• Title/Summary/Keyword: Blood Chemical Analysis

Search Result 180, Processing Time 0.02 seconds

Spectroscopic and Electrochemical Detection of Thrombin/5'-SH or 3'-SH Aptamer Immobilized on (porous) Gold Substrates

  • Park, Buem-Jin;Sa, Young-Seung;Kim, Yong-Hwan;Kim, Young-Hun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.100-104
    • /
    • 2012
  • Thrombin is a serine protease that catalyzes the conversion of soluble fibrinogen to insoluble fibrin, and thus induces physiological and pathological blood coagulation. Therefore, it is important to detect thrombin in blood serum for purposes of diagnosis. To achieve this goal, it has been suggested that a 15-mer aptamer strongly binds with thrombin to form a G-quartet structure of the aptamer. Generally, 5'-end thiol-functionalized aptamer has been used as an anti-thrombin binder. Herein, we evaluate the possibility of utilizing a 3'-SH aptasensor for thrombin detection using SPR spectroscopy, and compare the enhancement of the electrochemical signal of the thrombin-aptamer bound on a porous gold substrate. Although the two aptamers have similar configurations, in SPR analysis, the 3'-SH aptamer was a effective aptasensor as well as 5'-SH aptamer. Results from electrochemical analysis showed that the porous gold substrate acted as a good substrate for an aptasensor and demonstrated 5-fold enhancement of current change, as compared to gold thin film.

Rapid Determination of Volatile Organic Compounds in Human Whole Blood Using Static Headspace Sampling with Gas Chromatography and Mass Spectrometry

  • Lee, Ji-Young;Kim, Seungki;Lee, Jong-Tae;Choi, Jong-Ho;Lee, Jeongae;Pyo, Heesoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.3963-3970
    • /
    • 2012
  • Headspace (HS) and headspace solid-phase microextraction (HS-SPME) were studied for extracting volatile organic compounds (VOCs) from whole blood, with chemical and instrumental variables being optimized for maximum sensitivity: incubation at $60^{\circ}C$, equilibration for 30 min, pH 11, and 2 mL injection volume. Both techniques provided accurate analyses, with detection limits of 0.05-0.1 ng $mL^{-1}$ and 0.05-0.5 ng $mL^{-1}$. HS showed better sensitivity, reproducibility, and analysis times than HS-SPME. Overall levels of chloroform in whole blood were found to be 0.05-5.84 ng $mL^{-1}$; detected levels of benzene were 0.05-2.20 ng $mL^{-1}$.

Determination of Ultra Trace Levels of Copper in Whole Blood by Adsorptive Stripping Voltammetry

  • Attar, Tarik;Harek, Yahia;Larabi, Lahcen
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.5
    • /
    • pp.568-573
    • /
    • 2013
  • A selective and sensitive method for simultaneous determination of copper in blood by adsorptive differential pulse cathodic stripping voltammetry is presented. The procedure involves an adsorptive accumulation of Cu(II)-ETSC (4- ethyl-3-thiosemicarbazide) on a hanging mercury drop electrode, followed by a stripping voltammetry measurement of reduction current of adsorbed complex at about -715 mV. The optimum conditions for the analysis of copper (II) ion are : pH 10.3, concentration of 4-ethyl-3-thiosemicarbazide $3.25{\times}10^{-6}$ M and an accumulation potential of -100 mV. The peak current is proportional to the concentration of copper over the range 0.003-125 ng/mL with a detection limit of 0.001 ng/mL and an accumulation time of 60 s. Moreover, with the use of the proposed method, there is a considerable improvement in the detection limit, the linear dynamic range and the deposition time, compared with the methods of adsorptive stripping voltammetry for the determination of copper. The developed method was validated by analysis of whole blood certified reference materials.

Diagnosis of Bovine Theileriosis by Direct PCR and Electrophoresis from Whole Blood Without DNA Extraction (DNA 추출없이 전혈을 이용한 PCR-전기영동법에 의한소의 타일레리아병 진단)

  • Seong Ho Kang;Sangmin Jang;Joon-Seok Chae;Yongseong Kim
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.127-132
    • /
    • 2003
  • We have developed a direct polymerase chain reaction (PCR) and electrophoresis method for the diagnosis of bovine theileriosis from whole blood DNA analysis without DNA extraction. The technique empolyed a FoLT (formamide, low temp.) technique and was utilized in the diagnosis of bovine theileriosis. Formamide solubilize the blood cells, and the lowered incubation temperatures reduced protein coagulation. 100-200 nL of whole blood and PCR reagents were introduced directly into a PCR tube. After the amplification, the PCR product (816-bp DNA) was introduced into the electrophoresis system. The results of this analysis were consist with those obtained using purified DNA.

In vitro investigation of algin impregnated vascular graft (알진이 도포된 인공혈관의 물성 평가)

  • Lee, Jin-Ho;Shin, Bung-Chul;Khang, Gil-Son;Lee, Hai-Bang
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.05
    • /
    • pp.9-12
    • /
    • 1990
  • He impregnated a highly porous, knitted polyester (Dacron) graft with a biodegradable nonproteinaceous material, algin. This new vascular graft is blood tight but still retains high porosity in the body. It does not need to be preclotted with blood before implantation and has good tissue ingrowth and biological healing properties due to the high porosity. The algin impregnated graft was investigated by "in vitro" examinations in this study. It was characterized by ESCA analysis, SEM observation, and measurements of water permeability, algin coating weight, mechanical properties and whole blood clotting time. The water permeability of the graft was reduced more than 99% by the algin impregnation treatment without changing any mechanical properties. "In vivo" examinations of the algin impregnated vascular graft are on progress.

  • PDF

Treatment for acute renal failure occurred by ingestion of grape skins in a dog (개에서 포도껍질 섭취 후 발생한 급성신부전 치료 증례)

  • Oh, Hyun-Wook;Jun, Hyung-Kyou;Choi, Ho-Jung;Lee, Young-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.48 no.2
    • /
    • pp.215-218
    • /
    • 2008
  • A 2-year-old, female, Maltese dog (3.2 kg of body weight) was referred to the Veterinary Medical Teaching Hospital, Chungnam National University with vomiting, anorexia and depression. Twelve hours prior to the onset of clinical signs, the dog ingested some grape skins (about 60 g). Physical examination at the time of presentation showed peripheral edema and mucous pallor. Blood and blood chemical analysis revealed anemia and moderate azotemia with elevated blood urea nitrogen (107.2 mg/dl), creatinine (6.3 mg/dl) and hyperphosphatemia (11.3 mg/dl). Echogenicity of renal cortex were observred by ultrasonography. The dog was diagnosed as acute renal failure occurred by grape skin toxicosis. The dog was treated with supportive care such as fluid therapy, diuretics (furosemide) and phosphorus binder (almagate). A normal condition of blood and blood chemical findings and clinical signs was observed at five days after treatment, and prognosis is good to date.

Construction of Membrane Sieves Using Stoichiometric and Stress-Reduced $Si_3N_4/SiO_2/Si_3N_4$ Multilayer Films and Their Applications in Blood Plasma Separation

  • Lee, Dae-Sik;Choi, Yo-Han;Han, Yong-Duk;Yoon, Hyun-C.;Shoji, Shuichi;Jung, Mun-Youn
    • ETRI Journal
    • /
    • v.34 no.2
    • /
    • pp.226-234
    • /
    • 2012
  • The novelty of this study resides in the fabrication of stoichiometric and stress-reduced $Si_3N_4/SiO_2/Si_3N_4$ triple-layer membrane sieves. The membrane sieves were designed to be very flat and thin, mechanically stress-reduced, and stable in their electrical and chemical properties. All insulating materials are deposited stoichiometrically by a low-pressure chemical vapor deposition system. The membranes with a thickness of 0.4 ${\mu}m$ have pores with a diameter of about 1 ${\mu}m$. The device is fabricated on a 6" silicon wafer with the semiconductor processes. We utilized the membrane sieves for plasma separations from human whole blood. To enhance the separation ability of blood plasma, an agarose gel matrix was attached to the membrane sieves. We could separate about 1 ${\mu}L$ of blood plasma from 5 ${\mu}L$ of human whole blood. Our device can be used in the cell-based biosensors or analysis systems in analytical chemistry.

Fiber-optic biosensor for analysis of glucose and lactate in blood samples (혈액중 포도당과 젖산의 분석을 위한 광섬유 생물센서)

  • Sohn, Ok-Jae;Rhee, Jong-Il
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.28-33
    • /
    • 2006
  • Optical-fiber sensors have been developed to determine the concentrations of glucose and lactic acid in blood samples. Fluorescence dye [tris(2,2'-biphenyridine)-ruthenium(II)-chloride (RuBPY)] was entrapped by using a silicon to the unclad tip of a glass optic fiber. Enzymes like glucose oxidase (GOD) and lactate oxidase (LOD) have been immobilized by acrylamide resin adhesive, adsorption with zeolite or covalent bonding with aminopropyl-triethoxysilan. The fiber-optic glucose/lactate sensor was then used to analyze the concentrations of glucose and lactate in blood samples. The results were compared with the results of HPLC analysis and their difference was in error by less then 5 %.

Analysis of Trace Level and Correlation of Lead in the Plasma of Field Workers and General Public by ICP-MS (유도결합플라즈마 질량분석법에 의한 납 취급 근로자와 일반인의 혈장 중 납 분석 및 상관성 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Kim, Nam-Soo;Lee, Byung-Kook;Shin, Ho-Sang
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 2013
  • Objectives: This study attempted to develop a method to measure ultra-trace lead concentrations in plasma using Inductively Coupled Plasma Mass Spectrometry(ICP-MS) and to test whether plasma lead can be used as a biomarker for the biological monitoring of exposure to lead. Methods: Lead concentrations in 160 plasma samples of field workers and 42 plasma samples from the control group were measured by ICP-MS. Blood zinc protophorphyrin(ZPP) concentrations and urinary ${\delta}$-aminolevulinic acid${\delta}-ALA$) were measured for correlation analysis with plasma lead. Results: The mean lead level in the plasma of the workers exposed to lead at work were 786.1 ng/L. Plasma lead levels were not correlated with blood ZPP or urinary ${\delta}-ALA$ concentrations. Otherwise, plasma lead levels showed a good correlation coefficient of 0.400 with blood lead levels, and their correlation coefficient had a better value of 0.552 for the non-smoking and drinking group. In the general population group which was not exposed to lead in the workplace and was considered the control group, the mean concentration of plasma lead was 123.1 ng/L. The plasma lead levels for the general population group showed a good correlation coefficient of 0.520 with blood ZPP and urinary ${\delta}-ALA$ concentrations.

Two New Flavonoids from Dragon's Blood of Dracaena cambodiana

  • Mei, Wen-Li;Luo, Ying;Wang, Hui;Shen, Hai-Yan;Zeng, Yan-Bo;Dai, Hao-Fu
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1791-1794
    • /
    • 2013
  • Phytochemical investigation on dragon's blood of Dracaena cambodiana led to the discovery of two new flavonoid derivatives, cambodianin G (1) and cambodianin H (2). Their structures were elucidated on the basis of detailed spectroscopic analysis, including 1D and 2D NMR techniques and chemical methods. The two compounds were observed to exhibit antibacterial activities against Staphylococcus aureus, and compound 1 showed cytotoxicities against K562 and SGC-7901 cell lines.