• Title/Summary/Keyword: Braking Resistor

Search Result 11, Processing Time 0.038 seconds

Study on the Braking Characteristics of Starting System Used for Initial Spin-up of Gas Turbine (가스터빈 초기 구동용 시동시스템의 제동특성 연구)

  • Song, Ju-Young;Park, Jun-Cheol;Lee, Ki-Hoon;Kim, Sung-Hyun;Nam, Sam-Sik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.379-382
    • /
    • 2011
  • Engine test as well as unload test of starting motor itself was performed to evaluate the braking characteristics of starting system used for initial spin-up of gas turbine for power generation. Through the experimental evaluation of the braking performance with the capacity of braking resistor of the starting motor, we have achieved quantitative data to secure robust braking characteristics in emergency during the starting period of the gas turbine. It is possible to establish a capacity selection criterion of braking resistor to ensure the starting reliability of the gas turbine.

  • PDF

A Study on Drive in Extending Break Power of The PMSM using series Resistor (영구 자석형 동기전동기(PMSM)의 직렬저항을 이용한 제동력 운전 확보에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Kim, Young-Bog;Chung, Nam-Kil
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.1
    • /
    • pp.132-141
    • /
    • 2013
  • In this paper, method using electric braking from stop area to high-speed area was presented in order to improve air-brake. And electric braking method can be improved environmental problems, efficiency, economy, etc. Method for electrical complete braking are two ways that method of inserting series resistance between the motor and the inverter, and method of inverter output voltage increase. In this paper, use series resistance insert method because economical and easy to apply. In addition, Series resistor is used short circuit method for reduce the power loss. In improved efficiency and the laboratory environment for secure braking, resistance insert method and inverter output voltage increase method showed same characteristics in all areas.

A Study on Driving and simulation in Extending Break Power of The PMSM using series Resistor (PMSM의 직렬저항을 사용한 제동력 확보 운전과 시뮬레이션에 관한 연구)

  • Hwang, Lark-Hoon;Kim, Young-Bog;Na, Seung-Kwon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.4
    • /
    • pp.191-197
    • /
    • 2012
  • In this paper, method using electric braking from stop area to high-speed area was presented in order to improve air-brake. And electric braking method can be improved environmental problems, efficiency, economy, etc.. Method for electrical complete braking are two ways that method of inserting series resistance between the motor and the inverter, and method of inverter output voltage increase. In this paper, use series resistance insert method because economical and easy to apply. In addition, Series resistor is used short circuit method for reduce the power loss. In improved efficiency and the laboratory environment for secure braking, resistance insert method and inverter output voltage increase method showed same characteristics in all areas.

A Study on Drive in Extending Break Power of The PMSM using series Resistor (영구 자석형 동기전동기(PMSM)의 직렬저항을 사용한 제동력 운전 확보에 관한 연구)

  • Hwang, Lark Hoon;Na, Seung Kwon;Kim, Young Bog
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • In this paper, method using electric braking from stop area to high-speed area was presented in order to improve air-brake. And electric braking method can be improved environmental problems, efficiency, economy, etc. Method for electrical complete braking are two ways that method of inserting series resistance between the motor and the inverter, and method of inverter output voltage increase. In this paper, use series resistance insert method because economical and easy to apply. In addition, Series resistor is used short circuit method for reduce the power loss. In improved efficiency and the laboratory environment for secure braking, resistance insert method and inverter output voltage increase method showed same characteristics in all areas.

Algorithm of intelligent SPS with applying fast-valving and braking resistor (Fast-valving과 Braking resistor 적용을 통한 지능형 SPS 알고리즘 구현)

  • Kim, Kab-Yong;Yoon, Dong-Hee;Jang, Gil-Soo;Moon, Young-Hwan;Kim, Seog-Joo;Seo, Sang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.280-281
    • /
    • 2011
  • Special Protection Scheme(SPS) that operates scenarios about faults beyond the normally protective action is wide system protection technology for the purpose of wide areas protection. Therefore, the SPS focuses on the improvement of the power supply capability by protecting the system rather than protecting the system equipments. Since the SPS requires emergency operation, the operation schedule is set up in advance by analyzing various scenarios. Since the SPS's action scheme uses generator tripping and is a classical method it is presently the most powerful one. However, as the setting of SPS is set to the most severe disturbance, the scheme tends to trip more generators than required to prevent fault propagation. It is highly likely that tripping generator units to prevent fault propagation would result in difficulty of system management and possibility of load shedding. Accordingly, it is desirable that generators are connected to the system within the range that ensures system stability and intelligent SPS is currently under development to solve the problem being stated. In this paper, as a part of developing the intelligent SPS, application of the fast-valving and braking resistor scheme to the generators is being proposed and analysed to reduce the number of tripped generators.

  • PDF

Small Signal Stability Analysis of Doubly Fed Induction Generator including SDBR

  • Shawon, Mohammad Hasanuzzaman;Al-Durra, Ahmed;Caruana, Cedric;Muyeen, S.M.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.31-39
    • /
    • 2013
  • This paper presents small signal stability analysis of a doubly fed induction generator (DFIG) based wind farm including series dynamic braking resistor (SDBR) connected at the stator side. A detailed mathematical model of wind turbine, DFIG machine and converters and SDBR is presented in this paper to derive the complete dynamic equations of the studied system. Small signal stability of this system is carried out by modal and sensitivity analysis, participation factors and eigenvalue analysis. Finally, this paper presents an analysis of the dynamic behavior of DFIG based wind farm under voltage dip condition with and without SDBR.

Design and Control of Braking Chopper Circuit for Ventilation Inverter of Traction Control System (고속전철용 추진제어장치의 냉각용 인버터를 위한 제동초퍼 회로 설계 및 제어)

  • Cho, Sung-Joon
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.314-315
    • /
    • 2011
  • This paper introduces the design and control method of braking chopper circuit which can supply input power to ventilation inverter of traction control system. The DC input voltage from auxiliary block (static inverter) is normally used as an input of ventilation inverter. It converts DC input to AC output voltage to drive cooling fans for traction control system and traction motors. The electrical braking force is very important for high speed train to guarantee safety even though the train is running in the dead section where the pantograph voltage is not supplied. When the high speed train decelerate speed in dead section, the regenerative energy is dissipated by braking resistor. This paper proposed the braking chopper control method to implement rheostatic braking function and the appropriate chopper circuit for supplying voltage source to ventilation inverter during rheostatic braking mode. The proposed chopper circuit makes it possible for traction control system to regenerate power continuously regardless of the existence of pantograph voltage. The feasibility of proposed braking chopper control and circuit were proven by inertia load test and actual train field test.

  • PDF

The Study on Source Current Control of the Voltage Source PWM Converter (전압형 PWM컨버터의 전원전류제어에 관한 연구)

  • Park, J.H.;Lee, C.D.;Gho, S.H.;Cho, Y.G.;Woo, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2037-2039
    • /
    • 1997
  • In this paper, a source current controlled-scope of the Voltage source PWM converter is considered from one-phase equivalent circuit. And for the improvement of transient characteristics the state quantity of bridge current that is returned from it's error is controlled. With the result of that the bridge current is controlled, this state quantity is known that it is a equivalent braking resistor.

  • PDF

The Performance Improvement of stopping for Induction Motor Using AC Drive (인버터를 이용한 유도전동기 감속 성능 개선)

  • Park, Kyeoung-Hun;Han, Kyung-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.296-297
    • /
    • 2011
  • Many applications involving induction motors that are controlled using variable frequency drives require the ability to stop quickly. These applications include emergency stops, quick stopping of fans, centrifuges, presses, etc. The technique that is widely accepted in the industry for achieving quick stopping makes use of brake resistors in series with a power semiconductor switch. The switch-resistor combination (brake-unit) is applied across the dc bus. The fastest decelerating time achievable depends on the size of the resistors and the switch employed. In this paper, the authors propose a novel method of achieving quick stopping times without the use of any brake-unit. Experimental test results with and without this method on a large inertia motor-load combination show that the proposed stopping method is able to reduce the stopping time significantly compared to normal decelerated stop without the need for a braking unit.

  • PDF

Development and Test of Inverter for Regenerative Power of DC Traction Power Supply System (직류급전시스템의 회생 전력 활용을 위한 인버터 시험설비 개발 및 성능시험)

  • Kim, Joo-Rak;Han, Moon-Seob;Kim, Yong-Ki;Kim, Jung-Hoon
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.2
    • /
    • pp.254-259
    • /
    • 2009
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. Electric multiple (EMU) in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMU on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system and the replacement cycle of brake shoe in EMU will be increased and dust due to mechanical braking decreased. This paper present the developed inverter for regenerative power and its test equipment. Test for developed inverter is performed at test equipment and is divided into three items, which are regeneration mode, active filter mode, and system link test.