Magnetic Field Properties About Core Change  

Kim, Ki-Joon (Department of Mechatronics Engineering, University of Incheon)
Publication Information
Journal of the Korean Institute of Electrical and Electronic Material Engineers / v.25, no.2, 2012 , pp. 159-164 More about this Journal
Abstract
In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.