DOI QR코드

DOI QR Code

Evaluation of Bond Strength Properties with Changing the Aspect Ratio and Temperature of Concrete

콘크리트의 형상비 및 온도변화에 따른 부착강도 특성평가

  • 김현석 ((주)한국건설품질시험연구원 R&D연구실) ;
  • 정원경 ((주)한국건설품질시험연구원) ;
  • 오한진 (한국도로공사 도로교통연구원) ;
  • 박준영 (한국도로공사 도로교통연구원) ;
  • 김형배 (한국도로공사 도로교통연구원)
  • Received : 2018.02.22
  • Accepted : 2018.05.28
  • Published : 2018.06.15

Abstract

PURPOSES : The main purpose of this study is suggest of field bond strength evaluation method for more objective evaluation method through Evaluation of Bond Strength Properties with changing aspect ratio and temperature. METHODS : The evaluation is laboratory bond strength test. Using the core machine, the pull-off test method ; the bond strength test of interface layer the universal testing machine. RESULTS : As a result of the laboratory bond strength evaluation, it was verified that the bond strength by aspect ratio decreases linearly with increasing aspect ratio and the bond strength properties by temperature change existed at high and low temperature condition relative to odinary temperature condition. CONCLUSIONS : According to the results of laboratory bond strength evaluation, the field bond strength evaluation results suggest applying the proposed correction factor (0.8, 1.0, 1.4, 1.9) according to aspect ratio(0.5, 0.1, 1.5, 2.0), For more objective evaluation of the bond strength, it is analyzed that the evaluation value is within $6{\sim}32^{\circ}C$ and the result can be obtained within 5% of the coefficient of variation.

Keywords

References

  1. American Concrete Pavement Association (2008). Guide to concrete overlays: Sustainable for Resurfacing and Rehabliltating Existing Pavement, Second Edition, ACPA Publication TB021.02P.
  2. Hong, G. H. (2003). Effect of Aspect Ratio in Direct Tensile Strength of Concrete, Journal of the Korea Concrete Institute, Vol.15 No.2. pp.246-253 (in Korean). https://doi.org/10.4334/JKCI.2003.15.2.246
  3. Jang, H. K., Hong, C. W., Jeong, W. K., Lee, B. H. and Yun, K. K. (2002). Proposal of bond strength evaluation method for bridge deck overlay, Korea Concrete Institute, Journal of 2002 Spring Conference, pp.349-354 (in Korean).
  4. Kim, H. S., Jin. C. S., Eo, S. H. (1999). Size Effect of Compressive Strength of Concrete for the Cylindrical Specimens Considering Strength Level, Journal of the Korea Concrete Institute, Vol.12 No.2 (in Korean).
  5. Kim, S. W., Jeong, W. K., Jang, H. K., Kim, K. H. and Yun, K. K. (2002). Appropriate Method of Concrete Pull-out Test for Measure Bond Strength between New and Existing Concrete. Korean Society of Road Engineers, Journal of 2002 autumn Conference, pp.133-138 (in Korean).
  6. Yun, K. K., Lee, J. H., Choi, S. L. and Kim, K. H. (2001). Bond Strength Properties of Latex Modified Concrete, Journal of the Korea Concrete Institute, Vol.13 No.5. pp.507-515 (in Korean). https://doi.org/10.22636/JKCI.2001.13.5.507