• 제목/요약/키워드: Building regulation

검색결과 385건 처리시간 0.029초

국내외 표준 시방서의 거푸집 및 동바리 시공.해체 관련 규정의 비교 (Comparison of Prescription Regarding Form Work in Standard Specifications among Domestic and Foreign Countries)

  • 전규남;최성용;노상균;백대현;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.195-198
    • /
    • 2009
  • In this paper, regulation for form work in standard specification among Korea and foreign countries are studied and compared. Within the scope of this paper, regulation regarding fabrication of form and form removal are mainly focused on. Standard specification prescribed by construction temporary equipment association provides detailed regulations and well arranged. ACI 347-04, CEB-FIP and BS EN 13670 had different style and scope compared to domestic specification. Especially, regulation for form removal in ACI prescribed in terms of minimum period.

  • PDF

우리나라 피난방화규정의 제.개정시기별 화재안전성능 평가 - 호텔건물을 중심으로 - (A Study on Evaluating the Fire Safety of the Regulation of Escape and Fire-Prevention from Enacting to Now - Focusing on the Hotel Building -)

  • 이세명;윤명오
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.28-41
    • /
    • 2011
  • 우리나라의 피난방화규정은 1962년 건축법 제정 이후 현재에 이르기까지 많은 변화를 겪어 왔다. 그러나, 과거에 비해 화재안전성능이 어느 정도 개선되었는지, 그리고 현재의 규정은 어느 정도의 화재안전성능을 확보하고 있는지에 대한 정량적인 평가가 이루어지지 않고 있다. 이 연구에서는 과거 화재사례로 비추어 화재발생시 인명피해가 높을 것으로 예상되는 숙박시설 중 호텔건물을 모델로 하여 피난방화규정의 제/개정 시기별 화재안전성능을 평가해 보았다. 그 결과 과거에 비해 화재안전성능이 개선되고는 있으나, 특히 저층부분에서의 거실 및 층피난안전성에서 취약함을 확인할 수 있었다. 숙박시설의 경우 재실자의 화재 인지가 늦어 피난시간이 상대적으로 지연되는 문제점이 있기 때문에, 내부마감재료와 방화문 그리고, 방화구획(면적별/층별) 등의 규정을 보완하여 연기층하강시간을 지연시킬 수 있는 현실적인 방안을 마련 할 필요가 있다.

건물 지하층에 설치된 자가발전기실의 환기제어 모델 시스템에 관한 연구 (A Ventilation Control Model System of Standby Generating Room Installed in Basement of Building)

  • 홍원표;강병권
    • 조명전기설비학회논문지
    • /
    • 제14권2호
    • /
    • pp.75-82
    • /
    • 2000
  • 대전지역의 자가발전시스템의 20 개소의 실태조사의 분석자료을 통하여 자가발전기실의 환기시스템의 문제점을 파악하고 이와 관련된 국내외 관련 법규플 조사.비교 분석한 자료를 토대로 다이젤구동형 자가발전기실의 환기시스템의 이론해석 및 새로운 환기제어방식을 제안하였다.

  • PDF

Green Buildings to Sustain California's Central Valley

  • Yupeng Luo;Geoffrey S. Becker
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.42-46
    • /
    • 2013
  • California's heartland, the Great Central Valley, is one of the most productive agricultural regions in the world. However for many years the valley has been struggling with a broad range of social, economic, and environmental challenges. Some significant concerns include water resources, air pollution, poverty rates, housing issues, etc. Another strike against the valley is the relative reluctance to embrace widespread sustainable building practices. This paper discusses the long-term and profound impact of the built environment has on the aforementioned socioeconomic and environmental issues facing the valley. It reviews exemplary practices in other states and regions regarding policy-making and regulation in the building industry as well as sustainable community development. The paper further explores viable options specifically for the Fresno metropolitan area (the largest in the Central Valley) to combat its unique multifaceted challenges.

  • PDF

창호 및 벽체의 단열성능에 따른 건물에너지효율등급 평가 연구 -공동주택을 중심으로- (A Study on the Evaluation of Building Energy Rating considering the Insulation Performance of the Window and Wall in Apartment Houses)

  • 김치훈;안병립;김지연;장철용
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.608-613
    • /
    • 2009
  • According to the building regulation U-value limitation of window is $3.3W/m^2{\cdot}K$ in southern regions, while U-value limitation of wall is $0.35{\sim}0.58W/m^2{\cdot}K$. It means that the energy loss through windows is five times more than it through wall. Therefore, this study analyze how much it has affected building energy rating when the insulation performance of windows and walls is changed by building regulation. In conclusion, in order to obtain 2 rating thermal performance of windows is improved more than 10 percent of U-value limitation and it of wall is improved more than 20 percent. The thermal performance of windows is improved more than 20 percent of U-value limitation and it of wall is improved more than 30 percent to receive 1 rating.

  • PDF

각형 강관기둥부재의 한계온도 평가 연구 (Evaluation of Limiting Temperatures of Rectangular Hollow Sections)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.331-332
    • /
    • 2012
  • Structural steel has been used as a primary materials to columns and beams since 1960's in Korea with an advantages of excellent of load-bearing capacity and design flexibility, and faster construction. However, if the steel columns made of structural steel exposed to fire the load-bearing capacity is going down steadily and finally reach to collapse. Therefore, building regulation requires fire resistance according to building occupation, scales. The fire resistance can be evaluated two categories. One is prescriptive method that is based on building regulation, specification and so on and the other is performance-based fire engineering method. The latter can be designed based on scientific and engineering consequences. The easiest evaluation way using the fire engineering design is comparing to the limiting temperature and maximum temperature calculated based on heat transfer theory. If the limiting temperature of a column exceeds the maximum temperature of it, the column can carry the load during the fire. Therefore, the database of limiting temperature is very essential for evaluation of column. In this paper, to build the database of column made of rectangular hollow sections 8 fire tests with loading were conducted and the relation between the limiting temperature and the applied loads showed in reverse proportion.

  • PDF

공동주택 향별 창면적비 변화에 따른 에너지 영향도 분석 (An Effect of the Change of Orientation and Window Area Ratio upon Building Energy Requirement in Apartment Housings)

  • 김재문;이규철;이승규;김민성;민준기
    • KIEAE Journal
    • /
    • 제13권2호
    • /
    • pp.21-26
    • /
    • 2013
  • Due to the increasing concerns about the buildings which have affected the global environment, most countries have enacted a regulation for the sustainability of domestic buildings. In 2008, the Korean government started to enact a regulation of apartment and office buildings for energy saving. Many research on the sustainable apartment building focuses on $84m^2$ or larger type in response to market demand; therefore, small size type such as $46m^2$ type needs to be researched. In addition, the research on the orientation and window to wall ratio of the building have been separately studied as a means of energy reduction; therefore, the research on correlation of the orientation and window to wall ratio hasn't been fully explored yet. This paper analyzes the energy demand of the apartment building as the change of orientation and window to wall ratio among $46m^2$ and $84m^2$ type. In conclusion, when reducing the window to wall ratio, energy demand was reduced, except when the orientation of the building was between from +10 to -20 from the south.

고속선의 새로운 국제안전규칙 -화재안전규칙에 대하여- (International Code of Safety Regulation for High Speed Craft - as compared with Fire Safety Regulation-)

  • 박영규;신영식
    • 해양환경안전학회지
    • /
    • 제3권1호
    • /
    • pp.111-123
    • /
    • 1997
  • The application of all regulations during building phase, plus constant vigilance in operation is essential to reducing the risk of fire aboard. A Safety by design approach is increasingly important. Fire safety regulation can solve problems which are hard to be solved by HSC code(International Code of Safety for High Speed Craft). Recently HSC code is applied for ship design development or guidance to the designer and demonstrates many advantages. In this pages, ship fire Safety are realistically modeled as ship design and the shipboard fires & muster stations are analyzed using HSC Code.

  • PDF

지붕재 일체형 태양전지 모듈의 개발에 따른 내구성 평가 (조립식 건축시스템을 중심으로) (A Study on the Development of Roof Integrated PV Module (Focused on the Prefab Building System))

  • 이소미;노지희;이응직
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.17-24
    • /
    • 2006
  • The application of photovoltaics into building as integrated building components has been paid more attention worldwide. Photovoltaics or solar electric modules are solid state devices, directly converting solar radiation into electricity; the process does not require fuel and any moving parts, and produce no pollutants. And the prefab building method is very effective because the pre- manufactured building components is simply assembled to making up buildings in the construction fields especially the sandwich panel. Architecture considerations for the integration of PV module to building envelope such as building structure, construction type, safety, regulation, maintenance etc. have been carefully refelected from the early stage of BIPV module design. Trial product of BIPV module are manufactured and sample construction details for demonstration building are purposed. Therefore, this paper intends to advanced its practical use by proposing how to get integrated PV system which can be applied to prefab building material, and how to apply it.