• Title/Summary/Keyword: Bias system development

Search Result 169, Processing Time 0.028 seconds

Characteristics on Boundary Layer and Formation Mechanism of c-BN Thin Films During Electron Assisted Hot Filament CVD Process (EAHFCVD법에 의한 c-BN 박막형성기구와 계면층의 특성에 관하여)

  • Choi, Yong;Choe, Jean-I.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.89-93
    • /
    • 2012
  • c-BN films were deposited on SKH-51 steels by electron assisted hot filament CVD method and microstructure development was studied processing parameters such as bias voltage, temperature, etching and phase transformation at boundary layer between BN compound and steel to develop a high performance wear resistance tools. A negative bias voltage higher than 200V at substrate temperature of $800^{\circ}C$ and gas pressure of 20 torr in B2H6-NH3-H2 gas system was one of optimum conditions to produce c-BN films on the SKH-51 steels. Thin layer of hexagonal boron nitride phase was observed at the interface between c-BN layer and substrate.

Development of Automatic Analysis System for Water Repellency of Packaging Paper -Automatic Measurement of Water Repellency Based on KS M 7057- (포장지의 발수도 자동 해석 시스템 개발 -KS M 7057에 근거한 발수도 자동 측정-)

  • 김철환;최경민;강진기;박종열
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.35 no.1
    • /
    • pp.7-12
    • /
    • 2003
  • The test results for water repellency of paper and paperboard according to KS M 7057 can readily be influenced by an operator's bias. In order to discard such bias, the automatic analysis program of water repellency was developed based on different shape features of a liquid trace formed on a specimen. That is, the shape of a liquid track flowing down on the specimen with an angle of $45^{\circ}$ was evaluated according to width variation between head and tail of the trace($S_{Hr}$), uniformity of a liquid flow($S_{d}$), length of long traces($L_{SHr}$), eccentricity of liquid traces($E_{i}$), and then was recognized as a specific degree of water repellency. Finally, the automatic analysis system of water repellency based upon KS M 7057 made it possible to readily measure water resistance of paper and paperboards classified into R0 to R10.

Movie Recommendation System based on Latent Factor Model (잠재요인 모델 기반 영화 추천 시스템)

  • Ma, Chen;Kim, Kang-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.125-134
    • /
    • 2021
  • With the rapid development of the film industry, the number of films is significantly increasing and movie recommendation system can help user to predict the preferences of users based on their past behavior or feedback. This paper proposes a movie recommendation system based on the latent factor model with the adjustment of mean and bias in rating. Singular value decomposition is used to decompose the rating matrix and stochastic gradient descent is used to optimize the parameters for least-square loss function. And root mean square error is used to evaluate the performance of the proposed system. We implement the proposed system with Surprise package. The simulation results shows that root mean square error is 0.671 and the proposed system has good performance compared to other papers.

A Study on Implementation of Automatic Evaluation System for Static Performance of 6 DOF MEMS Inertial Sensor (6자유도 MEMS 관성센서 정적성능 자동 평가 시스템 구현에 관한 연구)

  • Ji Won Park;Hussamud Din;Byeung Leul Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.62-66
    • /
    • 2023
  • With the advancement in technology and rapid increase in the demand for microelectromechanical systems (MEMS) based inertial measurement units (IMUs), high-volume production and test system remain a major challenge for the MEMS industry. To compete with the challenging market of Industry 4.0, here we developed an automatic test system to evaluate the performance of the ovenized IMU sensors as well as analyze the data. The automatic test system was developed by interfacing a commercial MEMS IMU (BMI 088) using LabVIEW. The BMI 088 was tested experimentally for long-term bias stability, ON/OFF bias repeatability, and root mean square (rms) noise. Furthermore, the data was analyzed through the developed test system. The results show that the automatic test system has improved the test time and reduced human effort. The developed automatic test system is a significant approach to MEMS research and development (R&D) to increase and improve the mass production of IMUs.

  • PDF

Stripping Method of Ring Laser Gyroscope Based on Measurement Model of Dither Motion (디더 운동 측정치 모델 기반 링레이저 자이로 스트리핑 방법)

  • Kim, Cheon-Joong;Shim, Kyu-Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.531-536
    • /
    • 2014
  • There are trapping and stripping methods as the technique to remove the dither motion from RLG(Ring Laser Gyro) output. V/F converter output of angular sensor to measure the dither motion is used in stripping method. But bias and scale factor error is always included in V/F converter output and is a critical limiting factor for the wide application of stripping method to RLG. Therefore there have been many researches to solve this problem. The method to accurately estimate the bias and scale factor error of V/F converter using measurements of the angular sensor acquired at data sampling rate of INS is presented in this paper. To this end, stripping technique based on model of dither motion is newly applied.

Effect of Proton Irradiation on the Magnetic Properties of Antiferromagnet/ferromagnet Structures

  • Kim, Dong-Jun;Park, Jin-Seok;Ryu, Ho Jin;Jeong, Jong-Ryul;Chung, Chang-Kyu;Park, Byong-Guk
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.159-163
    • /
    • 2016
  • Antiferromagnet (AFM)/ferromagnet (FM) bilayer structures are widely used in the magnetic devices of sensor and memory applications, as AFM materials can induce unidirectional anisotropy of the FM material via exchange coupling. The strength of the exchange coupling is known to be sensitive to quality of the interface of the AFM/FM bilayers. In this study, we utilize proton irradiation to modify the interface structures and investigate its effect on the magnetic properties of AFM/FM structures, including the exchange bias and magnetic thermoelectric effect. The magnetic properties of IrMn/CoFeB structures with various IrMn thicknesses are characterized after they are exposed to a proton beam of 3 MeV and $1{\sim}5{\times}10^{14}ions/cm^2$. We observe that the magnetic moment is gradually reduced as the amount of the dose is increased. On the other hand, the exchange bias field and thermoelectric voltage are not significantly affected by proton irradiation. This indicates that proton irradiation has more of an influence on the bulk property of the FM CoFeB layer and less of an effect on the IrMn/CoFeB interface.

The Development of a Signal Validation Scheme for the Redundant Multi-Channel Measurement System (다중채널 측정계통의 신호검증기법 개발)

  • Hwang, In-Koo;Na, Nan-Ju;Kwon, Kee-Choon;Ham, Chang-Shik
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.367-373
    • /
    • 1994
  • It is necessary to adopt a simple signal validation for avoiding the complexity of algorithm and verification in the design process of the instrumentation and control system in nuclear plants. This paper suggests a signal validation method developed on the basis of consistency checking for the multi-channel measurement system without any analytic process model. It includes a simplified algorithm for estimating the fixed bias error of each channel and a weighted averaging method. The weighting factor of each channel is updated according to its calculated bias error. The developed method has been tested to verify its performance through several input scenarios.

  • PDF

A Study on the G-Sensitivity Error of MEMS Vibratory Gyroscopes (진동형 MEMS 자이로스코프 G-민감도 오차에 관한 연구)

  • Park, Byung-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.8
    • /
    • pp.1075-1079
    • /
    • 2014
  • In this paper, we describe the analysis and the compensation method of the g-sensitivity error for MEMS vibratory gyroscopes. Usually, the g-sensitivity error has been ignored in the commercial MEMS gyroscope, but it deserves our attention to apply for the missile application as a tactical grade performance. Thus, it is necessary to compensate for the g-sensitivity error to reach a tactical grade performance. Generally, the g-sensitivity error seems intuitively to be a gyroscope bias error proportional to the linear acceleration. However, we assert that the g-sensitivity error mainly causes not a bias error but a scale-factor error. And we verify that the g-sensitivity scale-factor error occurs due to the non-linearity of parallel plate electrodes. Therefore, we propose the compensation method to remove the g-sensitivity scale-factor error. The experimental result showed that a proposed compensation method improved successfully the performance of the MEMS vibratory gyroscope.

Development of the CuN/Cu/CuN type Electrode Material for the PDP (PDP용 CuN/Cu/CuN 전극재료의 개발에 관한 연구)

  • 성열문;정신수;류재하;김재성;조정수;박정후
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.55-58
    • /
    • 1996
  • A new type CuN/Cu/CuN thin film electrode material with high adhesion to glass was developed by the dc reactive planar magnetron sputtering system for the PDP(Plasma Display Panel). The adhesive force of the CuxN thin film was in the range of 20∼40(N) under the conditions of the N$_2$ partial pressure of 15%, discharge current of 70mA, discharge voltage of 450v and substrate bias voltage of -100V. The adhesive force was depended on the N$_2$ partial Pressure, discharge current and substrate bias voltage.

  • PDF

Fiber Optic Gyroscope using IOC (IOC를 사용한 광파이버 자이로)

  • Kim, In-Soo S.;Kim, Yo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1843-1845
    • /
    • 1998
  • Gyroscope is a very important core sensor as a rotation sensor in inertial space, in inertial guidance and navigation system on aeronautics. Plane, vessel and so on for civilian and millitary applications. Research and development of fiber optic gyroscope began in 1976 and focused on improving the gyroscope's sensitivity to rotation. bias performance and reducing noise. We have developed a Interferometric Fiber Optic' Gyroscope using a integrated-optic-circuit (IOC), which is operating with closed-loop electronic circuit. This paper describes the scheme of optical part and electronic part and also test results of this fiber optic gyroscope using a integrated-optic-circuit (IOC). The performance have been achieved as long-term bias drift of $1.73^{\circ}/h$.

  • PDF