• Title/Summary/Keyword: Bone Mineral Density (BMD)

Search Result 514, Processing Time 0.035 seconds

Synergic Effects of Mixed Formula Consisted of Polycan and Calcium-gluconate on the Experimental Periodontitis and Alveolar Bone Loss in Rats

  • Lee, Won-Ho;Kim, Kyung Hu;Kang, Su Jin;Lee, Young Joon;Ku, Sae Kwang
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.125-138
    • /
    • 2014
  • Objective : Polycan, exopolymers purified from Aureobasidium pullulans SM-2001 and calcium gluconate have been showed favorable inhibitory effects on the periodontitis and related alveolar bone losses through antioxidant and anti-inflammatory activities, respectively. In the present study, we intended to observe the possible synergic effects of mixed formula consisted of Polycan and calcium gluconate on ligation-induced experimental periodontitis and related alveolar bone losses in rats, and to select the fittest compositions for further developing as effective agents to ameliorate periodontal diseases. Method : Experiments were conducted as two separated two tests - first is synergic effects of Polycan and calcium gluconate 1:1, 1:9 and 9:1 mixtures, and second is 1:99, 2:98, 4:96, 8:92 and 1:9 mixtures. Experimental periodontal diseases were induced by ligature placed around the cervix of upper left incisior teeth of rats. One day after ligation placements, 200mg/kg of each single or mixed formulas of Polycan or/and calcium gluconate were orally administered for 10 days. The changes on the alveolar bone loss index and maxillary bone mineral density (BMD) were observed for detecting alveolar bone losses, and for anti-inflammatory effects, myeloperoxidase (MPO) activities and proinflammatory cytokine (tumor necrosis factor; TNF-${\alpha}$) contents were also evaluated in gingival tissues around ligature placed incisior teeth. The results of mixtures were compared with those of singe Polycan and calcium gluconate treated rat. Results : Each single or mixed formulas of Polycan or/and calcium gluconate favorably and significantly inhibited the inflammatory changes. The inhibitory effects of mixed formula consisted of Polycan and calcium gluconate 1:9 showed against periodontitis and related alveolar bone losses as compared with those of each Polycan and calcium gluconate single formula (p<0.05). In second experiment, Polycan and calcium gluconate 2:98, 4:96, 8:92 and 1:9 mixed formulas also showed significant increased anti-inflammatory and inhibitory effects against alveolar bone losses as compared with those of each single formula. Among them, Polycan and calcium gluconate 2:98 showed the highest efficacy against to ligation-induced experimental periodontitis and related alveolar bone losses. Conclusion : The results obtained in this study suggest that appropriated mixtures of Polycan and calcium gluconate showed synergic inhibitory effects against ligation-induced experimental periodontitis and related alveolar bone losses in rats. Moreover, Polycan and calcium gluconate 2:98 showed the highest efficacies in this experiment, suggesting the fittest composition for further developing as effective agents to ameliorate periodontal diseases.

Effects of the Herbal-Acupuncture with Corni Fructus Extract at Eumgok(KI10) on Osteoporosis in Ovariectomized Mice (음곡(陰谷)(KI10) 산수유 약침이 난소적출 생쥐의 골다공증에 미치는 영향)

  • Kim, Kwang-Sung;Lee, Byung-Ryul;Yang, Gi-Young;An, Taek-Won;Yim, Yun-Kyoung
    • Korean Journal of Acupuncture
    • /
    • v.27 no.1
    • /
    • pp.63-85
    • /
    • 2010
  • Objective & Method: The purpose of this study is to investigate the effects of herbal-acupuncture with Corni Fructus extract (CF-HA) at Eumgok(KI10) on osteoporosis in ovariectomized (OVX) ddy mice. I carried out several experimental items to analyze the changes in body weight, uterine weight, uterus index, tibial length, the ash bone weight, tibial BMD, the levels of serum ALP, osteocalcin, Ca, P and the levels of tibial Ca, P, Ca/P ratio, and we performed histological and histomorphological analysis as well. Result: 1. CF-HA at Eumgok(KI10) significantly did not increase the level of bone mineral density in overiectomized mice. 2. CF-HA at Eumgok(KI10) significantly decreased the level of serum phosphorus in ovariectomized mice and sinificantly increased the level of serum calcium in ovariectomized mice. 3. CF-HA at Eumgok(KI10) significantly increased the levels of tibial calcium and phosphorus in ovariectomized mice. 4. CF-HA at Eumgok(KI10) significantly decreased the number of tibial osteoclast like cell in ovariectomized mice. 5. In the histomorphometric analysis of tibia, GPL(growth plate length) was significantly decreased by CF-HA at Eumgok(KI10) in ovariectomized mice. Conclusions: These results suggest that CF-HA at Eumgok(KI10) may have useful therapy effects on osteoporosis in ovariectomized mice.

Study on Oneself Developed to Apparatus Position of Measurement of BMD in the Distal Radius (자체 개발한 보조기구로 원위 요골의 골밀도 측정 자세 연구)

  • Han, Man-Seok;Song, Jae-Yong;Lee, Hyun-Kuk;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.419-426
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the difference of bone mineral density according to distal radius rotation and to develop the supporting tool to measure rotation angles. Materials and Methods : CT scanning and the measurement of BMD by DXA of the appropriate position of the forearm were performed on 20 males. Twenty healthy volunteers without any history of operations, anomalies, or trauma were enrolled. The CT scan was used to evaluate the cross sectional structure and the rotation angle on the horizontal plane of the distal radius. The rotational angle was measured by the m-view program on the PACS monitor. The DXA was used in 20 dried radii of cadaveric specimens in pronation and supination with five and ten degrees, respectively, including a neutral position (zero degrees) to evaluate the changes of BMD according to the rotation. Results : The mean rotation angle of the distal radius on CT was 7.4 degrees of supination in 16 cases (80%), 3.3 degrees of pronation in three cases (15%), and zero degree of neutral in one case (9%), respectively. The total average rotation angle in 20 people was 5.4 degrees of supination. In the cadaveric study, the BMD of the distal radius was different according to the rotational angles. The lowest BMD was obtained at 3.3 degrees of supination. Conclusion : In the case of the measurement of BMD in the distal radius with a neutral position, the rotational angle of the distal radius is close to supination. Pronation is needed for the constant measurement of BMD in the distal radius with the rotation angle measuring at the lowest BMD and about five degrees of pronation of the distal radius is recommended.

  • PDF

Studies on the Comparative Analysis Between GE Prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool (골절의 절대위험도 평가방법에서 GE Prodigy와 FRAX Tool의 비교분석에 관한 고찰)

  • Lee, Hwa-Jin;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Mu-Seok;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.137-142
    • /
    • 2009
  • Purpose: World Health Organization (WHO) have suggested that an individual's 10-year absolute fracture risk is more reliable than Bone Mineral Density (BMD) measurement as the predictor of osteoporotic fracture. In 2008, Fracture Risk Assessment Tool ($FRAX^{TM}$) was developed by WHO to evaluate fracture risk of patients based on individual's clinical risk factors. The purpose of this study is to offer the comparative analysis of the existing GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Materials and Methods: 201 women ($55{\pm}3.5$ years) underwent femoral neck BMD measurement using GE Prodigy. The 10-year probability (%) of hip fracture (or a major osteoporosis-related fracture) was estimated using T-scores of GE prodigy and $FRAX^{TM}$. We made a comparative analysis of these data using SPSS (Ver.12). Results: There was a significant difference statistically between T-score ($-0.52{\pm}0.97$) of GE prodigy and T-score ($-1.45{\pm}0.81$) of $FRAX^{TM}$ (r=0.977, p=0.000). Also, there was a significant difference statistically between a major osteoporosis- related fracture ($9.15{\pm}3.71$) of GE prodigy and a major osteoporosis-related fracture ($4.87{\pm}1.51$) of $FRAX^{TM}$ (r=0.909, p=0.000). Moreover, a statistically significant difference was found in the 10-year probability of hip fracture of GE prodigy ($1.56{\pm}1.48$) and of hip fracture ($0.53{\pm}0.61$) of $FRAX^{TM}$ (r=0.905, p=0.000). Conclusions: There was a significant difference statistically between GE prodigy and $FRAX^{TM}$ Tool in Absolute Fracture Risk Assessment Tool. Especially, T-score, a major osteoporosis-related fracture and the 10-year probability of hip fracture that were estimated using GE prodigy tended to show the higher results than one evaluated by $FRAX^{TM}$ Tool. In conclusion, $FRAX^{TM}$ Tool may provide a better tool. The application of $FRAX^{TM}$ Tool as a fracture predictor remains to be clarified.

  • PDF

Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers (골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.833-844
    • /
    • 2018
  • Dual energy X-ray absorptiometry is mainly used as an X-ray test method. For equipment manufactured GE and Hologic, cross-calibration analyses (CCA) of machines from the same manufacturer and between units from different manufacturers have been conducted, but the CCA of equipment manufactured in Korea are inadequate. Through CCA, we present a formula of the intersections between the Korean medical equipment company (KEC) with GE and Hologic manufactured DXA, and among the KEC DXA. The CCA was conducted for the European Spine Phantom on DXA from four KEC and three global medical equipment company (GEC) manufacturers. We compared bone mineral density (BMD) values and calculated the CCA equation by linear regression analysis. The standard-deviations (SD) of the BMD values were highest for the Dexxum T for the low, medium, and high spine, which were 0.030, 0.029, and 0.037, respectively. The smallest SD in the low and medium vertebrae were 0.005 and 0.004 for the Horizon Ci, respectively, and 0.005 for the Osteo Pro Max in the high vertebrae. Based on the intersection equations of the KEC DXA established in this study, CCA of various KEC DXA should be established for more accurate follow-up of BMD tests in clinical environments.

Lumbar Interbody Fusion Outcomes in Degenerative Lumbar Disease : Comparison of Results between Patients Over and Under 65 Years of Age

  • Jo, Dae-Jean;Jun, Jae-Kyun;Kim, Ki-Tack;Kim, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.5
    • /
    • pp.412-418
    • /
    • 2010
  • Objective : To evaluate the clinical and radiological outcomes of lumbar interbody fusion and its correlation with various factors (e.g., age, comorbidities, fusion level, bone quality) in patients over and under 65 years of age who underwent lumbar fusion surgery for degenerative lumbar disease. Methods : One-hundred-thirty-three patients with lumbar degenerative disease underwent lumbar fusion surgery between June 2006 and June 2007 and were followed for more than one year. Forty-eight (361%) were older than 65 years of age (group A) and 85 (63.9%) were under 65 years of age (group B). Diagnosis, comorbidities, length of hospital stay, and perioperative complications were recorded. The analysis of clinical outcomes was based on the visual analogue scale (VAS). Radiological results were evaluated using plain radiographs. Clinical outcomes, radiological outcomes, length of hospital stay, and complication rates were analyzed in relation to lumbar fusion level, the number of comorbidities, bone mineral density (BMD), and age. Results : The mean age of the patients was 61.2 years (range, 33-86 years) and the mean BMD was -2.2 (range, -4.8 to -2.8). The mean length of hospital stay was 15.0 days (range, 5-60 days) and the mean follow-up was 23.0 months (range, 18-30 months). Eighty-five (64.0%) patients had more than one preoperative comorbidities. Perioperative complications occurred in 27 of 133 patients (20.3%). The incidence of overall complication was 22.9% in group A, and 18.8% in group B but there was no statistical difference between the two groups. The mean VAS scores for the back and leg were significantly decreased in both groups (p < 0.05), and bony fusion was achieved in 125 of 133 patients (94.0%). There was no significant difference in bony union rates between groups A and B (91.7% in group A vs. 95.3% in group B, p = 0.398). In group A. perioperative complications were more common with the increase in fusion level (p = 0.027). Perioperative complications in both groups A (p = 0.035) and B (p = 0.044) increased with an increasing number of comorbidities. Conclusion : Elderly patients with comorbidities are at a high risk for complications and adverse outcomes after lumbar spine surgery. In our study, clinical outcomes, fusion rates, and perioperative complication rates in older patients were comparable with those in younger populations. The number of comorbidities and the extent of fusion level were significant factors in predicting the occurrence of postoperative complications. However, proper perioperative general supportive care with a thorough fusion strategy during the operation could improve the overall postoperative outcomes in lumbar fusion surgery for elderly patients.

The Effect of Hounsfield Unit Value with Conventional Computed Tomography and Intraoperative Distraction on Postoperative Intervertebral Height Reduction in Patients Following Stand-Alone Anterior Cervical Discectomy and Fusion

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung;Woo, Joon Bum;Kim, Young Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.96-106
    • /
    • 2022
  • Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24-70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.

Early Onset Subsequent Vertebral Compression Fracture after Percutaneous Verteroplasty (경피적 척추 성형술 후 조기에 발생한 새로운 척추 압박골절)

  • Kim, Jong-Kil;Choi, Byeong-Yeol;Park, Young-Chul;Kim, Dong-Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.24-29
    • /
    • 2019
  • Purpose: To evaluate the characteristics and the risk factors of early onset subsequent vertebral compression fractures after percutaneous vertebroplasty. Materials and Methods: A total of 44 patients, who had a new subsequent vertebral fracture after percutaneous vertebroplasty for an osteoporotic vertebral compression fracture between January 2013 and December 2015, were recruited. The patients were divided into two groups according to the onset period of subsequent fracture. The number of patients who had a fracture within 3 months following vertebroplasty were 22 cases (Group A); after 3 months were 22 cases (Group B). Variables, including age, sex, bone mineral density (BMD), body mass index (BMI), preexisting vertebral compression fracture, location of the initial fracture, intradiscal cement leakage, injected cement volume, restoration of vertebral body height, and correction of kyphosis, in the two groups were analyzed and compared retrospectively. Results: The age, sex, BMD, BMI, preexisting vertebral compression fracture, location of the initial fracture, intradiscal cement leakage, and correction of kyphosis were similar in the two groups. Both a greater volume of bone cement injected and a greater degree of vertebral height restoration contributed significantly to the risk of fracture within 3 months. Conclusion: The cement volume and degree of height restoration are risk factors for early onset fracture at the adjacent vertebrae after percutaneous vertebroplasty and close attention is needed during the follow-up period.

Relationship between Intake of Milk and Milk Products and Bone Health by Sex and Age-Group in Koreans - Using Data from the Korea National Health and Nutrition Examination Survey 2008~2011 (성별, 연령별에 따른 우유·유제품 섭취와 골 건강과의 관련성 - 2008~2011 국민건강영양조사 자료를 이용하여)

  • Baek, Sang Woo;Lee, Heon Ok;Kim, Hyun Ja;Won, Eun Sook;Ha, Young Sik;Shin, Yong Kook;Om, Ae Son
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.4
    • /
    • pp.513-522
    • /
    • 2017
  • This study was conducted to examine the relationships between milk and milk product intake and bone health. The data from the 2008~2011 Korean National Health and Nutrition Examination Survey (KNHANES) were used for data analysis. Subjects included 4,626 men and 6,144 women aged 19 to 64 years. Daily intake frequency of milk and milk products was obtained using a food frequency questionnaire and divided into two categories: less than one serving per day and more than one serving per day. Bone mineral density (BMD) values of total femur, femoral neck, and lumbar spine were compared based on daily intake frequency, and relationships between milk and milk product daily intake frequency and osteoporosis risk were evaluated based on logistic regression. In men aged 30~39, BMDs of total femur and femoral neck were significantly higher in the group that consumed milk more than one serving per day (P<0.05). Intake frequency of milk and milk products was also significantly related to both BMDs of total femur and femoral neck. The odds ratio (OR) for milk intake frequency (more than one serving per day) compared to intake frequency less than one serving per day was 0.36 [95% confidence interval (CI) 0.21~0.62], and the OR for milk and milk products intake frequency (more than one serving per day) was 0.49 (95% CI 0.28~0.86) in women aged 50~64. These results indicate that increased consumption of milk and its products is associated with reduced risk of bone health disease, and adequate intakes of milk and milk products might play an important role in maintaining optimum bone health. Further research on the causal relationship and dose-response association between milk intake and bone heath using prospective cohort data is required prior to applying the observed results to programs that prevent bone health problems.

Anti-osteoporotic Activity of Gojineumja Aqueous Extracts on the Ovariectomized Mice (난소적출 마우스에서 고진음자(固眞飮子) 물 추출물의 골다공증 개선 효과)

  • Cho, Su-Yun;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.4
    • /
    • pp.16-38
    • /
    • 2018
  • Objectives: The objective of this in vivo study is to observe the anti-osteoporotic activities of Gojineumja aqueous extracts (GJEJ) on the ovariectomized (OVX) mice as compared to those of risedronate sodium (RES). Methods: Thirty five days after bilateral OVX, GJEJ was orally administered, for 35 days once a day and then the changes on the body weight and gain during experimental periods, femur weights, bone mineral density (BMD), bone strength (failure load), mineral contents - calcium (Ca) and inorganic phosphorus (IP), histological profiles and histomorphometrical analyses at sacrifice were conducted with serum biochemistry - osteocalcin contents and bone specific alkaline phosphatase (BALP) activities. And the results of GJEJ were compared with RES orally administered OVX mice. Results: As a result of OVX, noticeable increase of body weight and gains and serum osteocalcin levels, decrease of serum BALP activities, femur weights, femur Ca and IP contents, BMD and strength were observed as compared to those of sham control mice, respectively. Also, the decrease of all histomorphometrical indices indicating the bone mass and structure, and the increase of indices about resorption were also detected in the femur of OVX control. However, these estrogen-deficient osteoporotic signs were significantly and dose-dependently inhibited by 35 days of continuous oral treatment of GJEJ, at dose levels of 500, 250 and 125 mg/kg, respectively. Especially, GJEJ 500 mg/kg showed favorable inhibitory activities against estrogen-deficient osteoporosis symptoms induced by OVX as comparable to those of RES 2.5 mg/kg. Conclusions: The results in this study suggest that oral administrations of GJEJ have clear dose-dependent favorable anti-osteoporotic activities in OVX mice.