• 제목/요약/키워드: Beam current

검색결과 1,312건 처리시간 0.032초

Behaviour and design of high-strength steel beam-to-column joints

  • Li, Dongxu;Uy, Brian;Wang, Jia
    • Steel and Composite Structures
    • /
    • 제31권3호
    • /
    • pp.303-317
    • /
    • 2019
  • This paper presents a finite element model for predicting the behaviour of high-strength steel bolted beam-to-column joints under monotonic loading. The developed numerical model considers the effects of material nonlinearities and geometric nonlinearities. The accuracy of the developed model is examined by comparing the predicted results with independent experimental results. It is demonstrated that the proposed model accurately predicts the ultimate flexural resistances and moment-rotation curves for high-strength steel bolted beam-to-column joints. Mechanical performance of three joint configurations with various design details is examined. A parametric study is carried out to investigate the effects of key design parameters on the behaviour of bolted beam-to-column joints with double-extended endplates. The plastic flexural capacities of the beam-to-column joints from the experimental programme and numerical analysis are compared with the current codes of practice. It is found that the initial stiffness and plastic flexural resistance of the high-strength steel beam-to-column joints are overestimated. Proper modifications need to be conducted to ensure the current analytical method can be safely used for the bolted beam-to-column joints with high-performance materials.

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권1호
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

Influence of Image Sticking on Electra-Optical Characteristics in Alternating-Current Plasma Display Panels

  • Choi, J.H.;Jung, Y.;Jung, K.B.;Kim, S.B.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.760-763
    • /
    • 2003
  • We have investigated the electro-optical characteristics of image sticking in AC PDP. Although Image sticking is one of major factors to determine display quality in AC PDP, so far, it has not being reported why it is occurred and how we can prevent it. In this experiment, we have analyzed the effect of MgO protective layer and phosphor on the image sticking and we have measured the difference of firing voltage, brightness and discharge current between sticking image and normal image in AC PDP. As a result, Phosphor degradation is a more major factor than MgO protective layer and the firing voltage of gas discharge in sticking image is higher than that of normal discharge.

  • PDF

저에너지 대면적 전자빔 발생장치의 이론적 해석 및 설계에 관한 연구 (Theoreticel Analysis and Design of the Low-Energy Large-Aperture Electron Beam Generator)

  • 우성훈;이광식
    • 조명전기설비학회논문지
    • /
    • 제13권3호
    • /
    • pp.40-47
    • /
    • 1999
  • 본 연구에서는 개발하고자 하는 저에너지 대면적 전자빔 발생장치는 원리로서 발생원인 글로우 발전에 의한 플라즈마로부터 이온을 음극으로 가속, 충돌하게 하여 그때 발생하는 2차전자를 전자빔원으로 하여 전자를 가속·제어하는데 바탕을 두고 있으며, 본 연구에서는 이러한 원리를 기본으로 이론적 해석을 통한 고효율의 저에너지 대면적 전자빔 발생장치개발의 설계 및 제작에 대해서 연구하였으며, 또한 빔 에너지의 안전성과 방전조건을 고려한 최적의 방전 파라메타를 설정하여 대면적의 균일한 빔 인출을 가능케 하였다.

  • PDF

Faraday cup array 개발을 위한 Particle Beam Mass Spectrometer 시스템 내에서의 입자 확산 연구 (A Study on Particle Diffusion to Develop Faraday Cup Array of Particle Beam Mass Spectrometer System)

  • 문지훈;신용현;김태성;강상우
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.29-35
    • /
    • 2012
  • The Faraday cup electrode of different size has been developed and evaluated to investigate the diffusion effect of particles by Brownian motion in a particle beam mass spectrometer(PBMS). Particles which focused and accelerated by aerodynamic lens are charged to saturation in an electron beam, and then deflected electrostatically into a Faraday cup detector for measurement of the particle current. The concentration of particles is converted from currents detected by Faraday cup. Measurements of particle current as a function of deflection voltage are combined with measured relationships between particle velocity and diameter, charge and diameter, and mass and diameter, to determine the particle size distribution. The particle currents were measured using 5, 10, 20, 40 mm sized Faraday cup that can be move to one direction by motion shaft. The current difference for each sizes as a function of position was compared to figure out diffusion effect during transport. Polystyrene latex(PSL) 100, 200 nm sized standard particles were used for evaluation. The measurement using 5 mm sized Faraday cup has the highest resolution in a diffusion distance and the smaller particles had widely diffused.

포항방사광가속기 킼커 대출력 펄스전원장치 운전특성 (OPERATING CHARACTERISTICS OF THE PLS INJECTION KICKER MODULATOR)

  • 남상훈;정성훈;고인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1800-1802
    • /
    • 1998
  • The Pohang Light Source (PLS) is a third generation 2 GeV synchrotron machine. An injection kicker modulator is positioned in the PLS storage ring tunnel. The kicker modulator is driving four kicker magnets simultaneously. The kicker magnets produce magnetic field to deflect the stored beam orbit in the storage ring closer to the injected beam from the PLS beam transfer line. The injected beam then falls into the storage ring beam dynamic aperture. The current kicker modulator was upgraded and installed on August 1995. Since then, the kicker modulator has shown very reliable and stable performance. The kicker modulator specifications are ${\sim}6.0{\mu}s$ full width, ${\sim}24$ kA peak current, and 10 Hz repetition rate. Output current waveform is a half sinusoid. Two thyratron switches(EEV CX-1536AX) are used in the kicker modulator. Total accumulated thyratron heater run hour is about 15,000 hours as of May 1998. Measurement result of spatial magnetic field distribution in the kicker magnet shows good uniformity.

  • PDF

생산성 향상을 위한 멀티빔 리소그라피 (Multiple Electron Beam Lithography for High Throughput)

  • 최상국;이천희
    • 한국광학회지
    • /
    • 제16권3호
    • /
    • pp.235-238
    • /
    • 2005
  • 생산성 향상을 위하여 정렬된 마이크로칼럼을 이용하여 멀티-전자빔 리소그라피 장치를 개발하였다. 마이크로칼럼은 매우 작은 크기를 가지고 있어 병렬구조로 정렬하여 작동시킬 수 있다. Single Column Module(SCM) 구조의 멀티 전자빔 리소그라피 시스템과 전자칼럼을 제작하여 250 eV에서 300 eV 에너지 범위에서의 저에너지 마이크로칼럼 리소그라피를 성공적으로 수행하였다. 전자방출원에서 방출되는 전자빔의 총 전류가 $0.5\;{\mu}A$일 때, 샘플에서의 전류는 >1 nA으로 측정되었으며 리소그라피 패텅닝에서 사용된 working distance은 $\~1\;mm$였다.

Initial Dosimetry of a Prototype Ultra-High Dose Rate Electron-Beam Irradiator for FLASH RT Preclinical Studies

  • Hyun Kim;Heuijin Lim;Sang Koo Kang;Sang Jin Lee;Tae Woo Kang;Seung Wook Kim;Wung-Hoa Park;Manwoo Lee;Kyoung Won Jang;Dong Hyeok Jeong
    • 한국의학물리학회지:의학물리
    • /
    • 제34권3호
    • /
    • pp.33-39
    • /
    • 2023
  • Purpose: FLASH radiotherapy (RT) using ultra-high dose rate (>40 Gy/s) radiation is being studied worldwide. However, experimental studies such as preclinical studies using small animals are difficult to perform due to the limited availability of irradiation devices and methods for generating a FLASH beam. In this paper, we report the initial dosimetry results of a prototype electron linear accelerator (LINAC)-based irradiation system to perform ultra-high dose rate (UHDR) preclinical experiments. Methods: The present study used the prototype electron LINAC developed by the Research Center of Dongnam Institute of Radiological and Medical Sciences (DIRAMS) in Korea. We investigated the beam current dependence of the depth dose to determine the optimal beam current for preclinical experiments. The dose rate in the UHDR region was measured by film dosimetry. Results: Depth dose measurements showed that the optimal beam current for preclinical experiments was approximately 33 mA, corresponding to a mean energy of 4.4 MeV. Additionally, the average dose rates of 80.4 Gy/s and 162.0 Gy/s at a source-to-phantom surface distance of 30 cm were obtained at pulse repetition frequencies of 100 Hz and 200 Hz, respectively. The dose per pulse and instantaneous dose rate were estimated to be approximately 0.80 Gy and 3.8×105 Gy/s, respectively. Conclusions: Film dosimetry verified the appropriate dose rates to perform FLASH RT preclinical studies using the developed electron-beam irradiator. However, further research on the development of innovative beam monitoring systems and stabilization of the accelerator beam is required.

미임계로 표적빔창의 열수력 해석 (Thermal Hydraulic Power Analysis of the HYPER Target Beam Window)

  • 송민근;주은선;최진호;송태영;탁남일;박원석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.39-42
    • /
    • 2002
  • The nuclear transmutation technology to Incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(${\underline{HY}}brid {\underline{P}}ower {\underline{E}}xtraction {\underline{R}}$eactor)is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Lead-bismuth(Pb-Bi) is adopted as a coolant and spallation target material. In this paper, we performed the thermal-hydraulic analysis of HYPER target using the commercial code FLUENT, and also calculated thermal and mechanical stress of the beam window using the commercial code ANSYS. It is found that there is an optimum value for the window diameter and the maximum allowable beam current can be increased to 17.3 mA for the inner diameter of windows, 40 cm. Finally, the other shapes such as uniform or scanned beam were considered. The results of FLUENT calculations show that the uniform type is preferable to the other shapes of the beam in terms of the window and target cooling and the maximum window temperature is lower than that of the parabolic beam by $58 ^{\circ}C$ for the beam current, 13 mA.

  • PDF