• Title/Summary/Keyword: Buccal

Search Result 1,227, Processing Time 0.041 seconds

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER (3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구)

  • Lee, Jong-Beom;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.643-652
    • /
    • 2006
  • The purpose of this study was to elucidate the size and morphologic characteristics of maxillary primary first molars in Korean children using three-dimensional laser scanner and compare three-dimensional image with preformed stainless steel crown. Scanned three-dimensional images of dental cast taken from 132 children(male 62, female 70) by three-dimensional laser scanner(Breuckmann opto-Top HE100, INUS, Korea) were used. Mesiodistal diameter, buccolingual diameter, occlusogingival height and crown shape of each image were calculated by Rapidform 2004 program(INUS, Korea). The values were statistically compared by independent samples t-test with 95% of significant level. The results were as follows : 1. No significant difference in crown size was found between left and right maxillay primary first molar(p>0.05). 2, Significant difference in mesiodistal diameter, buccolingual diameter, buccal occlusogingival height was found between male and female (p<0.05), and crown size of male was bigger than that of female. 3. Average image of maxillay primary first molar was shaped three-dimensionally and measured. In comparison with 3M stainless steel crown, this image was similar with No.4 or No.5 SS crown in male, No.4 in female. In comparison with ILSUNG SS crown, this image was similar with No.5 in male, No.4 in female. 4 Mesiolingual line angle area, distolingual line angle area and buccogingival ridge were more obvious in average image than 3M stainless steel crown. ILSUNG SS crown was more square and had longer mesiodistal diameter than average 3D image.

  • PDF

INFLUENCE OF A SODIUM HYPOCHLORITE GEL ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS (차아염소산 나트륨의 사용이 복합레진 수복물의 미세누출에 미치는 영향)

  • Yang, Kye-Sik;Kim, Dae-Eop;Lee, Kwang-Hee;Jeong, Young-Nam
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • This study evaluated the influence of chemomechanical caries removal agent $Carisolv^{TM}$(MediTeam, Sweden) for composite resin adhesion to sound human permanent and primary dentin. The buccal/labial surfaces of 80 permanent molars and 80 primary incisors were used. Four types of adhesives and one composite resin were used; AQ Bond(Sun Medical, Japan), Clearfil SE Bond(Kuraray, Japan), Single Bond(3M, USA), Scotchbond Multi-Purpose(3M, USA) and Z100(3M, USA). One drop of $Carisolv^{TM}$(MediTeam, Sweden) was pretreated on the dentin for 0 second(control) and 60 seconds. The specimens were thermocycled for 1,000 times in baths kept 5 degrees C and 55 degrees C with a 30 seconds dwell time. Shear bond strengths were tested and the data was statistically analyzed using one-way ANOVA with subsequent post hoc Scheffe test at p<0.05. $Carisolv^{TM}$ treatment significantly decreased the shear bond strength. Shear bond strength of permanent dentin was significantly higher than that of primary dentin. Clearfil SE Bond treatment groups showed the highest shear bond strength and AQ Bond treatment groups showed the lowest shear bond strength.

  • PDF

THE EFFECT OF REBONDING IN MICROLEAKAGE OF CLASS V RESTORATIONS UNDER LOAD CYCLING (부하순환 하에서 제V급 복합레진 수복물의 미세변연누출에 대한 재접착제의 효과에 관한 연구)

  • Youn, Yeon-Hee;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.527-533
    • /
    • 2004
  • One clinical technique recommended for improving marginal integrity is "rebonding" or application of unfilled resins to the surface of composite restoration. But continuously the restorations are affected with occlusal load. There is room for doubt that the rebonding agent has the positive effect on microleakage in spite of the stress generated by the occlusal load. This study determined the effect of rebonding on microleakage of Class V resin composite restorations under load cycling. Class V cavities were prepared on the buccal surface of 40 sound extracted premolars and restored with a hybrid light-cured resin composite according to manufacturers' directions. They were randomly divided into two groups consisting of 20 samples: a control(group I), without surface sealing, and the other group(group II) in which margins were etched and rebonded. After thermocycling, each of groups was divided into subgroups(group A, B), and load cycling(total 100,000 cycles with 4-100N load at a rate of 1 Hz) were applied on the group B. Assessment of microleakage utilized methylene blue dye penetration. The following results were obtained: 1. In the occlusal region, no significant difference was noted in the scores regardless of whether or not the rebonding agent was used(group TA-IIA, IB-IIB)(p>0.05). 2. In the cervical region, the control group with rebonding(group IIA) showed the better result than the group without rebonding(group IA)(p<0.05). 3. In the cervical region, the rebonded group with load cycling(group IIB) showed similar results to the group without rebonding(group IB) and no significant difference was noted(p>0.05).

  • PDF

MICROLEAKAGE TEST ACCORDING TO ACID ETCHING TREATMENT IN CLASS V COMPOMERS (치면 산처리가 V급 와동의 compomer 수복에서 미세누출에 미치는 영향)

  • Moon, Sang-Hee;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.351-360
    • /
    • 2000
  • The purpose of this study was to evaluate the microleakage of class V compomers according to acid etching treatment and treatment times. Extracted 180 sound human molar teeth were selected then prepared physiologic pulpal pressure far this experiment. In this study class V cavities were prepared on buccal surface with gingival margin located in 1mm superior to CEJ under simulate physiological conditions. These specimens were randomly divided into 6 groups of 30 each and restored following methods : A: Dyract AP + Prime&Bond 2.1 Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1. Group 3 : 30 seconds acid etching and same method with Group 1. B: F2000 groups + Single Bond adhesive Group 1 : No acid etching, according to manufacturer's instruction. Group 2 : 15 seconds acid etching and same method with Group 1 Group 3 : 30 seconds acid etching and same method with Group 1. After 500 thermocycling between $5^{\circ}C\;and\;55^{\circ}C$, the specimens were sealed with glass ionomer and nail varnish then placed in 5% methylene blue dye for 5 hours and rinsed with tab water. The specimens were embedded in orthodontic clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimens were then observed with a stereomicroscope at $\times20$ magnification. The results of this study were statistically analyzed using the indepedent sample t-test and analysis of variance. Results were as follows, 1. In occlusal walls, microleakage were significantly reduced in acid etched group restored with Dyract AP but no statistically significance in F2000 groups. 2. In gingival walls, microleakage were significantly reduced in group 2 restored with Dyract AP, and group 2 and group 3 in F2000 groups. 3. All groups, except group 3 in Dyract AP, showed significantly less microleakage in occlusal wall than gingival wall. 4. No statistical significance were showed between group 2 and group 3 in both materials.

  • PDF

MARGINAL LEAKAGE OF COMPOSITE RESIN AND COMPOMER RESTORATIONS CURED WITH THREE DIFFERENT LIGHT SOURCES (광중합기 종류에 따른 복합레진과 콤포머의 미세누출에 관한 연구)

  • Park, Chang-Hoo;Yang, Kyu-Ho;Kim, Seon-Mi;Choi, Nam-Ki
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.3
    • /
    • pp.438-446
    • /
    • 2006
  • The purpose of this study was to evaluate the microleakage of composite resin($Z250^{(R)}$) and compomer(Dyract AP) cured with various curing lights(Elipar $TriLight^{(R)}$, $Flipo^{(R)}$, and Elipar FreeLight $2^{(R)}$). Box-shaped class V cavities were prepared on the buccal and lingual surfaces of extracted human third molars. The sectioned specimens were evaluated for dye penetration and following results were obtained. 1. Regarding microleakage in the enamel margin with different curing light sources, there was no significant difference in Dyract AP whereas $Z250^{(R)}$ with $Flipo^{(R)}$ showed higher microleakage score than those of FreeLight $2^{(R)}$ or $TriLight^{(R)}$(p<0.05). 2. Regarding microleakage in the dentin margin with curing light sources, there were no significant differences in both Dyract AP and $Z250^{(R)}$(p>0.05). 3. Regarding microleakage in the enamel margin with filling materials. there were no significant differences in both filling materials with $Flipo^{(R)}$ whereas $Z250^{(R)}$ showed less microleakage than Dyract AP with FreeLight $2^{(R)}$ or $TriLight^{(R)}$ (p<0.05). 4. Regarding microleakage in the dentin margin with filling materials, there wer no significant differences in both filling materials with $TriLight^{(R)}$ whereas $Z250^{(R)}$ showed less microleakage than Dyract AP with FreeLight $2^{(R)}$ or $Flipo^{(R)}$ (p<0.05). 5. Enamel margin showed less microleakage than dentin margin when filled with Dyract AP and cured with $Flipo^{(R)}$ or FreeLight $2^{(R)}$ (p<0.05), but there were no statistically significant differences between the enamel and the dentin in the rest groups. This study suggested that $Z250^{(R)}$ showed lower microleakage score than Dyract AP. and that $Flipo^{(R)}$ showed higher microleakage score than FreeLight $2^{(R)}$ and $TriLight^{(R)}$ in the enamel margin filled with $Z250^{(R)}$.

  • PDF

REMINERALIZATION EFFECT OF COMMERCIALLY AVAILABLE ANTICARIOGENIC PRODUCTS ON ARTIFICIAL CARIES LESION USING QLF (QLF를 이용한 항우식 제품의 인공우식 재광화 효과에 대한 연구)

  • Song, Ju-Hyun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Kim, Chong-Chul;Hahn, Se-Hyun;Lee, Sang-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.2
    • /
    • pp.287-296
    • /
    • 2008
  • The purpose of this in vitro study was to compare the remineralization effect of commercially available anticariogenic products, exactly low level fluoride mouthrinse(500 ppm NaF), tooth cream with Casein phosphopeptide-amorphous calcium phosphate(CPP-ACP) and fluoride mouthrinse plus tooth cream on artificial caries lesion. Artificial caries lesion was induced at the buccal surface of permanent third molar and the specimens were then divided(16 specimens/group) into four group. Twice a day during 28 days specimens of each group were treated with a commercially anticariogenic product as follows and applied to the pH cycling system. Group 1: control group (No treatment) Group 2: Tooth $Mousse^{(R)}$ (GC Co. Japan) Group 3: $chikachika^{(R)}$ (Samil Co. Korea) Group 4: $chikachika^{(R)}$+Tooth Mousse$^{(R)}$ The long-term change of mineral loss(${\Delta}Q$) was evaluated by quantitative light-induced fluorescence (QLF) and the following results were obtained: 1. ${\Delta}Q$ of Group 1 was not noticed statistically significant during 28 days comparing that prior to treatment. There was a statistically significant increase in ${\Delta}Q$ of Group 2 and 3 since 14 days. So was in ${\Delta}Q$ of Group 4 since 7 days. 2. ${\Delta}Q$ was increased as follows: Group 1< Group 2, 3< Group 4. 3. Comparing with Group 1, Group 2 was a statistically significant increase since 7 days and Group 3 and 4 were since 3 days. Comparing Group 2 with 3, there was not noticed statistically significant during whole duration. Group 4 was significantly higher than Group 2 and 3 after 28 days. 4. All groups demonstrated a decrease in the rate of remineralization as time goes on.

  • PDF

Effect of Mouthguard on Tooth Distortion During Clenching (이악물기 시 발생되는 치아변형에 대한 구강보호장치의 역할)

  • Lee, Yun;Choi, Dae-Gyun;Kwon, Kung-Rock;Lee, Richard Sung-Bok;Noh, Kwan-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.405-417
    • /
    • 2010
  • Previous studies have already shown that mouthguard is effective in protecting jaw bone, teeth and oral tissue against sports trauma. However, other than severe trauma, repetitive force, such as disorders like clenching, cause teeth or oral tissue damage. These kinds of disorders usually present pathologic attrition in the posterior teeth, resorption in alveolar bone, loss of teeth and destruction of occlusion. Wearing a mouthguard is believed to be effective in preventing these disorders. But its effect is not examined thoroughly enough. The purpose of this study is to identify whether mouthguard is effective in reducing strain caused by clenching. Mandibular first molars in the normal occlusal relationship without any history of dental treatment were chosen. Biaxial type strain gauge was placed on the buccal surface of the tooth. Having maximum occlusal force, measured by load cell, as a standard, clenching intensity were divided into three stages; moment of slightly tooth contact, medium bite force (50% of maximum bite force), maximum bite force. Strain occurring in dentition in each stage with and without mouthguard was measured. Changes in strain (on dentition) between each stage and difference in strain, between with or without mouthguard were recorded by PCD-300 analyzer and PCD-30 soft ware. The data was statistically analyzed by Wilcoxon signed rank test. The following results were drawn; Without mouthguard, strain given on dentition increased as the clenching force increased. With mouthguard, strain given on dentition also increased as the clenching force increased. With mouthguard, strain decreased, in all cases of clenching force stages. Data on the moment of slightly tooth contact stage, had no statistical significance. However, with mouthguard, 50-90% of decrease in strain could be obtained in maximum occlusal force, compared to the group without mouthguard. Mouthguard decreased the strain on the dentition, caused by clenching. Therefore, mouthguard seems to be effective in preventing damage on dentition, by acting against clenching, which occurs both consciously and unconsciously during sports activities.

Finite-element analysis of the shift in center of resistance of the maxillary dentition in relation to alveolar bone loss (치조골 상실에 따른 상악 치아군 저항중심의 변화에 관한 유한요소해석)

  • Sung, Sang-Jin;Kim, In-Tai;Kook, Yoon-Ah;Chun, Youn-Sic;Kim, Seong-Hun;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.39 no.5
    • /
    • pp.278-288
    • /
    • 2009
  • Objective: The aim of this study was to investigate the changes in the center of resistance of the maxillary teeth in relation to alveolar bone loss. Methods: A finite element model, which included the upper dentition and periodontal ligament, was designed according to the amount of bone loss (0 mm, 2 mm, 4 mm). The teeth in each group were fixed with buccal and lingual arch wires and splint wires. Retraction and intrusion forces of 200 g for 4 and 6 anterior teeth groups and 400 g for the full dentition group were applied. Results: The centers of resistance were at 13.5 mm, 14.5 mm, 15 mm apical and 12 mm, 12 mm, 12.5 mm posterior in the 4 incisor group; 13.5 mm, 14.5 mm, 15 mm apical and 14 mm, 14 mm, 14.5 mm posterior in the 6 anterior teeth group; and 11 mm, 13 mm, 14.5 mm apical and 26.5 mm, 27 mm, 25.5 mm posterior in the full dentition group respectively according to 0 mm, 2 mm, 4 mm bone loss. Conclusions: The center of resistance shifted apically and posteriorly as alveolar bone loss increased in 4 and 6 anterior teeth groups. However, in the full dentition group, the center of resistance shifted apically and anteriorly in the 4 mm bone loss model.

AN ANATOMICAL STUDY OF THE MANDIBULAR RAMUS IN KOREAN PATIENTS WITH DENTOFACIAL DEFORMITY (한국인 악안면 기형환자의 하악골 상행지에 관한 해부학적 연구)

  • Kim, Gi-Jung;Lee, Eui-Wung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.193-203
    • /
    • 2001
  • Orthognathic surgery of the mandibular prognathism and the retrognathism is tend to be performed on the mandibular ramus to prevent inferor alveolar nerve injuries. The purpose of this study is to find a safe and accurate reference point on mandibular ramus for orthognathic surgery by comparative anatomical study of dentofacial deformity patients. We use 38 Korean Cadavers with normal occlusion(Group 1), 3-dimensional simulation of computerized tomogram of 23 patients with retrognathism (Group 2), 27 patients with mandibular prognathism (Group 3). Following results are obtained : 1. The maximum thickness of the mandibular ramus is $8.78{\pm}1.15mm$ for Group 2, $7.61{\pm}1.26mm$ for Group 1, $6.95{\pm}0.82mm$ for Group3 respectively (P=0001). The minimum thickness is $5.51{\pm}1.08mm$ for Group 1, $5.06{\pm}0.40mm$ for Group 2, $4.56{\pm}0.78mm$ for Group3, respectively (p=0.0001). But, the thickness at the level of 5mm above the lingular is $0.78{\pm}0.65mm$ for Group 2, $5.63{\pm}1.28mm$ for Group 1, $5.32{\pm}0.91mm$ for Group 3, respectively. There is no significant difference between these groups(P=0.0510). 2. The horizontal location from the midwaist point to lingular is $0.18{\pm}1.57mm$ for Group 1, $0.69{\pm}1.33mm$ for Group 2, $0.66{\pm}1.66mm$ for Group 3, and there is no significant difference between these groups(p=0.0835). But the vertical location from the midwaist point to lingular is $1.45{\pm}2.64mm$ for Group 1, $0.63{\pm}1.44mm$ for Group 2, $0.34{\pm}1.81mm$ for Group 3, and there is significant difference between these groups(p=0.0030). 3. The horizontal location from the midwaist point to mandibular foramen is $0.29{\pm}1.75mm$ for Group 1, $0.63{\pm}1.44mm$ for Group 2, $0.34{\pm}1.81mm$ for Group 3, and there is no significant difference between these groups(p=0.5403). But the vertical location from the midwaist point to mandibular foramen is $-3.33{\pm}4.43mm$ for Group1, $-4.79{\pm}2.26mm$ for Group 2, $-6.06{\pm}2.99mm$ for Group 3, and there is significant difference between these groups(P=0.0001). 4. The horizontal length from the disto-buccal cusp tip of mandibular second molar to lingula is $30.97{\pm}4.17mm$ for Group 3, $28.29{\pm}2.65mm$ for Group 1, $25.48{\pm}0.77mm$ for Group 2 (p=0.0000), and also vertical length is $7.72{\pm}3.22mm$ for Group 3, $6.38{\pm}1.83mm$ for Group 1, $5.89{\pm}2.30mm$ for Group 2 (P=0.0014). 5. The location of lingular is 0.50 from anterior border of mandibular ramus in all groups, if it assumed the length from anterior border to posterior border is 1. And it is almost 0.33 from the sigmoid notch, if it assumed the length from sigmoid notch to antegonial notch is 1. 6. In Group 1, Antilingular prominence is located on ($1.12{\pm}1.43mm,\;4.01{\pm}2.36mm$) from the midwaist point, and there is no correlation between antilingular prominence and lingular, mandibular foramen.

  • PDF