• Title/Summary/Keyword: Bond 식

Search Result 362, Processing Time 0.029 seconds

Bonding efficacy of cured or uncured dentin adhesives in indirect resin (간접 레진수복시 상아질 접착제의 중합 여부에 따른 결합 효능)

  • Jang, Ji-Hyun;Lee, Bin-Na;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.6
    • /
    • pp.490-497
    • /
    • 2011
  • Objectives: This study examined the effect of the uncured dentin adhesives on the bond interface between the resin inlay and dentin. Materials and Methods: Dentin surface was exposed in 24 extracted human molars and the teeth were assigned to indirect and direct resin restoration group. For indirect resin groups, exposed dentin surfaces were temporized with provisional resin. The provisional restoration was removed after 1 wk and the teeth were divided further into 4 groups which used dentin adhesives (OptiBond FL, Kerr; One-Step, Bisco) with or without light-curing, respectively (Group OB-C, OB-NC, OS-C and OS-NC). Pre-fabricated resin blocks were cemented on the entire surfaces with resin cement. For the direct resin restoration groups, the dentin surfaces were treated with dentin adhesives (Group OB-D and OS-D), followed by restoring composite resin. After 24 hr, the teeth were assigned to microtensile bond strength (${\mu}TBS$) and confocal laser scanning microscopy (CLSM), respectively. Results: The indirect resin restoration groups showed a lower ${\mu}TBS$ than the direct resin restoration groups. The ${\mu}TBS$ values of the light cured dentin adhesive groups were higher than those of the uncured dentin adhesive groups (p < 0.05). CLSM analysis of the light cured dentin adhesive groups revealed definite and homogenous hybrid layers. However, the uncured dentin adhesive groups showed uncertain or even no hybrid layer. Conclusions: Light-curing of the dentin adhesive prior to the application of the cementing material in luting a resin inlay to dentin resulted in definite, homogenous hybrid layer formation, which may improve the bond strength.

ORTHODONTIC BRACKET SHEAR BOND STRENGTH TO Nd:YAG LASER Er:YAG LASER IRRADIATED ENAMEL (Nd : YAG 및 Er : YAG 레이저로 치아표면 조사시 브라켓 전단접착강도에 관한 실험적 연구)

  • Choi, Seung-Hoon;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.27 no.1
    • /
    • pp.141-155
    • /
    • 1997
  • The purpose of this study was to evaluate the effectiveness of the Nd:YAG laser and the Er:YAAG laser on etching enamel for direct bonding of orthodontic bracket. The advantages of laser etching rather than conventional acid etching are to reduce the subsurface demineralization rate, to inhibit the spillage of acid onto uninvolved ""its of enamel, and to save the clinical manipulation time involving drying, trashing and drying again. 189 freshly extracted human premolars were prepared for this research. 165 out of them were divided into 11 groups of 15 teeth. One group was acid etching and the rest groups were irradiated with Nd:YAG laser by four different energy levels(100mj 10pps, 100mj 20pps, 150mj 20pps, 200mj 20pps) and with Er:YAG laser by six different energy levels(60mj 5pps, 60mj 10pps, 100mj 10pps. 200mj 10pps, 200mj l5pps, 400mj 10pps). Shear bond strength was tested with Instron after 24 hours, one week, and three weeks. Twenty-four out of 189 teeth were divided into twelve groups untreated control, acid etching, and ten laser irradiation subgroups. And the ultrastructural enamel surfaces of each group were observed with scanning electron microscope. The results were as follows; 1. The means and the standard deviations of shear bond strength of Nd:YAG and Er:YAU laser irradiation by different energy levels were obtained. 2. Shear bond strengths of Er:YAG laser irradiation groups were higher than those of Nd:YAG laser irradiation groups at the identical energy level. 3. Maximum bond strengths was achieved at the energy of I50mj, 20pps in Nd:YAG laser irradiation groups or 60mj, 10pps in Er:YAG laser irradiation groups. 4. It was acceptible for direct bonding to irradiate lb0mj 20pps with Nd:YAG laser or to irradiate 60mj 10pps with Er:YAG laser considering the results of shear bond strength tests and SEM obsesvation.

  • PDF

Bond Behavior of Epoxy Coated Reinforced Concrete (에폭시수지 도막 철근콘크리트의 부착특성 연구)

  • 오병환;엄주용;권지훈
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.79-84
    • /
    • 1993
  • 철근의 부식은 철근 콘크리트 구조물에 있어서 심각한 열화현상을 유발할 수 있으며 최근 들어 이로 인한 피해가 많이 보고되고 있다. 이와 같은 부식의 억제방안 중 철근에 직접 에폭시를 도막하는 것이 가장 효과적인 것으로 알려져 있다. 그러나 이 경우 에폭시 도막에 따른 부착성능의 저하가 우려되는 바 본 연구는 철근부식방지를 위해 에폭시를 도막한 철근의 부착특성을 고찰하기 위해 수행되었다. 주된 변수는 콘크리트 압축강도, 부착길이, 에폭시 도막두께이며 각 변수별로 부착특성의 변화를 관찰하였고 이를 통해 에폭시도막 철근의 사용성을 검토하였다. 본 실험결과에 기초하여 부착강도 예측식을 제안하였고 실험결과와 예측치를 비교하였다.

  • PDF

Predicting the Screw Withdrawal Load of Commercial Particleboard Manufactured in Korea (국내에서 생산된 파티클보드의 나사못 유지력 예측)

  • Cha, Jae Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.544-550
    • /
    • 2013
  • Tests were carried out on commercial particleboards manufactured in Korea to evaluate and modify formulas which had previously been developed to predict the holding loads of screw on the face and edge of specimen. Screw sizes were No. 6, 8 and 10 used in this study. The withdrawal loads of screws were developed to predict as a function of screw diameter, depth of penetration, specific gravity and IB of particleboard. Predicted equations were fitted to the test results of different length of No. 8 screws. Results of tests indicate that IB is a better predictor of holding loads on the face of particleboard than SG. On the other hand, SG is a good indicator of holding load on the edge of particleboard.

Shear bond strength of orthodontic bracket with hydrophilic primer (친수성 프라이머를 이용한 교정용 브라켓 접착시의 전단결합강도에 관한 연구)

  • Park, Chul-Wan;Cha, Kyung-Suk;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.32 no.4 s.93
    • /
    • pp.293-300
    • /
    • 2002
  • The purpose of this study was to evaluate the clinical effectiveness of hydrophilic primer, which claim to retain adequate bond strength on moistened enamel resulting from moisture or saliva contamination, by comparing the shear bond strength and adhesive failure patterns of brackets bonded using hydrophilic primer and conventional hydrophobic primer. Brackets were bonded to human premolars embedded in metal cylinders utilizing light cured adhesive, primed with either a hydrophilic primer(Transbond fm primer) or a conventional hydrophobic primer(Transbond XT primer). Each sample was exposed to varying degrees of artificial saliva contamination during the priming process. The shear bond strength was measured using a universal testing machine, and the adhesive failure patterns after debonding were visually examined by strereomicroscope and assessed using the adhesive remnant index(ARI). The results were as follows 1. In dry conditions, no significant differences in shear bond strength between Transbond W and Transbond XT primers were found. 2. Transbond MIP primer exhibited a significantly higher shear bond strength than Transbond XT primer in saliva-contaminated conditions, regardless of the degree of contamination. 3. When contaminated with one coat of saliva, Transbond MIP primer did not exhibit significant differences in shear bond strength compared to the dry condition. When contaminated with two coats of saliva, Transbond MIP primer exhibited a singnificantly lower shear bond strength compared to the dry condition. 4. The adhesive remnant index of the adhesive failure pattern had a tendency to decrease, as the degree of saliva contamination increased. Bracket-adhesive interface failure was observed in more than half of the saliva contaminated samples utilizing Transbond MIP primer, whereas the bond failure sites of the Transbond XT primer samples occurred almost exclusively at the adhesive-enamel interface in saliva-contaminated conditions. The results of this study suggest that in cases where moisture control is difficult, Transbond MIP primer is an effective alternative to conventional hydrophobic primers.

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF

THE EFFECT OF THE REMOVAL OF CHONDROITIN SULFATE ON BOND STRENGTH OF DENTIN ADHESIVES AND COLLAGEN ARCHITECTURE (비교원성 단백질이 상아질 접착제의 결합강도와 교원질의 형태에 미치는 영향)

  • Kim, Jong-Ryul;Park, Sang-Jin;Choi, Gi-Woon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.211-221
    • /
    • 2010
  • Proteoglycan is highly hydrophilic and negatively charged which enable them attract the water. The objective of study was to investigate the effects of Proteoglycan on microtensile bond strength of dentin adhesives and on architecture of dentin collagen matrix of acid etched dentin by removing the chondroitin sulphate attached on Proteoglycan. A flat dentin surface in mid-coronal portion of tooth was prepared. After acid etching, half of the specimens were immersed in 0.1 U/mL chondroitinase ABC (C-ABC) for 48 h at $37^{\circ}C$, while the other half were stored in distilled water. Specimens were bonded with the dentin adhesive using three different bonding techniques (wet, dry and re-wet) followed by microtensile bond strength test. SEM examination was done with debonded specimen, resin-dentin interface and acid-etched dentin surface with/without C-ABC treatment. For the subgroups using wet-bonding or dry-bonding technique, microtensile bond strength showed no significant difference after C-ABC treatment (p > 0.05). Nevertheless, the subgroup using rewetting technique after air dry in the Single Bond 2 group demonstrated a significant decrease of microtensile bond strength after C-ABC treatment. Collagen architecture is loosely packed and some fibrils are aggregated together and relatively collapsed compared with normal acid-etched wet dentin after C-ABC treatment. Further studies are necessary for the contribution to the collagen architecture of noncollagenous protein under the various clinical situations and several dentin conditioners and are also needed about long-term effect on bond strength of dentin adhesive.

Crack Spacing in RC Tension Members Considering Cover Thickness and Concrete Compressive Strength (피복두께와 콘크리트 강도를 고려한 철근콘크리트 인장부재의 균열간격)

  • Kim, Woo;Lee, Ki-Yeol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.193-202
    • /
    • 2018
  • This paper proposed a crack spacing calculation formulation which is an important parameter for calculating the crack width, that is the main factor for verification of serviceability limit states and durability performance evaluation of reinforced concrete members. The basic equation of average crack spacing is derived by considering the bond characteristics which is the governing equation for the analysis of cracking behavior in reinforced concrete members. In order to consider the effect of the cover thickness and concrete compressive strength, the crack spacing measured in 124 direct tensile tests performed by several researchers was analyzed and each coefficient was proposed. And, correlation analysis was performed from 80 specimen data where the maximum and average crack spacing were simultaneously measured, and a correlation coefficient that can easily predict the maximum crack spacing from the average crack spacing was proposed. The results of the proposed average crack spacing equation and maximum crack spacing correlation were compared with those current design code specification. The comparisons of proposed equations and the Korean design codes show that the proposed formulation for the average crack spacing and the maximum crack spacing improves the accuracy and reliability of prediction compared to the corresponding provisions of the Korean Concrete Structural Design Code and Korean Highway Bridge Design Code (Limit States Design).

Influence of Sodium Hypochorite & EDTA on the Microtensile Bond Strength of Ethanol Wet Bonding (Ethanol Wet Bonding에서 NaOCl과 EDTA가 결합강도에 미치는 영향)

  • Kim, Deok-Joong;Song, Yong-Beom;Park, Sang-Hee;Kim, Hyoung-Sun;Lee, Hye-Yoon;Yu, Mi-Kyung;Lee, Kwang-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • Sodium hypochlorite and ethylene diamine tetra acetic acid are substances usually used during endodontic treatment. Several studies found that the bonding was negated with certain irrigants and some of the used irrigants have demineralizing and chealating effects, so it was advocated to omit the etching step in etch and rinse adhesive systems. The purpose of this in vitro study was to evaluate the influence of NaOCl & EDTA on the bonding strength of ethanol wet bonding. Thirty human molars were selected and mesiodistally sectioned into halves, thus providing sixty specimens. The specimens were randomly assigned to 4 groups(n=15) according to the irrigant regimen used : (1) irrigated with distilled water for 10min (control); (2) irrigated with 5.25% NaOCl(10min), flushed with 5.25% NaOCl(1min) (3) irrigated with 5.25% NaOCl, flushed with 17% EDTA (4) irrigated with 5.25% NaOCl, flushed with 17% EDTA. Each group was acid-etched with 37% phosphoric acid(except group 4) and had their dentin surfaces dehydrated with ethanol solutions : 50%, 70%, 80%, 95%, 3x100%, 30s for each application. After dehydration, a primer( 50% all bond 3 resin + 50% ethanol) was used, followed by the adhesive(ALL-BOND 3 RESIN) application. Resin composite build-ups were then prepared using an incremental technique. Specimens were sectioned into beams and submitted to a tensile load using a Micro Tensile Tester(Bisco Inc.). The data were statistically analyzed using one-way ANOVA and Tukey HSD at p<0.5 level. There was no significant difference on G1(control) and G2(irrigated with NaOCl only ). (p>0.05). G3(flushed with EDTA) showed significantly high tensile bonding strength compared to the G2 (p<0.05). G4( treated with EDTA but no acid-etching) was significantly lower value than G3. (p<0.05) Although there was no significant difference, 5.25% NaOCl seemed to have an adverse effect on the bonding strength of ethanol wet bonding. The flushing with EDTA after NaOCl irrigation prevents the decrease of bonding strength. The use of 17% EDTA as a final flush can enhance the bonding strength but EDTA flushing can't substitute for a acid-etching.

COMPARATIVE ENAMEL BOND STRENGTH BETWEEN LIGHT-AND DUAL-CURED COMPOSITES BONDED BY SELF-ETCHING ADHESIVES (자가 산부식 접착제로 접착된 광중합과 이원중합 복합레진의 법랑질 결합강도 비교)

  • Cho, Young-Gon;Yoo, Sang-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • This study compared the microshear bond strength (${\mu}SBS$) of light-cured and dual-cured composites to enamel bonded with three self-etching adhesives. Crown segments of extracted human molars were cut mesiodistally, and 1 mm thickness of specimen was made. They were assigned to three groups by used adhesives: Xeno group (Xeno III), Adper group (Adper Prompt L-Pop), and AQ group (AQ Bond). Each adhesive was applied to cut enamel surface as per manufacturer's instruction. Light-cured (Filtek Z 250) or dual-cured composite (Luxacore) was bonded to enamel of each specimen using Tygon tube. After storage in distilled water for 24 hours, the bonded specimens were subjected to ${\mu}SBS$ testing with a crosshead speed of 1 mm/minute. The mean ${\mu}SBS$ (n = 20 for each group) was statistically compared using two-way ANOVA, Tukey HSD, and t test at the 0.05 probability level, The results of this study were as follows ; 1. The ${\mu}SBS$ of light-cured composite was significantly higher than that of dual-cured composite when same adhesive was applied to enamel. 2. For Z 250, the ${\mu}SBS$ of AQ group ($9.95{\pm}2.51 MPa$) to enamel was significantly higher than that of Adper soup ($6.74{\pm}1.80 MPa$), but not significantly different with Xeno group ($7.73{\pm}2.01 MPa$). 3. For Luxacore, the ${\mu}SBS$ of Xeno group ($5.19{\pm}1.32\;MPa$) to enamel was significantly higher than that of Adper group ($3.41{\pm}1.19\;MPa$), but not significantly different with AQ group ($4.50{\pm}0.96\;MPa$).