• Title/Summary/Keyword: Breast surgery

Search Result 1,298, Processing Time 0.029 seconds

Comparison of Patients Satisfaction with Direct to Implant versus Latissimus Dorsi Flap with Implant Breast Reconstruction Using Breast-Q

  • Ji Min Kim;Woo Jin Song;Sang Gue Kang
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.710-715
    • /
    • 2022
  • Background The latissimus musculocutaneous flap (LD flap) is a useful option for breast reconstruction following mastectomy. It has the advantage of obtaining sufficient tissue padding and natural shape by using autologous tissue. However, with the emergence of the skin-sparing mastectomy technique and artificial dermis matrix, direct-to-implant (DTI) breast reconstruction has become the first choice of surgery. The purpose of this study was to compare the satisfaction levels of patients who underwent DTI and LD flap with implant using patient-reported Breast-Q results. Methods A retrospective study was performed reviewing the records of 49 women who underwent immediate breast reconstruction with DTI or LD flap with implant and responded to the BREAST-Q questionnaire after the operation. The patient-reported breast-Q results were analyzed and correlated to the demographic information and intraoperative information. Results A total of 26 patients who underwent reconstruction with LD flap with implant and 23 patients with DTI were identified and responded to the questionnaire after an average of 32.3 and 10.4 months postoperation, respectively. According to the patient response to the breast-q values, satisfaction with breast was 60.0 and 57.0 points, psychosocial well-being 61.0 and 60.0 points, and sexual well-being 41.0 and 43.0 points in the two groups. Overall, there was no significant difference in the breastQ score between the two groups. Conclusion Patients who underwent DTI breast reconstruction seemed equally satisfied with the appearance and outcome of their breast reconstruction compared with LD flap with implant. Therefore, it appears that DTI is adequately replacing LD with implant.

A Nationwide Analysis Evaluating the Safety of Using Acellular Dermal Matrix with Tissue Expander-Based Breast Reconstruction

  • Jessica Luo;Whitney D. Moss;Giovanna R. Pires;Irfan A. Rhemtulla;Megan Rosales;Gregory J. Stoddard;Jayant P. Agarwal;Alvin C. Kwok
    • Archives of Plastic Surgery
    • /
    • v.49 no.6
    • /
    • pp.716-723
    • /
    • 2022
  • Background In March 2021, the United States Food and Drug Administration (FDA) safety communication cautioned against the use of acellular dermal matrix (ADM) products in breast reconstruction and reiterated that the FDA does not approve ADM use in breast surgery. This study aims to assess the safety of ADM use in breast reconstruction. Methods Women who underwent ADM and non-ADM assisted tissue expander (TE)-based breast reconstruction were identified using the National Surgical Quality Improvement Program database (2012-2019). Trends of ADM use over time, and 30-day outcomes of surgical site infection (SSI), dehiscence, and unplanned reoperation were assessed. Results Of the 49,049 TE-based breast reconstructive cases, 42.4% were ADM assisted and 57.6% non-ADM assisted. From 2012 to 2019, the use of ADM increased from 26.1 to 55.6% (relative risk [RR] =1.10; p < 0.01). Higher rates of SSI (3.9 vs. 3.4%; p = 0.003) and reoperation (7.4 vs. 6.0%; p < 0.001) were seen in the ADM cohort. There was no significant difference seen in dehiscence rates (0.7 vs. 0.7%; p = 0.73). The most common reoperation within 30 days for the ADM group (17.6%) was removal of TE without insertion of implant (current procedural terminology: 11,971). ADM-assisted breast reconstruction was associated with increased relative risk of SSI by 10% (RR = 1.10, confidence interval [CI]: 1.01-1.21; p = 0.03) and reoperation by 15% (RR = 1.15, CI: 1.08-1.23; p < 0.001). Conclusions ADM-assisted breast reconstruction more than doubled from 2012 to 2019. There are statistically higher complication rates of SSI (0.5%) and reoperation (1.4%) with ADM use in TE-based breast reconstruction, suggesting that reconstruction without ADM is safe when comparing immediate postoperative outcomes.

Immediate Bilateral Breast Reconstruction with Unilateral Deep Superior Epigastric Artery and Superficial Circumflex Iliac Artery Flaps

  • Hansen, Keith S.;Gutwein, Luke G.;Hartman, Brett C.;Sood, Rajiv;Socas, Juan
    • Archives of Plastic Surgery
    • /
    • v.43 no.5
    • /
    • pp.457-460
    • /
    • 2016
  • Autologous breast reconstruction utilizing a perforator flap is an increasingly popular method for reducing donor site morbidity and implant-related complications. However, aberrant anatomy not readily visible on computed tomography angiography is a rare albeit real risk when undergoing perforator flap reconstruction. We present an operative case of a patient who successfully underwent a bilateral breast reconstruction sourced from a unilateral abdominal flap divided into deep superior epigastric artery and superficial circumflex iliac artery flap segments.

Tabbed Tissue Expanders Improve Breast Symmetry Scores in Breast Reconstruction

  • Khavanin, Nima;Gust, Madeleine J.;Grant, David W.;Nguyen, Khang T.;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • v.41 no.1
    • /
    • pp.57-62
    • /
    • 2014
  • Background Achieving symmetry is a key goal in breast reconstruction. Anatomically shaped tabbed expanders are a new tool in the armamentarium of the breast reconstruction surgeon. Suture tabs allow for full control over the expander position and thus inframammary fold position, and, in theory, tabbed expanders mitigate many factors responsible for poor symmetry. The impact of a tabbed expander on breast symmetry, however, has not been formally reported. This study aims to evaluate breast symmetry following expander-implant reconstruction using tabbed and non-tabbed tissue expanders. Methods A chart review was performed of 188 consecutive expander-implant reconstructions that met the inclusion criteria of adequate follow-up data and postoperative photographs. Demographic, oncologic, postoperative complication, and photographic data was obtained for each patient. The photographic data was scored using a 4-point scale assessing breast symmetry by three blinded, independent reviewers. Results Of the 188 patients, 74 underwent reconstruction with tabbed expanders and 114 with non-tabbed expanders. The tabbed cohort had significantly higher symmetry scores than the non-tabbed cohort ($2.82/4{\pm}0.86$ vs. $2.55/4{\pm}0.92$, P=0.034). Conclusions The use of tabbed tissue expanders improves breast symmetry in tissue expander-implant-based breast reconstruction. Fixation of the expander to the chest wall allows for more precise control over its location and counteracts the day-to-day translational forces that may influence the shape and location of the expander pocket, mitigating many factors responsible for breast asymmetry.

The Kampo Medicine Goshajinkigan Prevents Neuropathy in Breast Cancer Patients Treated with Docetaxel

  • Abe, Hajime;Kawai, Yuki;Mori, Tsuyoshi;Tomida, Kaori;Kubota, Yoshihiro;Umeda, Tomoko;Tani, Tohru
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6351-6356
    • /
    • 2013
  • Background: Goshajinkigan (GJG) is used for the treatment of several neurological symptoms. We investigated the efficacy of GJG and mecobalamin (B12) against neurotoxicity associated with docetaxel (DOC) in breast cancer patients. Materials and Methods: Sixty breast cancer patients were treated with DOC. Thirty-three patients (GJG group) received oral administration of 7.5 g/day GJG and 27 patients (B12 group) received oral administration of 1500 ${\mu}g/day$ B12. Neuropathy was evaluated according to DEB-NTC (Neurotoxicity Criteria of Debiopharm), Common Terminology Criteria for Adverse Events (NCI-CTC) ver. 3.0, and a visual analogue scale (VAS). This study employed a randomized open design. Results: The incidence of neuropathy was 39.3% in the GJG group, and 88.9% in the B12 group (p<0.01). In the GJG group, grade 1 DEB-NTC was observed in 2 cases, grade 2 in 5 cases and grade 3 in 5 cases. Grade 1 NCI-CTC was observed in 7 cases, grade 2 in 6 cases, and VAS was $2.7{\pm}2.2$. In the B12 group, grades 1, 2 and 3 DEB-NTC were observed in one case, 12 cases and 12 cases, respectively; and grades 1, 2 and 3 NCI-CTC were observed in 11 cases, 12 cases and one case, and VAS was $4.9{\pm}2.4$. Conclusions: Concomitant administration of GJG is useful in preventing neuropathy in breast cancer patients treated with a DOC regimen.

PKCδ-dependent Activation of the Ubiquitin Proteasome System is Responsible for High Glucose-induced Human Breast Cancer MCF-7 Cell Proliferation, Migration and Invasion

  • Zhu, Shan;Yao, Feng;Li, Wen-Huan;Wan, Jin-Nan;Zhang, Yi-Min;Tang, Zhao;Khan, Shahzad;Wang, Chang-Hua;Sun, Sheng-Rong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5687-5692
    • /
    • 2013
  • Type 2 diabetes mellitus (T2DM) has contributed to advanced breast cancer development over the past decades. However, the mechanism underlying this contribution is poorly understood. In this study, we determined that high glucose enhanced proteasome activity was accompanied by enhanced proliferation, migration and invasion, as well as suppressed apoptosis, in human breast cancer MCF-7 cells. Proteasome inhibitor bortezomib (BZM) pretreatment mitigated high glucose-induced MCF-7 cell growth and invasion. Furthermore, high glucose increased protein kinase C delta ($PKC{\delta}$)-phosphorylation. Administration of the specific $PKC{\delta}$ inhibitor rottlerin attenuated high glucose-stimulated cancer cell growth and invasion. In addition, $PKC{\delta}$ inhibition by both rottlerin and $PKC{\delta}$ shRNA significantly suppressed high glucose-induced proteasome activity. Our results suggest that $PKC{\delta}$-dependent ubiquitin proteasome system activation plays an important role in high glucose-induced breast cancer cell growth and metastasis.

Safety Assessment of Intravenous Administration of Trastuzumab in 100ml Saline for the Treatment of HER2-Positive Breast Cancer Patients

  • Abe, Hajime;Mori, Tsuyoshi;Kawai, Yuki;Tomida, Kaori;Yamazaki, Keiichi;Kubota, Yoshihiro;Umeda, Tomoko;Tani, Tohru
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4843-4846
    • /
    • 2013
  • Background: The infusion rate is considered to affect incidence and severity of infusion reactions (IRs) caused by protein formulations. Trastuzumab (TRS) is approved for 90-minute infusion as the initial dose followed by 30-minute infusion with 250 ml saline. In the study, we evaluated the safety of TRS intravenously administered over 30 minutes with 100 ml saline to reduce burden of patients, safety of infusion with 250 ml saline already being established. Materials and Methods: Women with HER2 positive breast cancer, ${\geq}18$ years and ${\geq}55%$ left ventricular ejection fraction (LVEF), were registered in the study. Patients received 8mg/kg of TRS 250 ml over 90 minutes followed by 6mg/kg of TRS 100ml over 30 minutes in a three-week cycle. Results: A total of 31 patients were recruited, 24 for adjuvant therapy and seven with metastases. The median age was 59 years (range 39 to 82). The total number of TRS doses ranged from 5 to 17 with the median of 15. Mild IR occurred in two patients at the first dose. However, no IR was observed after reducing to 100 ml saline. No decrease of LVEF, increase of serum brain natriuretic peptide or any other adverse events were reported. Conclusions: Intravenous infusion of TRS with 100 ml saline over 30 minutes in breast cancer patients can be considered safe based on results from the study. It can be given on an outpatient basis as with the currently recommended dilution in 250 ml saline.

Differential Distribution of microRNAs in Breast Cancer Grouped by Clinicopathological Subtypes

  • Li, Jian-Yi;Jia, Shi;Zhang, Wen-Hai;Zhang, Yang;Kang, Ye;Li, Pi-Song
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3197-3203
    • /
    • 2013
  • Background: microRNAs (miRNAs) that regulate proliferation, invasion and metastasis are considered to be the principal molecular basis of tumor heterogeneity. Breast cancer is not a homogeneous tissue. Thus, it is very important to perform microarray-based miRNA screening of tumors at different sites. Methods: Breast tissue samples from the centers and edges of tumors of 30 patients were classified into 5 clinicopathological subtypes. In each group, 6 specimens were examined by microRNA array. All differential miRNAs were analyzed between the edges and centers of the tumors. Results: Seventeen kinds of miRNAs were heterogeneously distributed in the tumors from different clinicopathological subtypes that included 1 kind of miRNA in Luminal A and Luminal B Her2+ subtypes, 4 kinds in Luminal A and Her2 overexpression subtypes, 6 kinds in Luminal B Ki67+ and Luminal B Her2+ subtypes, 2 kinds between Luminal B Ki67+ and triple-negative breast cancer (TNBC) subtypes, 2 kinds between Luminal B Her2+ and TNBC subtypes, and 2 kinds between Luminal B Ki67+, Luminal B Her2+, and TNBC subtypes. Twenty kinds of miRNAs were homogenously distributed in the tumors from different clinicopathological subtypes that included 6 kinds of miRNAs in Luminal B Ki67+ and Luminal B Her2+ subtypes, 1 kind in Luminal B Ki67+ and Her2 overexpression subtypes, 10 kinds between Luminal B Ki67+ and TNBC subtypes, 2 kinds in Luminal B Her2+ and TNBC subtypes, and 1 kind between Luminal B Ki67+, Luminal B Her2+, and TNBC subtypes. Conclusions: A total of 37 miRNAs were significantly distributed in tumors from the centers to edges, and in all clinicopathological subtypes.

Nationwide Analysis of Treatment Patterns for Korean Breast Cancer Survivors Using National Health Insurance Service Data

  • Chung, Il Yong;Lee, Jihyoun;Park, Suyeon;Lee, Jong Won;Youn, Hyun Jo;Hong, Jung Hwa;Hur, Ho
    • Journal of Korean Medical Science
    • /
    • v.33 no.44
    • /
    • pp.276.1-276.10
    • /
    • 2018
  • Background: The National Health Insurance Service (NHIS) established a healthcare claim database for all Korean citizens. This study aimed to analyze the NHIS data and investigate the patterns of breast cancer treatments. Methods: We constructed a retrospective female breast cancer cohort by analyzing annual incident cases. The annual number of newly diagnosed female breast cancer was compared between the NHIS data and Korea National Cancer Incidence Database (KNCIDB). The annual treatment patterns including surgery, chemotherapy, radiation therapy, endocrine therapy and targeted therapy were analyzed. Results: A total of 148,322 women with newly diagnosed invasive breast cancer during 2006-2014 was identified. The numbers of newly diagnosed invasive breast cancer cases were similar between the NHIS data and KNCIDB, which demonstrated a strong correlation (r = 0.995; P < 0.001). The age distribution of the breast cancer cases in the NHIS data and KNCIDB also showed a strong correlation (r = 1.000; P < 0.001). About 85% of newly diagnosed breast cancer patients underwent operations. Although the proportions of chemotherapy use have not changed during 2006-2014, the total number of chemotherapy prescriptions sharply increased during this period. The proportions of radiotherapy and anti-hormonal therapy increased. Among the anti-hormonal agents, tamoxifen was the most frequently prescribed medication, and letrozole was the most preferred endocrine treatment in patients aged ${\geq}50$ years. Conclusion: Along with the increased breast cancer incidence in Korea, the frequencies of breast cancer treatments have increased. The NHIS data can be a feasible data source for future research.

A Study on the Brassiere Wearing Condition and Satisfaction of Augmentation Mammaplasty Patients (유방 확대 수술 환자의 브래지어 착용실태 및 만족도 조사)

  • Yi, Kyong-Hwa;Nam, Young-Ran
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.6
    • /
    • pp.1141-1153
    • /
    • 2017
  • The wearing of the correction bra is very important to stabilize the shape of an implant after breast enlargement surgery; however, the verification of the wearing effect is insufficient. This study surveyed women who experienced breast augmentation surgery, to investigate wearing condition and satisfaction with bras worn immediately after surgery and during the recovery period as well as to collect basic data for the development of an improved patient bra. The study results are as follows. More than half of the respondents stated that they wear a cupless brassiere. As a result of the satisfaction by brassiere types, the cupless bra showed the highest satisfaction. The most important factor in choosing a patient's bra after breast augmentation surgery was the "degree of breast compression". Through the application of the results of this study, the necessity of development of the brassiere for breast enlargement patients with improved function and comfort was understood. It is therefore necessary to improve the function of holding the shape of the breast and applying appropriate pressure as well as designing the ventilated material without skin irritation that is superior to the existing brassieres.