• 제목/요약/키워드: Bond test

검색결과 1,569건 처리시간 0.028초

상이(霜異)한 Ceramometal System에 있어서 Nickel-Chromium합금과 도재(陶材)와의 결합강도(結合强度)에 관(關)한 비교실험연구(比較實驗硏究) (A Study of Bond Strength of Nickel-Chromium Alloys with Porcelain in Ceramometal System)

  • 김치영
    • 대한치과기공학회지
    • /
    • 제7권1호
    • /
    • pp.19-25
    • /
    • 1985
  • In oder to compare and measure bond strength of ceramometal system with use of ceramco porcelain powder including SnO2 and uni metal, Rexillium III, Vera Bond as non precious alloys manufactured for porecelain-metal restorations. Total 24 test sample were constructed. All Test sample were measured with a Mitutoyo micrometer graduated to 0.01mm. It is as follows measured of thickness 3.3mm(metal : 1.1mm, porcelain: 2.2mm), width 12mm, length 30mm(porcelain 12mm x 12mm), Compared maximum bending stress test. The results obtained were as follows: 1. Bond strength of each metal with ceramco porcelain powder showed statistical significance.(P<0.05) 2. Vera Bond and uni metal, uni metal and Rexillium III revealed no statistical Significance.(P>0.05) Vera Bond and Rexillium III showed statistical significance.(P<0.05) 3. The order of maximum bending stress was Rexillium III, uni metal, vera Bond. The order of bond strength ratio making bending stress was Vera bond, uni metal, Rexillium III.

  • PDF

Belite 시멘트를 이용한 고성능 콘크리트의 철근 부착성능 실험연구 (An experimental study on Bond strength of Reinforcing steel to High-performance Concrete using Belite Cement)

  • 조필규;김상준;강지훈;김영식;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.408-415
    • /
    • 1997
  • Bond strength of reinforcing bar to high-performance concrete using Belite cement is explored using beam end test specimen. The key parameters for the bond test are slump of concrete, top bar effect, and strength of concrete in addition to concrete covers. Specimen failed in the typical brittle bond failure splitting the concrete cover as the wedging action. The test results show that for the group with portland cement I using superplasticizer additional slump does not decrease the bond strength of the top bar is less than bond strength of bottom bar, but the top bar factor satisfy the modification factor for top reinforcement. The result also show that bond strength is function of square root of concrete compressive strength and cover thickness. More detailed evaluation will be conducted from the test specimen with high strength concrete using the belite cement.

  • PDF

FRP 복합체의 콘크리트에 대한 접착강도 시험방법 변수 연구 (Parametric Study on Test Method for Pull-off Strength of FRP Composite Material used in Strengthening RC Members)

  • 최기선;유영찬;이한승;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.222-225
    • /
    • 2006
  • Pull-off test is widely used to evaluate bond performance between concrete and FRP composite. However, reliability of experiment result declines due to many difference between test methods of each national standards. This study analyzed problems of various existing test methods for pull-off test and suggested standardized test method. In addition, since tensile strength of concrete is smaller than bond strength of epoxy resin, maximum bond strength of epoxy resin shall be limited within tensile strength of concrete. Alternative testing method, therefore, which decrease FRP adhesion areas than concrete adhesion areas is suggested to widen test range of bond strength in pull-off test. In the experimental results, bond performance can be estimated up to two times of tensile strength of concrete by reducing FRP adhesion areas by 1/3.

  • PDF

시험방법에 따른 신ㆍ구 콘크리트의 부착강도 특성 (Characteristics of Bond Strength with Measuring Methods of Concrete)

  • 장흥균;김성환;홍창우;윤경구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.597-600
    • /
    • 2003
  • The development and maintenance of a sound bond are an essential requirements of concrete repair and replacement. The bond property of a bonded overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials. This study compares the nipple pipe direct tensile test, flexural adhesion test, and core pull-off test with their test results. Substantial differences in the failure stresses of three test methods were attributed to their different geometries and loading conditions. From these comparison and investigation, core pull-off test was relatively good because the coefficient of variation values were about 2%. It would be suitable for use in-situ because of its simplicity and accuracy.

  • PDF

보강근과 콘크리트 사이의 해석적 부착모델 비교 (Comparison of Analytical Bond Models between Reinforcement and Concrete)

  • 유영준;박지선;박영환;김형열;유영찬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.33-36
    • /
    • 2005
  • This paper presents the comparison of the goodness-of-fit test of analytical bond models between concrete and steel or GFRP reinforcements. Bond test specimens were made by the CSA code and the rebars used in the test were steel and two kinds of GFRP rebar commercially utilized. The comparison of goodness-of-fit test for existing bond models and new proposed bond model was carried out by the least squares method. The result indicates that the new proposed bond model has better goodness-of-fit test than the existing ones.

  • PDF

AC / PCC 복합포장 경계면 재료의 부착 성능 평가 (Evaluation of Bond Performance for AC overlay on PCC Pavement)

  • 김동규;황현식;;류성우;조윤호
    • 한국도로학회논문집
    • /
    • 제18권5호
    • /
    • pp.1-9
    • /
    • 2016
  • PURPOSES : This study focuses on the evaluation of interface performance with varying surface texture and tack coat application in an asphalt overlay. METHODS : The evaluation is carried out in two phases: tracking test and interface bond strength test. Using an image processing tool, tracking test is conducted to evaluate the susceptibility of the tack coat material to produce excessive tracking during application. Using the pull-off test method, the bond strength test is performed to determine the ability of the interface layer to resist failure. RESULTS : Results show that the underseal application yields less tracking compared to other applications. However, the bond strength is barely within the minimum acceptable value. On the other hand, RSC-4 produces higher bond strength for all surface types, but the drying time is long, which produces excessive tracking. CONCLUSIONS : While underseal application may be suitable for a trackless condition, the bond strength is less appealing compared to the rest of the tack applications available. RSC-4 demonstrated a high and consistent bond strength performance, but more time is required for drying to avoid excessive tracking. Tack coat application and surface type combination produce varying results. Therefore, these should be considered when selecting suitable future tack coat application options.

콘크리트의 형상비 및 온도변화에 따른 부착강도 특성평가 (Evaluation of Bond Strength Properties with Changing the Aspect Ratio and Temperature of Concrete)

  • 김현석;정원경;오한진;박준영;김형배
    • 한국도로학회논문집
    • /
    • 제20권3호
    • /
    • pp.19-26
    • /
    • 2018
  • PURPOSES : The main purpose of this study is suggest of field bond strength evaluation method for more objective evaluation method through Evaluation of Bond Strength Properties with changing aspect ratio and temperature. METHODS : The evaluation is laboratory bond strength test. Using the core machine, the pull-off test method ; the bond strength test of interface layer the universal testing machine. RESULTS : As a result of the laboratory bond strength evaluation, it was verified that the bond strength by aspect ratio decreases linearly with increasing aspect ratio and the bond strength properties by temperature change existed at high and low temperature condition relative to odinary temperature condition. CONCLUSIONS : According to the results of laboratory bond strength evaluation, the field bond strength evaluation results suggest applying the proposed correction factor (0.8, 1.0, 1.4, 1.9) according to aspect ratio(0.5, 0.1, 1.5, 2.0), For more objective evaluation of the bond strength, it is analyzed that the evaluation value is within $6{\sim}32^{\circ}C$ and the result can be obtained within 5% of the coefficient of variation.

반복하중 하에서 부착응력-슬립 거동 실험적 연구 (Experimental Study of Bond Stress-Slip Behavior under Repeated Loading)

  • 오병환;김세훈;김지상;신용석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.215-218
    • /
    • 2003
  • To analyze a bond stress-slip behavior between a reinforcing bar and concrete under repeated loading, pull-out fatigue test was performed. Major variables were repeated stress levels and cycle numbers. Test specimen was taken repeated constant amplitude loading before it was fractured by pull-out test. Increments of bond strength and slip according to repeated stress level and cycle numbers were analyzed. On the basis of test results, Local bond stress-slip relationship under repeated loading were formulated

  • PDF

Experimental Observation on Bond-Slip Behavior between Concrete and CFRP Plate

  • Yang, Dong-Suk;Hong, Sung-Nam;Park, Sun-Kyu
    • International Journal of Concrete Structures and Materials
    • /
    • 제1권1호
    • /
    • pp.37-43
    • /
    • 2007
  • This paper discusses the failure mode of reinforced concrete beams strengthened with composite materials based on six experimental set-ups to determine the FRP-to-concrete bond strength. Interfacial bond behavior between concrete and CFRP plates was discussed. Shear test were performed with different concrete compressive strengths (21 MPa and 28 MPa) and different bonding length (100 mm, 150 mm, 200 mm, and 250 mm). Shear test results indicate that the effective bond length (the bond length beyond which the ultimate load does not increase) was estimated as $196{\sim}204\;mm$ through linear regression analysis. Failure mode of specimens occurred due to debonding between concrete and CFRP plates. Maximum bond stress is calculated as about $3.0{\sim}3.3\;MPa$ from the relationships between bond stress and slip. Finally, the interfacial bond-slip model between CFRP plates and concrete, which is governed debonding failure, has been estimated from shear tests. Average bond stress was about $1.86{\sim}2.04\;MPa$, the volume of slip between CFRP plate and concrete was about $1.45{\sim}1.72\;mm$, and the fracture energy was found to be about $1.35{\sim}1.71\;N/mm$.

에폭시 코팅 처리된 PS강선의 정착부착성능 실험 (Tests on Transfer Bond Performance of Epoxy Coated Prestressing Strands)

  • 유승룡
    • 콘크리트학회지
    • /
    • 제6권1호
    • /
    • pp.89-100
    • /
    • 1994
  • 프리스트레스 프리텐숀 보의 전달길이를 위하여 콘크리트의 변형율에 의하여 부착력을 계측하는 간접적인 방법을 일반적으로 사용하여 왔다. 이 트랜스퍼 실험은 실제 보에서 행하여지므로, 실제 상태의 정착부착력을 계측할 수 있다는 장점이 있으나, 최대 정착부착응력과 부착강비를 구하기 난해하며, 그 결과가 매우 분산되어 있으므로, 구조 설계자가 안전한 적정기준을 이해하고 선택하기 어렵다. 콘크리트의 변형을 측정하지 않아도 PS 강선의 정착부착 성능을 얻을 수 있는 대안을 소개하였다. 실제 보에서 PS강재의 긴장을 풀 때와 유사한 상황에서 정축부착 응력을 직접 구하였다. 하중재하부에서 풀려진 PS강선의 긴장력은 하중재하부쪽 강선의 단면증가를 가져오고, 콘크리트 블록에 정착부착력을 발생시키며, 다른 방향(고정부 쪽)으로 슬립을 유발시킨다. 두 개의 중공 로드셀로 양단하중을 최대 부착응력 또는 전면슬립이 일어날 때까지 계측하였다. 프리텐션 콘크리트보의 정착부착 길이를 구하기 위하여 이 방법을 기존의 트랜스퍼 실험방법과 병행하여 사용할 것을 제안한다.