• Title/Summary/Keyword: Blood pressure measurement system

Search Result 100, Processing Time 0.029 seconds

Physiological and Psychological Effects of Viewing and Walking in Forest and Urban Area (산림과 도심에서의 조망 및 보행활동이 인체의 생리·심리에 미치는 효과)

  • Ji, Gyeong-Bae;Kim, Kyeong-Nam;Han, Gab-Soo
    • Journal of Environmental Science International
    • /
    • v.21 no.5
    • /
    • pp.605-611
    • /
    • 2012
  • The purpose of this study is to analyze psychological and physiological effects accordance with viewing and walking in the forest and urban area. In the result of measurement of physiological reactions in nervous system, viewing of the forest had a calming effect on the nervous system by reducing blood pressure and heart rate. The other hand, viewing and walking in the urban area compared to the forest area raised stress by increasing blood pressure and heart rate. In addition, viewing in forest area was effective in stress relief by noticeable reduction of the amylase concentration. In contrast, walking in the urban area was also confirmed an increase of stress by increasing the concentration of the amylase. A viewing and walking in forest area was effective in alleviating depressed on anxiety, anger, fatigue and confusion.

A Study on Implemetation of Non-invasive Blood Pressure (비침습적 혈압 측정 시스템 구현에 관한 연구)

  • 노영아;이종수;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.451-454
    • /
    • 2000
  • Invasive methode and Non-invasive methode are used in blood pressure measurement. The Invasive methode can Set the correct measured blood pressure but, it has patient feels uncomfortable. So most of cases use Non-invasive methode. The Oscillometric method is commonly apply to modem electric sphygmomanometer and using various algorithm. In this paper describe about a algorithm it control and to determinate the cuff pressure, and filtering that data for measure the blood pressure. The communicating with personal computer can pressure deflation is by Solenoid valve and it uses RS-232 system in packet communication. The main using algorithm for blood pressure measurements are maximum amplitude algorithm and oscillometric algorithm. MAA(maximum amplitude algorithm) has various measured oscillation it depend on patient's age, height, weight and arm circumference size. In this paper, 1 studied the various measured oscillation apply to characteristic ratio and can get the result of systolic blood pressure, diastolic blood pressure, mean blood pressure. It was not used same ratio to measuring oscillation. In the MAA(maximum amplitude algorithm), we hope for reduce the difference with the real blood pressure and the measured blood pressure, when it applied with various specific ratio.

  • PDF

Design of Noninvasive Arterial Blood Pressure Measurement System by Using Double-Cuffs Oscillometric Method (이중 커프 오실로메트릭법을 이용한 비침습 동맥압 측정시스템의 설계)

  • Lee, Pil-Jae;Lee, Young-Jae;Kim, Dong-Jun;Lee, Jae-Ho;Lim, Min-Gyu;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.885-890
    • /
    • 2012
  • In this study, a new blood pressure measuring system was proposed and implemented. An additional small-cuff was placed on the center of a inner cuff to measure morphological signals and new oscillometric ratio. The proposed BP-measuring system is composed of an external cuff, an inner cuff and a small-cuff. Oscillation signal from small-cuff is interpolated with 7th-order fitting polynomials and SBP, DBP ratio were 22.2% and 87.7%. Experimental data were gathered from 20 volunteers ($25{\pm}4$ years) and arterial blood pressure values were compared with auscultation, sphygmomanometers, small-cuff and inner-cuff. As a result, the difference in systolic BP between auscultation and the small-cuff was 1.93(${\pm}1.28$) mmHg, and the inner-cuff was 4.53(${\pm}4.39$) mmHg, and sphygmomanometer was 6.68(${\pm}3.99$) mmHg, and the corresponding difference in diastolic BP was 2.50(${\pm}2.04$) mmHg, 3.50(${\pm}3.19$) mmHg, 7.35(${\pm}5.62$), respectively.

Effects of Samsaengyeum on the Cardiovascular System in the Experimental Animal (삼생음(三生飮)이 실험동물(實驗動物)의 심혈관계(心血管系) 및 혈류장애개선(血流障碍改善)에 미치는 효과(效果))

  • Jeon, Heui-Jun;Choi, Cheol-Won;Sin, Sun-Ho;Sung, Gang-Kyung;Mun, Byung-Sun
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.299-315
    • /
    • 1997
  • The present experiments were designed to investigate the effects of Samsaengyeum. water extracts on the Cardiovascular System in the Experimental Animals. Thus, the changes of blood pressure and heart rate were measured after oral administration. Measurement of Mortality rate was observed for measuring the effect of Samsaengyeum water extract Samsaengyeum water extract against pulmonary thromboembolism induced by collagen the mixture(0.1me/10g, 2mg/kg B.W) plus serotonin(5mg/kg B.W) in mouse. The effect of Samsaengyeiim water extract was examined by observing the change of collagen-induced platelet aggregation, coagulation activity, ex vivo and in vitro fibrinolytic activity of euglobulin fraction in rats. The results were summarized as followings. 1. Samsaengyeum dropped the blood pressure in spontaneous hypertensive rat. 2. The drug increased the auricular blood flow in rabbit. 3. The drug relaxed the artery contraction by pretreated norepinephrine in rat. 4. The drug inhibited the death rate of mouse which was led to thromboembolism by serotonin and collagen. 5. The drug inhibited the platelet aggregation in rat. 6. The drug prolonged the prothrombin time and activated partial thromboplastin time on the test of plasma coagulation factor activity in rat, but was not valuable. 7. The drug reduced the fibrinogen lyses time and increased the lyses area of rat. 8. Samsaengyeum reduced fibrinogen lyses time of rat in vitro assay. According to the above mentioned results, Samsaengyeum increased the blood flow and dropped the blood pressure by the dilation of blood vessel. And the drug inhibited the platelet aggregation.

  • PDF

Time-synchronized measurement and cyclic analysis of ultrasound imaging from blood with blood pressure in the mock pulsatile blood circulation system (박동 혈액 순환 모의 시스템에서 시간 동기화된 혈압 및 혈액의 초음파 영상 측정 및 주기적 분석)

  • Min, Soohong;Jin, Changzhu;Paeng, Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.361-369
    • /
    • 2017
  • Hemodynamic information in the carotid artery bifurcation is very important for understanding the development and progression mechanisms of cerebrovascular disease and for its early diagnosis and prediction of the progress. In this paper, we constructed a mock pulsatile blood circulation system using an anthropomorphic elastic vessel of the carotid artery bifurcation and ex vivo pig blood to acquire ultrasound images from blood and vessels synchronized with internal pressure while controlling the blood flow. Echogenicity, blood flow velocity, and blood vessel wall motion from the ultrasound images, and internal blood pressure were extracted over a cycle averaged from five cycles when the pulsatile pump rates are 20 r/min, 40 r/min, and 60 r/min. As a result, respectively, the peak systolic blood flow velocities were 20 cm/s, 25 cm/s, and 40 cm/s, the blood pressure differences were 30 mmHg, 70 mmHg, and 85 mmHg, the arterial walls were expanded to 0.05 mm, 0.15 mm, and 0.25 mm. Time-delayed cyclic variation of echogenicity compared to blood flow and pressure was observed, but the variation was minimal at 20 r/min. Time-synchronized cyclic variations of these parameters are important information for accurate input parameters and validation of the computational hemodynamic experiments which will provide useful information for the development and progress mechanisms of carotid artery stenosis.

The Effects of Samsoeum Extracts on Regional Cerebral Blood Flow and Blood Pressure in Mice (삼소음(蔘蘇飮)이 백서(白鼠)의 국소뇌혈류량(局所腦血流量)과 혈압(血壓)에 미치는 영향(影響))

  • Park, Byong-Min;Hong, Jae-Eui;Ko, Young-Chul;Shin, Jo-Young;Lee, Si-Hyeong
    • The Journal of Internal Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.33-39
    • /
    • 2002
  • Objective : The objective of this study is to measure the changes of regional cerebral blood flow(rCBF) and blood pressure(BP) in rats with the following injection. Methods : The measurement was continually monitored by laser-doppler flowmeter-Transonic Instrument, USA- and pressure tranducer(Grass, USA) in anesthetized adult Sprague-Dawley rats about for two hour to two hour and a half hours through the data acquisition system composed of Maclab and Macintosh computer. Result : This experiment with Samso-eum increased the changes of rCBF in rats, significantly, but did not change the blood pressure. The rCBF of Samso-eum decreased by pretreated propranolol, and was not changed by pretreated L-NNA and ODQ. Conclusion : It is considered that the dosage-dependent increase on rCBF is mediated by adrenegic ${\beta}$-receptor.

  • PDF

Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor (토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가)

  • Jung, Chang Jin;Jo, Jung Hee;Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

Development of continuous blood pressure measurement system using ECG and PPG (ECG와 PPG를 이용한 실시간 연속 혈압 측정 시스템)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Nam, Ki-Chang
    • Science of Emotion and Sensibility
    • /
    • v.11 no.2
    • /
    • pp.235-244
    • /
    • 2008
  • This study is to develop automatic extraction system of continuous blood pressure using ECG (Electrocardiogram) and PPG(Photoplethysmography) for u-health care technology. PTT (Pulse Transit Time) was determined from peak difference between ECG and PPG and its inverse made to get blood pressure. Since the peaks were vulnerable to be contaminated from noise and variation of amplitude, this study developed the adaptive algorithm for peak calculation in any noise condition. The developed method of the adaptive peak calculation was proven to make the standard deviations of PPT decrease to 28% and the detection of noise increase to 18%. Also, the correlation model such as blood pressure = -0.044 $\cdot$ PTT + 133.592 has successfully been determined for predicting the continuous pressure measured without using cuff but with using PPG and ECG, only.

  • PDF

Human Sensibility Measurement for the Visual Picture Stimulus (장면 시자극에 대한 감성측정에 관한 연구)

  • 김동윤;김동선;권의철;임영훈;손진훈
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1997.11a
    • /
    • pp.85-89
    • /
    • 1997
  • We present several biosignal measurement results and analysis algorithms for the visual stimulus from International Affective Picture Sytem. Sine human body is nonlinear dynamic system, we investigated both linear and nonlinear methods. We found that the alpha wave of EEG, the chaos of peripheral blood pressure, the LF/HF of HRV and thd retutn map of RR interval were good parameters for the measuremet of human sensibility. These can be used as the parameters for the measurement of human sensibility.

  • PDF

Development of ECG-NIBP Patient Monitoring System (ECG-NIBP 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.315-318
    • /
    • 1997
  • The ECG-NIBP patient monitor consist of Noninvasive Blood Pressure(NIBP) module that have micro controller inside. This module transfer data by serial communication to the main processor. This system apply the fuzzy inflating method to reduce the blood pressure measuring time, and moving artifact removing algorithm, several parameters used or more accurate measurement. The ECG monitor use the Digital Signal Processor(DSP) or digital filtering, peak detection, heart rate calculation. This system also offer convenient user interface by rotary key, menu bar. With 7" CRT display, auxiliary TFT LCD display adapted to display information on wide screen.

  • PDF