• Title/Summary/Keyword: Bond 식

Search Result 362, Processing Time 0.021 seconds

SHEAR BOND STRENGTH OF SELF-ETCHING ADHESIVES TO DENTIN AND SEM ANALYSIS (상아질에 대한 자가 산부식 접착제의 전단결합강도와 SEM 분석 비교)

  • Cho, Young-Gon;Roh, Kee-Sun;Kim, Soo-Mee;Lee, Young-Gon;Jeong, Jin-Ho;Ki, Young-Jae
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.3
    • /
    • pp.222-231
    • /
    • 2003
  • The purpose of this study was to compare shear bond strength and interfacial pattern of composite bond-ed to dentin using self-etching adhesive systems. Sixty extracted human molars with exposed occlusal dentin were divided into four groups and bonded with four adhesives and composites. Single Bond/Filtek Z 350(SB), Tyrian SPE-One-Step Plus/Aelitefil(TY), Prompt L-Pop/Filtek Z 250(LP), and One-Up Bond F/palfique Toughwell(OU). The results of this study were as follows; 1 Shear bond strength for OU was significantly lower than that of other groups(p<0.05). No significant difference was founded among SB, TY, and LP. 2. Failure modes to dentin showed adhesive and mixed for SB TY and LP, but them for OU showed adhesive in all spceimens. 3. Dentin-resin interface showed close adaptation for SB, TY, and LP, but it showed gap for OU. 4. The hybrid layers for TY, LP OU were thinner than that of SB. Adhesive layers were observed between composite and hybrid layer, which were 5 $\mu\textrm{m}$ thick for TY and 10 $\mu\textrm{m}$ thick for OU.

Bond Properties of GFRP Rebar in Fiber Reinforced Concrete (Engineered Cementitious Composite) (섬유보강 콘크리트(ECC)와 GFRP 보강근의 부착 특성)

  • Choi, Yun-Cheul;Park, Keum-Sung;Choi, Chang-Sik;Choi, Hyun-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.809-815
    • /
    • 2011
  • An experimental investigations on the bond-slip properties of the steel and Glass Fiber Reinforced Polymer(GFRP) bars in engineered cementitious composite (ECC) with Polyvinyl Alcohol (PVA) fibers are presented. Total of 8 beam specimens prepared according to the Rilem procedures with 2% of PVA and PE fiber volume percentage and steel and GFRP reinforcements significantly changed the failure mechanism and slightly improved bond strength. The main objective of the tests was to evaluate the load versus displacement and load versus slip behaviors and the bond strength for the following parameters: concrete type (normal and fiber concrete) and bar diameter (10 and 13 mm). The study results showed that ordinary concrete and ECC specimens showed similar behavior for steel reinforced specimen. However, GFRP reinforced specimen showed different behavior that the steel specimen. The code analytical results showed more accuracy compared to the experimental results as expected in conservative code provisions. Based on the obtained results, it is safe to conclude that the new parameters need to be adopted to ensure safe usage of ECC for construction applications.

An Experiment on Bond Behaviours of Reinforcements Embedded in Geopolymer Concrete Using Direct Pull-out Test (직접 인발 시험을 이용한 지오폴리머 콘크리트의 부착 특성 실험)

  • Kim, Jee-Sang;Park, Jong-Ho
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.454-462
    • /
    • 2016
  • Geopolymer concrete is a new class of construction materials that has emerged as an alternative to ordinary Portland cement concrete to reduce the emission of $CO_2$ in the production of concrete. Many researches have been carried out on material developments of geopolymer concrete, however a few studies have been reported on the structural use of them. This paper presents an experiment on the bond behaviors of reinforcements embedded in fly ash based geopolymer concrete. The development lengths of reinforcement for various compressive strength levels of geopolymer concrete, 20, 30 and 40 MPa, and reinforcement diameters, 10, 16 and 25 mm, are investigated. Total 27 specimens were manufactured and pull-out test according to EN 10080 was applied to measure the bond strength and slips between concrete and reinforcements. As the compressive strength levels of geopolymer concrete increase, the bond strength between geopolymer concrete and reinforcement increase. The bond strengths decrease as the diameters of reinforcements increase, which is similar in normal concrete. Also, an estimation equation for the basic development length of reinforcement embedded in geopolymer concrete is proposed based on the experimental results in this study.

The Study of Milling Properties for Optimization of Treatment and Recycling of Converter Slag (제강슬래그 처리 및 재활용의 최적화를 위한 분쇄 특성에 관한 연구)

  • Kuh, Sung-Eun;Hwang, Kyoung-Jin;Kim, Dong-Su
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.6
    • /
    • pp.1139-1148
    • /
    • 2000
  • To treat and recycle a large quantity of converter slag. the milling properties of -14/ +24 mesh-sized slag has been considered. The optimal conditions in milling process were investigated for producing powder-type slag and the required consumption was derived for the economical grinding. The characteristics of milling processes were studied in the variation of the rotational speed, milling time, filling ratio of ball, and size and amount of feed. The grinding efficiency was also examined. The optimal rotational speed in this experimental condition was observed to be the value of 79% of critical speed. The extent of grinding was increased with increasing the grinding time. but the efficiency of milling was decreased with the time. 50% ball filling was shown to have the optimal grinding effect, and less amount and small-sized feed made the milling efficiency high. As the result, using Bond's equation, power required for efficient milling was considered and the highest value was observed in the condition of high grinding time and optimal rotational speed.

  • PDF

Balance Algorithm for Long-term Bond First of Cash Flow Matching Problem (자금흐름 일치 문제의 장기채권 우선 잔고 알고리즘)

  • Sang-Un Lee
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.3
    • /
    • pp.167-173
    • /
    • 2023
  • The cash flow matching problem(CFMP) aims to minimize the initial investment by paying the total amount due for the T-year in principal and interest of bonds or bank deposits without paying the full amount in cash. Linear programming(LP) is the only known way to solve CFMP. The linear programming method is a problem that optimizes T linear functions, and it cannot be solved by handwriting, so LINGO, which is a solution to the linear programming method, is used. This paper proposes an algorithm that obtains the solution of CFMP solely by handwriting without the help of LINGO. The proposed algorithm determines the amount of bond purchases by covering payments until the previous year of the next maturity bond in the order that the maturity date falls from the longest to the short term. In addition, until the year before the maturity of the shortest maturity bond, the amount of deposit covered by the principal and interest of the bank deposit was determined. As a result of applying the proposed algorithm to two experimental data, it was shown that more accurate results can be obtained compared to the linear programming method.

Effect of Different Types of Bonding Agent and Application Methods on Shear Bond Strength of Orthodontic Bracket (Bonding agent의 종류 및 적용 방법에 따른 교정용 브라켓의 전단결합강도에 관한 연구)

  • Lee, Jaehee;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.4
    • /
    • pp.419-426
    • /
    • 2017
  • Attachment of the orthodontic bracket conducted during the window opening procedure can result in failure due to various adverse conditions such as blood or saliva contamination, or other wet conditions. For the success of the bracket attachment, reduction of total operation time is crucial. The purpose of this literature is to evaluate the differences between the final resultant shear bond strength of the conventional method of using phosphoric acid and self-etching primer, and that of the operation time-reduced method in which the curing step is omitted subsequent to the primer application. A total of 40 human maxillary incisors were prepared. Group I(control group) and II were etched with 37% phosphoric acid and Group III and IV were conditioned with self-etching primer. Attachment of the group I and III was conducted by manufacturer's instructions. The operation time of Group II and IV was reduced by eliminating the curing step after the primer application. The resultant shear bond strength of each group was measured and an adhesive remnant index (ARI) was recorded. The mean shear bond strength of group I, II, III, and IV were 14.16 MPa, 8.33 MPa, 8.29 MPa, and 6.48 MPa respectively. Significant differences could only be found between the control group and the experimental groups (p < 0.05). The ARI indicated no significant difference among all groups.

AN EXPERIMENTAL STUDY ON THE BOND STRENGTH OF THE LIGHT ACTIVATED COMPOSITE RESIN BONDED TO THE ETCHED PORCELAIN (부식된 도재와 광중합성 수지와의 접합강도에 관한 실험적연구)

  • Lee, June-Kyu;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.363-378
    • /
    • 1987
  • 도재소부전장관에서 금속이 노출되지 않고 도재만이 파절시, 구강내에서 직접 행할 수 있는 심미적 수복 방법으로서 복합성 수지를 이용한 수복 방법이 널리 이용되고 있는데 본실험의 목적은 도재와 광중합성 수지간의 접합강도를 비교 측정코저 함에 있다. 본 실험에서는 주사전자 현미경을 사용하여 도재의 부식액 (5% 불화수소산용액, Excelco's porcelain etching gel) 및 부식 시간(2.5분, 5분, 10분, 20분)에 따른 부식양상을 먼저 관찰하였다. 그다음 각기 다른 시간에서 부식 처리된 도재와 대조군으로서 미부식 처리된 도재에 광중합성 수지를 부착시킬시, 첫째 Silane coupling agent(Scotch-Prime)도포후 광중합성 수지를 결합 시켰고 둘째 bonding agent(Scotch bond)도포후 광중합성 수지를 결합시켰으며 셋째 Silane coupling agent(Scotch-Prime)에 bonding agent(Scotch bond)를 도포후 광중합성 수지로 결합 시킨후, 인장강도 측정기 (Shimadzu universal testing machine)를 사용하여 결합력을 측정한 결과 다음과 같은 결론을 얻었다. 1. 부식처리된 도재가 미부식 처리된 도재 보다 결합력이 높았다. (p<0.05, P<0.001) 2. 부식 처리된 도재나 미부식 처리된 도재에 있어서 silane coupling agent 도포후 bonding agent로 처치한 경우 가장 결합력이 높았으며 그다음 silane coupling agent로 처치한 경우, bonding agent로 처치한 경우의 순이었다. 3. 도재부식 시간의 증가에 따른 결합력의 차이는 5% HF용액으로 부식 처리된 도재와 Excelco로 부식 처리된 도재에 있어서 5분 정도 까지는 결합력의 증가를 보였으나 그 후에는 결합력에 있어서 거의 증가하지 않는 양상을 보였다. 4. Excelco로 부식 처리된 도재와 5% HF 용액으로 부식처리된 도재간의 결합력 차이에 있어서 bonding agent만으로 처치한 경우에는 두결합력 사이에 서로 유의한 차이를 보이지 않았으나 (P>0.5) silane coupling agent만으로 처치한 경우와 silane coupling agent 도포후 bonding agent로 처치한 경우에는 두결합력 사이에 서로 유의한 차이를 보였다. (P<0.05, P<0.001) 5. Excelco로 부식처리된 도재가 5% HF 용액으로 부식처리된 도재보다 부식정도가 더 현저하였다.

  • PDF

A STUDY ON THE METAL SURFACE TREATMENT OF RESIN BONDED RETAINERS (산부식가공의치(酸腐植架工義齒)의 금속피착면(金屬被着面)에 관(關)한 연구(硏究))

  • Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.17-22
    • /
    • 1991
  • The purpose of this study was to evaluate the tensile bond strengths of treated alloy surfaces for resin bonded retainers. For the experiment metal surfaces of 5 alloys were teated with sandblasting, Silicoating Rocatec, and cemented with Visio-Gem. All specimens divided into two groups. The group I specimens were treated with 24-hour immersion in $37^{\circ}C$ distilled water, and group II specimens were teated with 1500 thermo-cycles from $5^{\circ}C\;to\;55^{\circ}C$. The obtained results were as follows: 1. Bond strength values showed significantly different between sandblasting group and other groups after a 24-hour immersion in $37^{\circ}C$ distilled water(P<0.05). 2. All samples were fractured during thermo-cycles for sandblasting group, and bond strength values for Silicoating and Rocatec groups showed significantly different after 1500 thermo-cycles from $5^{\circ}C\;to\;55^{\circ}C$.

  • PDF

Bond Characteristics of Glass Fiber Reinforced Polymer Rebar according to the Bar Location (GFRP 보강근의 단면 위치에 따른 부착특성)

  • Park, Ji-Sun;Park, Young-Hwan;You, Young-Jun;Hwang, Geum-Sic;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.197-200
    • /
    • 2006
  • The bond characteristics of three different types of glass fiber reinforced polymer(GFRP) reinforcing bars with different surface deformations were studied experimentally. Each specimen consisted of a concrete prism, 150 by 150 mm on each edge, with the longer axis in the vertical direction. Two rebars were embedded in each specimen, perpendicular to the longer axis and parallel to and equidistant from the sides of the prism. In vertical direction, one rebar was located at 75 mm from the bottom of the prism, and the other 225 mm from the bottom. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02.It was found that the bottom reinforcements showed higher bond stress than that of the top rebars.

  • PDF

In vitro cytotoxicity of self-etching primers (자가 산부식 프라이머의 세포독성에 관한 실험적 연구)

  • Rhee, Chang-Hoon;Kim, In-Ryeon;Kim, Gyoo-Cheon;Kim, Seong-Sik;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.422-433
    • /
    • 2006
  • Objective: Several ions and components are released from self-etching primers in the oral cavity. This may cause injury to the periodontal tissues throughout orthodontic treatment. The purpose of this study was to assess the cytotoxicity of self-etching primers to HGF-1, HaCaT, and RHEK cells. Method: Transbond XT Primer (3M Unitek, Monrovia, CA, USA), and self-etching primers, Clearfil SE Bond (Kuraray, Osaka, Japan), Transbond Plus SEP (3M Unitek, Monrovia, CA, USA), and Adper Prompt L-Pop (3M Unitek, Monrovia, CA, USA), were evaluated by MTT assay, and cellular changes were also observed. Results: In all cells after 72 hours with all primers, severe morphological changes such as atrophy and necrosis were observed. In the MTT assay using HGF-1, Clearfil SE Bond, Transbond XT Primer, Transbond Plus SEP, and Adper Prompt L-Pop were lined up in order of ascending cytotoxicity When using HaCaT, Clearfil SE Bond, Adper Prompt L-Pop, Transbond Plus SEP, and Transbond XT Primer were lined up in order of ascending cytotoxicity. When using RHEK, Clearfil SE Bond, Transbond XT Primer, Adper Prompt L-Pop, and Transbond Plus SEP were lined up in order of ascending cytotoxicity. Conclusion: The result of this study shows that care is needed because self-etching primers show cytotoxic properties similar to conventional primers.