The study of a primary role of Back up Breaker and Making Switch for Short Circuit Test (단락시험에서 후비보호차단기와 투입스위치의 중요 역할)

  • Kim, Sun-Koo;Kim, Seon-Ho;Kim, Won-Man;Roh, Chang-Il;Lee, Dong-Jun;Jung, Heung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.915-916
    • /
    • 2007
  • There are many equipments for the Short Circuit Test, for example Short Circuit Generator, Induction Motor, Sequence Timer, Exciter, CLR, Back Up Breaker, Making Switch and TRV etc. Especially Back up Breaker and Making Switch are very important equipments to test the short circuit test. A role of a Back up Breaker is to break high-voltage and high-current for short circuit test and a Making Switch should be operated always same speed/time and kept electrical-mechanical characteristics to make the voltage and current of short circuit test. This study introduces to the short circuit test also to kinds, principal movements and compare them of Back up Breaker and Making Switch.

  • PDF

Development of Paper-based Microfluidic Device for Dry Eye Test (종이-미세유체공학을 이용한 건성안 검사 용지 개발)

  • Seo, Young Tae;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Purpose: The aim of this study was to develop a dry eye test method using a paper based microfluidic device that improves inaccuracy caused by using one of current point-of-care dry eye tests such as Shirmer's. Methods: Wax printed hydrophilic chromatography papers were dyed with anthocyanin extracts to detect colorimetric display of liquid samples with varying pH. Fluid distribution rates were measured using artificial tears and human tears directly from 32 subjects. Results: With Shirmer's, fluid distribution rates with small amount of samples (less than $0.5{\mu}l$) were not displayed. However, with paper based microfluidic device, fluid imbibition distances over time were clearly showed. Also clinical results of dry eye from newly developed paper based microfluidic device showed correlation with the results from tear break up time tests. Conclusions: The newly developed paper based microfluidic devices were easy to use and exhibited more accurate clinical results than current dry eye point of care tests such as Shirmer's.

Mechanical Characteristic Test of Architectural ETFE Film Membrane (건축용 ETFE 필름 막의 역학적 특성 시험)

  • Park, Kang-Geun;Yoon, Seoung-Hyun;Bae, Boo-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.2
    • /
    • pp.77-82
    • /
    • 2009
  • ETFE is the abbreviation of Ethlene Tetra Fluoro Ethlene, a sort of colorless and transparent granules. The advantage of ETFE film has chemical resistance, anti-stick property, very lightly material. The thickness of ETFE film is used to from 50 ${\mu}m$ to 300 ${\mu}m$ and have superior ability of daylight transmission and elongation, while the strength is lower than of fabric membrane. The tensile strength of ETFE film changes from 40Mpa to 60Mpa and the tensile strain at break can get to about 300-400%. The mechanical characteristic test of ETFE film is described in this paper. The tensile strain at break, the tensile strength and the stress-strain curve are obtained from the test. And then it was analyzed stress-strain characteristic by temperature and mechanical characteristic by cycling load.

  • PDF

Assembly and Test of the In-cryostat Helium Line for KSTAR (KSTAR 저온용기 내부의 헬륨라인 설치 및 검사)

  • Bang, E.N.;Park, H.T.;Lee, Y.J.;Park, Y.M.;Choi, C.H.;Bak, J.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • In-cryostat helium lines are under installation to transfer a cryogenic helium into cold components in KSTAR device. In KSTAR, three kinds of helium should be supplied into the cold components, which are supercritical helium Into superconduction(SC) magnet system, liquid helium into current lead system, and gas helium into thermal shields. Cryogenic helium lines consist of transfer lines outside the cryostat, in-cryostat helium lines, and electrical breaks. In-cryostat helium lines should be guaranteed of leak tightness for tong time operation at high internal helium pressure of 20 bar. We wrapped the helium line with multi-layer insulator(MLI) to reduce radiation heat and insulated the surface of the high potential part with prepreg tape. The electrical break was fabricated by brazing ceramic tube with stainless steel tube. To ensure the operation reliability at operation temperature, all the electrical break have been examined by the thermal cycle test at liquid nitrogen and by the hydraulic test at 30 bar. And additional surface insulation was prepared with prepreg tape to give structural safety. At present most of the in-cryostat helium lines have been installed and the final inspection test is progressing.

Measurement of Amplitude of Accommodation using Push-up and Push-away and Near Point of Convergence in Elementary School Children (초등학생에서 push-up과 push-away 방법을 이용한 조절력과 폭주 근점의 측정)

  • Kim, Hyojin;Lee, Eun-Hee;Oh, Hyunjin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.279-284
    • /
    • 2012
  • Purpose: We measured the amplitude of accommodation using the push-up and push-away tests and near point of convergence (NPC) and investigated the accommodative insufficiency (AI) and convergence insufficiency (CI) in elementary school children of 12~13 years old. Methods: 88 students who aged 12~13 $12.63{\pm}0.51$ years old with more than 1.0 spectacle best corrected visual acuity were examined using push-up and push-away tests. The break and recovery points of NPC also were measured. Results: Mean amplitudes of accommodations using push-up and push-away tests were $11.52{\pm}2.50D$ and $10.06{\pm}1.97D$, respectively in right eye (P<0.001). Mean break and recovery points in NPC were $8.66{\pm}1.99cm$ and $10.98{\pm}2.06cm$. AI and CI showed 28.75% and 30.00% each. 48.75% was within normal range in both amplitudes of accommodations according to their age expected and convergence. Students having both AI and CI were 7.50%. Conclusions: A high correlation between the push-up test and push-away test was found in elementary school children (r=0.6025; P<0.05). Students having normal amplitude of accommodation by their age expected and normal convergence were 71.25% and 70.00%, respectively.

Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구)

  • Ryu, Sung Uk;Bae, Hwang;Ryu, Hyo Bong;Byun, Sun Joon;Kim, Woo Shik;Shin, Yong-Cheol;Yi, Sung-Jae;Park, Hyun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.165-172
    • /
    • 2016
  • An experimental study of the thermal-hydraulic characteristics of passive safety systems (PSSs) was conducted using a system-integrated modular advanced reactor-integral test loop (SMART-ITL). The present passive safety injection system for the SMART-ITL consists of one train with the core makeup tank (CMT), the safety injection tank, and the automatic depressurization system. The objective of this study is to investigate the injection effect of the PSS on the small-break loss-of-coolant accident (SBLOCA) scenario for a 0.4 inch line break in the safety-injection system (SIS). The steady-state condition was maintained for 746 seconds before the break. When the major parameters of the target value and test results were compared, most of the thermal-hydraulic parameters agreed closely with each other. The water level of the reactor pressure vessel (RPV) was maintained higher than that of the fuel assembly plate during the transient, for the present CMT and safety injection tank (SIT) flow rate conditions. It can be seen that the capability of an emergency core cooling system is sufficient during the transient with SMART passive SISs.

Performance Evaluation of the HTS Bulk type Motor (고온초전도벌크형 전동기의 특성시험)

  • Sim, Jung-Wook;Lim, Hyoung-Woo;Cha, Guee-Soo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.2 no.2
    • /
    • pp.44-48
    • /
    • 2000
  • The high temperature superconducting bulk can be used as the rotor of an ac motor. This paper presents the fabrication and test results of a ac motor with HTS bulk rotor. The rotor of a conventional squirrel cage induction motor was replaced with cylinder type YBCO bulk. Height and outer diameter of the HTS bulk was 15mm and 46mm, respectively. Eddy current brake using aluminium disk was used to measure the torque of the HTS motor. No load test, locked rotor test and load test were performed to examine the characteristics of the HTS motor. Test results show the motor can rotate at synchronous speed without any special starting circuit. Maximum output power of the constructed HTS motor was 408W.

  • PDF

Self stretching and manual therapy influence on lunge test (자가 스트레칭과 도수치료가 런지 테스트에 미치는 영향)

  • Lee, Jae Gwan;Ko, Kun Seok;Jung, Ji Yun;Choi, Yun Jung;Seo, Su Ji
    • Journal of Korean Physical Therapy Science
    • /
    • v.21 no.1
    • /
    • pp.59-63
    • /
    • 2014
  • Purpose : To determined the effect of self-stretching and manual therapy on ankle joint about ROM and persisting effect. Method : Twenty participants(6 male, 14 female) ramdomly divided into self-stretching and manual therapy group. Each participant started with lunge test then self-stretching and manual therapy intervention was performed. After intervention lunge test was performed again. Last lunge test was performed after 30 minute break. Result : Result of lunge test showed both self-stretching and manual therapy group have significant difference in immediate increase of ROM and persistence effect(p<0.05). However, persistence effect of each group did not show significant difference(p>0.05). Conclusion : Manual therapy and well-designed self-stretching by therapist showed the effect in increase ROM.

  • PDF

A Study on the Measurement of Crack Length of Pipe Specimen Using Image Processing (이미지 프로세싱을 이용한 실배관 시험편의 균열 길이 측정에 관한 연구)

  • Kang, Min-Sung;Koo, Jae-Mean;Seok, Chang-Sung;Huh, Yong
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.2
    • /
    • pp.7-11
    • /
    • 2010
  • Difficulties associated with full-scale pipe tests are rather obvious. That is, it is not only difficult to perform them but also very expensive and it requires lots of experience. And the process of the fracture test for the pipe specimen is very difficult and complicated. Because the pipe specimen, the test jig and the test equipment are very large and heavy, it requires lots of costs and times. In this study, to easily perform the fracture toughness test for a pipe specimen, load line displacement data was obtained using the image processing method.

Effects of Health Behaviors on Perceived Physical and Psychological Job Stress Among Korean Manufacturing Workers (제조업 근로자의 건강행위와 직무로 인한 스트레스 자각증상의 관련성)

  • 박경옥;김인석;오영아
    • Korean Journal of Health Education and Promotion
    • /
    • v.21 no.3
    • /
    • pp.195-211
    • /
    • 2004
  • Stress is a primary health promotion issue in worksite research because psychological distress is closely related not only to workers' health status but also to their job performance. This study identified the significant health behaviors affecting workers' job-related stress in Korean manufacturing industry with the national survey data conducted by the Korean Occupational Safety and Health Agency in 2003. A total of 7,818 factory workers in 1,562 manufacturing companies participated in the Korean nation-wide occupational health survey and 3,390 workers answered that they had any stressors in their workplace among the 7,818 workers finally participated in the analysis. Participants were selected by the stratified proportional sampling process by manufacturing industry classification, company size, and company locations (8 metropolitan and 8 non-metropolitan regions) in Korea. Trained interviewers visited the target companies and interviewed the factory workers randomly selected in each company. Smoking, drinking, weight control, exercise, sleeping, break time at work, and perceived fatigue were included in the health behavior construct. Stress symptoms was consisted of physical and psychological stress with 8 items. All survey responses were anonymously coded into the SPSS statistical program and testified using stepwise multiple regression analysis. Male workers were 73.5% and the 30s were 40.0% among the age groups. The married and the high school graduate were majority with 52.1% and 61.8% each. Current smokers were 44.7% and More than 50% of the participants drank alcohol sometimes. No exercise group was 59.3% and the participants who dissatisfied with their daily sleeping hours were 43.5%. In t-test and analysis of variance, the significant general characteristics associated with physical and psychological job stress were young age (p<0.001), single marital status (p<0.001), and short working period at the present company (p<0.001). The health behaviors related to physical job stress were current smoking, weight change during the past one year (p<0.001), weight control effort (p<0.001), exercise (p<0.001), daily sleeping dissatisfaction (p<0.001), break time, and perceived fatigue (p<0.001). All 10 health behavior factors were significantly associated with psychological job stress (p<0.05). Weight change, weight control effort, exercise, daily sleeping dissatisfaction, little break at work, and high perceived fatigue were significant factors affecting job stress. Daily sleeping dissatisfaction, little break at work, little exercise, weight change for the past one year and young age were selected as the significant health behavior and general factors affecting physical job stress symptoms in stepwise multiple regression analysis. The five factors explained 18.9% of the physical stress score variance. Six factors were selected as the significant health behaviors affecting psychological job stress: daily sleeping dissatisfaction, little exercise, frequent drinking alcohol, high perceived fatigue, little break at work, and little weight control effort. The six factors explained 10.6% of the psychological stress score variance.