • In this paepr, we consider resistive shorts on drain-source, drain-gate, and gate-source as well as opens in MOSFETs included in typical memory cell of VLSI SRAM. Behavior of memeory is observed by analyzing voltage at storage nodes of memeory and IDDQ(quiescent power supply current) through PSPICE simulation. Using this behavioral analysis, an effective testing algorithm of complexity O(N) which can be applied to both functional testing and IDDQ testing simultaeously is proposed. Built-In Self Test(BIST) circuit which detects faults in memories and Built-In Current Sensor(BICS) which monitors the power supply bus for abnormalities in quescent current are developed and imprlemented to improve the quality and efficiency of testing. Implemented BIST and BICS circuits can detect locations of faults and defects in order to repair faulty memories.

  • PDF

Design of a High Performance Built-In Current Sensor using 0.8$\mu\textrm{m}$ CMOS Technology (0.8$\mu\textrm{m}$ CMOS 공정을 이용한 고성능 내장형 전류감지기의 구현)

  • 송근호;한석붕
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.12
    • /
    • pp.13-22
    • /
    • 1998
  • In this paper, we propose a high-performance BICS(built-in current sensor) which is fabricated in 0.8${\mu}{\textrm}{m}$ single-poly two-metal process for IDDQ testing of CMOS VLSI circuit. The CUT(circuit under test) is 4-bit full adder with a bridging fault. Using two nMOSs that have different size, two bridging faults that have different resistance values are injected in the CUT. And controlling a gate node, we experimented various fault effects. The proposed BICS detects the faulty current at the end of the clock period, therefore it can test a CUT that has a much longer critical propagation delay time and larger area than conventional BICSs. As expected in the HSPICE simulation, experimental results of fabricated chip demonstrated that the proposed BICS can exactly detect bridging faults in the circuit.

  • PDF

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.

Robust Model Based Fault Detection of EPB System for Varying Temperature (온도변화에 강인한 EPB 시스템의 모델기반 고장검출 방법)

  • Moon, Byoung-Joon;Park, Chong-Kug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.26-30
    • /
    • 2009
  • In this paper, a robust model based fault detection for varying temperature is proposed, To develop a robust force estimation model, it needs temperature information because the force sensor's output is affected by a temperature variation. If an EPB system does not include a temperature sensor, the model has a much larger error than an EPB system with a built-in temperature sensor. Therefore, the temperature is estimated by using Ohm's law. The force model is applied with a motor current, battery voltage, operation mode, and the estimated temperature to detect a force sensor's abnormal signal fault. The residual is calculated by comparing the value of the measured force and the estimated force. Fault information is collected by using the output of the evaluated residual with the adaptive thresholds. A proposed robust model based fault detection for varying temperature was verified by HILS (Hardware in the Loop Simulation).

Smartphone racing game controller UX testing (스마트폰 레이싱 게임 조작기 UX 평가)

  • Chung, Donghun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.4
    • /
    • pp.143-154
    • /
    • 2015
  • This study aims to evaluate smartphone gaming controllers. Diffusion of smartphone makes its users to play smartphone games in ease and comfort and its built-in sensors deliver new gaming experience to the users. Based on the concept how the controller system is important, the current research also implies the importance of customizing service which gives users a selection to deploy a controller. To explore the interaction effect of controllers and customizing on interactivity, flow, usability, attitude, and intention, the research constructs 3(gyroscope, wheel, and button controllers) by 2(default and customizing setting) experimental design and forty college students played Gameloft's Asphalt 8: Airborne in a within subject design. The results showed that interaction effect and customizing main effect were not found, but controller main effect was statistically significant. Button controller is superior to those other two in more detail. It implies that it is still not useful to play new types of gaming controller, and a customizing service. It suggests that smartphone games should more focus on improving optimal user experience with built-in sensor controllers.

Development of Location Estimation and Navigation System of Mobile Robots Using USN and LEGO Mindstorms NXT (USN과 LEGO Mindstorms NXT를 이용한 이동로봇의 위치 인식과 주행 시스템 개발)

  • Park, Jong-Jin;Chun, Chang-Hi
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.215-221
    • /
    • 2010
  • This paper introduces development of location estimation and navigation system of mobile robots using USN and LEGO Mindstorms NXT. Developed system includes location estimation, location and navigation information display and navigation control parts. It used ZigBee based USN which was built with CC2431 chip to locate blind node and implemented fuzzy model to improve ability of calculation of distances from reference nodes and location of mobile robots. This paper proposed combination method of location estimation using USN and encoder which is built in motors of mobile robots. Experimental results showed proposed method is superior to the method which used USN only in location estimation and navigating robots. Developed system can locate current position of mobile robots and monitor information from sensor nodes like temperature, humidity and send control signal to mobile robot to move.

Design and Fabrication of a Conductively Cooled Cryostat by Cryocooler (냉동기 부착형 전도냉각식 Cryostat의 설계 및 제작)

  • Bae, Joon-Han;Sim, Ki-Deck
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1921-1924
    • /
    • 2007
  • In order to measure the superconducting transition temperature, the critical current and the alternating current(AC) loss on short samples of high temperature superconductor, a cryocooler cooled cryostat has been designed and built. Two closed-cycle coolers provide cooling with an ultimate sample temperature below 16K. Temperature regulation is provided by 50W of electrical heater that opposes the cooling power from the cold heads. Temperature control feedback is by means of a cernox temperature sensor co-located with the heaters on the second stage of the cold head. Additional temperature sensors are located on the sample mount(B1), on the CVI cold head(B2) and on the Dakin cold head(B3). AC losses on the sample high temperature superconductor were measured at 30K so that the developed device performance was evaluated. In this paper, the design, fabrication and test results on the cryocooler cooled cryostat are presented.

Development of Deterioration Detecting System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화검출시스템 설계)

  • Kim, Sung-Duck;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.232-235
    • /
    • 2000
  • Design and experiments of a nondestructive system to inspect deterioration of ACSR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wire usually used in HV overhead distribution lines presented in this paper. ACSR-OC conductor built to pollutants air for a long period would be easily progress to corrode so that it may lead to the reduction of the effective cross section area of conductors. A fault diagnosis system consisting of a solenoid sensor, a constant current source with RF frequency signal processing unit and a motor driver/controller designed and implemented. This instrument can dot the sensor output variation due to deterioration corrosion, continuously. As a result, it was shown such corrosion detector can readily be utilized estimating the diameter change due to deterioration overhead distribution lines and in giving an warning or inform before severe aged conductor lead to fail.

  • PDF

Static Performance Diagnosis Based on Pressure Signal for a Flow Control Servovalve or Proportional Direction Valve (유량제어용 서보밸브와 비례방향밸브의 압력신호를 이용한 정적 성능 진단에 관한 연구)

  • Kim, S.D.;Jeon, S.H.;Kim, I.D.;Ham, Y.B.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.32-41
    • /
    • 2012
  • Most diagnosis methods for servo valves requires installing spool displacement sensor or flow sensor as well as pressure sensor. The measurement of flow is hard to implement and many kinds of servovalves or proportional direction valves do not have a built-in spool displacement sensor. In this study, static performances of servovalve or proportional-direction-valve are studied theoretically and a diagnosis technique, which uses only load pressure and input current signal, is assessed. An experimental setup was made based upon a personal computer and the LabVIEW graphical language. A series of diagnosis tests were performed and the analysis results showed it possible to measure the pressure gain, hysteresis and null bias in a relatively simple methodology.