• 제목/요약/키워드: Biological sample

검색결과 938건 처리시간 0.061초

Flame Atomic Absorption Spectrometric Determination of Trace Amounts of Thallium after Solid-Liquid Extraction and Preconcentration with Use of 1,10-Phenanthroline onto Benzophenone

  • Taher, Mohammad Ali
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1177-1180
    • /
    • 2003
  • Thallium is quantitatively retained by 1,10-phenanthroline and tetraphenylborate onto benzophenone in the pH range 0-11 from a large volumes of aqueous solutions of various samples. After filtration, the solid mass consisting of thallium complex and benzophenone is dissolved with 5 mL of dimethylformamide and the metal was determined by flame atomic absorption spectrometric. About 0.4 ㎍ of thallium can be concentrated from 400 mL of aqueous sample, where its concentration is as low as 1.0 ng/mL. Eight replicate determinations of 8.0 ㎍/mL of thallium in final dimethylformamide solution gave a mean absorbance of 0.160 with a relative standard deviation of 1.7%. The sensitivity for 1% absorption was 0.22 ㎍/mL. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of thallium in various alloys and biological samples.

비정상 시변 신호 인식기의 실시간 구현 및 근피로도 측정에의 응용 (Real Time Implementittion of Time Varying Nonstationary Signal Identifier and Its Application to Muscle Fatigue Monitoring)

  • 이진;이영석;김성환
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.317-324
    • /
    • 1995
  • A need exists for the accurate identification of time series models having time varying parameters, as is important in the case of real time identification of nonstationary EMG signal. Thls paper describes real time identification and muscle fatigue monitoring method of nonstationary EMG signal. The method is composed of the efficient identifier which estimates the autoregressive parameters of nonstationary EMG signal model, and its real time implementation by using T805 parallel processing computer. The method is verified through experiment with real EMG signals which are obtained from surface electrode. As a result, the proposed method provides a new approach for real time Implementation of muscle fatigue monitoring and the execution time is 0.894ms/sample for 1024Hz EMG signal.

  • PDF

최대 및 최소 기울기 갱신에 의한 ECG 압축 알고리듬을 이용한 실시간 3채널 전송시스템 구현 (Implementation of Real Time 3 channel Transmission System Using ECG Data Compression Algorithm by Max-Min Slope Update)

  • 조진호;김명남
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.271-278
    • /
    • 1995
  • An ECG data compression algorithM using max-min slope update is proposed and a real time 3 channel ECG transmission system is implemented using the proposed algorithm. In order to effectively compress ECG data, we compare a threshold value with the max-min slope difference (MMSD) which is updated at each sample values. If this MMSD value is smaller than the threshold value, then the data is compressed. Conversely, when the MMSD value is larger than threshold value, the data is transmitted after storing the value and the length between the data which is beyond previous threshold level. As a result, it can accurately compress both the region of QRS, P, and T wave that has fast-changing and the region of the base line that slope is changing slow. Therefore, it Is possible to enhance the compression rate and the percent roms difference. In addition, because of the simplicity, this algorithm is more suitable for real-time implementation.

  • PDF

아동성학대의 실태와 관련변인 -지방대도시 청년기여성의 경험을 중심으로- (A study on the child sexual abuse and related variables -focused on experiences of female adolescents in metropolitan areas-)

  • 유가효
    • 대한가정학회지
    • /
    • 제33권5호
    • /
    • pp.221-239
    • /
    • 1995
  • Using a nonclinical sample of 566 female students, this study examines the frequency and the severity of child sexual abuse in Taegu area. It also analyzes the factors that determine the probability of experiencing both contact and noncontact forms of the abuse. The results show that children from low socio-economic status tend to experience severe types of contact abuse while children from higher socio-economic status ten to experience severe types of contact abuse while children from higher socio-economic status are likely to be exposed to noncontact abuse. The growing place in the childhood also affects the victimization to noncontact and contact abuse differently. The absence of the biological parents significantly contributes to the occurrence of contact abuse, but have no impact on the noncontact abuse. However, the closeness of the family members and frequent communication reduce the rates of both contact and noncontact abuse substantially.

  • PDF

가축분뇨 슬러지의 악취제거 효율이 높은 미생물 개발과 표면반응법을 이용한 발효조건 최적화

  • 김소영;이재용;손석민;이기영;이건순;김홍;채희정
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2003년도 생물공학의 동향(XII)
    • /
    • pp.171-174
    • /
    • 2003
  • Animal excreta is a useful fertilizer, because it has useful nourishments, microelements and three requistes of fertilizer(nitrogen, phosphorus, potassium). But, it has some problems such as generation of bad smell and excess of nitrogen. In this study, a biological tool using microorganisms was investingated. First, 61 species were isolated from soil sample. The enzyme activities of the strains such as protease, cellulase, amylase and lipase were analysed. And from a deodorization test using the isolated strains and finally three strains were selected(NA 2, NA 12, NA 15). The optimal media composition and incubation pH were statistically determined using surface-response method.

  • PDF

Effect of shear on poly(styrene-b-isoprene) copolymer micelles

  • Bang, Joon-A;Lodge, Timothy P.
    • Korea-Australia Rheology Journal
    • /
    • 제19권4호
    • /
    • pp.227-232
    • /
    • 2007
  • The use of various shearing apparatuses to study the phase behavior of poly(styrene-b-isoprene) diblock copolymer micelles is described. A DMTA rheometer was modified so that one can apply oscillatory shear and obtain the scattering pattern along the shear gradient direction. A cone and plate shear cell was designed to access scattering along the shear vorticity direction, and both oscillatory and steady shear can be applied. The most popular way to employ steady shear on relatively low viscosity fluids is to use a Couette cell, because a high shear rate can be readily achieved without disturbing the sample by overflow. In this work, oscillatory shear was used to obtain a single crystal-like scattering pattern, and thereby to examine the mechanism of the thermotropic transition between face-centered cubic (fcc) and body-centered cubic (bcc) lattices. By applying the steady shear, the response of the fcc lattices to various shear rates is discussed.

오염지반 복원공법분석 및 고찰 (The restoration-method of contaminated ground process and investigation)

  • 노시원;윤준영;이영생
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.615-620
    • /
    • 2010
  • In this paper, conventional biological treatment methods to compensate for the shortcomings bio-Ceramic -technology to develop fusion as a preliminary step of the analysis and review process to restore contaminated soil and BTEX (benzene, toluene, ethylbenzene, xylene) contaminated by Soil physical and mechanical properties were analyzed. As a result, pollution levels and other contaminants by supporting the sample tests carried out by mechanical properties testing, and the difference between unpolluted soil were compared.

  • PDF

Applications of Microfluidics in the Agro-Food Sector: A Review

  • Kim, Giyoung;Lim, Jongguk;Mo, Changyeun
    • Journal of Biosystems Engineering
    • /
    • 제41권2호
    • /
    • pp.116-125
    • /
    • 2016
  • Background: Microfluidics is of considerable importance in food and agricultural industries. Microfluidics processes low volumes of fluids in channels with extremely small dimensions of tens of micrometers. It enables the miniaturization of analytical devices and reductions in cost and turnaround times. This allows automation, high-throughput analysis, and processing in food and agricultural applications. Purpose: This review aims to provide information on the applications of microfluidics in the agro-food sector to overcome limitations posed by conventional technologies. Results: Microfluidics contributes to medical diagnosis, biological analysis, drug discovery, chemical synthesis, biotechnology, gene sequencing, and ecology. Recently, the applications of microfluidics in food and agricultural industries have increased. A few examples of these applications include food safety analysis, food processing, and animal production. This study examines the fundamentals of microfluidics including fabrication, control, applications, and future trends of microfluidics in the agro-food sector. Conclusions: Future research efforts should focus on developing a small portable platform with modules for fluid handling, sample preparation, and signal detection electronics.

마이크로 컴퓨터를 이용한 휴대용 부정맥 모니터의 개발(I)-하드웨어 설계를 중심으로- (Development of Portable Arrhythmia Moniter Using Microcomputer(I))

  • 이명호;안재봉
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.169-182
    • /
    • 1986
  • Pulsed ultrasonic Doppler system is a useful diagnostic instrument to measure blood-flow-velocity, velocity profile, and volume-blood-flow. This system is more powerful compare with 2-dimensional B-scan tissue image. A system has been deve- loped and ii being evaluated using TMS 32010 DSP. We use this DSP for the purpose of real-time spectrum analyzer to obtain spectrogram in singlegate pulsed Doppler system and for the serial comb filter to cancel clutter and zero crossing counter to estimate Doppler mean frequency in multigate pulsed Doppler system. The Doppler shift of the backscattered signals is sensed in a phase detector. This Doppler signal corresponds to the mean velocity over a some region in space defined by the ultrasonic beam dimensions, transmitted pulse duration, and transducer ban(iwidth. Multi- gate pulsed Doppler system enable the transcutaneous and simultaneous assessment of the velocities in a number of adjacent sample volumes as a continuous function of time. A multigate pulsed Doppler system processing the information originating from presented.

  • PDF

가시 반사광을 이용한 임상화학 분석장치 개발의 기초연구 (A Study on Clinical Chemistry Analyzer Development by Using the Reflected Visible Light)

  • 유동주;정태화;민홍기;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.144-147
    • /
    • 1992
  • In this paper, we study about reflectance photometer for measuring teflectance changes on reagent strip material after applying of a liguid sample. To obtain more accurate reflectance parameter, the strip loader and cassette is designed. The system is designed to work with IBM personal computer. As the experimental results, reflectance level measured of korean standard color paper and shows a exponentially proportion to brightness of paper. A diagnostic strip for total protein is applied to our system and shows a good correlation in a physically protein concentration range.(up to 500 mg/dl).

  • PDF