• Title/Summary/Keyword: Blood Simple

Search Result 509, Processing Time 0.027 seconds

Conventional Blood Conservation in Elective Cardiac Surgery (선택적 심장수술 환자에서 고식적 혈액 보존방법)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.108-114
    • /
    • 1993
  • The risks of homologous blood transfusion are well documented and recently increased with the emergence of acquired immunodeficiency syndrome. This is a report concerning 29 consecutive adult with no blood conservation patients (Group I) who had an elective cardiac operations. A similar group of 29 patients operated on 1992 but with blood conservation (Group II). In I of Group I patients and 15 of Group II patients, no homologous blood products were required. Group II patients used significantly less fresh frozen plasma (2.05${\pm}$0.68 unit versus 6.52${\pm}$0.72 unit, p<0.05) and the homologous blood transfusion (0.42${\pm}$0.9 unit versus 3.64${\pm}$0.17 unit, p<0.05) than Group I patients. Group II patients had also significantly less postoperative bleeding (338${\pm}$39.9 ml versus 585${\pm}$93.0 ml, p<0.05) than Group I patients. Group II patients recieved 460${\pm}$62.6 ml of mediastinal shed blood in acquired group. In conclusion, a simple and inexpensive blood conservation program, mainly combining autologous blood removal before bypass, retransfusion of the volume remaining in the oxygenator, and consistent autotransfusion of mediastinal shed blood has enabled us to avoid infusion of homologous blood in 15/29 patients of Group II patients. No side effects or complicatinos could be related to the blood conservation program.

  • PDF

Development of the Blood Glucose Strip for the Detection of Glucose in Blood (혈당 측정용 스트립 개발에 관한 연구)

  • 송은영;김경아;이홍수;권두한;남효진;김희정;변시명;정태화
    • Biomedical Science Letters
    • /
    • v.4 no.2
    • /
    • pp.103-112
    • /
    • 1998
  • We have developed a simple and accurate strip test that measures the blood glucose level semiquantitatively by visual observation, or qualitatively by using UltraScan spectrocolorimeter. The strip has solid phase reagents, including glucose oxidase, peroxidase, chromogen, affixed to a plastic support. The strip test is capable of measuring blood glucose level in the range of 0∼800 mg/dl and generating the results within 2 to 3 minutes. Human blood specimens obtained from normal individuals and the diabetic patients were evaluated by the new blood glucose strip and by the kit supplied by other commercial products. The test results exhibit the correlation coefficient of 0.964. The new test strip is proven simple and accurate, and it offers an alternative to the commercially available glucose tests.

  • PDF

Measurements of Blood Viscosity Using a Pressure-Scanning Slit Viscometer

  • Sehyun Shin;Lee, Sung-Woo;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.1036-1041
    • /
    • 2004
  • A newly designed pressure-scanning slit viscometer is developed to combine an optical device without refraction while measuring blood viscosity over a range of shear rates. The capillary tube in a previously designed capillary viscometer was replaced with a transparent slit, which is affordable to mount optical measurement of flowing blood cells. Using a pressure transducer, we measured the change of pressure in a collecting chamber with respect to the time, p(t), from which the viscosity and shear rate were mathematically calculated. For water, standard oil and whole blood, excellent agreement was found between the results from the pressure-scanning slit viscometer and those from a commercially available rotating viscometer. This new viscometer overcomes the drawbacks of the previously designed capillary viscometer in the measuring whole blood viscosity. First, the pressure-scanning slit viscometer can combine an optical instrument such as a microscope. Second, this design is low cost and simple (i.e., ease of operation, no moving parts, and disposable).

UNDERSTANDING OF NAVIER-STOKES EQUATIONS VIA A MODEL FOR BLOOD FLOW

  • Choi, Joon-Hyuck;Kang, Nam-Lyong;Choi, Sang-Don
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.11 no.1
    • /
    • pp.31-39
    • /
    • 2007
  • A pedagogic model for blood flow is introduced to help medicine majors understand a simplified version of Navier-Stokes equations which is known to be a good tool for interpreting the phenomena in blood flow. The pressure gradient consists of a time-independent part known as Hagen-Poiseuille's gradient and a time-dependent part known as Sexl's, and the model formula for the volume rate of blood flow is reduced to a very simple form. For demonstration, the blood rate in human aorta system is analyzed in connection with the time-dependence of pressure gradient. It is shown for Sexl's part that the flow rate lags the pressure gradient by ${\pi}/2$, which is thought to be due to the relaxation process involved.

  • PDF

Analysis of Residual Furan in Human Blood Using Solid Phase Microextraction-Gas Chromatography/Mass Spectrometry (SPME-GC/MS)

  • Lee, Yun-Kyung;Jung, Seung-Won;Lee, Sung-Joon;Lee, Kwang-Geun
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.379-383
    • /
    • 2009
  • For an accurate risk assessment of furan, a potential human carcinogen, levels must be determined in human blood plasma using a simple and robust assay. In this study, solid phase microextraction-gas chromatography/mass spectrometry (SPME-GC/MS) was used to analyze blood plasma levels of furan in 100 healthy individuals who consumed a normal diet. The subjects were 30 to 70 years of age and 51% were women. Ultimately, an analytical method was established for analyzing furan in human blood. The limit of quantification (LOQ) and furan recovery rate in blood were 1.0 ppb and 104%, respectively. Finally, furan was detected in 21 individuals (13 males, 8 females) with levels ranging up to 17.86 ppb (ng furan/g food).

Nonconstrained Blood Pressure Measurement by Photoplethysmography

  • Yoon Young-Zoon;Yoon Gil-Won
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.91-95
    • /
    • 2006
  • Blood pressure was predicted from photoplethysmography (PPG). To obtain PPG, backscattered light from a fingertip was measured and its waveform was analyzed. Systolic upstroke time and diastolic time in the pulse waveform were used as parameters to predict blood pressure. The experiment was carried out with five subjects on five different days. The systolic upstroke time had a correlation coefficient of -0.605 with respect to systolic blood pressure and the diastolic time had a correlation coefficients of -0.764 for diastolic pressure. This PPG method does not require an air-cuff installation on the arm and can predict blood pressure continuously. This simple LED/photo detector setup can be a good candidate for nonconstrained monitoring of blood pressure variations.

Blood Lead Concentration of Lead-Soldering Handicapped Workers in Manufacturing Electronic Components (전자부품제조 납땜 취급 장애인 근로자들의 혈중 납 농도)

  • Lee, Kook-Sung
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.2
    • /
    • pp.67-75
    • /
    • 2009
  • In order to provide basic data for the prevention of adverse effects of lead on health, we examined lead levels in the blood of 30 handicapped workers employed in manufacturing electronic components in Seoul from 2002 to 2008. The average lead level in the blood of all the subjects was $4.79{\pm}4.32{\mu}g/dL$ in females, $2.64{\pm}2.31{\mu}g/dL$ in males, and $3.88{\pm}3.75{\mu}g/dL$ in total. Lead levels examined in this study were significantly lower than other investigators study have reported. The average lead level from personal exposure of the subjects was $1.44{\pm}0.91mg/m^3$ in the workplace. The relation between blood lead levels and personal exposure was a simple linear regression; it's equation was "Lead level in blood = 6.04 - 1.92 lead level by personal exposure".

  • PDF

On a Reading Aloud to Relieve the Decrease in Blood Oxygen Saturation when Jogging

  • Tian, Zhixing;Bae, MyungJin
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.95-100
    • /
    • 2020
  • Recently, the problem of hypoxia caused by jogging is attracting attention. To solve this problem, this paper proposed a new solution. This paper proved that as a vocalization method of reading aloud, it is possible to increase air intake and activate lung function to exchange more air and obtain more oxygen. Then, blood oxygen saturation was used as an evaluation index for the body's oxygen content level to prove its effectiveness. A photoelectric pulse oximeter developed on the basis of different light absorption principles in blood was used to test blood oxygen saturation. Experimental results show that a certain degree of hypoxia is induced when a lot of oxygen is required due to jogging. Therefore, it was proved that the new vocal breathing method by reading books can increase the blood oxygen saturation of the body and improve the hypoxia of the body. Reading vocal breathing is a simple and efficient oxygen saturation recovery breathing method.

A new approach to quantify paraquat intoxication from postmortem blood sample by using 1H qNMR method

  • Hong, Ran Seon;Cho, Hwang Eui;Kim, Dong Woo;Woo, Sang Hee;Choe, Sanggil;Kim, Suncheun;Hong, Jin Tae;Moon, Dong Cheul
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.17 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • For a case study of suspected paraquat intoxication, we developed a simple and rapid method of $^1H$ qNMR to determine the mili-molar amount of paraquat in postmortem blood samples. There were no interfering signals from endogenous compounds in the chemical shift of paraquat and diquat (internal standard). The amount of sample used ranged from 0.25 mM to 10.0 mM. Diquat, which has similar physicochemical properties with paraquat, was chosen as an internal standard. The NMR experimental conditions, relaxation delay time and CPMG spin-echo pulse sequence were optimized. The developed method was validated in terms of specificity, accuracy, precision, matrix effect, recovery, limit of detection (LOD), and low limit of quantification (LLOQ). The proposed qNMR method provided a simple and rapid assay for the identification and quantification of the quaternary ammonium herbicide, "paraquat" in postmortem blood samples. This method was tested by using the blood from the heart of a man who was intoxicated with paraquat. In this particular case, the level of paraquat was 1.07 mM in the blood. For the determination of quaternary ammonium herbicides, qNMR could also be used to provide a better understanding of the currently available techniques.

Evalution of Hemolysis in Axial Flow Blood Pump with Computational Fluid Dynamics Analysis (전산유체해석을 이용한 축류형 혈액펌프의 용혈평가)

  • 임상필;김동욱
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.256-259
    • /
    • 2003
  • Artificial heart is divided pulsation style and nonpulsation style greatly according to flowing of blood. nonpulsation pump is advantage of miniaturization avaliable because it is simple and non-volumic-pump than pulsation pump. Non pulsation pump is derided axial flow style and centrifugal style accordig to rotating style. An axial flow blood pump can be made smaller than a centrifugal blood pump because of its higher specific speed. A hemolysis is an important factor for the development of an axial flow blood pump. It is difficult to identify the areas where hemolysis nun. Evaluation of hemolysis both in in vitro and in vivo require a long time and are costly. Computational fluid dynamics(CFD) analysis enables the engineer to predict hemolysis on a computer. The aims of this study is Computational fluid dynamics in the whole axial flow pump and to verify the accuracy of prediction results of CFD analysis compare with in vitro experimental results.

  • PDF