• Title/Summary/Keyword: Blood Flow Velocity

Search Result 289, Processing Time 0.03 seconds

Development of early diagnosis system for the detection of diabetic foot using photoplethysmograph (PPG를 이용한 당뇨병 환자의 족부질환의 조기진단 시스템 개발)

  • Kim Jin-Tae;Kim Sung-Woo;Hong Hyun-Ki;Im Jae-Joong;Kim Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.60-66
    • /
    • 2006
  • The purpose of this study was to suggest a new detection method for early diagnosing diabetic neuropathic foot by obtaining a ratio of toe to finger blood flow using photoplethysmography(PPG) and Laser Doppler(LD). Nerve conduction velocity (NCV) has been routinely used for diagnosing neuropathic foot, but it applies strong electric stimulus to peripheries resulting in stress and pain. The blood flow ratio of 50 neuropathic diabetes($0.96{\pm}0.20$) was significantly higher than that of 64 normal person($0.46{\pm}0.15$)(p<0.000). It also showed that toe temperature of neuropathic diabetes($30.5{\pm}1.4^{\circ}C$) was significantly higher than that of normal group($29.3{\pm}2.0^{\circ}C$)(p<0.000). The optimal boundary value of the blood flow ratio was found to be 0.678 and the sensitivity and specificity of this proposed method resulted in 95.3% and 95.3% respectively. Lastly, there were no neuropathic diabetes whose temperature difference between finger and toe was higher than $4.5\;^{\circ}C$.

Effects of local cold application on tissue & peripheral oxygen saturation, peripheral blood flow, skin temperature, and body temperature of healthy adult (국소적 냉 요법이 정상 성인의 조직과 말초의 산소포화도, 말초 혈류, 피부 온도, 체온에 미치는 효과)

  • Kim, Seung Ok;Shin, Yong Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.127-136
    • /
    • 2020
  • Purpose: This study aimed to establish a basis for application time and cold therapy interval by checking the physiological changes after applying a cold-gel and ice pack, commonly applied to cold therapy, and after passive rewarming. Method: A total of 22 healthy adults used cold-gel packs and ice packs in a Randomized control group repeated measurement study, and passive rewarming was performed for 40 minutes after 30 minutes of cold therapy. After applying to the right axilla, StO2, SpO2, peripheral blood flow, skin and body temperature were measured 15 times every 5 minutes. Result: In the cold-gel pack group, StO2 decreased from 69.43% to 61.06% after 30 minutes application, and in the ice pack group, StO2 decreased from 67.66% to 64.80% (p <001). In the cold-gel pack group, skin temperature decreased from 33.57℃ to 29.15℃ after 30 minutes application, and in the ice pack group, skin temperature decreased from 32.64℃ to 28.90℃ (p <.001). Only skin temperature recovered completely after 40 minutes of rewarming. There were insignificant differences between the cold-gel pack and ice pack. Conclusion: When applying cold therapy to the axillary, at least 40 minutes for passive rewarming is necessary after 30 minutes of application.

심근조영심초음파에서 심장의 움직임을 보정한 비침습적 심근관류모델의 정량적 평가

  • 이재훈;김희중;정남식;임세중;김기황
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.49-49
    • /
    • 2003
  • 목적 : 심초음파는 비침습적이므로 반복적으로 정확히 심질환의 경과를 관찰하여 치료효과 및 수술시기를 정할 수 있는 검사로서 임상적으로 매우 유용하다. 실시간 심근조영심초음파에 의한 time intensity 평가는 부위별로 수행됨으로 연속적으로 위치하는 관심영역이 intensity에 있어 심장의 움직임 변화에 영향을 받는다. Time intensity 곡선의 최적의 곡선맞춤을 위해 주기적인 심장 운동 매개변수를 조합해 기존의 모델을 보정한 안정적인 측정방법을 제시한다. 방법 : 심장의 운동에 의한 특징적인 정보를 설명하기 위해 기존의 문헌에 제시된 지수 함수에 주어진 심박수로 만들어진 시간에 관한 일반적인 정형파 함수를 추가한다. C(t) = A[1 - exp($\beta$t)] + Dsine(2$\pi$ft + $\theta$) C(t): videointensity A: plateau videointensity (blood volume) $\beta$: capillary blood velocity (rate constant of rise in videointensity) t: pulsing interval (ms) D: displacement from the periodic variance of the curve (estimated motion field from the ejection point for the ratio between systole and diastole) f: heart rate $\theta$: transit time issue A $\times$ $\beta$ : myocardial blood flow 관상동맥의 관류 데이터에 대한 실험이 펄스간격에 대한 비디오 세기로 수행되었다. 그리고 이러한 결과들이 the sum of squares due to error, R square, root mean squared error로 평가되었다. 결과 : 실험결과, 주기적인 심장의 움직임과 심박출 시점으로부터의 변위를 잘 기술하고 곡선에서의 측정 점들이 예측된 심장 움직임에 따라 성공적으로 표시되었다. 뿐만 아니라 보정된 모델이 현저한 적합도의 향상을 보여주었다. 결론 : 제시된 접근방법은 각각의 측정에서 심장 운동 영역의 변화에 독립적이며 측정 시점에 의해 영향받지 않고 심근 관류의 안정적인 측정이 가능하다. 심장의 움직임에 관한 매개변수를 조합한 모델로 곡선접합을 수행함으로써 관류의 정량적 정보를 좀더 정확하게 얻을 수 있으며 임상적 이용을 가능하게 할 것으로 기대된다.

  • PDF

Effect of Aqueous Extract of Polygoni Multiflori Radix on Hypertension and Arterial Contraction in Animal Models (하수오(何首烏)가 고혈압과 수축혈관에 미치는 영향)

  • Seo, Yong-Won;Kim, Ho-Hyun;Ko, Heung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.593-599
    • /
    • 2008
  • This research was aimed to examine the effect of Polygoni Multiflori Radix extract on the blood pressure in spontaneous hypertensive rat (SHR) and norepinephrine - induced arterial contraction in rabbit. In order to investigate the effect of Polygoni Multiflori Radix on rabbit's contracted vascular ring detached from common carotid artery, vascular ring with intact or damaged endothelium was used for the experiment using organ bath. To analyze the mechanism of Polygoni Multiflori Radix-induced relaxation, Polygoni Multiflori Radix extract was infused into contracted vascular ring which had been pretreated by $N{\omega}$-nitro-L-arginine(L-NNA), Methylene blue(MB), and $Ca^{2+}$ was infused into contracted vascular ring induced by NE after treatment of Polygoni Multiflori Radix extract in $Ca^{2+}$-free solution. The results were as follows: Systolic blood pressure was significantly attenuated by administration of Polygoni Multiflori Radix. Blood flow and aldosterone were significantly decreased, but velocity and renin were not affected by Polygoni Multiflori Radix. Polygoni Multiflori Radix had an effective relaxation to the contracted vascular ring by NE in 0.03 mg/ml, 0.1 mg/ml and 0.3 mg/ml level. Polygoni Multiflori Radix had an effective relaxation to the intact endothelium vascular ring, but when endothelium was removed, vascular ring did not relax. Polygoni Multiflori Radix-induced relaxation was inhibited by the pretreatment of L-NNA and MB. Pretreatment of Polygoni Multiflori Radix extract inhibit the contraction by influx of extra-$Ca^{2+}$ in contracted vascular ring induced by NE in $Ca^{2+}$-free solution. As mentioned above, we suggest that Polygoni Multiflori Radix relaxes vascular ring through suppress influx of extra-cellular $Ca^{2+}$ by the action of nitric oxide from endothelium.

Effects of DaeSiHo-Tang extract on Hypertension and Arterial Contraction (대시호탕(大柴胡湯)이 고혈압과 수축혈관에 미치는 영향)

  • Yeo Un-Hong;Jo Hak-Jun;Kim Ho-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.6
    • /
    • pp.1573-1579
    • /
    • 2005
  • This study was undertaken to define the effect of DaeSiHo-Tang extract on the hypertension in spontaneous hypertensive rat and norepinephrine-induced arterial contraction in rabbit. Systolic blood pressure and blood velocity were significantly attenuated by administration of DaeSiHo-Tang extract. but blood flow and renin-angiotensin-aldosterone system unaffected by DaeSiHo-Tang extract. The relaxation effect of DaeSiHo-Tang extract was dependent on the presence of endothelium, showing that DaeSiHo-Tang extract-induced relaxation was not observed in the strips without endothelium. The endothelium-dependent relaxation induced by DaeSiHo-Tang extract was decreased by the pretreatment of $N{\omega}$-nitro-L-arginine or methylene blue, but it was not observed in the strips pretreated with indomethacin or tetraethylammonium chloride. When $Ca^{2+}$ was applied, the strips which were contracted by norepinephrine in a $Ca^{2+}$-free solution, arterial contraction was increased. But pre-treatment of DaeSiHo-Tang extract inhibited contractile response to $Ca^{2+}$. These results indicate that antihypertensive effect of DaeSiHo-Tang extract is due to descend arterial resistance by the arterial relaxation through the formation of nitric oxide in the vascular endothelial cells.

A study on the Prevention of Deep Vein Thrombosis and Skin Response of Patients after Intracranial Surgery : By Boots and Calf Intermittent Pneumatic Compression Device (뇌수술 환자의 심부정맥혈전증 예방과 피부반응에 미치는 실험연구 : 부츠형과 무릎형의 간헐적 공기 압박기 적용에 따라)

  • Cho, Moo-Yong;Kim, Boon-Han;Kim, Ki-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.203-212
    • /
    • 2016
  • This study examined the prevention of deep vein thrombosis and skin response after the application of boots or calf intermittent pneumatic compression (IPC) devices in immobile patients with intracranial surgery. The subjects of this study included 60 patients in a surgical intensive care unit after receiving intracranial surgery from May to November in 2015. The blood flow velocity was measured daily to assess the deep vein thrombosis for 7 days, and the skin response of the legs was observed regularly. As a result, the boots IPC group showed an increased blood flow velocity over time compared to the calf IPC group. A significant statistical difference was observed in both the boots IPC group and calf IPC group over time (Right side; F=64.41, p<.001, Left side; F=58.21, p<.001). The dorsum circumference over time and the correlations between two groups (Right side; F=9.13, p <.001, left side; F=9.29, p<.001) also showed a significant difference. In addition, the boots IPC group showed no skin complications. In conclusion, the boots type IPC is a more effective method for preventing deep vein thrombosis for immobile patients with intracranial surgery.

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF

Effects of Acupuncture with a Combination of GV20 and EX-HN1 Acupoints on CO2 Reactivity in the Anterior and Middle Cerebral Arteries during Hypercapnia in Normal Subjects: A Randomized Crossover Trial

  • Park, Hojung;Moon, Sang-Kwan;Lee, Han-Gyul;Kwon, Seungwon;Cho, Seung-Yeon;Park, Seong-Uk;Jung, Woo-sang;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.4
    • /
    • pp.582-595
    • /
    • 2022
  • Objectives: To investigate the effects of acupuncture at GV20 and EX-HN1 on cerebral blood flow (CBF) velocity and cerebrovascular reactivity (CVR) in the middle cerebral arteries (MCA) and anterior cerebral arteries (ACA) and to compare the effects to acupuncture at GV20. Methods: The study was a randomized, crossover trial that included 10 healthy men aged 20 to 29 years who underwent acupuncture treatment four times with a washout period of one week. The CBF velocity and CVR were measured by transcranial Doppler sonography (TCD) on both MCAs at the first and second visits, and both ACAs at the third and fourth visits. Participants were randomly assigned to one of two groups (A and B) before the first and third visits. Group A received two phases of acupuncture intervention at a single GV20 point and a combination of GV20 and EX-HN1 acupoints. Group B received the same interventions, but in the reverse order. Results: The increase in CO2 reactivity was significantly higher for the combination acupoints of GV20 and EX-HN1 than for the GV20 single acupoint in both MCAs (Right: 136 to 178, p=0.017; Left: 127 to 191, p=0.017) and ACAs (Right: 133 to 158, p=0.013; Left: 122 to 168, p=0.025). No significant change was noted in the corrected velocity at PETCO2 40 mmHg, blood pressure, or heart rate. Conclusions: The findings suggest that improvement of the CBF in the MCA and ACA after GV20 acupuncture increases when acupuncture is also performed at EX-HN1. These results clinically support the combined use of EX-HN1 and GV20 to treat disorders of MCA and ACA circulation.

Study of Spectral Doppler Waveform Interpretation and Nomenclature in Peripheral Artery (말초 동맥 분광 도플러 파형 해석 및 명명법에 대한 고찰)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.649-660
    • /
    • 2022
  • In 1959, Satomura used spectral Doppler ultrasound to express the velocity of red blood cells according to time change, and Kato defined a zero-base line that could tell the direction of blood flow, making it possible to know the direction of blood flow. This became the basis for the widely used classifications of Triphasic, Biphasic, and Monophasic. However, the above classification has limitations that confuse users with the meaning and timing of use in a clinical environment. As a result, the American Society for Vascular Medicine (SVM) and the Society for Vascular Ultrasound (SVU) A consensus document on Doppler waveform analysis was declared by the joint committee. This study tried to review this consensus and to suggest nomenclature and modifiers that can be used in the domestic vascular ultrasound clinical field. The joint committee formed by SVM and SVU recommended that the use of the triphasic waveform and the biphasic waveform be used as a multiphasic waveform rather than being used due to the ambiguity of interpretation. In addition, it was agreed to name the hybrid-type waveform, which is a monophasic and high-resistance waveform, which has always been a problem of interpretation in a clinical environment, as an intermediate resistive waveform. In addition, in order to increase the communication efficiency between the interpreter and the sonographer, waveform analysis was classified into a main descriptor and a modifier, and it was recommended to use a single nomenclature by unifying various synonyms. It is expected that this literature review will provide accurate arterial spectral Doppler waveform interpretation and an agreed-upon nomenclature to radiologists performing vascular ultrasound examination in clinical practice, and will be utilized as basic data that can contribute to the improvement of public health.

A Study of Intracranial Hemodynamic Change with Aging (노화에 따른 두개내 혈류의 혈류 동력학적 변화에 관한 연구)

  • Kim Jong-Soon;Kim Byung-Jo;Bae Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.14 no.4
    • /
    • pp.119-130
    • /
    • 2002
  • The purpose of this study was to evaluate hemodynamics of intracranial blood flow for obtain clinically useful reference values and assess cerebral hemodynamics change with aging. 81 normal Korean subjects(age, 14$\thicksim\∼\thicksim$70 years) examined who han no history of neurologic disease and the subjects divided into group A(age, 14$\∼$39 years), group B(age, 40$\∼$59 years) and group C(age, 60$\∼$70 years). Transcranial doppler was use for measured the maximum velocity(Vmax), mean velocity(Vmean), pulsatility index(PI), resistive index(RI), stenosis index(SI) and depth of sample volume. Vmax was 99.1 1cm/s, Vmean was 63.57cm/s, PI was 0.85, RI was 0.56, SI was 31.94 and depth of sample volume was 52.35 in middle cerebral artery. Vmax was 85.54cm/s, Vmean was 52.52cm/s, PI was 0.82, RI was 0.55, SI was 34.48 and depth of sample volume was 73.62 in anterior cerebral artery. Vmax was 75.45cm/s, Vmean was 45.60cm/s, PI was 0.82, RI was 0.58, SI was 36.14 and depth of sample volume was 62.35 in posterior cerebral artery. Vmax was 70.44cm/s, Vmean was 47.07cm/s, PI was 0.87, RI was 0.58, SI was 29.83 and depth of sample volume was 75.23 in basilar artery Vmax was 63.92, Vmean was 42.42, PI was 0.89, RI was 0.58, SI was 29.89 and depth of sample volume was 66.65 in vertebral artery. Vmax and Vmean was significantly decreased with increasing age in middle cerebral artery, anterior cerebral artery, posterior cerebral artery, basilar artery and vertebral artery And PI and RI was significantly increased with increasing age in basilar artery and vertebral artery. And I suggest that transcranial doppler sonography can be used as one of useful clinical tool for detection of cerebral hemodynamics.

  • PDF