• 제목/요약/키워드: Bi-directional pump

검색결과 18건 처리시간 0.03초

능동형 체크 밸브를 이용한 고출력 압전 마이크로펌프 (High-output Piezoelectric Micropump Using Active Check Valves)

  • 박중호;요시다 카즈히로;요코타 신이치;함영복;윤소남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1864-1869
    • /
    • 2003
  • A novel piezoelectric micropump using active check valves in place of conventional passive check valves in inlet and outlet has been proposed and investigated. It actively controls open/close motion of check valves using piezoelectric actuator for expansion/contraction of pump chamber. In this paper, bi-directional flow characteristics and load characteristics are experimentally investigated using an adequate timing control for valve closing motion with a prototype micropump fabricated with the effective size of $17{\times}8{\times}11mm^{3}$. From the experimental results, it is ascertained that optimal values of phase shift against voltage to drive pump chamber for realization of a miniaturized but powerful micropump, are $15^{\circ}$ in inlet check valve and $195^{\circ}$ in outlet. Based on the obtained results, a sheet-type active shuttle valve that has a unified valve-body for inlet and outlet check valves is proposed. A micropump with the effective size of $10{\times}10{\times}10mm^{3}$ is fabricated and basic characteristics are experimentally investigated.

  • PDF

양방향 압전-유압 하이브리드 구동장치의 성능 시험 (Performance Evaluation of a Bidirectional Piezoelectric Hybrid Actuator)

  • 김소룡;하넉산;구남서;배병운;김태흔;고한서;이창섭
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.213-219
    • /
    • 2015
  • Piezoelectric-based hydraulic actuator is a hybrid device consisting of a hydraulic pump driven by piezoelectric stacks that is coupled to a conventional hydraulic cylinder via a set of fast-acting valves. Nowadays, such hybrid actuators are being researched and developed actively in many developed countries by requirement of high performance and compact flight system. In this research, a piezoelectric hybrid actuator has been designed and tested. To achieve bi-directional capabilities in the actuator, solenoid valves were used to control the direction of output fluid. The experimental testing of the actuator in uni-directional and bi-directional modes was performed to examine performance issues related to the solenoid valves. The results showed that the bi-directional performance was slightly lower than uni-directional performance due to air bubble developed in the valve system. A new design to solve the vacuum problem has been proposed to improve the performance of the hybrid actuator.

양방향 축류펌프의 전산유동 해석 (Numerical Analysis of Flow through Bi-Directional Axial Pump)

  • 강상모;정원혁
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.212-212
    • /
    • 2011
  • 이 논문은 선박의 자세 안정성 유지를 위한 anti-heeling system 용 양방향 펌프에 대하여 연구하였다. 기존 양방향펌프의 기술은 모터 외장용 수직방식의 양방향 펌프를 사용해왔다. 현재는 모터내장용 양방향 펌프가 개발되고 있다. 수직방식의 양방향 펌프와 모터 내장용 양방향 펌프를 유동해석을 통하여 성능을 비교하고 앞으로 개선되어야 할 문제점에 대하여 연구하였다.

  • PDF

가변선단재하판을 이용한 양방향말뚝재하시험의 모형실험 (Model Test of O-Cell Pile Load Test with Variable End Plate)

  • 주용선;김낙경;김성규;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.476-481
    • /
    • 2009
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.

  • PDF

전도 수문용 폐회로형 유압장치의 작동 특성에 관한 연구 (Study for the Operational Characteristics of Closed Circuit Hydraulic System of Turnover-Type Sluice Gate)

  • 이성래
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.897-902
    • /
    • 2007
  • The turnover-type sluice gate is typically actuated by the open circuit hydrauic system since the single-rod cylinder is used rather than the double-rod cylinder. However, here the closed circuit hydrauic system is applied for the operation of turnover-type sluice gate for the purpose of convenient operation. The closed circuit hydraulic system of turnover-type sluice gate is composed of a bi-directional pump, single-rod cylinders, pilot operated check valves, check valves and a counter balance valve. The usefulness of the closed circuit hydraulic system is verified for the several operational conditions by the computer simulations.

  • PDF

Annual Energy Production Maximization for Tidal Power Plants with Evolutionary Algorithms

  • Kontoleontos, Evgenia;Weissenberger, Simon
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.264-273
    • /
    • 2017
  • In order to be able to predict the maximum Annual Energy Production (AEP) for tidal power plants, an AEP optimization tool based on Evolutionary Algorithms was developed by ANDRITZ HYDRO. This tool can simulate all operating modes of the units (bi-directional turbine, pump and sluicing mode) and provide the optimal plant operation that maximizes the AEP to the control system. For the Swansea Bay Tidal Power Plant, the AEP optimization evaluated all different hydraulic and operating concepts and defined the optimal concept that led to a significant AEP increase. A comparison between the optimal plant operation provided by the AEP optimization and the full load operating strategy is presented in the paper, highlighting the advantage of the method in providing the maximum AEP.

펌핑 구조에 따른 1 kW급 협대역 편광 유지 광섬유 레이저의 출력 특성 연구 (A Study of the Output Characteristics of a 1-kW-class Narrow-bandwidth PM Fiber Laser Depending on Its Pumping Structure)

  • 김태형;정성묵;김기혁;이성헌;양환석
    • 한국광학회지
    • /
    • 제32권4호
    • /
    • pp.187-194
    • /
    • 2021
  • 본 논문에서는 주 증폭기가 양방향 펌핑 방식인 MOPA (master oscillator power amplifier) 협대역 고출력 광섬유 레이저를 제작하였으며, 제작된 레이저의 출력 특성을 연구하였다. 이터븀이 도핑된 코어 25 ㎛, 클래드 400 ㎛ 편광 유지 광섬유를 사용하여 주 증폭부를 제작하였으며, 신호 광원은 PRBS (pseudo-random binary sequence) 신호에 의해 위상 변조된 3 GHz, 10 GHz의 선폭을 갖는 광원을 사용하였다. 3 GHz의 선폭을 가진 신호 광원을 이용하여 순방향과 역방향 펌프 비율을 조절하며 SBS (stimulated Brillouin scattering) 특성을 분석하였다. 10 GHz의 선폭을 가진 신호 광원을 이용하여 주 증폭기의 펌핑 비율에 따른 TMI 특성을 분석하였다. 순방향 및 역방향 펌프 비율을 1.6:1로 입사시켰을 때 주 증폭기의 출력을 1 kW까지 증폭하였으며, 기울기 효율과 빔 품질(M2)은 각각 80%, 1.36으로 측정되었다.

Bi-directional energy transfer process in Er3+-Tm3+-codoped fluorozirconate glasses

  • Cho, Woon-Jo;Kim, Myong-Wook;Kim, Snag-Hyuck;Jo, Jae-Cheol;Choi, Sang-Sam
    • Journal of the Optical Society of Korea
    • /
    • 제1권1호
    • /
    • pp.5-9
    • /
    • 1997
  • Energy transfer direction in $Er^{3+}-Tm^{3+}$-codoped fluorozirconate glasses has been studied. For $Er^{3+}-Tm^{3+}$-codoped glasses, the dependence of the green emission intensity on the pump power (Pex) of 800 nm has ranged from (Pex)$^2$ to (Pex)$^3$. From this multistep absorption, a 1.48 $\mu m$ emission from the $^3F_4{\rightarrow}^3H_4$ transition on Tm$^{3+}$ ion has been found to transfer into $^4I_{13/2}$, $^4I_{9/2}$ and $^4S_{3/2}$ on $Er^{3+}$ ion. In case of the 1.06 $\mu m$ pumping, the emissin ratio of $^3H_4$ level in $Tm^{3+}$ to $^4I_{13/2}$ in $Er^{3+}$ showed that the amount of the energy transfer from $Tm^{3+}$ into $Er^{3+}$ increased with the increasing concentration of $Tm^{3+}$ ion. Our two kinds of pumping scheme suggest that the direction of dominant energy transfer between $Er^{3+}$ and $Tm^{3+}$ should be dependent on whether the $^3F_4$ level resonates in $Tm^{3+}$ the level or not.