• Title/Summary/Keyword: Bubble test

Search Result 206, Processing Time 0.024 seconds

Perceptions of Turkish University Students about the Effects of Water Pipe Smoking on Health

  • Sahin, Sevil;Cinar, Nursan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4615-4621
    • /
    • 2015
  • Background: The popularity of the water pipe, also referred to as hookah, narghile, shisha or hubble-bubble, has increased tremendously during the past few decades. This study was conducted to determine student water pipe smoking status and perceptions about the effects of water pipe smoking on health in a state university in Ankara. Materials and Methods: This cross-sectional study was conducted between September 2014 and January 2015. The data were collected with a questionnaire and "The Scale of Perception about the Effects of Water Pipe Smoking on Health". The data obtained were evaluated in IBM SPSS (version 20.0) statistical package program in computer. One-way analysis of variance (ANOVA) was used for the analyses by checking homogeneity of variances and Student's t-test. Values of p<0.05 were considered statistically significant. Results: The total mean score obtained by young people who took part in the study was determined as ($\bar{X}=65.20{\pm}1.25$, min=33, max=75). Upon comparison of the total mean scores obtained by young people from the Scale of Perception about the effects of water pipe smoking on health and gender variable, the scores obtained by the females students were higher than those of the male students with a statistically significant difference (t=7.525, p<0.05). A statistically significant difference was observed between the total mean scores obtained by young people with cigarette and water pipe smoking status (for each, t=-3.731, p<0.05; t=-13.987, p<0.05). Conclusions: In conclusion, university students have wrong knowledge on the dangers of water pipe smoking. There was a high prevalence of using water pipes among university students. Gender significantly affected the perceptions about the effect of water pipe smoking on health in our sample.

Boiling Heat Transfer Coefficients of Nanofluids Using Carbon Nanotubes (탄소나노튜브를 적용한 나노유체의 비등 열전달계수)

  • Lee, Yo-Han;Jung, Dong-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.35-44
    • /
    • 2009
  • In this study, boiling heat transfer coefficients(HTCs) and critical heat flux(CHF) are measured on a smooth square flat copper heater in a pool of pure water with and without carbon nano tubes(CNTs) dispersed at $60^{\circ}C$. Tested aqueous nanofluids are prepared using multi-walled CNTs whose volume concentrations are 0.0001, 0.001, 0.01, and 0.05%. For dispersion of CNTs, polyvinyl pyrrolidone(PVP) is used in distilled water. Pool boiling HTCs are taken from $10kW/m^2$ to critical heat flux for all nanofluids. Test results show that the pool boiling HTCs of the nanofluids are lower than those of pure water in entire nucleate boiling regime. On the other hand, critical heat flux is enhanced greatly showing up to 200% increase at volume concentration of 0.001% CNTs as compared to that of pure water. This is related to the change of surface characteristics by the deposition of CNTs. This deposition makes a thin CNT layer on the surface and the active nucleation sites of heat transfer surface are decreased due to this layer. The thin layer acts as the thermal resistance and also decreases the bubble generation rate resulting in a decrease in pool boiling HTCs. The same layer, however, maintains the nucleate boiling even at very high heat fluxes and reduces the formation of large vapor canopy at near CHF resulting in a significant increase in CHF.

Effect of Relative Position of Vane and Blade on Heat/Mass Transfer Characteristics on Stationary Turbine Blade Surface (베인과 블레이드 사이의 상대위치 변화에 따른 터빈 블레이드 표면에서의 열/물질전달 특성)

  • Rhee, Dong-Ho;Cho, Hyung Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.27-38
    • /
    • 2005
  • The present study investigated the effect of relative position of the blade on blade surface heat transfer. The experiments were conducted in a low speed wind tunnel with a stationary annular turbine cascade. The test section has a single turbine stage composed of sixteen guide vanes and blades. The chord length of the blade is 150 mm and the mean tip clearance of the blade is $2.5\%$ of the blade chord. The Reynolds number based on blade inlet velocity and chord length is $1.5{\times}105$ and mean turbulence intensity is about $3\%$. To investigate the effect of relative position of blade, the blade at six different positions in a pitch was examined. For the detailed mass transfer measurements, a naphthalene sublimation technique was used. In general, complex heat transfer characteristics are observed on the blade surface due to various flow characteristics, such as a laminar flow separation, relaminarization, flow acceleration, transition to turbulence and tip leakage vortices. The results show that the blade relative position affects those heat transfer characteristics because the distributions of incoming flow velocity and turbulence intensity are changed. Especially, the heat transfer pattern on the near-tip region is significantly affected by the relative position of the blade because the effect of tip leakage vortex is strongly dependent on the blade position. On the pressure side, the effect of blade position is not so significant as on the suction side surface although the position and the size of the separation bubble are changed.

Experimental Investigations on Upper Part Load Vortex Rope Pressure Fluctuations in Francis Turbine Draft Tube

  • Nicolet, Christophe;Zobeiri, Amirreza;Maruzewski, Pierre;Avellan, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.179-190
    • /
    • 2011
  • The swirling flow developing in Francis turbine draft tube under part load operation leads to pressure fluctuations usually in the range of 0.2 to 0.4 times the runner rotational frequency resulting from the so-called vortex breakdown. For low cavitation number, the flow features a cavitation vortex rope animated with precession motion. Under given conditions, these pressure fluctuations may lead to undesirable pressure fluctuations in the entire hydraulic system and also produce active power oscillations. For the upper part load range, between 0.7 and 0.85 times the best efficiency discharge, pressure fluctuations may appear in a higher frequency range of 2 to 4 times the runner rotational speed and feature modulations with vortex rope precession. It has been pointed out that for this particular operating point, the vortex rope features elliptical cross section and is animated of a self-rotation. This paper presents an experimental investigation focusing on this peculiar phenomenon, defined as the upper part load vortex rope. The experimental investigation is carried out on a high specific speed Francis turbine scale model installed on a test rig of the EPFL Laboratory for Hydraulic Machines. The selected operating point corresponds to a discharge of 0.83 times the best efficiency discharge. Observations of the cavitation vortex carried out with high speed camera have been recorded and synchronized with pressure fluctuations measurements at the draft tube cone. First, the vortex rope self rotation frequency is evidenced and the related frequency is deduced. Then, the influence of the sigma cavitation number on vortex rope shape and pressure fluctuations is presented. The waterfall diagram of the pressure fluctuations evidences resonance effects with the hydraulic circuit. The influence of outlet bubble cavitation and air injection is also investigated for low cavitation number. The time evolution of the vortex rope volume is compared with pressure fluctuations time evolution using image processing. Finally, the influence of the Froude number on the vortex rope shape and the associated pressure fluctuations is analyzed by varying the rotational speed.

Effect of Stabilizers on Performance of Electroluminescence Display Device (안정화제가 무기 전계발광 디스플레이 소자 성능에 미치는 영향)

  • Shin, DongHyuk;Lim, JongChoo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.356-363
    • /
    • 2007
  • The stability of paste solutions for electroluminescence display(ELD) device was found to be greatly affected by kind and dosage of a stabilizer used. The stabilizer Disperbyk-180 showed the best stability performance against phosphor paste solutions among the stabilizers used during this study. The phosphor paste solutions remained stable over 90 days with a wide range of added amounts of Disperbyk-180. Based on the above results, screen printing test was performed. The addition of Disperbyk-180 into phosphor and dielectric paste solutions produced improved qualities such as no phase separation, no bubble generation and no significant viscosity change during printing process. Especially for the phosphor paste solution, both uniformity and brightness were significantly improved and the excellent adhesion onto the ITO film was found. The ELD device fabricated using the above same paste solutions showed brightness of $57.6cd/m^2$ at 100V and 400 Hz. The half lifetime of ELD device was measured as 1,250 hours and almost the same value observed with imported commercial paste solutions.

Efficacy of various cleaning solutions on saliva-contaminated zirconia for improved resin bonding

  • Kim, Da-Hye;Son, Jun-Sik;Jeong, Seong-Hwa;Kim, Young-Kyung;Kim, Kyo-Han;Kwon, Tae-Yub
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.85-92
    • /
    • 2015
  • PURPOSE. This study aimed to investigate the efficacy of cleaning solutions on saliva-contaminated zirconia in comparison to air-abrasion in terms of resin bonding. MATERIALS AND METHODS. For saliva-contaminated air-abraded zirconia, seven cleaning methods)-no contamination (NC), water-spray rinsing (WS), additional air-abrasion (AA), and cleaning with four solutions (Ivoclean [IC]; 1.0 wt% sodium dodecyl sulfate [SDS], 1.0 wt% hydrogen peroxide [HP], and 1.0 wt% sodium hypochlorite [SHC])-were tested. The zirconia surfaces for each group were characterized using various analytical techniques. Three bonded resin (Panavia F 2.0) cylinders (bonding area: $4.5mm^2$) were made on one zirconia disk specimen using the Ultradent jig method [four disks (12 cylinders)/group; a total of 28 disks]. After 5,000 thermocycling, all specimens were subjected to a shear bond strength test with a crosshead speed of 1.0 mm/minute. The fractured surfaces were observed using an optical and scanning electron microscope (SEM). RESULTS. Contact angle measurements showed that groups NC, AA, IC, and SHC had hydrophilic surfaces. The X-ray photoelectron spectroscopy (XPS) analysis showed similar elemental distributions between group AA and groups IC and SHC. Groups IC and SHC showed statistically similar bond strengths to groups NC and AA (P>.05), but not groups SDS and HP (P<.05). For groups WS, SDS, and HP, blister-like bubble formations were observed on the surfaces under SEM. CONCLUSION. Within the limitations of this in vitro study, some of the cleaning solutions (IC or SHC) were effective in removing saliva contamination and enhancing the resin bond strength.

Heat/Mass Transfer Characteristics on Stationary Turbine Blade and Shroud in a Low Speed Annular Cascade (I) - Near-tip Blade Surface - (환형 캐스케이드 내 고정된 터빈 블레이드 및 슈라우드에서의 열/물질전달 특성 (I) - 블레이드 끝단 인접 표면 -)

  • Rhee Dong-Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.485-494
    • /
    • 2005
  • For the extensive investigation of local heat/mass transfer on the near-tip surface of turbine blade, experiments were conducted in a low speed stationary annular cascade. The turbine test section has a single stage composed of sixteen guide vanes and blades. The chord length and the height of the tested blade are 150 mm and about 125 mm, respectively. The blade has flat tip geometry and the mean tip clearance is about $2.5{\%}$ of the blade chord. Detailed mass transfer coefficient on the blade near-tip surface was obtained using a naphthalene sublimation technique. The inlet flow Reynolds number based on chord length and incoming flow velocity is changed from $1.0{\times}10^{5}\;to\;2.3{\times}10^{5}.$ Extremely complex heat transfer characteristics are observed on the blade surface due, to complicated flow patterns, such as flow acceleration, laminarization, transition, separation bubble and tip leakage flow. Especially, the suction side surface of the blade has higher heat/mass transfer coefficients and more complex distribution than the pressure side surface, which is related to the leakage flow. For all the tested Reynolds numbers, the heat/mass transfer characteristics on the turbine blade are the similar. The overall averaged $Sh_{c}$ values are proportional to $Re_{c}^{0.5}$ on the stagnation region and the laminar flow region such as the pressure side surface. However, since the flow is fully turbulent in the near-tip region, the heat/mass transfer coefficients are proportional to $Re_{c}^{0.8}.$

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

An Analysis on Fatigue Fracture of Nuclear Pump Impeller Alloys by Ultrasonic Vibratory Cavitation Erosion (원전 해수 펌프 임펠러 합금의 케비테이션 피로 손상 해석)

  • Hong Sung-Mo;Lee Min-Ku;Kim Gwang-Ho;Rhee Chang-Kyu
    • Journal of the Korean institute of surface engineering
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2006
  • In this study, the fatigue properties on the cavitation damage of the flame quenched 8.8Al-bronze (8.8Al-4.5Ni-4.5Fe-Cu) as well as the current nuclear pump impeller materials (8.8Al-bronze, STS316 and SR50A) has been investigated using an ultrasonic vibratory cavitation test. For this the impact loads of cavitation bubbles generated by ultrasonic vibratory device quantitatively evaluated and simultaneously the cavitation erosion experiments have been carried out. The fatigue analysis on the cavitation damage of the materials has been made from the determined impact load distribution (e.g. impact load, bubble count) and erosion parameters (e.g. incubation period, MDPR). According to Miner's law, the determined exponents b of the F-N relation ($F^b$ N = Constant) at the incubation stage (N: the number of fracture cycle) were 5.62, 4.16, 6.25 and 8.1 for the 8.8Al-bronze, flame quenched one, STS316 and SR50A alloys. respectively. At the steady state period, the exponents b of the F-N' curve (N': the number of cycle required for $1{\mu}m$ increment of MDP) were determined as 6.32, 5, 7.14 and 7.76 for the 8.8Al-bronze, flame quenched one, STS316, and SR50A alloys, respectively.

Langerhans Cell Histiocytosis with Central Diabetes Insipidus : A Case Report (중추성 요붕증이 동반된 랑게르한스 세포 조직구증 1예)

  • Kim, Jin-Ho;Moon, Jun-Sung;Mun, Sun-Jung;Lee, Ji-Eun;Choi, Jae-Won;Eun, Mi-Jung;Chun, Kyung-A;Cho, Ihn-Ho;Yoon, Ji-Sung;Won, Kyu-Chang;Lee, Kyung-Hee;Shin, Duk-Seop;Lee, Hyoung-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.2
    • /
    • pp.259-265
    • /
    • 2005
  • Central diabetes insipidus (DI) is a syndrome characterized by thirst, polydipsia and polyuria. Langerhans cell histiocytosis is one of the etiologies of DI. Recently we experienced a central DI associated with Langerhans cell histiocytosis. The 44 years old female patient complained right hip pain, polydipsia and polyuria. We carried out water deprivation test. After vasopressin injection, urine osmotic pressure was increased from 109 mOsmol/kg to 327 mOsmol/kg (300%). Brain MRI showed a thickened pituitary stalk and air bubble like lesions sized with 5cm, 7cm was shown on fifth L-spine and right hip bone at hip bone CT. CT guided biopsy revealed abnormal histiocytes proliferation and abundant lymphocytes. The final diagnosis was central DI associated with systemic Langerhans cell histiocytosis invading hip bone, L-spine and pituitary stalk. Desmopressin and etoposide chemotherapy were performed to the patient.

  • PDF