• Title/Summary/Keyword: Boiling experiment

Search Result 181, Processing Time 0.033 seconds

A preliminary study on material effects of critical heat flux for downward-facing flow boiling

  • Wang, Kai;Li, Chun-Yen;Uesugi, Kotaro;Erkan, Nejdet;Okamoto, Koji
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2839-2846
    • /
    • 2021
  • In this study, experiments of downward-facing flow boiling were conducted to investigate material effects on CHF. Experiments were conducted using aluminum, copper, and carbon steel. It was found that different materials had different CHFs. Aluminum has the biggest CHF while copper has the lowest CHF for each mass flux. After experiment, surface wettability increased and surface became rougher, which was probably due to the oxidation process during nucleate boiling. The CHF difference is likely to be related to the surface wettability, roughness and thermal effusivity, which influences the bubble behavior and in turn affects CHF. Further studies are needed to determine which factor is dominant.

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

Comparison of DNA Extraction Methods for the Detection of Foodborne Pathogenic Bacteria from Livestock Manure Composts (퇴비에서 식중독균 검출을 위한 DNA 추출 방법 비교)

  • Kim, Sung-Youn;Seo, Dong-Yeon;Moon, Ji-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.6
    • /
    • pp.557-561
    • /
    • 2019
  • This study investigated the efficacy of DNA extraction methods for real-time PCR detection of foodborne pathogenic bacteria in livestock manure composts. Livestock manure composts were inoculated with Escherichia coli O157:H7, Salmonella Typhimurium, Listeria monocytogenes, Bacillus cereus and incubated in enrichment broth. For DNA extraction, enriched samples were treated following boiling method, by chloroform, C18 powder, and proteinase K. As a result, 4 species of bacteria were detected by real-time PCR when subjected to boiling for 30 min and treated with proteinase K. These results suggest that detection of foodborne pathogens by real-time PCR from livestock manure composts could be applicable using effective DNA extraction methodology such as the boiling method or proteinase K.

An Analysis of Textbooks and an Investigation of Science Teacher's Views on 'Boiling Point' and 'Melting Point' (끊는점과 녹는점에 대한 교과서 내용 분석 및 과학교사들의 인식조사)

  • Kim, Seong-Su;Baek, Seong-Hui
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.3
    • /
    • pp.252-264
    • /
    • 2002
  • In this study, the experimental apparatus for boiling point and melting point in science textbooks of various curriculums were analyzed. Science teachers' views on the difference between the experimental value and the value written in textbooks were inquired, too. Their views on the experimental apparatus, nd results of freezing point,melting point, boiling point, fractional distillation, and thermometer calibration were also investigated. The results of this study showed that the types of experimental apparatus for boiling point and melting point were somewhat dif-ferent with science textbooks and curriculum. The teachers' views were also various according to their background. In the experiment of the fractional distillat ion, a large number of teachers recognized mismatch between the exper-imental value and the value written in textbooks as mistake of textbook contents or problem of experiment itself. The teachers of chemistry background take higher recognition of the requirement of thermometer calibration than those of non-chemistry background in middle school.

A Study on the Effect of Fuel Boiling Point on Injection Characteristics at High Fuel Temperature Conditions (연료의 비등점이 고온상태 분사특성에 미치는 영향)

  • Lee, Hyung Ju;Choi, Hojin;Kim, Ildoo;Jeong, Byung-Hoon;Han, Jeong-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.2
    • /
    • pp.42-51
    • /
    • 2014
  • An experiment was conducted to study fuel injection characteristics of high boiling point test fuels (HBPTF), which are newly developed with higher boiling points than conventional aviation fuels, for various injection pressures when the fuel was heated to the temperature higher than their boiling points. The injection characteristics with elevating fuel temperature were quantified by the flow coefficient (${\alpha}$) and the cavitation number ($K_c$), and it was found that the trends between ${\alpha}$ and $K_c$ for various fuels were very similar with each other. In addition, compared with a conventional fuel, HBPTFs not only have higher fuel temperatures at which the effect of fuel boiling on the injection initiates, but also are less affected by the fuel boiling inside the injectors at temperatures over the boiling point.

Experiment on Piping in Pervious Foundation (투수성(透水性) 기초지반(基礎地盤)의 Piping에 관(關)한 실험(實驗))

  • Kwon, Moo Nam;Lee, Sang Ho
    • Current Research on Agriculture and Life Sciences
    • /
    • v.3
    • /
    • pp.44-54
    • /
    • 1985
  • In order to determine the critical head values of boiling and piping, several experiments were performed for 3 cases of model dykes on 7 kinds of pervious foundations. The results obtained are as follows : 1. It appears that the coarser and the denser the foundation material, the higher the critical heads of boiling and piping, and that the lower the permeability of the foundation, the higher the critical heads of boiling and piping. 2. A difference in head between the moments of boiling and piping is greater in the case 2 or case 3 than in the case 1 because of the additional hydraulic resistance. And it is found that the coarser the foundation material, the greater the head difference. 3. The critical heads of boiling and piping is directly prortional to the seepage length. 4. The piezometric heads close to the singular point are of the same magnitude, provided that the geometry of the model dyke and foundation material are the same. 5. Variations of the weight of model dyke can not affect the critical head. According to the conclusions shown above, the critical head of piping can be more practically predicted for prototype using the results from laboratory tests on scale model.

  • PDF

Visualization Experiment for Nucleate Boiling Bubble Motion on a Horizontal Tube Heater Fabricated with Flexible Circuit Board (연성회로기판 기반 수평전열관 표면의 비등기포거동 가시화 실험 연구)

  • Kim, Jae Soon;Kim, Yu-Na;Park, Goon-Cherl;Cho, Hyoung Kyu
    • Journal of the Korean Society of Visualization
    • /
    • v.14 no.2
    • /
    • pp.52-60
    • /
    • 2016
  • The Passive Auxiliary Feedwater System(PAFS) is one of the advanced safety concepts adopted in the Advanced Power Reactor Plus(APR+). To validate the operational performance of the PAFS, detailed understanding of a boiling heat transfer on horizontal tube outside is of great importance. Especially, in the mechanistic boiling heat transfer model, it is important to visualize the phenomena but there are some limitations with conventional experimental approaches. In the present study, we devised a heater based on the Flexible Printed Circuit Board (FPCB) for a more comprehensive visualization and subsequently, a digital image processing technique for the bubble motion measurement was established. Using the measurement technique, important parameters of the nucleate boiling are analyzed.

Experimental Study on Boiling Heat Transfer of the Tubes with Sintered Metal Surface for Freon-11 (냉매의 소결금속관 표면에서의 비등 열전달에 관한 실험적 연구)

  • Park C. J.;Mun B. S.;seo J. Y.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.10 no.3
    • /
    • pp.220-227
    • /
    • 1981
  • The purpose of this paper is to investigate the potential ability of sintered metal tube to promote heat transfer. In the experiment for Freon - 11, the boiling heat transfer on the sintered metal tube of bronze element is investigated and compared with that of the bronze tube (bare tube) atmospheric pressure. The experimental results are obtained as follows : 1) For sintered metal tubes of bronze element with particle diameters which ranges from $79({\mu})\;to\;461({\mu})$ and bare tube, boiling characteristic curves are expressed as : a) Sintered metal tube $$q{\propto}{\Delta}T^{1.05\~1.373}$$ b) Brae tube $$q{\propto}{\Delta}T^{3.096}$$ 2) Compared with that of the bare tube at low temperature difference$({\Delta}T_{sat})$, boiling heat transfer coefficient of the sintered bronze tube are relatively high. 3) There is tendency that curves of boiling heat transfer coefficients of sintered ·bronze tube and bare tube approach each other at rather high temperature difference. It is due to the increasing rate of the former heat transfer coefficient along with temperature difference is smaller than that of the latter. 4) Referring to particle diameter, optimum condition, i. e. , maximum heat transfer coefficient is found to be at approximately 2 mm thickness of sintered layer with $D_p=150({\mu})$.

  • PDF

Parametric study of population balance model on the DEBORA flow boiling experiment

  • Aljosa Gajsek;Matej Tekavcic;Bostjan Koncar
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.624-635
    • /
    • 2024
  • In two-fluid simulations of flow boiling, the modeling of the mean bubble diameter is a key parameter in the closure relations governing the intefacial transfer of mass, momentum, and energy. Monodispersed approach proved to be insufficient to describe the significant variation in bubble size during flow boiling in a heated pipe. A population balance model (PBM) has been employed to address these shortcomings. During nucleate boiling, vapor bubbles of a certain size are formed on the heated wall, detach and migrate into the bulk flow. These bubbles then grow, shrink or disintegrate by evaporation, condensation, breakage and aggregation. In this study, a parametric analysis of the PBM aggregation and breakage models has been performed to investigate their effect on the radial distribution of the mean bubble diameter and vapor volume fraction. The simulation results are compared with the DEBORA experiments (Garnier et al., 2001). In addition, the influence of PBM parameters on the local distribution of individual bubble size groups was also studied. The results have shown that the modeling of aggregation process has the largest influence on the results and is mainly dictated by the collisions due to flow turbulence.

An Investigation of Downcomer Boiling Effects During Reflood Phase Using TRAC-M Code

  • Chon Woo Chong;Lee Jae Hoon;Lee Sang Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1182-1193
    • /
    • 2005
  • The capability of TRAC-M code to predict downcomer boiling effect during reflood phase in postulated PWR LOCA is evaluated using the results of downcomer effective water head and Cylindrical Core Test Facility (CCTF) experiments, which were performed at JAERI. With a full height downcomer simulator, effective water head experiment was carried out to investigate the applicability of the TRAC-M best estimate LOCA code to evaluate the effective water head with superheated wall temperature in downcomer. In order to clarify the effect of the initial superheat of the downcomer wall on the system and the core cooling behaviors during the reflood phase, two sets of analysis were also performed with a CCTF. Results show that TRAC­M code tends to under-predict downcomer effective water head and core differential pressure. However, the code results show a good agreement with the experimental results in downcomer temperature, heat flux and pressure. Finally, both experiment and calculation showed that the downcomer water head with the superheated downcomer wall is lower than that of the saturated wall temperature.