• Title/Summary/Keyword: Bio-Data

Search Result 2,127, Processing Time 0.024 seconds

Visual Cell : Image Analysis and Visual Retrieval System for Biology Cell Image Bigdata (Visual Cell : 바이오세포 이미지 빅데이터를 위한 이미지 분석 및 시각적 검색 시스템)

  • Park, Beomjun;Jo, Sunhwa;Lee, Suan;Shin, Jiwoon;Yoo, Hyuk Sang;Kim, Jinho
    • The Journal of Bigdata
    • /
    • v.4 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • The extracellular matrix, which provides the structural and biochemical support of surrounding cells, is a cell physiological modulator that controls cell division and differentiation. In the bio sector, the company produces Scapold, a three-dimensional support for tissue engineering, and cultivates stem cells in the produced Scapold to be transplanted into animals to assess tissue regeneration. This depends on components such as collagen in the tissue. Therefore, it is very important to identify the inclusion rate and distribution of components in the tissue, and the data are obtained by analyzing the color of the dyed tissue image. The process from image collection to analysis is costly, and the data collected and analyzed are managed in different formats by different research institutions. Therefore, data integration management and analysis results search are not being performed. In this paper, we establish a database that can manage relevant bigdata in an integrated manner, and propose a bio-image integrated management and retrieval system that can be searched based on color, an important analytical measure in this field of study.

  • PDF

Design of The Patient Monitoring System based on Wearable Device for Multi-biosignal Measurement (다중 생체신호 측정 웨어러블 디바이스 기반 환자 모니터링 시스템 설계)

  • Lee, Minhye;Chung, Gisoo;Jeong, Dongmyong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.103-109
    • /
    • 2017
  • In order to apply the patient monitoring system to the hospital field, it is necessary to be able to measure and analysis data the major bio-signals that are basically covered by the existing patient monitoring system. We have implemented a wearable device and the patient monitoring system for measuring ECG and oxygen saturation. The implemented system transmits the measured bio-signal to the server on the nursing station via Bluetooth. It is represented by graph waveforms and numerical values that can be checked by the medical staff in the patient monitoring system. The validity of this system is verified by comparing the data collected through the designed system with the data obtained from the conventional equipment.

A Position based Kinematic Method for the Analysis of Human Gait

  • Choi Ahn Ryul;Rim Yong Hoon;Kim Youn Soo;Mun Joung Hwan
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.10
    • /
    • pp.1919-1931
    • /
    • 2005
  • Human joint motion can be kinematically described in three planes, typically the frontal, sagittal, and transverse, and related to experimentally measured data. The selection of reference systems is a prerequisite for accurate kinematic analysis and resulting development of the equations of motion. Moreover, the development of analysis techniques for the minimization of errors, due to skin movement or body deformation, during experiments involving human locomotion is a critically important step, without which accurate results in this type of experiment are an impossibility. The traditional kinematic analysis method is the Angular-based method (ABM), which utilizes the Euler angle or the Bryant angle. However, this analysis method tends to increase cumulative errors due to skin movement. Therefore, the objective of this study was to propose a new kinematic analysis method, Position-based method (PBM), which directly applies position displacement data to represent locomotion. The PBM presented here was designed to minimize cumulative errors via considerations of angle changes and translational motion between markers occurring due to skin movements. In order to verify the efficacy and accuracy of the developed PBM, the mean value of joint dislocation at the knee during one gait cycle and the pattern of three dimensional translation motion of the tibiofemoral joint at the knee, in both flexion and extension, were accessed via ABM and via new method, PBM, with a Local Reference system (LRS) and Segmental Reference system (SRS), and then the data were compared between the two techniques. Our results indicate that the proposed PBM resulted in improved accuracy in terms of motion analysis, as compared to ABM, with the LRS and SRS.

Development of a Real-Time Measurement System for Horizontal Soil Strength

  • Cho, Yongjin;Lee, Dong Hoon;Park, Wonyeop;Lee, Kyou Seung
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.165-177
    • /
    • 2015
  • Purpose: Accurate monitoring of soil strength is a key technology applicable to various precision agricultural practices. Soil strength has been traditionally measured using a cone penetrometer, which is time-consuming and expensive, making it difficult to obtain the spatial data required for precision agriculture. To improve the current, inefficient method of measuring soil strength, our objective was to develop and evaluate an in-situ system that could measure horizontal soil strength in real-time, while moving across a soil bin. Methods: Multiple cone-shape penetrometers were horizontally assembled at the front of a vertical plow blade at intervals of 5 cm. Each penetrometer was directly connected to a load cell, which measured loads of 0-2.54 kN. In order to process the digital signals from every individual transducer concurrently, a microcontroller was embedded into the measurement system. Wireless data communication was used between a data storage device and this real-time horizontal soil strength (RHSS) measurement system travelling at 0.5 m/s through an indoor experimental soil bin. The horizontal soil strength index (HSSI) measured by the developed system was compared with the cone index (CI) measured by a traditional cone penetrometer. Results: The coefficient of determination between the CI and the HSSI at depths of 5 cm and 10 cm ($r^2=0.67$ and 0.88, respectively) were relatively less than those measured below 20 cm ($r^2{\geq}0.93$). Additionally, the measured HSSIs were typically greater than the CIs for a given numbers of compactor operations. For an all-depth regression, the coefficient of determination was 0.94, with a RMSE of 0.23. Conclusions: A HSSI measurement system was evaluated in comparison with the conventional soil strength measurement system, CI. Further study is needed, in the form of field tests, on this real-time measurement and control system, which would be applied to precision agriculture.

A STUDY ON THE POSTOPERATIVE STABILITY OF LEFORT I OSTEOTOMY IN THE TWO-JAW SURGERY OF THE SKELETAL CLASS III MALOCCLUSION PATIENTS (골격성 제 III급 부정교합 환자의 상하악 동시이동술시 LeFort I 상악골절단술의 술후 안정성에 관한 연구)

  • Im, Yang-Hee;Ko, Seung-O;Shin, Hyo-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.397-403
    • /
    • 2001
  • Purpose: The purpose of this study was to evaluate the postoperative stability of LeFort I osteotomy in two-jaw surgery of skeletal class III malocclusion and to help the establishment of treatment planning in patients with a skeletal class III malocclusion in the future. Materials and Methods: The lateral cephalograms of 14 patients who had been underwent two-jaw surgery via one-piece LeFort I osteotomy were traced and the landmarks were identified. Repeated tracings and construction of reference planes were done. Comparisons were made from the immediate postoperative to late postoperative results of each landmarks on the horizontal and vertical directions. Conclusions: 1. The horizontal changes of landmark ANS, point A, PNS and Mx6Rt between immediate postoperative to late postoperative data were statistically insignificant(p>0.05). 2. The vertical changes of landmark ANS, point A, PNS, Mx6Cr and Mx6Rt between immediate postoperative to late postoperative data were statistically insignificant(p>0.05). 3. The horizontal change of landmark Mx6Cr between immediate postoperative to late postoperative data was statistically significant(p<0.05). 4. Results showed that it was stable that one-piece LeFort I osteotomy in two-jaw surgery of skeletal class III malocclusion.

  • PDF

Assessing Vulnerability to Agricultural Drought of Pumping Stations for Preparing Climate Change (기후변화 대응을 위한 양수장의 농업가뭄 취약성 실태 평가)

  • Jang, Min-Won;Kim, Soo-Jin;Bae, Seung-Jong;Yoo, Seunghwan;Jung, Kyunghun;Hwang, Syewoon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.31-40
    • /
    • 2019
  • In order to implement practical alternatives to proactively cope with the agricultural drought, the potential vulnerability of irrigation pumping stations to agricultural drought was quantitatively evaluated. Data for the 124 pumping stations which are correlatable to the three proxy variables, i.e. exposure, sensitivity, and adaptive capacity was collected by the Korea Rural Community Corporation, and then standardized considering distribution of each data set. Finally, the vulnerability index was calculated by multiplying the weights determined by the expert survey. The results showed that the vulnerability index ranged from 0.709 to 0.331 and the most vulnerable pumping stations such as Judam, Wongoo and Jinahn were mostly located in Gyeongbuk province likely because of the climatological characteristics with high temperature and low rainfall around this area. In addition, it was found that the adaptive capacity was a dominant factor comparing to exposure or sensitivity proxy variables in contributing to the vulnerability. It is therefore recommended that more practical alternatives should be employed to effectively reduce the vulnerability of an individual pumping station to agricultural drought. Furthermore, the corresponding data related to adaptive capacity should be systematically organized and managed at a field level to design reliable adaptation strategies.

Development of Integrated Retrieval System of the Biology Sequence Database Using Web Service (웹 서비스를 이용한 바이오 서열 정보 데이터베이스 및 통합 검색 시스템 개발)

  • Lee, Su-Jung;Yong, Hwan-Seung
    • The KIPS Transactions:PartD
    • /
    • v.11D no.4
    • /
    • pp.755-764
    • /
    • 2004
  • Recently, the rapid development of biotechnology brings the explosion of biological data and biological data host. Moreover, these data are highly distributed and heterogeneous, reflecting the distribution and heterogeneity of the Molecular Biology research community. As a consequence, the integration and interoperability of molecular biology databases are issue of considerable importance. But, up to now, most of the integrated systems such as link based system, data warehouse based system have many problems which are keeping the data up to date when the schema and data of the data source are changed. For this reason, the integrated system using web service technology that allow biological data to be fully exploited have been proposed. In this paper, we built the integrated system if the bio sequence information bated on the web service technology. The developed system allows users to get data with many format such as BSML, GenBank, Fasta to traverse disparate data resources. Also, it has better retrieval performance because the retrieval modules of the external database proceed in parallel.

An Emergency Management Architecture Using Personalized Emergency Policy for Smart Healthcare (스마트 헬스케어를 위한 사용자 맞춤형 응급 정책을 활용한 응급 관리 구조)

  • Chun, Seung-Man;Choi, Joo-Yeon;Park, Jong-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.3-11
    • /
    • 2013
  • In smart healthcare service, the accurate and prompt emergency detection and notification are very critical to patients' lives. Since these detection and notification of emergency situation are usually performed by the medical staffs, it is difficult to simultaneously support many patients in real-time. This article presents a methodology for emergency bio-data transmission for smart healthcare using personalized emergency policy. It consists of three steps: In step 1, the bio-data is collected by wireless body area network. In step 2, the decision on emergency is made using personalized emergency policy. In step 3, the emergency message including the health condition information is converted between IEEE 11073 PHD message and HL7 CDA. By doing this, the emergency status of the individual bio-data collected from wireless body area network is detected automatically using personalized emergency policy. When the emergency is detected, the quick emergency rescue service can be provided to the patient by delivering to the emergency notification and the emergency bio-data. We have verified the service and functions of the proposed system architecture by realizing it.

Analysis of Applicability by Filter Technique for Water Level Correction of Agricultural Canal (농업용 수로부의 수위 보정을 위한 필터기법별 적용성 분석)

  • Joo, Donghyuk;Na, Ra;Kim, Ha-Young;Choi, Gyu-hoon;Yun, Hyung Chang;Park, Sang-Bin;Yoo, Seung-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.5
    • /
    • pp.51-68
    • /
    • 2023
  • Due to the recent integrated water management policy, it is important to identify a reliable supply amount for establishing an agricultural water supply plan. In order to identify the amount of agricultural water supply, it is essential to calculate the discharge by measuring the water level and flow velocity of reservoirs and canal agricultural water, and quality control to ensure reliability must be preceded. Unlike agricultural reservoirs, canal agricultural water are more sensitive to the surrounding environment and reservoir irrigation methods (continuous, intermittent irrigation, etc.), making it difficult to estimate general water level patterns and at the same time a lot of erroneous data. The Korea Rural Community Corporation is applying a filter technique as a quality control method capable of processing large quantities and real-time processing of canal agricultural water level data, and applicability evaluation is needed. In this study, the types of errors generated by the automatic water level measurement system were first determined. In addition, by using the manual quality control data, a technique with high applicability is derived by comparing and analyzing data calibrated with Gaussian, Savitzky-Golay, Hampel, and Median filter techniques, RMSE, and NSE, and the optimal parameters of the technique range was derived. As a result, the applicability of the Median filter was evaluated the highest, and the optimal parameters were derived in the range of 120min to 240min. Through the results of this study, it is judged that it can be used for quantitative evaluation to establish an agricultural water supply plan.

The Characteristics Study of Vehicle Evaporative Emission and Performance according to the Bio-Fuel Application (바이오 연료 적용에 따른 차량 증발가스 및 성능특성 연구)

  • Noh, Kyeong-Ha;Lee, Min-Ho;Kim, Ki-Ho;Kim, Sin;Park, Cheon-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.874-882
    • /
    • 2017
  • As the interest on the air-pollution is gradually rising up at home and abroad, automotiv e and fuel researchers have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative after-treatment systems, using clean (eco-friendly alternative) fuels and fuel quality improvement. This research has brought forward three main issues : evaporative, performance, air pollution. In addition, researcher studied the environment problems of the bio-ethanol, bio-butanol, bio-ETBE (Ethyl Tertiary Butyl Ether), MTBE (Methyl Tert iary Butyl Ether) fuel contained in the fuel as octane number improver. The researchers have many dat a about the health effects of ingestion of octane number improver. However, the data support the con clusion that octane number improver is a potential human carcinogen at high doses. Based on the bio-fuel and octane number improver types (bio-ethanol, bio-butanol, bio-ETBE, MTBE), this paper dis cussed the influence of gasoline fuel properties on the evaporative emission characteristics. Also, this p aper assessed the acceleration and power performance of gasoline vehicle for the bio-fuel property. As a result of the experiment, it was found that all the test fuels meet the domestic exhaust gas standards, and as a result of measurement of the vapor pressure of the test fuels, the bio - ethanol : 15 kPa and the biobutanol : 1.6 kPa. thus when manufacturing E3 fuel, Increasing the biobutanol content reduces evaporation gas and vapor pressure. In addition, Similar accelerating and powering performance was shown for the type of biofuel and when bio-butanol and bio-ethanol were compared accelerated perf ormance was improved by about 3.9% and vehicle power by 0.8%.