• Title/Summary/Keyword: Break-In

Search Result 3,247, Processing Time 0.032 seconds

A Study on the Combinative Patterns of Lapel and Collar in Tailored Jackets with Different Break Line (테일러드 재킷 꺽임선에 따른 라펠과 윗칼라의 조화에 관한 패턴 연구)

  • Jung, Doo-Yi;Song, Jung-A
    • Fashion & Textile Research Journal
    • /
    • v.14 no.6
    • /
    • pp.952-959
    • /
    • 2012
  • This study looks into the changes in collar patterns in tailored jackets with different numbers of buttons. The study discusses the pattern design method of tailored colors in 4 different styles, such as the effect of the number of buttons of tailored jackets on collar width and length, lapel width and length, and angle of lapel and overall balance in design. Through the first dress experiment, patterns were adjusted and corrected. The second dress experiment was conducted with the modified experimental clothes. The results of comparison and analysis are as follows. The 1 button tailored jacket was most preferred for its beautiful expression and overall balance of upper color and lapel when its lapel width was 7.5 cm. The second most preferred one was the 2 button tailored jacket with lapel width of 8 cm, and the 3 button jacket showed relatively good balance when its lapel width was 7.5 cm. The 4 button tailored jacket showed a bad balance in collar and button. Also, its overall silhouette was disappointing and thus was less preferred than others. For smaller number of buttons, the angle of lapel's break line increased, thus displaying a more refined and slim silhouette. On the other hand, the angle of lapel's break line decreased for greater number of buttons, thus displaying a dull and fat image. As a result, the jacket with many buttons was less preferred.

Stereo-photogrammetry Analysis for Over-break Control (여굴 제어를 위한 입체사진측량기법 분석)

  • Kim, Byung-Ryeol;Jeong, Min-Su;Jin, Yeon-Ho;Choi, Sung-Oong
    • Explosives and Blasting
    • /
    • v.36 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • When an underground limestone mine selects room-and-pillar mining method, in which the stability of mine openings is maintained by leaving safety pillars, the stability of safety pillars is always incompatible with their productivity. Therefore, the engineering decision for stability and productivity is essential. In this study, a progress of excavation faces by conventional blasting pattern has been examined in field for investigating over-break and stereo-photogrammetry method has been applied to this field measurement for improvement of accuracy. Also this result has been reflected instantly to composite blasting pattern by feedback, for minimizing overbreak. Field tests showed the relevant results that $3.5m^2$ in over-break out of $70m^2$ in total excavation face has been decreased, that is 5% of reduction rate in maximum.

Beneficial Analysis of Chestnut Cultivation (밤나무 재배 수익성 분석)

  • Park, Yong Bae;Jung, Byeong Heon;Choi, Soo Im
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.6
    • /
    • pp.661-666
    • /
    • 2007
  • This study is to give investment information to someone who will manage a chestnut orchard or has been managing a chestnut orchard by means of profit by producers' chestnut price and a term of investment retrieval because of fluctuations in chestnut prices in the opening time by FTA. This study, hence, evaluated 133 families who manage a chestnut orchard at Jin-ju, San-cheoung in Gyeong-nam, Gu-rae in Jeon-nam, Gong-ju, Bu-yeo, Cheoung-yang in Chung-nam. This study used IRR, B/C Ration, NPV and the break-even point sales methods. As the result of this study, there are investment value at much than 1,140 won/kg including wages themselves at 4% interest, however, there are not investment value at less than 1,140 won/kg in the same economic condition. Furthermore, an investor could retrieve the investment at sixteen year and the break-even point sales is 32,963,000 won/ha. If 3,000 won/kg, an investor could retrieve the investment at nine year and the break-even point sales is 15,176,000 won.

Physical Condition and User's Satisfaction on the Commom Public Areas of High School Dormitory in Local Area (지방 고등학교 기숙사의 공동생활공간에 대한 이용실태 및 사용자 만족도)

  • Choi, Byungsook;An, Jinsook
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • This study was to analyze physical condition on the dormitory high school in Jeonju City, and find out users' satisfaction on that. This was going to contribute to the directions of it's physical environmental improvement. This was performed by a questionnaire survey method. Data were collected from 200 students, who had been dwelling 4 high school dormitories in Jeonju City. Through analyzing those data about library, diningroom, laundry room, break room, computer room, restroom, shower room, hall lounge, and snack bar in a dormitory, the results are as follows. First, students thought some physical conditions to be inconvenient in an distracted study atmosphere and hard furniture of library, a bad location of diningroom, a short laundry machine, lack of tables in a break room, a short performance and supply computer, a small space and short toilet in restroom, and a short of hall lounge and snack bar. Second, the students' satisfaction of common public areas in dormitory was 3.39 score. Students were concerned with library and restroom shower room through analyzing satisfied and unsatisfied areas. Third, they needed to improve heating, cooling, and noise in common areas of dormitory, and needed to support a breakroom and snack bar. Conclusively, library, restroom shower room, break room, and snack bar were important common areas, and indoor environmental elements - heating, cooling and noise- were important in high school dormitory.

DNA-Dependent Protein Kinase Catalytic Subunit (DNA-PKcs): Beyond the DNA Double-Strand Break Repair

  • Ye-Rim Lee;Gi-Sue Kang;Taerim Oh;Hye-Ju Jo;Hye-Joon Park;G-One Ahn
    • Molecules and Cells
    • /
    • v.46 no.4
    • /
    • pp.200-205
    • /
    • 2023
  • DNA-dependent protein kinase catalytic subunit (DNA-PKcs), a member of the phosphatidylinositol 3-kinase-related kinase family is a well-known player in repairing DNA double-strand break through non-homologous end joining pathway. This mechanism has allowed us to understand its critical role in T and B cell development through V(D)J recombination and class switch recombination, respectively. We have also learned that the defects in these mechanisms lead to the severely combined immunodeficiency (SCID). Here we highlight some of the latest evidence where DNA-PKcs has been shown to localize not only in the nucleus but also in the cytoplasm, phosphorylating various proteins involved in cellular metabolism and cytokine production. While it is an exciting time to unveil novel functions of DNA-PKcs, one should carefully choose experimental models to study DNA-PKcs as the experimental evidence has been shown to differ between cells of defective DNA-PKcs and those of DNA-PKcs knockout. Moreover, while there are several DNA-PK inhibitors currently being evaluated in the clinical trials in an attempt to increase the efficacy of radiotherapy or chemotherapy, multiple functions and subcellular localization of DNA-PKcs in various types of cells may further complicate the effects at the cellular and organismal level.

An Application of Realistic Evaluation Methodology for Large Break LOCA of Westinghouse 3 Loop Plant

  • Choi, Han-Rim;Hwang, Tae-Suk;Chung, Bub-Dong;Jun, Hwang-Yong;Lee, Chang-Sub
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.513-518
    • /
    • 1996
  • This report presents a demonstration of application of realistic evaluation methodology to a posturated cold leg large break LOCA in a Westinghouse three-loop pressurized water reactor with 17$\times$17 fuel. The new method of this analysis can be divided into three distinct step: 1) Best Estimate Code Validation and Uncertainty Quantification 2) Realistic LOCA Calculation 3) Limiting Value LOCA Calculation and Uncertainty Combination RELAP5/MOD3/K [1], which was improved from RELAP5/MOD3.1, and CONTEMPT4/MOD5 code were used as a best estimate thermal-hydraulic model for realistic LOCA calculation. The code uncertainties which will be determined in step 1) were quantified already in previous study [2], and thus the step 2) and 3) for plant application were presented in this paper. The application uncertainty parameters are divided into two categories, i.e. plant system parameters and fuel statistical parameters. Single parameter sensitivity calculations were performed to select system parameters which would be set at their limiting value in Limiting Value Approach (LVA) calculation. Single run of LVA calculation generated 27 PCT data according to the various combinations of fuel parameters and these data provided input to response surface generation. The probability distribution function was generated from Monte Carlo sampling of a response surface and the upper 95$^{th}$ percentile PCT was determined. Break spectrum analysis was also made to determine the critical break size. The results show that sufficient LOCA margin can be obtained for the demonstration NPP.

  • PDF

Development of Extra High Voltage(400kN) Porcelain Insulator for Transmission Lines (765 kV용 400 kN 현수애자 개발)

  • 최인혁;최장현;이동일;최연규
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.8
    • /
    • pp.348-353
    • /
    • 2003
  • This paper was the research of high voltage suspension insulator (400 [kN]) including pottery stone, feldspar, clay and alumina of 17 [wt%]. The slurry was fabricated after ball milling mixed raw materials. Green compacts were made by the extrusion of jiggering method and were sintered at 1300[$^{\circ}C$] for 50 [min.] in the tunnel kiln. The sintered density was reached to 97% of theoretical density, and the bending strength was 1658 [k $g_{f}$/$\textrm{cm}^2$] and hardness and fracture toughness which was measured by ICL( indentation crack length ) method were 1658 (kgf/$\textrm{cm}^2$) and 27.5 [Gpa], respectively. In measurement of tana and insulation break voltage of 400 (kN) porcelain, tan$\delta$ took some numerical value between 17${\times}$10$_{-3}$ and 61${\times}$10$_{-3}$ and insulation break voltage value was 19.9$\pm$1.4 [㎸/mm]. The test was performed to research whether the shape of pin affect a overvoltage break load or not As a consequence, when a pin was designed a pin diameter 51 [mm] with the bottom form of two-step constructed with straight in the suspension insulator, Insulator showed overvoltage break load 52 [ton] of the highest value and reflected a fine characteristic in aged deterioration test which is one of the accelerated aging test. Also it could be confirmed a fine characteristic through performing the test that electrical property of insulator was established correctly in accordance with IEC 60383-1 standards.s.

A Numerical Study on Propagation Characteristics of Dam-break Wave through a Porous Structure (다공성 구조물을 통과하는 댐 붕괴파의 전파특성에 관한 수치적 연구)

  • Jeong, Woochang
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.1
    • /
    • pp.11-24
    • /
    • 2014
  • In this study, the characteristics of the propagation of dam-break wave through a porous structure in a water tank is numerically analyzed by using the three-dimensional numerical model (ANSYS CFX model). As results of comparison between the existing measured and simulated water depth distributions in and around a porous structure, the agreement is relatively well satisfied. Moreover, for the case of the presence in part of a porous structure in a water tank, the three-dimensional flow structure is numerically analyzed In general, compared with in the area with a porous structure, the abrupt variation of water depth occurs in the area without a porous structure. It is shown that the porous structure can play a role to decrease the abrupt variation of water depth.

Prediction of Break Indices in Korean Read Speech (국어 낭독체 발화의 운율경계 예측)

  • Kim Hyo Sook;Kim Chung Won;Kim Sun Ju;Kim Seoncheol;Kim Sam Jin;Kwon Chul Hong
    • MALSORI
    • /
    • no.43
    • /
    • pp.1-9
    • /
    • 2002
  • This study aims to model Korean prosodic phrasing using CART(classification and regression tree) method. Our data are limited to Korean read speech. We used 400 sentences made up of editorials, essays, novels and news scripts. Professional radio actress read 400sentences for about two hours. We used K-ToBI transcription system. For technical reason, original break indices 1,2 are merged into AP. Differ from original K-ToBI, we have three break index Zero, AP and IP. Linguistic information selected for this study is as follows: the number of syllables in ‘Eojeol’, the location of ‘Eojeol’ in sentence and part-of-speech(POS) of adjacent ‘Eojeol’s. We trained CART tree using above information as variables. Average accuracy of predicting NonIP(Zero and AP) and IP was 90.4% in training data and 88.5% in test data. Average prediction accuracy of Zero and AP was 79.7% in training data and 78.7% in test data.

  • PDF

Application of the Leak Before Break(LBB) Concept to a Heat Exchanger in a Nuclear Power Plant

  • Kwon, Jae-Do;Lee, Choon-Yeol;Lee, Yong-Son;Sul, Il-Chan
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.10-20
    • /
    • 2001
  • The leak before break(LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount(approximately 37.9 liters) containing the radioactive material which can activate the radiation detector device installed in near the heat exchanger is assumed. A postulated initial flaw size that can not grow to a critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat exchanger is not impeded. Particularly the informational scenario presented in this paper discusses an actual nuclear plant.

  • PDF